Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind farms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

519 records · Page 29

Hawaii Fish Company Inc. Technical Assistance Voucher (Abstract)

For the past several years, the National Renewable Energy Laboratory (NREL), Sandia National Laboratories (SNL), and Pacific Northwest National Laboratory (PNNL) have provided technical assistance to the recipients of Department of Energy (DOE) -funded voucher programs, namely American-Made Challenges (AMC), the Incubator Program, and the Small Business Vouchers Program. Drawing on lessons learned and from first-hand experiences, NREL is leading a new holistic and streamlined voucher program aimed at strengthening ties between American innovators and the national labs. This new program, “Vouchers to Enable Laboratory and Organizational Collaboration for Innovation and Technology Improvements,” or VELOCITI, will leverage the successful elements of past programs, create administrative efficiencies, and enable the buildout of a national program to drive strong relationships between entrepreneurs and the national labs to accelerate the roll-out of new technologies in the US solar sector. This work will evaluate Hawaii Fish Company’s (HFC’s) floating renewable energy-powered aeration systems, designed primarily for aquaculture ponds, with crossover applications to farm ponds, reservoirs, and other water bodies. Notably, HFC’s systems include a variety of configurations, such as direct-solar systems, battery-storage systems, and systems with a secondary wind turbine option. HFC is planning to refine and commercialize their renewable energy aeration platforms. Presently, HFC is fabricating multiple configurations of the systems for deployment in multiple locations in the U.S. PNNL will apply technical expertise to assist in these goals, benefitting the industry partner by giving them an understanding of the performance of their systems. The technical objectives of this project are to understand system performance and reliability, determine a path toward certification, and model the performance of the systems in different locations.

99 GENERAL AND MISCELLANEOUS↗

Metatranscriptomics reveals a shift in microbial community composition and function during summer months in a coastal marine environment

Abstract Temperate coastal marine waters are often thermally stratified from spring through fall but can be dynamic and disrupted by tidal currents and wind‐driven upwelling. These mixing events introduce deeper, cooler water with a higher partial pressure of CO 2 (pCO2) and its associated microbial communities to the surface. Anecdotally, these events impact shellfish hatcheries and farms, warranting improved understanding of changes in composition and activity of marine microbial communities in relation to environmental processes. To characterize both compositional and functional changes associated with abiotic factors, here, we generate a reference metatranscriptome from the Strait of Georgia over representative seasons and analyze metatranscriptomic profiles of the microorganisms present within intake water containing different pCO 2 levels at a shellfish hatchery in British Columbia from June through October. Abiotic factors studied include pH, temperature, alkalinity, aragonite, calcite, and pCO 2 . Community composition changes were observed to occur at broad taxonomic levels and most notably to vary with temperature and pCO 2 . Functional gene expression profiles indicated a strong difference between early (June–July) and late summer (August–October) associated with viral activity. The taxonomic data suggest this could be due to the termination of cyanobacteria and phytoplankton blooms by viral lysis in the late season. Functional analysis indicated fewer differentially expressed transcripts associated with abiotic variables (e.g., pCO 2 ) than with the temporal effect. Microbial composition and activity in these waters vary with both short‐term effects observed alongside abiotic variation and long‐term effects observed across seasons. The analysis of both taxonomy and functional gene expression simultaneously in the same samples by environmental RNA (eRNA metatranscriptomics) provided a more comprehensive view for monitoring water bodies than either would in isolation.

