Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “10-Be”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Two-Dimensional Bifurcated Inlet/Engine Tests Completed in 10- by 10-Foot Supersonic Wind Tunnel

A Two-Dimensional Bifurcated (2DB) Inlet was successfully tested in NASA Lewis Research Center s 10- by 10-Foot Supersonic Wind Tunnel. These tests were the culmination of a collaborative effort between the Boeing Company, General Electric, Pratt & Whitney, and Lewis. Extensive support in-house at Lewis contributed significantly to the progress and accomplishment of this test. The results, which met or exceeded many of the High-Speed Research (HSR) Program goals, were used to revise system studies within the HSR Program. The HSR Program is focused on developing low-noise, low-polluting, high-efficiency supersonic commercial aircraft. A supersonic inlet is an important component of an efficient, low-noise vehicle.

Saunders, John D.↗

Reflective Focused Schlieren System Improved for Use in 10- by 10-Foot Supersonic Wind Tunnel

The reflective focused schlieren system that was developed for use in the 10- by 10-Foot Supersonic Wind Tunnel (10x10 SWT) at the NASA Glenn Research Center at Lewis Field as part of the Unstart Test Program was improved this past year. In April 1999, the development and use of the system was presented at the Supersonic Tunnel Association International in Bedford, England. A focused schlieren system is similar to a standard schlieren system in that shock waves coming from an object in supersonic flow can be seen using a standard video camera. Unlike the standard schlieren system, which produces a two-dimensional schlieren image, a focused schlieren system can produce a threedimensional image. The preceding drawing shows the components of the reflective focused schlieren system being developed for use in the 10x10 SWT. Although the system worked well for the Unstart Test Program, it was not sensitive enough to be classified as a facility capability. Therefore, a program was implemented to improve the sensitivity of the reflective focused schlieren system so that it could be a facility capability for Glenn's 10x10 SWT. Several techniques were implemented to increase the sensitivity and to improve the overall operation of the system. These included refinement of the source grid, improvement in the cutoff grid production, improvement of the source grid and cutoff grid alignment, installation of an improved light source, and incorporation of an image-enhancing system. These changes are being implemented with the system set up in the laboratory. A checkout test of the system is planned in the 10x10 SWT in March 2000. Of these techniques, the most developed is the refinement of the source grid. The original system had a pattern of -in. by -in. squares on -in. centers (distance between the center points of adjacent squares). This gave a ratio of light to dark (reflective to nonreflective area) of 3:1. The recommended ratio is 1:1. In order to accomplish this, a pattern of -in.-diameter dots on 3/8-in. centers was developed. Preliminary tests with this pattern showed an increase in system sensitivity and image clarity. Further testing and refinement are scheduled. The former and improved dot patterns are shown. The use of glass plates to produce the cutoff grid improved the cutoff grid's quality and helped to align it with the source grid. The cutoff grid, which is the negative of the source grid, is made by exposing photography film (or glass plates) to the proper light while it is installed in the focused schlieren system. The exposed film or plate is removed from the system and then developed as a photograph negative. Because the glass plates are rigid, they eliminate the risk of distortion when the negative is reinstalled in the system and realigned with the source grid.

Williamson, Gary Scott↗

Two-Dimensional Bifurcated Inlet Variable Cowl Lip Test Completed in 10- by 10-Foot Supersonic Wind Tunnel

Researchers at the NASA Glenn Research Center at Lewis Field successfully tested a variable cowl lip inlet at simulated takeoff conditions in Glenn s 10- by 10-Foot Supersonic Wind Tunnel (10x10 SWT) as part of the High-Speed Research Program. The test was a follow-on to the Two-Dimensional Bifurcated (2DB) Inlet/Engine test. At the takeoff condition for a High-Speed Civil Transport aircraft, the inlet must provide adequate airflow to the engine with an acceptable distortion level and high-pressure recovery. The test was conducted to study the effectiveness of installing two rotating lips on the 2DB Inlet cowls to increase mass flow rate and eliminate or reduce boundary layer flow separation near the lips. Hardware was mounted vertically in the test section so that it extended through the tunnel ceiling and that the 2DB Inlet was exposed to the atmosphere above the test section. The tunnel was configured in the aerodynamic mode, and exhausters were used to pump down the tunnel to vacuum levels and to provide a maximum flow rate of approximately 58 lb/sec. The test determined the (1) maximum flow in the 2DB Inlet for each variable cowl lip, (2) distortion level and pressure recovery for each lip configuration, (3) boundary layer conditions near variable lips inside the 2DB Inlet, (4) effects of a wing structure adjacent to the 2DB Inlet, and (5) effects of different 2DB Inlet exit configurations. It also employed flow visualization to generate enough qualitative data on variable lips to optimize the variable lip concept. This test was a collaborative effort between the Boeing Company and Glenn. Extensive inhouse support at Glenn contributed significantly to the progress and accomplishment of this test.

