Engineering PapersSearch

SEARCH · Engineering Papers

Results for “47 - OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Simulations of the collection of mesospheric dust particles with a rocket instrument

We investigate the collection of dust particles in the mesosphere with the MESS (MEteoric Smoke Sampler) instrument that is designed to fly on a sounding rocket. We assume that the ice particles that form in the polar mesosphere between 80 and 85 km altitude in summer contain meteoric smoke particles; and these should be collected with MESS. The instrument consists of a collection device with an opening and closure mechanism, as well as an attached conic funnel which increases the sampling area in comparison to the collection area. Dust particles are collected either directly after passing through the instrument or indirectly after colliding with and fragmenting on the funnel wall. We calculate the dust and fragment trajectories in the detector to determine the collection efficiency for different particle sizes, rocket velocities, and heights, and we find the final velocities and the temperatures of the particles. The considered design has a sampling area of 62.78 mm diameter and a collection area of 20 mm diameter. For the conditions at the rocket launch site in Andøya, Norway, we estimate the collection of meteoric smoke particles contained in the ice particles to be ~10 12 –10 14 amu mm –2 . The estimated temperatures suggest that the composition of these smoke particles is not affected by the collection. Our calculations also show that keeping the instrument open above 85 km altitude increases the amount of small smoke particles that are directly collected. The directly collected smoke particles are heated as they decelerate, which can affect their composition.

47 OTHER INSTRUMENTATION

Wind Energy Instrumentation Development Roadmap

The instrumentation development roadmap provides a guide on which measurements, and instruments, are important for future field campaigns to meet both the science objects and validation plans for their successful execution. The roadmap ensures the measurements are of sufficient type and resolution to meet science objectives and validation needs essential to the campaigns. The roadmap includes measurement categories ranging from instruments that need to be created to existing instruments essential to the field campaigns. The creation of the instrumentation development roadmap builds upon the previous Atmospheric to Electrons (A2e) validation work and formation of the American WAKE experimeNt (AWAKEN) science objectives.

17 WIND ENERGY

ARM Lead Mentor Selection Process

The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud-formation processes and their influence on radiative transfer. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that provide ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, known as Mentors. Mentors must have an excellent understanding of instrumentation theory and operation for their instrument areas and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Facility seeks the best overall qualified candidate, or team when appropriate, that can fulfill Mentor requirements in a timely manner. The roles and responsibilities of the ARM Instrument Operations Manager are provided in Appendix A. The key role and responsibilities and detailed responsibilities of ARM Lead Mentors are provided in Appendix B and Appendix C, respectively.

47 OTHER INSTRUMENTATION

The OSIRIS-REx Sample Return Capsule re-entry: A coordinated seismo-acoustic observational campaign for the study of meteor phenomena

Objects entering Earth’s atmosphere at hypersonic velocities may generate powerful acoustic waves. Depending on atmospheric conditions and acoustic propagation paths, they may be captured using ground or balloon-borne microbarometers and microphones. Impacts into the Earth’s atmosphere by asteroids in a meter-size range are sporadic and unannounced, and thus, well-documented scientific observations of asteroids are rare and generally happen by chance. Arriving from interplanetary space at hypervelocity, spacecraft are considered analogues for low velocity meteoroids and asteroids impacting the Earth’s atmosphere, and as such provide unprecedented and unique opportunity to carry out planned observational campaigns and perform detailed studies of meteor phenomena. However, since the end of the Apollo era, only four instances of a hypersonic re-entry of an artificial body from interplanetary space with an incident speed of 11-12 km/s have been observed and studied. These were the Sample Return Capsules (SRCs) that brought physical samples of extraterrestrial material back to Earth (Genesis, Stardust, Hayabusa 1, Hayabusa 2). These re-entries were also detected by infrasound and/or seismic sensors. The next opportunity to observe an artificial meteor will be on 24 September 2023 with the re-entry of NASA’s OSIRIS-REx SRC that will bring samples of the carbonaceous near-Earth asteroid Bennu. The re-entry consists of several flight phases, including hypersonic and supersonic, providing a unique opportunity to observe these by infrasound and seismic sensors. We will discuss observational campaign efforts aimed to capture geophysical signals generated by the OSIRIS-REx SRC re-entry. This campaign utilizes an unparalleled number of instruments, both ground and airborne, strategically positioned in the immediate and extended region around the projected re-entry trajectory to maximize the scientific output.

47 - OTHER INSTRUMENTATION

Ultrafine Condensation Particle Counter Instrument Handbook

The Model 3776 Ultrafine Condensation Particle Counter (UCPC; pictured in Appendix A) is designed for researchers interested in airborne particles smaller than 20 nm. With sensitivity to particles down to 2.5 nm in diameter, this UCPC is ideally suited for atmospheric and climate research, particle formation and growth studies, combustion and engine exhaust research, and nanotechnology research.