Sutherland, Ben J. G.↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗

Modeling Assessment of Tidal Energy Extraction in the Western Passage

Numerical models have been widely used for the resource characterization and assessment of tidal instream energy. The accurate assessment of tidal stream energy resources at a feasibility or project-design scale requires detailed hydrodynamic model simulations or high-quality field measurements. This study applied a three-dimensional finite-volume community ocean model (FVCOM) to simulate the tidal hydrodynamics in the Passamaquoddy–Cobscook Bay archipelago, with a focus on the Western Passage, to assist tidal energy resource assessment. IEC Technical specifications were considered in the model configurations and simulations. The model was calibrated and validated with field measurements. Energy fluxes and power densities along selected cross sections were calculated to evaluate the feasibility of the tidal energy development at several hotspots that feature strong currents. When taking both the high current speed and water depth into account, the model results showed that the Western Passage has great potential for the deployment of tidal energy farms. The maximum extractable power in the Western Passage was estimated using the Garrett and Cummins method. Different criteria and methods recommended by the IEC for resource characterization were evaluated and discussed using a sensitivity analysis of energy extraction for a hypothetical tidal turbine farm in the Western Passage.

16 TIDAL AND WAVE POWER↗

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

Economic dispatch of offshore renewable energy resources for islanded communities with optimal storage sizing

Coastal or isolated microgrids depend on diesel generators and could benefit from renewable energy resources, especially offshore wind and wave energy. Integrating these resources into microgrids is complicated by their high intermittency, which requires optimal economic dispatch to effectively evaluate. This study considers three coastal or islanded sites, and uses mid-fidelity models of wind and wave energy technologies, and local demand data to solve the optimal economic dispatch problem. An optimal storage sizing method is developed that finds the smallest capacity of energy storage required to meet the microgrid load during each season. The storage capacity decreases by a factor of two at most when adding wave energy converters to a system. Adding wave energy converters to a farm decreases cost by about 30%. Furthermore, the required storage size varies by two to three times from summer to winter. Compared with the state-of-the-art approaches that often overlook realistic offshore renewable energy technology in microgrid economic dispatch and optimal storage sizing, the proposed solution introduced in this study allows for better site selection, microgrid design, converter selection, and storage sizing considerations for isolated microgrids.

16 TIDAL AND WAVE POWER↗

Optimal Design of Sustainable Ammonia-Based Food–Energy–Water Systems with Nitrogen Management

As the basis for virtually any form of nitrogen fertilizers, ammonia plays a vital role in agriculture; in addition, there has been an increased interest in its use as a carbon-free energy carrier. However, ammonia is also associated with two major environmental concerns: CO 2 emissions from the conventional production process and nitrogen pollution from the excessive use of ammonia-based fertilizers. To mitigate these environmental impacts, we develop an optimization framework for the design of a sustainable ammonia-based agricultural system that synergistically integrates the production of ammonia from renewable resources and effective measures for nitrogen management. The proposed model captures the effect of intermittency by incorporating both design and detailed operational decisions. Here, by applying a multiscale time representation that reduces the problem size and a tailored surrogate model that accurately approximates model nonlinearity, we are able to achieve optimal solutions within reasonable computation times. A computational case study is conducted using real-world data from a local farm in Morris, Minnesota, and the results indicate the trade-off between cost and nitrogen loss. Importantly, we show that practicing effective nitrogen management can significantly reduce the nitrogen loss with only a small increase in net present cost.

10 SYNTHETIC FUELS↗

Exploring Micro-Environmental Conditions of Urban Agrivoltaics: Advancing Sustainable Green Spaces and Agriculture in Temperate Cities

Agrivoltaics, the integrated land use combining renewable energy production and agriculture, can potentially address key challenges faced by urban communities, including limited access to vacant land, fresh produce, and electricity. However, urban agrivoltaics has rarely been considered a viable solution, primarily due to a lack of experimental systems demonstrating the functionality of urban food production or green spaces alongside solar energy production. To evaluate the potential of solar photovoltaics to help mitigate heat stress on urban agriculture and green spaces in a temperate climate, we examined the microclimatic changes introduced by an urban agrivoltaics system (UrAV) when combined with vegetable crops and turfgrass, respectively. Accordingly, we installed an experimental setup instrumented with environmental sensors to compare full-sun conditions with those of an agrivoltaics system designed for urban environments. We found minimal differences for both land cover types between the control and agrivoltaics sites in air and soil temperature. However, during periods of intensified summer heat, temperatures beneath the panels cooled due to reductions in wind speed and relative humidity, which impeded the movement of hot, moist air and reduced reference evapotranspiration. Further, soil moisture in UrAV was highly spatially heterogeneous, influenced by the layout of the photovoltaic panels and their support structure, which redistributed rainfall and controlled where solar radiation could penetrate and drive evapotranspiration. Overall, our results suggest that PV-induced environmental changes in temperate climates are compatible with cultivating turfgrass or appropriate crops. These findings can help planners and designers integrate agrivoltaics into community gardens, farms, and green spaces in temperate cities.