Hoffman, T. R.↗

Abe Silverstein 10- by 10-Foot Supersonic Wind Tunnel Validated for Low-Speed (Subsonic) Operation

The NASA Glenn Research Center and Lockheed Martin Corporation tested an aircraft model in two wind tunnels to compare low-speed (subsonic) flow characteristics. Objectives of the test were to determine and document the similarities and uniqueness of the tunnels and to validate that Glenn's 10- by 10-Foot Supersonic Wind Tunnel (10x10 SWT) is a viable low-speed test facility. Results from two of Glenn's wind tunnels compare very favorably and show that the 10x10 SWT is a viable low-speed wind tunnel. The Subsonic Comparison Test was a joint effort by NASA and Lockheed Martin using the Lockheed Martin's Joint Strike Fighter Concept Demonstration Aircraft model. Although Glenn's 10310 and 836 SWT's have many similarities, they also have unique characteristics. Therefore, test data were collected for multiple model configurations at various vertical locations in the test section, starting at the test section centerline and extending into the ceiling and floor boundary layers.

Hoffman, Thomas R.↗

Check Calibration of the NASA Glenn 10- by 10-Foot Supersonic Wind Tunnel (2014 Test Entry)

A check calibration of the 10- by 10-Foot Supersonic Wind Tunnel (SWT) was conducted in May/June 2014 using an array of five supersonic wedge probes to verify the 1999 Calibration. This check calibration was necessary following a control systems upgrade and an integrated systems test (IST). This check calibration was required to verify the tunnel flow quality was unchanged by the control systems upgrade prior to the next test customer beginning their test entry. The previous check calibration of the tunnel occurred in 2007, prior to the Mars Science Laboratory test program. Secondary objectives of this test entry included the validation of the new Cobra data acquisition system (DAS) against the current Escort DAS and the creation of statistical process control (SPC) charts through the collection of series of repeated test points at certain predetermined tunnel parameters. The SPC charts secondary objective was not completed due to schedule constraints. It is hoped that this effort will be readdressed and completed in the near future.

pressure measurement↗

Summary of the 2017 Blockage Test in the 10- by 10-Foot Supersonic Wind Tunnel

A limited blockage study was performed in December 2017 to explore exceeding the current published blockage curve for the NASA Glenn 10- by 10-Foot (10x10) Supersonic Wind Tunnel (SWT) at two discrete operating conditions. For the two points tested, the tunnel was found to start outside of the published starting limitations curve, above a certain threshold of Mach and stagnation pressure. Blockage theory was reviewed to further understand these results. In order to gain a firm understanding of the aerodynamic effects a more-detailed follow up blockage study is recommended.

Tunnel Start↗

Use of CFD in the Design of the 10- by 10-Foot Supersonic Wind Tunnel Characterization Array

At the 10- by 10-Foot Supersonic Wind Tunnel at the NASA Glenn Research Center, a future full test section characterization generated an ideal opportunity to design and build new characterization hardware to improve the understanding of the flow field, including flow quality, uniformity, and uncertainty in primary variables of interest. An array of flow sensing probes, referred to as the Characterization Array, was designed and built to replace 1960’s-era test section characterization hardware. Many references exist to guide wind tunnel characterization practitioners in the design of new hardware to properly measure various aspects of the flow within their wind tunnel facilities. Although reliable sources of information, these references tend to be over 30 years old and are not exhaustive. In scenarios where design decisions needed to be validated, computational simulations of the flow field around the characterization hardware were used. Decisions regarding probe location, probe spacing, and performance of various probes were justified using computational fluid dynamic simulations and rules-of-thumb from the legacy resources available in literature. This paper is intended to serve as an example of the benefits from integrating CFD into the design of wind tunnel hardware, particularly hardware for wind tunnel characterization.

CFD↗

Use of CFD in the Design of the 10- by 10-Foot Supersonic Wind Tunnel Characterization Array

At the 10- by 10-Foot Supersonic Wind Tunnel at the NASA Glenn Research Center, a future full test section characterization generated an ideal opportunity to design and build new characterization hardware to improve the understanding of the flow field, including flow quality, uniformity, and uncertainty in primary variables of interest. An array of flow sensing probes, referred to as the Characterization Array, was designed and built to replace 1960’s-era test section characterization hardware. Many references exist to guide wind tunnel characterization practitioners in the design of new hardware to properly measure various aspects of the flow within their wind tunnel facilities. Although reliable sources of information, these references tend to be over 30 years old and are not exhaustive. In scenarios where design decisions needed to be validated, computational simulations of the flow field around the characterization hardware were used. Decisions regarding probe location, probe spacing, and performance of various probes were justified using computational fluid dynamic simulations and rules-of-thumb from the legacy resources available in literature. This paper is intended to serve as an example of the benefits from integrating CFD into the design of wind tunnel hardware, particularly hardware for wind tunnel characterization.

