Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “200 kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Solar Resource and Infrastructure Assessment for the Town of Wendell

This report is a solar resource and infrastructure assessment for the town of Wendell, Massachusetts. The assessment was funded through the National Renewable Energy Laboratory, Solar Energy Innovation Network (NREL SEIN) Solar in Rural Communities Program, as part of a project to develop a Community-Informed Proactive Solar Siting and Financing Model. As a first step, the project lead organization, UMass Clean Energy Extension prepared an assessment of existing infrastructure, resources, and potential solar development opportunities in participating municipalities, including Wendell. This assessment was designed to describe relevant bylaws and infrastructure within the town, identify the types of solar facilities that could be developed, and quantify the total space available for each type of facility. In this report, we reviewed existing electricity grid infrastructure, and the potential to interconnect additional solar facilities. At the present time, both distribution lines providing electricity to Wendell are over-saturated with authorized and proposed solar projects, and cannot accommodate additional solar projects to interconnect to the grid. It appears that National Grid is planning an upgrade to the Wendell Depot substation, which might then allow in-process projects are to proceed, and potentially free up additional capacity for new, large projects. Meanwhile, most three-phase lines could likely accommodate additional small-to-medium scale projects (under 200 kW), and most single-phase lines could likely accommodate additional projects under 50 kW in size. This description represents the local grid infrastructure as it is - planning for future scenarios of development could include recommendations for areas of grid infrastructure improvement to allow siting of distributed generation in locations preferred by the community. Future scenarios may also include the addition energy storage and other "non-wires alternatives."

14 SOLAR ENERGY↗

Solar Resource and Infrastructure Assessment for the Town of Westhampton

This report is a solar resource and infrastructure assessment for the town of Westhampton, Massachusetts. The assessment was funded through the National Renewable Energy Laboratory, Solar Energy Innovation Network (NREL SEIN) Solar in Rural Communities Program, as part of a project to develop a Community-Informed Proactive Solar Siting and Financing Model. As a first step, the project lead organization, UMass Clean Energy Extension prepared an assessment of existing infrastructure, resources, and potential solar development opportunities in participating municipalities, including Westhampton. This assessment was designed to describe relevant bylaws and infrastructure within the town, identify the types of solar facilities that could be developed, and quantify the total space available for each type of facility. In this report, we reviewed existing electricity grid infrastructure, and the potential to interconnect additional solar facilities. At the present time, both distribution lines providing electricity to Westhampton are oversaturated with authorized and proposed solar projects, and cannot accommodate additional solar projects to interconnect to the grid. Future upgrades could potentially free up additional capacity for new, large projects. Meanwhile, most three-phase lines could likely accommodate additional small-to-medium scale projects (under 200 kW), and most single-phase lines could likely accommodate additional projects under 50 kW in size. This description represents the local grid infrastructure as it is - planning for future scenarios of development could include recommendations for areas of grid infrastructure improvement to allow siting of distributed generation in locations preferred by the community. Future scenarios may also include the addition energy storage and other "non-wires alternatives."

14 SOLAR ENERGY↗

Molten Salt Loop Testing of Sensors and Off-Gas Components: FY23 progress

The Liquid Salt Test Loop (LSTL) at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature fluoride salt systems (Figure 1). The LSTL is primarily constructed using Inconel 600 alloy and operates at temperatures of up to 700°C. The facility is loaded with 165 kg of LiF-NaF-KF salt (FLiNaK). This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. FLiNaK is also an advantageous salt for the secondary side of molten salt reactors. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. Additional heating is available through an induction heater rated at 200 kW. The relatively large heating and cooling capability enables the formation of a temperature gradient across the loop (i.e., a hot and a cold side), which is important for chemistry and corrosion studies. The LSTL is a unique US capability for high-temperature molten halide salt testing. Although some efforts are underway at universities, the LSTL’s scale, co-located purification system, and relatively large power differentiates it from other testing systems. Furthermore, unlike efforts within industry, access to the DOE-supported facility and communication of results, which are generally disseminated publicly, result in a broad significance in the molten salt reactor community.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Vertical GaN-Based Neutral-Pointless Three-Level Inverter for High-Performance Automotive Traction Applications

Silicon Carbide (SiC) MOSFETs have emerged as a dominant solution for electric vehicle traction inverters because of their superior power density and efficiency compared to Silicon (Si) counterparts. However, SiC devices possess inherent switching speed limitations that constrain the maximum switching frequency and hinder further power density and efficiency improvements. To address these limitations, this paper proposes a vertical Gallium Nitride (vGaN) based X-type Neutral-Pointless (NPL.X) three-level (3L) inverter for an 800V, 200 kW traction system. Integrating 700V vGaN technology within the NPL.X 3L topology enables improved drive efficiency and higher switching frequencies, resulting in enhanced power density and output power quality. To evaluate the performance benefits, this work conducts a comprehensive loss characterization of the vGaN￾based NPL.X topology, providing a direct comparison with a SiC￾based two level (2L) inverter. The results show that the proposed vGaN-based inverter achieves superior efficiency, particularly within the low-torque regions that dominate standard automotive drive cycles. The proposed vGaN-based inverter represents a critical advancement toward high-power-density and high efficiency traction drives