14 SOLAR ENERGY↗

Halau Uma: Kahikinui Community Cultural, Educational, and Resilience Center Preliminary Design Technical Assistance Summary Report

The Kahikinui Homestead Community in Maui faces energy resilience challenges due to its remote, off-grid location. This report summarizes preliminary technical assistance to design a microgrid for six modular homes using solar PV, wind, and battery storage. Results indicate that a hybrid PV and battery system, supplemented by small wind turbines, offers a cost-effective, resilient solution supporting energy independence and disaster preparedness.

Quiroz, Jimmy Edward [Sandia National Laboratories↗

Kauhale 'O Kipapa: Kahikinui Community Cultural, Educational, and Resilience Center Preliminary Design Technical Assistance Summary Report

The Kahikinui Homestead Community in Maui faces energy resilience challenges due to its remote, off-grid location. This report summarizes preliminary technical assistance to design a microgrid for six modular homes using solar PV, wind, and battery storage. Findings show hybrid PV and battery systems, supplemented by small wind turbines, offer cost-effective, resilient solutions. This work supports enhanced energy independence and disaster preparedness for the community.

Quiroz, Jimmy Edward [Sandia National Laboratories↗

Blue Rock CropSpanPV - Low Cost Racking for Agricultural Solar Photovoltaics

In this work, a total of four solar panel layouts, applied to Agrivoltaics, are investigated. This study presents two hypotheses: 1. Prefabrication - Lower total cost can be achieved by constructing a pre-assembled, pre-wired solar array in a factory, with automation, then rapidly deploying it in the field. 2. Tension Structures - Using tension structures in a way to suspend an overhead solar array also reduces costs when compared to conventional support methods. Designs are presented for frames to hold the panels. Configurations are advanced to connect the frames into arrays. Supports and foundations to hold the arrays in the desired layout are calculated, selected and presented. Cost models are prepared for the four layouts, which include definition of the business enterprise, the manufacturing operation, and the required facility for production at scale. Cost models include, detail material and task/labor take-offs for both manufacturing and installation. Comparisons with conventional system adapted to Agrivoltaics reveal that the two hypotheses do not hold true. A prefabricated array requires additional material that is not needed in the base system and the cost of this additional material is not outweighed by the cost savings of reduced field installation. The cost of wire rope for a tension structure does result in an economy of material, however, the cost of end connections and tensioning devices adds significantly to the cost of the overall tension structure. Foundation loads with tension structures, especially the large wind uplift seen with a fixed tilt solar array, impose significant constraints and high costs. The following conclusions are recommended for further consideration: 1. Best Case Agrivoltaic Configuration - The best value/lowest cost configuration for agrivoltaics is the installation of solar panels mounted on a single axis tracker in either a 2-in-portrait or 2-in landscape arrangement. This is useful for grazing lands and for staple crops which require high light levels. These applications represent the vast majority of the potential agrivoltaic market. Important elements in this configuration are the specific geometric layout coordinated with the various field operations and a control system linked between the farm equipment and single axis tracker. The control system is to monitor location and orientation, then actively tilt the solar panels or brake the field equipment to provide clearance and avoid collisions. 2. Long Span Applications - The use of tension structures for an overhead fixed tilt array is beneficial where long spans are a necessity, especially where the base support in the project location has consolidated rock near the surface or some other solid structure. One application is spanning wide irrigation canals. Another may be as an installation at the top deck of parking structures. 3. Direct Ground Mount Configuration – Having skids at the base of a pre-fabricated array that extend when the array is deployed, could be a successful design. This could be a useful strategy for dense, flat, ground-mount configurations like that employed by a couple of successful commercial operations (5G Maverick and Erthos). Arrays would be orientated north and south, deployed very low on prepared grade. Arrays would be aligned closely next to each other and anchored with small ground screws or simply with ballast. This same product arrangement could be very useful for rapid deployment and set-up of solar arrays for temporary deployments, disaster response and the military operations