CFD↗

Spectroscopy in the 10 keV to 10 MeV range

Spectral lines in the 10 keV to 1 MeV range carry information of fundamental importance on many astronomical objects. Since the lines are directly related to specific physical processes this information is model independent and gives the physical conditions in the objects. At the sensitivities achieved to date, approximately 0.0001 to 0.001 phsq cm. sec for steady sources and approximately 0.01 to 1 ph/sq cm sec for transient sources, lines were detected from the galactic center, gamma-ray bursts and transients, X-ray pulsators, the Crab pulsar and solar flares. Future instruments with a factor of approximately 100 sensitivity improvement will allow detailed spectroscopic study of these classes of objects as well as supernova remnants, active galaxies and the interstellar medium. This sensitivity improvement can be obtained through the use of detector technology already proven in balloon and satellite instruments.

Matteson, J. L.↗

Estimation of composition of cosmic rays with E sub zero approximately equals 10(17) - 10(18) eV

Fluctuations of the shower maximum depth obtained from analysis of electron and muon fluctuations and the extensive air showers (EAS) Cerenkov light on the Yakutsk array data and data of other arrays are considered. On the basis of these the estimation of composition of primaries with E sub 0 = 5.10 to the 17th power eV is received. Estimation of gamma-quanta flux with E sub 0 10 to the 17th power eV is given on the poor-muon showers.

Glushkov, A. V.↗

EAS development curve at energy of 10(16) - 10(18) eV measured by optical Cerenkov light

The data of optical Cerenkov light from extensive air shower observed at the core distance more than 1 Km at Akeno are reexamined. Applying the new simulated results, the shower development curves for the individual events were constructed. For the showers of 10 to 17th power eV the average depth at the shower maximum is determined to be 660 + or - 40 gcm/2. The shower curve of average development is found to be well described by a Gaisser-Hillas shower development function with above shower maximum depth.

Hara, T.↗

Low-noise behavior of InGaAs quantum-well-structured modulation-doped FET's from 10 to the -2nd to 10 to the 8 Hz

Equivalent gate noise voltage spectra of 1-micron gate-length modulation-doped FET's with pseudomorphic InGaAs quantum-well structure have been measured for the frequency range of 0.01 Hz to 100 MHz and commpared with the noise spectra of conventional AlGaAs/GaAs MODFET's and GaAs MESFET's. The prominent generation-recombination (g-r) noise bulge commonly observed in the vicinity of 10 kHz in conventional MODFET's at 300 K does not appear in the case of the new InGaAs quantum-well MODFET. Instead, its noise spectra indicate the presence of low-intensity multiple g-r noise components superimposed on a reduced 1/f noise. The LF noise intensity in the new device appears to be the lowest among those observed in any MODFET or MESFET. The noise spectra at 82 K in the new device represent nearly true 1/f noise. This unusual low-noise behavior of the new structure suggests the effectiveness of electron confinement in the quantum well that significantaly reduces electron trapping in the n-AlGaAs, and thus eliminates the g-r noise bulge observed in conventional MODFET's.

Liu, Shih-Ming J.↗

On the inability of magnetically constricted transition regions to account for the 10 to the 5th to 10 to the 6th K plasma in the quiet solar atmosphere

Static models of the plasma in the quiet solar atmosphere incorporating not only conduction and radiation but also the effects of large magnetic constrictions are examined. It is found that the bulk of the solar plasma at temperatures below 7 x 10 to the 5th K cannot be produced by a conductive transition region when it is modeled by flux tubes with constriction compatible with observations. The present findings suggest that the major portion of the UEV plasma may be maintained in an ensemble of small, individual magnetic loops located within the supergranular network and having peak temperatures ranging from chromospheric to coronal values.

Dowdy, James F., Jr.↗

Aerodynamics of Slender Bodies at Mach Number of 3.12 and Reynolds Numbers from 2 x 10(exp 6) to 15 x 10(exp 6) IV : Aerodynamic Characteristics of Series of Four Bodies Having Near-parabolic Noses and Cylindrical Afterbodies

Pressure distributions and forces for a series of four bodies of revolution having nose-fineness ratios varying from 4 to 10 have been obtained and compared with theory for a Mach number of 3.12, a Reynolds number range of 2x10(sup)6 to 14x10(sup)6, and angles of attack from zero to 9 degrees. In general, a comparison of the experimental data with a second-order theory showed good agreement for the range of variables investigated.

BODIES - FITNESS RATIO↗