Halawa, Ali [Purdue Univ., West Lafayette, IN (Uni↗

X-Band Scanning ARM Precipitation Radar, CF/Radial Formatted, Quality Controlled

The X-band Scanning ARM Precipitation Radar (X-SAPR) is an X-band dual-polarization Doppler weather radar. The X-SAPR operates in a simultaneous transmit and receive (STAR) mode, meaning that the transmit signal is split so that power is transmitted on both horizontal and vertical polarizations at the same time. The X-SAPR transmitter is a 200 kW (peak power) magnetron. The receiver is based upon the Vaisala RVP-900 and runs Vaisala’s IRIS software. In addition to the first three Doppler moments (reflectivity, radial velocity, and spectra width), the X-SAPR also provides differential reflectivity, correlation coefficient, and specific differential phases. The dual-polarization variables enable estimates of rainfall rates and identification of precipitation types. At the Southern Great Plains site, three X-SAPRs surround the Central Facility, allowing the use of multi-Doppler velocity retrievals to estimate wind fields.

xsaprcfrqc↗

Refining Absorber Shroud Geometry to Maximize Power Output and Reduce Power Peaking in ATF Test Train

In the wake of the Fukushima Daiichi nuclear power plant accident in 2011, the accident tolerant fuels (ATF) program was initiated to enhance the safety of light-water reactor fuels, placing significant emphasis on cladding. A crucial step for the broad implementation of ATF in commercial reactors involves irradiation testing of the fuel designs. ATF-2D, the latest experiment in the ATF series, is slated to undergo irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). ATF-2D is a joint effort of the INL with industry partners General Electric Global Research; Framatome; General Atomics; the Japan Atomic Energy Agency; Hitachi-GE Nuclear Energy, Ltd; Global Nuclear Fuel-Japan Co., Ltd; Nippon Nuclear Fuel Development Co., Ltd; and Mitsubishi Heavy Industries, Ltd. The ATF-2D test train design consists of four tiers, each housing six rodlets. The device will be inserted in Loop 2A within the central flux trap of the ATR, and is anticipated to undergo irradiation throughout three 60-day cycles. Typical pressurized water reactor conditions will be emulated during the irradiation. The objective of the work presented here is to dimension neutron-absorbing hafnium (Hf) components surrounding the fuel rodlets, such that the axial power profile is flattened, while simultaneously ensuring that the total fission power output of the entire test train remains below 200 kW.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Refining Absorber Shroud Geometry to Maximize Power Output and Reduce Power Peaking in ATF Test Train

In the wake of the Fukushima Daiichi nuclear power plant accident in 2011, the accident tolerant fuels (ATF) program was initiated to enhance the safety of light-water reactor fuels, placing significant emphasis on cladding. A crucial step for the broad implementation of ATF in commercial reactors involves irradiation testing of the fuel designs. ATF-2D, the latest experiment in the ATF series, is slated to undergo irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). ATF-2D is a joint effort of the INL with industry partners General Electric Global Research; Framatome; General Atomics; the Japan Atomic Energy Agency; Hitachi-GE Nuclear Energy, Ltd; Global Nuclear Fuel-Japan Co., Ltd; Nippon Nuclear Fuel Development Co., Ltd; and Mitsubishi Heavy Industries, Ltd. The ATF-2D test train design consists of four tiers, each housing six rodlets. The device will be inserted in Loop 2A within the central flux trap of the ATR, and is anticipated to undergo irradiation throughout three 60-day cycles. Typical pressurized water reactor conditions will be emulated during the irradiation. The objective of the work presented here is to dimension neutron-absorbing hafnium (Hf) components surrounding the fuel rodlets, such that the axial power profile is flattened, while simultaneously ensuring that the total fission power output of the entire test train remains below 200 kW.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Propulsion System Design using a Dual 3-Phase PM Synchronous Reluctance Machine with X-Type Multi-Level GaN Inverter

— A propulsion system design is exhibited here that comprises of an X-type GaN power module based dual multi-level inverter and a PM Synchronous Reluctance motor. With the critical benefits of multi-level operation, namely low common mode EMI noise, low switching loss, low current Total Harmonic Distortion (THD), smoother torque and lower iron loss, this topology targets high system-level efficiency and high power density while using reduced rare earth (RE) elements in its motor. General Motors and Purdue University jointly designed and developed this 800V class, highly scalable traction drive that can deliver 200+ kW of power suitable for C-SUV to truck vehicle class. The 3-phase electric machine design utilizes dual winding with 6 terminals to work in line with the GaN X-type inverter, and results in a tractive solution that ensures higher machine efficiency while reducing cost and uncertainty related to use and availability of heavy rare earth/rare earth elements in its rotor.