14 SOLAR ENERGY↗

DOE Hanford Tank Side Cesium Removal System (TSCR) Update: Fabrication and Factory Acceptance Testing - 20300

The Tank Side Cesium Removal (TSCR) System is a modular, quickly-deployable, and passively safe system for efficiently removing solids and cesium from alkaline liquid waste raffinate created by fuel processing on the Hanford site. This paper provides an overview of the project with particular emphasis on completion of fabrication and factory acceptance testing (FAT). All TSCR System components are inside three enclosures known as the Process Enclosure, Ancillary Enclosure, and Control Enclosure. The Process Enclosure is seismic design category II (SDC-II) and built to withstand the rigors of transportation and lifting, high winds, volcanic ash fall, and heavy precipitation (snow) over a temperature range of -25 to 115 deg. F. The Process Enclosure and Control Enclosure were fabricated in AVANTech's Columbia, SC facility, while the Ancillary Enclosure was fabricated in AVANTech's Richland, WA facility. The design and preliminary documented safety analysis were completed in December 2019, with all work being performed in accordance with ASME NQA-1 quality assurance requirements. The Process Enclosure, Ion Exchange Columns (IXCs), and several other TSCR components have a nuclear safety function and are designated as safety significant structures, systems, and components (SS-SSCs). The NQA-1 Commercial Grade Dedication (CGD) process was used to identify critical characteristics in order to accept materials and items used for fabrication of several safety significant TSCR components. This paper also addresses unique aspects and challenges of implementing CGD in DOE facilities and systems. After fabrication and preliminary testing, the Process and Control Enclosures were shipped to AVANTech's Richland facility where the complete TSCR System was setup and connected in a represented layout and configuration that will be used on the Hanford site. Test tanks and pumps were put in place and connected to the TSCR Process Enclosure in a manner that mimicked interfacing Double Shell Tanks in the 241-AP Tank Farm. The TSCR System was then tested/operated under conditions equivalent to those planned for onsite operation. Testing was separated into five separate phases as defined below: - Phase 1: Confirmation of TSCR System readiness for the FAT; - Phase 2: Verification of TSCR System operation under standard conditions; - Phase 3: Demonstration of TSCR System operation under non-standard conditions; - Phase 4: Demonstration of ion exchange media removal from an IXC; and - Phase 5: Completion of TSCR System lift plans and site mobilization. The Hanford Tank Operations Contractor, Washington River Protection Solutions (WRPS), participated in all phases of testing. Testing at AVANTech's Richland Facility allowed WRPS personnel to familiarize themselves with TSCR operations in a radiologically clean facility prior to onsite mobilization. Engineering and operations personnel gained valuable experience that allowed them to better refine onsite operational protocols and procedures - including handling and movement of IXCs with a forklift. This paper describes the technologies used by the TSCR System as well as how these technologies are deployed and operated to advance the Hanford mission of safely, efficiently, and effectively treating tank waste. It also provides detailed information on fabrication and FAT, including operational data from simulated tank waste runs. A project schedule for WRPS' planned construction acceptance testing, operational acceptance testing, and actual tank waste treatment is provided. This presentation should be of great interest to parties responsible for the design, testing, and mobilization of modular NQA-1 technologies for the treatment of raffinate and similar liquid wastes containing high concentrations of radioactive cesium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