47 OTHER INSTRUMENTATION

Assessment of North Slope of Alaska (NSA) Snow Monitoring Arrays

Arrays of instruments for monitoring winter precipitation (snowfall) and snow cover on the ground installed in 2017 at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska (NSA) C1 and at Oliktok Point sites became operational in 2018. In 2022, the instruments from Oliktok Point were moved to NSA E12, about 5.4 km south of NSA C1, where two arrays now operate. The instrument arrays monitor wind speed and direction, snow depth at multiple locations, the horizontal flux of blowing snow, and the number and fall speed of hydrometeors. The arrays are monitored using digital cameras. Collectively, the instruments produce a wealth of data on falling and accumulated snow, but, as with any instrument array, some data are more reliable and accurate than others. In this document, we present our findings on the efficacy, accuracy, and reliability of each type of instrument. Overall, a key finding is that no single instrument provides sufficient information to determine the source of falling snow particles nor the cause of changes in snow depth. However, if used in concert, the instruments produce a reliable understanding of the processes affecting the snow cover depth distribution and the true winter precipitation.

47 OTHER INSTRUMENTATION

CMB-S4 Instrument Modeling and Development for CMB-S4

During this thirteen month award, we focused on two main tasks relevant to the development of the CMB-S4 project: (1) The refinement of sensitivity models and use of those to optimize the instrument design, and (2) the final development and testing a cryogenic blackbody calibrator prototype, of which we then produced three copies for CMB-S4's detector testing systems at FNAL, SLAC and UIUC.

47 OTHER INSTRUMENTATION

Enhancing a LArTPC with a magnetic field

This paper presents the results of the 2024 Summer Students Italian program at the Fermi National Accelerator Laboratory completed by participant Lorenzo Unich, which lasted between the 27th of July and the 29th of September. This project, which bears the same title of this paper, was supervised by Marco del Tutto, researcher at the Fermi National Accelerator Laboratory. In the first section, we introduce the instruments used throughout the project, detailing their origins and the goals of the traineeship. The second section presents the hardware work conducted, while the final section focuses on the simulations performed for the experimental apparatus. Unless otherwise cited, all pictures and graphs are original.

42 ENGINEERING

DrEVL Radiometer Calibration

This report details the calibration procedures that were used for the spectral and radiometric part of the DrEVL radiometers. Our goal was to develop a highly repeatable and low cost spectral radiometer that could be deployed at numerous sites to collect a catalog of lightning data. Maximizing the re-usability of that data requires a well-calibrated instrument.

47 OTHER INSTRUMENTATION

Assessing Options for Particulate Measurement Tools to Advance Wood Heaters (CRADA Final Report)

For approximately 40 years, particulate matter (PM) from residential wood heaters has been certified in North America using an EPA dilution tunnel with a filter-based gravimetric measurement. While reasonably repeatable, this approach reports only a single value for the entire burn sequence and does not provide information on PM at different points within the sequence, which would support improved wood heater designs. PM monitors that report with high time resolution offer a potential solution, but their performance for various types of heaters and across heater operating conditions has not been extensively evaluated. In this 18-month collaborative project, the Hearth, Patio & Barbecue Association (HPBA) and Lawrence Berkeley National Laboratory (LBNL) tested five continuous PM instruments spanning three measurement principles—light-scattering, inertial mass (TEOM), and triboelectric—against gravimetric and size-resolved references on three residential heater types (cordwood, catalytic cordwood, and pellet) across startup, high-burn, and low-burn operating phases.

42 ENGINEERING

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE

A formaldehyde and nitrogen dioxide toxics monitor for environmental justice

DOE’s Integrated Field Laboratories (IFLs) require a vast array of measurements to measure urban air quality. Nitrogen dioxide (NO2) and formaldehyde (HCHO) are ubiquitous pollutants with numerous sources, most notably vehicle exhaust. High-spatial density measurements are critical to understanding how certain neighborhoods are more adversely impacted by pollutants. This report describes the results of a Phase I SBIR project to develop and demonstrate a rapid, affordable, low-power monitor to provide high spatial resolution mobile measurements of formaldehyde and nitrogen dioxide at street-level, where people live and walk. The spatial density will be achieved via rapid measurements on a mobile platform. This sensor will quantify spatial disparities in cities of the toxics, HCHO and NO2, as well as carbon monoxide and carbon dioxide for better source identification. These species are detected in the mid infrared by laser absorption spectroscopy, and fiberoptics are used. Tasks accomplished include identification and testing of the appropriate spectroscopic regions; coupling of laser light into a fiberoptic system; development of software to control miniature electronics to scan and control two lasers simultaneously; coupling of the mid infrared fiber into a multipass cell for enhanced pathlength and sensitivity; characterization of sources of instrument noise; and design work for a Phase II prototype.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Instrumentation and Samples (CRADA Final Report)

Instruments which are categorized as shared user instruments at the National Laboratory of the Rockies (NLR) will be utilized for ongoing technical work. Samples will be provided by University of Colorado Boulder (CU) and thus no need for materials at NLR is anticipated.

