Light, temperature, and leaf nitrogen distribution in the tropical rain forest of Biosphere 2 and their importance in the mathematical models for global environmental changes

As the environmental changes occur throughout the world in rapid rate, we need to have further understandings for our planet. Since the ecosystems are so complex, it is almost impossible for us to integrate every factor. However, mathematical models are powerful tools which can be used to simulate those ecosystems with limited data. In this project, I collected light intensity, canopy leaf temperature and Air Handler (AHU) temperature, and nitrogen concentration in the leaves for different profiles in the rainforest mesocosm. These data will later be put into mathematical models such as "big-leaf" and "sun/shade" models to determine how these factors will affect CO2 exchange in the rainforest. As rainforests are diminishing from our planet and their existence is very important for all living things on earth, it is necessary for us to learn more about the unique system of rainforests and how we can co-exist rather than destroy.

Tohda, Motofumi↗

Hawai’i Climate: Utilizing NASA Earth Observations to Assess Thermal Stress Impacts on Coastal Hawaiian Fishponds

Hawaiian fishponds (loko i’a), ancient aquaculture systems created over 1500 years ago, historically served to harvest prized native fish species. Colonization-induced changes in land management have reduced active loko i’a from over 500 to ~20, destabilizing nearshore ecosystems and diminishing native Hawaiian cultural traditions. In recent decades, efforts to restore loko i’a have intensified as part of a broader emphasis on preserving Hawaiian cultural identity. Anthropogenic-induced climate change threatens these systems, particularly through the increase in frequency and magnitude of marine heatwaves. Though largely unexplored, these events are effectively studied utilizing remote sensing via Earth observations. Leveraging this technique enables autonomous extraction of water quality parameters to inform fishpond management. This study examined seven loko i’a across the main Hawaiian Islands (Hawai’i Island, Moloka’i, Maui, O’ahu, Kaua’i). Sea surface temperature and normalized difference chlorophyll index measurements were derived in fishponds utilizing Landsat 8 Thermal Infrared Sensor Thermal Infrared Sensor and Sentinel-2 MultiSpectral Instrument between 2013 to 2023, while regional patterns in temperature and chlorophyll-a were observed via Aqua’s Moderate Resolution Imaging Spectroradiometer (2002-2021). Employing these sensors, we focused analysis around the 2015 and 2019 marine heatwaves in the Pacific. We observed a heat stress gradient across the archipelago, creating thermally sheltered and unsheltered fishponds, yet identified no notable localized relationships between temperature and chlorophyll-a. Additionally, we applied pre-determined thermal maxima for culturally significant fish species (Striped Mullet: Mugil cephalus; Milkfish: Chanos Chanos) to assess historical habitat suitability within fishponds. While the direct impacts of marine heatwaves on loko i’a ecology are unknown, temperature patterns observed in this study are cause for concern.

Raz Wachtel↗

Efficient Air Dehumidification Can Save 15%-50% of Cooling Energy in Commercial Buildings

Current approach to dehumidification in commercial buildings with chilled/hot water AHU systems is to overcool return + supply air to dewpoint, and then reheat before supply to zone. This is energy inefficient, with reheat often being gas-fired. To reduce energy consumption, building operators will often operate at little-to-no outside air, sacrificing IAQ. Decarbonizing commercial buildings requires solutions to reduce and fully electrify dehumidification energy consumption. The Altaire ADAPT and Conservant HEDS systems aim to solve this problem by decoupling humidity control from cooling reduces energy consumption while enabling improved IAQ management.

commercial buildings↗

Chilled water temperature set-point reset based on outdoor air temperature and its cooling energy performance in an office building

Here, in this study, the cooling energy performance of two strategies for controlling ChWT (chilled water temperature) are compared: the conventional control strategy of constantly fixing ChWT and the OAT (outdoor air temperature) compensation control strategy that adjusts ChWT according to the changes in OAT. OAT compensation control strategy was modeled and realized based on Appendix G of ASHRAE Standard 90.1. It was confirmed that applying OAT compensation control strategy can significantly reduce chiller energy consumption, which accounts for the largest portion of total cooling energy consumption. It was found that the difference in total cooling energy consumption between applying the conventional control of constantly fixing ChWT to 6 °C and applying the OAT compensation control was approximately 8 % and 3 % during spring (March to May) and summer (June to August), respectively. Additionally, during the fall (September–November) period, about 7 % of total cooling energy consumption could be saved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Integration of Wi-Fi Location-Based Services to Optimize Energy Efficient Commercial Building Operations

This project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at commercial buildings located in Saint Paul, MN; Madison, WI; New York City; and Fort Worth, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LBNL Fault Detection and Diagnostics Datasets

These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equipment (rooftop unit, single-duct air handler unit, dual-duct air handler unit, variable air volume box, fan coil unit, chiller plant, and boiler plant). Each dataset includes a .pdf file to document key information necessary to understand the content and scope, multiple csv files containing all the time-series data for faults at different severity levels and one fault-free case, and a ttl file to visualize the data according to BRICK schema. The dataset was created by LBNL, PNNL, NREL, ORNL and Drexel University.

AC↗

Community engagement in the development of bioenergy projects from cellulosic urban waste feedstock in Hawaii for sustainable aviation fuel

The purpose of the research project was to reveal the perceptions of residents and communities of the City and County of Honolulu concerning bioenergy projects, feedstock, and sustainable aviation fuel. The perception study was conducted via community-scale surveys, interviews, and town meetings to gather feedback on the preliminary design of a proposed bioenergy project, including feedstock choice and the need for sustainable aviation fuel in Hawaii. Residents on the west side of Oahu were targeted due to their proximity to the proposed plant site location. Findings from this study aim to identify resident perceptions, understanding, and desire for bioenergy projects and new infrastructure to, improve the energy efficiency and sustainability of Hawaiian islands. While Hawaii has created policies and mandates to move toward 100% renewable energy sources by 2045, the focus has been predominately on renewable electricity, largely overlooking other sustainable energy options such as sustainable aviation fuel. There is a lack of research on the community engagement and perceptions of Hawaiian residents on bioenergy projects and sustainable aviation fuel, contributing to the low adoption of bioenergy projects on the islands. Insights from this study aim to add literature on the need for community engagement in the design process, the importance of accepting new sustainable infrastructure, and the production and use of sustainable aviation fuels.

09 BIOMASS FUELS↗