FORCE Update 2024

The Framework for Optimization of Resources and Economics (FORCE) tool suite is the U.S. Department of Energy’s Nuclear Integrated Energy Systems (IES) Program flagship tool suite for technoeconomic IES analysis of IES. This tool suite is useful for analysis designed to evaluate and improve the technoeconomics of energy production systems, particularly for systems including nuclear technology. In this report, we document the development activity for the FORCE tool suite to extend its capabilities as performed during fiscal year 2024. In addition to reliability and accessibility, capability is one of the three standards guiding the development of the FORCE tool suite and the software codes that are its constituent parts. Extending the capabilities of the FORCE tool suite allows analysis both within the IES program as well as industry, university, and laboratory partners to perform analysis with more accuracy, insight, and impactful narrative. Four areas of capability development were the focus of activity this year: economic parameter uncertainty quantification, multiresolution analysis, components-to-optimization workflow automation, and statespace construction workflows for real-time optimal control. In economic parameter uncertainty quantification, the ability of HERON to capture risk due to scenarios (weather and energy demand uncertainty) was expanded to also include uncertainties in financial parameters such as capital cost or operation and maintenance costs. By including these sources of uncertainty, which are sometimes very large compared with scenario uncertainty, HERON is better able to capture the risk posed by investment in various IES technology. Because of this, analysts can also consider the reduction in risks that can be realized by choice of some technologies. In multiresolution analysis, development activity extended on work completed previously. In fiscal year 2023, methods for decomposing time series signals, such as demand, solar and wind availability, and price profiles, were analyzed and down-selected to those most effective at splitting signals into different resolutions. These resolutions allow considering the influence of different energy demand and supply behaviors across different time scales. For example, energy demand might be divided into seasonal, weekly, and hourly profiles. In fiscal year 2024, this preliminary work was extended and implemented within the Risk Analysis Virtual Environment (RAVEN) risk and uncertainty analysis platform, which is used throughout the FORCE framework. This development of the “multi-resolution time series analysis” (MR-TSA) module in RAVEN allows training synthetic history generators on complex time series. These synthetic history generators can then be used in HERON for generating scenarios that represent possible market and weather scenarios that can be analyzed on different time scales. We envision completing this work in the future, implementing multiresolution dispatch optimization strategies that can make the most beneficial use of these stratified time histories. In components-to-optimization workflow development, workflows for translating user inputs of components into algorithms for algebraic optimization were selected and implemented. Similar algorithms within the Holistic Energy Resource Optimization Network (HERON) were separated from the main code base of HERON and gathered with the components-to-optimization workflows in the new Dispatch Optimization Variable Engine (DOVE) software library. This modularization allows FORCE users to analyze dispatch optimization and energy system duty cycles independently of HERON, which previously was a burdensome task. Additionally, these dispatch optimization algorithms, set up in an independent library, can now be used across all software applications within FORCE, especially including the real-time optimal control software Optimization of Real-time Capacity Allocation (ORCA). Allowing FORCE software to share dispatch optimization algorithms within a single library allows for improved software maintenance and reliability. In statespace characterization workflow development, alternative workflows for optimizing dispatch with additional technical accuracy was the focus, particularly to improve the real-time optimization decision making in ORCA. Using algorithms and workflows initially developed for the Feasible Actuator Range Modifier (FARM), workflows for determining the statespace representation of IES were identified and demonstrated. The resulting dispatch optimization required a more robust optimization algorithm than that originally used in HERON (and moved to DOVE), which required adding an alternate workflow to DOVE that can more accurately match the behavior of physical systems using a partial differential equation representation. In conclusion, capability developments in the FORCE tool suite in fiscal year 2024 have improved the ability of the FORCE tool suite to perform