(Ga1- xZnx)(N1-xOx)

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 23-October 4, 2024

The comparison of the absolute cavity pyrgeometers (ACPs) with the CG4 FT005 pyrgeometer traceable to the InfraRed Integrating Sphere (IRIS) referred to by FT005(IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 23 to October 4, 2024. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. Two methods described in and were used for the comparison based on original Reda et. al and proposed Forgan et. al.

47 OTHER INSTRUMENTATION

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION

Zeteotech, LLC TRGR Project Final Report

Reliable detection of aerosolized pathogens is difficult due to need to distinguish between the benign bioaerosols such as dander and pollen and the thousands of pathogens capable of infecting people. Accurate identification of airborne pathogens of concern in the past has required the collection of aerosol samples in a filter, periodic collection of the samples, and processing and identification in the laboratory. This process is labor intensive and expensive. Additionally, this method necessarily has a time to detection window of hours to days depending on the collection frequency. Biological pathogens have an incubation period before the onset of symptoms and severe health effects and/or mortality, people will typically be exposed to them without realizing it. This has resulted in a detect to treat strategy for protection against bio releases. While prophylactic measures can still be effective over these time scales, reducing the time to detection will significantly improve the effectiveness of these measures and subsequently reduce the consequences of a release. Various attempts to reduce the time to detection and identification have been plagued by highly undesirable false-positives which degrade confidence in the system. Zeteotech, LLC has developed a mass spectrometer based bioaerosol sensing system which is capable of autonomously identifying airborne pathogens of concern and alert authorities within minutes instead of hours to days. They have deployed these instruments to protect high-risk facilities by alerting authorities of public health events and intentional bioterrorism events in near real time. This makes it possible to more accurately identify the time and location of the release and minimize the number of people that are exposed through prompt quarantining of affected areas.

47 OTHER INSTRUMENTATION

Calculation of rf-induced temporal jitter in ultrafast electron diffraction

A significant contribution to the temporal resolution of an ultrafast electron diffraction (UED) instrument is arrival time jitter caused by amplitude and phase variation of radio-frequency (rf) cavities. In this paper, we present a semianalytical approach for calculating rf-induced temporal jitter from klystron and rf cavity parameters. Our approach allows fast estimation of temporal jitter for MeV-UED beamlines and can serve as a virtual timing tool when shot-to-shot measurements of rf amplitude and phase jitters are available. A simulation study for the SLAC MeV-UED instrument is presented, and the temporal resolution of several beamline configurations is compared.

47 OTHER INSTRUMENTATION

How are Heterogeneous Nucleation Rate Observations Influenced by Instrument Resolution?

Experimental measurements of the heterogeneous nucleation rate rely on counting the number of nuclei with time. However, the size of a thermodynamically stable nucleus is often a few nanometers in diameter and is below the resolution of most (in situ) measurement techniques that provide a statistically valid sample. Due to the finite resolution of the instruments and analysis methods, it is challenging to capture the incipient nuclei and the subsequent evolution of nuclei density over time. In this work, we demonstrate the impact of instrument resolution on observed nuclei densities by comparing numerical modeling with experimental results. Further, to achieve this, we implemented heterogeneous nucleation within the pore-scale reactive transport modeling framework using classical nucleation theory (CNT). We compared the modeling results with nucleation rates measured using X-ray nanotomography (XnT) and evaluated how these impact the apparent values of the prefactor and interfacial energy based on CNT and the crystal growth rate. Specifically, we applied a resolution threshold (artificial resolution limit) in the model during nuclei counting to resemble an experimental resolution, ranging from 15 to 500 nm. The findings reveal that the instrument resolution significantly impacts the apparent prefactor and interfacial energy. Both apparent prefactor and interfacial energy decrease with a decrease in the instrument resolution. While deviation in the prefactor due to resolution is anticipated, those in the interfacial energy are unexpected. The approach described here allows one to correct apparent nucleation rates that depend on the instrument’s resolution to derive “intrinsic” CNT parameters for the prefactor and interfacial energy.

47 OTHER INSTRUMENTATION