MOMEN, FAIZUL [General Motors LLC, Detroit, MI (Un↗

Performance of Photovoltaic Systems Recorded by Open Solar Performance and Reliability Clearinghouse (oSPARC)

This article analyzes data from 2,200 photovoltaic systems collected through the Open Solar Performance and Reliability Clearinghouse (oSPARC, 2018) to draw conclusions about the measured performance of the systems, how it compares to expectations, and how wide the variation is. The systems range in size from 2 kW to 1,200 kW, with an average size of 229 kW, and were activated in oSPARC between March 13, 2007 and Dec. 16, 2016. Data regarding co-incident insolation and ambient temperature are provided through the oSPARC platform for the population of systems and summarized here. Results indicate that - after correcting for measured insolation, derating for temperature, and correcting for balance-of-system efficiency and degradation as a result of system age - the performance ratio of these 2,200 systems averages 91.7%. Adjusting for known parameters such as age and efficiency, the ratio would ideally be 100%. Thus, the 'underperformance' of this system sample is measured at 9.3% and suggests that as much as 9.3% could be recovered if the systems were caused to perform as expected through optimal operation and maintenance. Efforts to correlate the performance ratio with environmental conditions resulted in very low coefficients of regression, but the method already normalizes for actual site insolation and temperature, which are responsible for much of the site-specific variation. An exemption is air-quality nonattainment areas, where the measured performance of plants averages 86.9% and is consistently lower than the average of 95.9% in areas that are in compliance with air quality standards, likely because of particulate matter such as diesel soot exacerbating the soiling rate.

14 SOLAR ENERGY↗

Upgraded fiber-optic sensor system for dynamic strain measurement in Spallation Neutron Source

We describe an upgraded fiber-optic sensor system and its performance in measuring the dynamic strains in a mercury target of the Spallation Neutron Source (SNS). Strains result from dynamic pressure waves in the stainless-steel mercury target induced by short (~700 ns), intense (up to 23.3 kJ), high-energy (~1 GeV) proton pulses. In the upgraded sensor system, the output of each sensor head is interrogated with a compact, all-fiber based Faraday Michelson interferometer, which generates interference signals with a steady phase shift. Strain waveforms are recovered from the phase-shifted interference signals using a high-speed digital signal processing procedure developed in our previous work. We demonstrate successful measurements of dynamic strain pulses, e.g., 400με over 190μs , on a recently installed SNS target using the upgraded sensor system. The measured strain waveforms are analyzed for more than 20 sensor locations and/or orientations, and provide information regarding the temporal structure of strain profiles and dependence of the strain magnitude on the proton powers of 200 – 1400 kW. The new interrogator also measures the radiation-induced-attenuation (RIA) in the optical fiber, enabling experimental investigations of RIA profiles induced by a 700-ns radiation pulse. The radiation effects on the strain measurement performance are discussed over a radiation dose range of up to 4×10 8 Gy and an RIA compensation method is proposed. The measurements allow insight into the response of this unique piece of equipment and can be used for validation of simulations.

47 OTHER INSTRUMENTATION↗

The Internal Compound Parabolic Concentrator (ICPC): a Novel Low Cost Solar Thermal Collection System for Desalination Processes

The research team at UC Merced designed, prototyped, and tested (1) a novel low cost non-tracking solar thermal collector/concentrator called the Integrated Compound Parabolic Concentrator (ICPC) and (2) a low-cost phase-change thermal energy storage system. Together these technologies can significantly reduce the levelized cost of heat from solar thermal sources while also incorporating features of dispatchability and portability. The ICPC allows elevated temperature and efficiency in a low cost, non-tracking collector. The collector has demonstrated 60% ±4% solar to thermal modules efficiency at fluid outlet temperature of 120°C. The raw material cost of the collector system is reduced by utilizing low cost aluminum minichannels. The collector design is also amenable to economic mass production. A 200 tube, 10 kW prototype array was constructed and tested, yielding over 6 kWh/day on average at outlet fluid temperature exceeding 120°C.