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Irrigation Modernization Task 4: Accelerating Energy Solutions (FY2022 Final Report)

This report offers insights on energy solutions for irrigation modernization that serve the needs of farmers as well as residents and industry in the local community. Solutions are found in the irrigation districts where local generation from renewable energy sources – solar, hydro, and wind – can be combined with energy storage and customer loads. These combined resources configured in microgrids can lower costs during peak loads and provide resiliency by maintaining electricity supply during outages. The goal of this project, as stated in the FY2022 AOP, is to promote realization of energy solutions that are tailored to physical location, community, infrastructure, and energy value streams. Further, it is to develop examples of how to increase value of, and overcome barriers to, energy solutions in the context of irrigation modernization. In pursuit of that goal, the project looked at options for: 1) Reducing the cost of energy consumed in irrigation systems, 2) Increasing the revenue from surplus power generation, and 3) Deploying new power generation configured as part of a local microgrid. Potential solutions to reducing energy costs and increasing surplus power revenue revolve around addressing regulatory and legal constraints tied to how power is purchased by and sold to the irrigator or irrigation district. Some headway was made in identifying barriers and ways to push utilities to be more accommodating to distributed energy sources; however, for the most part, real progress hinges on changes at the regulatory and legislative level. Deployment of local, renewable generation systems can be implemented provided the economics of the project and the location are favorable. In concert with Famers Conservation Alliance and Energy Trust of Oregon, a number of approaches were studied in the past year, including off-grid solar powered pumps, grid-tied community solar projects, and in-conduit canal hydropower systems. Ultimately three viable projects were identified: 1) North Unit Irrigation District/City of Redmond, Oregon Critical Facility Microgrid – offers combined in-conduit hydro and solar power generation. 2) Wallowa County/Joseph, Oregon Irrigation System Upgrades – centered on upgrades to a non-powered dam that will add a turbine as well as in-conduit power in canal feeders downstream. 3) Medford, Oregon Wastewater Treatment Plant Biogas Cogeneration System – centered on building out biogas storage and grid upgrades to power the plant, sell excess power, and provide emergency backup power (supplanting a diesel generator). Each of these projects has characteristics that broaden the understanding of the value of microgrids employing renewable energy to achieve resiliency and net-zero carbon goals. The first two projects are centered on new hydropower systems. Although the Medford project is only tangentially tied to an irrigation district, it was selected for study analysis as it was the only one mature enough (with sufficient data) to complete an analysis within this project year. Thus, we chose to move forward developing a case study, in concert with the Community Water-Power Resilience project, to demonstrate a method for evaluating such projects. Essentially, this case study serves as a template for studies to be carried out next year that more directly involve irrigation system hydropower, e.g., the project at the Wallowa County/Joseph, Oregon Irrigation System. Lastly, it is recognized that the locations and case studies in this report are all located in Oregon. We recognize this as a limitation. While the intent is not to ignore other states or regions, this result is driven by the fact that we have cultivated a collaboration with non-profit entities in Oregon that focus on these topics – Farmers Conservation Alliance and Energy Trust of Oregon. These partners were central to identifying projects that may be good fits for this program. A goal in the coming year is to establish collaboration with entities in other states/regions that, similarly, can connect us to potential projects in their geographic area. The potential benefits from the WPTO’s support for demonstration projects as energy solutions in irrigation districts include: (1) Alternative power supplies for communities and farms using renewable, carbon-free energy resources, (2) Cost savings for electricity for communities and farms, (3) Resiliency of power supplies for critical loads when electricity from the grid is not available, (4) Resiliency of power supplies for critical infrastructure in the event of catastrophic events, and (5) Demonstration of irrigation modernization projects that provide resilience and a reduced carbon footprint to irrigation districts and nearby communities. These deployments can serve as vanguards/archetypes spurring similar projects in other districts and states.

13 HYDRO ENERGY↗