14 SOLAR ENERGY↗

A Novel Bi-directional AC/DC - DC/AC Wireless Power Transfer System for Grid Support Applications

The severity of the economic impact caused by grid outages has been the driving factor for creating innovative solutions that increases interest for the deployment of distributed energy resources to reduce the impact of grid outages. This paper presents a novel topology for providing export power applications. Proposed topology can be used for grid (primary)-side of bi-directional wireless power transfer (WPT) systems, mobile energy storage systems (ESSs), and electric vehicle (EV) batteries. The proposed concept here achieves energy transfer between sources by using a hybrid frequency bi-directional ac/dc converter without an additional front-end converter stage compared to the conventional systems. Due to inherent merit of the proposed bi-directional ac/dc converter, ac input with 60 Hz grid frequency can be directly transferred through the wireless coils and can be directly converted to the dc. Results demonstrate the performance and the functionality of the single-phase bi-directional system with the input / output of 110 V ac,rms and 200 V dc at 1 kW power. Full paper will demonstrate the converter operation at 10 kW power level with additional features and control aspects.

Asa, Erdem↗

Sludge Removal: Success and Partnership with T Plant - 20510

U.S. DOE contractor CH2M Hill Plateau Remediation Company (CHPRC) has safely and efficiently managed the removal of highly radioactive sludge from the 105-K West Reactor fuel storage basin (105- KW Basin) near the Columbia River. In mid-September 2019, sludge retrieval was completed after 21 storage containers were safely loaded with highly radioactive sludge and transported approximately 13 miles from the 105-KW Basin to T Plant, located in the 200 West Area on the Central Plateau of the Hanford Site. Sludge removal represents the last major source term reduction necessary before the K West Reactor and fuel storage basin can transition to closure activities in preparation for final deactivation and demolition. The technical complexity of the sludge retrieval process, coupled with the challenging physical and radiological characteristics of the waste, necessitated a methodical and deliberate approach using unique design and operational solutions to safely conduct the work. This challenge was further complicated by the need to plan and conduct the work in two separate facilities, each subject to the controls and requirements of its own nuclear facility safety basis. The project overcame these challenges through creating an integrated team that actively engaged, communicated and coordinated each phase of the project to ensure successful completion. This paper will cover how these key elements of the Sludge Removal Project led to its success: - Integrating project planning and management; - Lessons learned from design and construction; - Preparing for a successful campaign (lessons learned from testing and start-up); - Lessons learned from operating in two separate facilities, transporting sludge containers on the Hanford Site and ensuring compliance with a range of regulatory and safety basis requirements. The establishment of an integrated group spanning two facilities and multiple organizations created a team capable of overcoming the challenges necessary to successfully plan and execute the sludge retrieval mission. Sharing lessons learned from this successful project can enhance the ability of teams across the DOE complex to successfully plan and execute complex projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scalable and compact magnetocaloric heat pump technology

Magnetocaloric heat pumping (MCHP) promises to be more efficient than traditional vapor compression while also eliminating the deleterious effects of gaseous refrigerants. While MCHP devices have shown the temperature spans and efficiencies needed for different heating and cooling applications, they struggle to become commercially viable due to their large size and mass, and resultant high cost. This paper evaluates a baseline MCHP device and explores methods to boost its system power density (SPD). The key components of the baseline system are the gadolinium packed-particle bed active magnetic regenerator (AMR) and a magnetic source composed of permanent magnets and high permeability magnetic steel. To enhance the SPD, the paper evaluates maximizing the AMR volume, opting for first-order magnetocaloric materials, optimizing the magnet and AMR geometry, and reducing the size of magnets and magnetic steel parts. At larger thermal powers, increasing the AMR diameter and the number of magnetic poles were evaluated. Using finite element models, solid models, and estimates of magnetocaloric material performance, thermal powers ranging from 37 W to 44 kW at a nominal 10 K temperature span were projected, and SPD was estimated to improve from 6 W/kg to 81 W/kg. Neglecting end effects, an upper limit of 114 W/g is estimated. Compared to SPD of off-the-shelf compressors with similar environment temperatures, MCHP power density using gadolinium is competitive up to roughly 200 W of cooling power. This is extended to 1 kW when using LaFeSi alloys and up to 3 kW in the limiting case. In conclusion, these results indicate that the performance and mass of MCHP can match that of compressors, which is a critical step toward cost-competitive magnetocaloric technology.

42 ENGINEERING↗

Heavy ion beam physics at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) will be the world's premier rare-isotope beam facility. Experiments with the majority (~80%) of the isotope predicted to exist will become available. The FRIB facility is based on a superconducting (SC) heavy ion linac with output energy above 200 MeV/u for any ions at beam power of 400 kW. FRIB includes a target facility for in-flight production of rare isotopes. A three-stage fragment separator will be used to prepare fast rare isotope beams with high-purity for nuclear physics experiments. The installation work of the accelerator and experimental systems is approaching completion and multi-stage beam commissioning activities started in summer 2017 with expected project completion in early 2022. In conclusion, the commencement of operation for users' experiments is planned immediately following the project completion.

43 PARTICLE ACCELERATORS↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10’s of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with 7 kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5 kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

insulation resistance↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation: Preprint

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10's of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with $7$\,kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5\,kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