Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

First drop dissimilarity in drop-on-demand inkjet devices

As inkjet printing technology is increasingly applied in a broader array of applications, careful characterization of its method of use is critical due to its inherent sensitivity. A common operational mode in inkjet technology known as drop-on-demand ejection is used as a way to deliver a controlled quantity of material to a precise location on a target. This method of operation allows ejection of individual or a sequence (burst) of drops based on a timed trigger event. This work presents an examination of sequences of drops as they are ejected, indicating a number of phenomena that must be considered when designing a drop-on-demand inkjet system. These phenomena appear to be driven by differences between the first ejected drop in a burst and those that follow it and result in a break-down of the linear relationship expected between driving amplitude and drop mass. This first drop, as quantified by high-speed videography and subsequent image analysis, can be different in morphology, trajectory, velocity, and volume from subsequent drops within a burst. These findings were confirmed orthogonally by both volume and mass measurement techniques which allowed quantitation down to single drops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-C-9A-03: Simultaneous Deconvolution and Segmentation for PET Tumor Delineation Using a Variational Method

Purpose: To implement a new method that integrates deconvolution with segmentation under the variational framework for PET tumor delineation. Methods: Deconvolution and segmentation are both challenging problems in image processing. The partial volume effect (PVE) makes tumor boundaries in PET image blurred which affects the accuracy of tumor segmentation. Deconvolution aims to obtain a PVE-free image, which can help to improve the segmentation accuracy. Conversely, a correct localization of the object boundaries is helpful to estimate the blur kernel, and thus assist in the deconvolution. In this study, we proposed to solve the two problems simultaneously using a variational method so that they can benefit each other. The energy functional consists of a fidelity term and a regularization term, and the blur kernel was limited to be the isotropic Gaussian kernel. We minimized the energy functional by solving the associated Euler-Lagrange equations and taking the derivative with respect to the parameters of the kernel function. An alternate minimization method was used to iterate between segmentation, deconvolution and blur-kernel recovery. The performance of the proposed method was tested on clinic PET images of patients with non-Hodgkin's lymphoma, and compared with seven other segmentation methods using the dice similarity index (DSI) and volume error (VE). Results: Among all segmentation methods, the proposed one (DSI=0.81, VE=0.05) has the highest accuracy, followed by the active contours without edges (DSI=0.81, VE=0.25), while other methods including the Graph Cut and the Mumford-Shah (MS) method have lower accuracy. A visual inspection shows that the proposed method localizes the real tumor contour very well. Conclusion: The result showed that deconvolution and segmentation can contribute to each other. The proposed variational method solve the two problems simultaneously, and leads to a high performance for tumor segmentation in PET. This work was supported in part by National Natural Science Foundation of China (NNSFC), under Grant Nos. 60971112 and 61375018, and Fundamental Research Funds for the Central Universities, under Grant No. 2012QN086. Wei Lu was supported in part by the National Institutes of Health (NIH) Grant No. R01 CA172638.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-91: Sparing Lung Function in Treatment Planning Using Dual Energy Tomography

Purpose: To propose an alternate treatment plan that minimizes the dose to the functional lung tissues. In clinical situation, the evaluation of the lung functionality is typically derived from perfusion scintigraphy. However, such technique has spatial and temporal resolutions generally inferior to those of a CT scan. Alternatively, it is possible to evaluate pulmonary function by analysing the iodine concentration determined via contrast-enhanced dual energy CT (DECT) scan. Methods: Five lung cancer patients underwent a scintigraphy and a contrast-enhanced DECT scan (SOMATOM Definition Flash, Siemens). The iodine concentration was evaluated using the two-material decomposition method to produce a functional map of the lung. The validation of the approach is realized by comparison between the differential function computed by DECT and scintigraphy. The functional map is then used to redefine the V5 (volume of the organ that received more than 5 Gy during a radiotherapy treatment) to a novel functional parameter, the V5f. The V5f, that uses a volume weighted by its function level, can assist in evaluating optimal beam entry points for a specific treatment plan. Results: The results show that the differential functions obtained by scintigraphy and DECT are in good agreement with a mean difference of 6%. In specific cases, we are able to visually correlate low iodine concentration with abnormal pulmonary lung or cancerous tumors. The comparison between V5f and V5 has shown that some entry points can be better exploited and that new ones are now accessible, 2.34 times more in average, without increasing the V5f - thus allowing easier optimization of other planning objectives. Conclusion: In addition to the high-resolution DECT images, the iodine map provides local information used to detect potential functional heterogeneities in the 3D space. We propose that this information be used to calculate new functional dose parameters such as the V5f. The presenting author, Andreanne Lapointe, received a canadian scholarship from MITACS. Part of the funding is from the compagny Siemens.

60 APPLIED LIFE SCIENCES↗

AGR-1 Compact 4-1-1 Post-Irradiation Examination Results

Destructive post-irradiation examination was performed on AGR-1 fuel Compact 4-1-1, which was irradiated to a final compact-average burnup of 19.4% FIMA (fissions per initial metal atom) and a time-average, volume-average temperature of 1072°C. The analysis of this compact focused on characterizing the extent of fission product release from the particles and examining particles to determine the condition of the kernels and coating layers. The work included deconsolidation of the compact and leach-burn-leach analysis, visual inspection and gamma counting of individual particles, metallurgical preparation of selected particles, and examination of particle cross-sections with optical microscopy, electron microscopy, and elemental analysis. Deconsolidation-leach-burn-leach (DLBL) analysis revealed no particles with failed TRISO or failed SiC layers (as indicated by very low uranium inventory in all of the leach solutions). The total fractions of the predicted compact inventories of fission products Ce-144, Cs-134, Cs-137, and Sr-90 that were present in the compact outside of the SiC layers were <2×10 -6 , based on DLBL data. The Ag-110m fraction in the compact outside the SiC layers was 3.3×10 -2 , indicating appreciable release of silver through the intact coatings and subsequent retention in the OPyC layers or matrix. The Eu-154 fraction was 2.4×10 -4 , which is equivalent to the inventory in one average particle, and indicates a small but measurable level of release from the intact coatings. Gamma counting of 61 individual particles indicated no particles with anomalously low fission product retention. The average ratio of measured inventory to calculated inventory was close to a value of 1.0 for several fission product isotopes (Ce-144, Cs-134, and Cs-137), indicating good retention and reasonably good agreement with the predicted inventories. Measured-to-calculated (M/C) activity ratios for fission products Eu-154, Eu-155, Ru-106, Sb-125, and Zr-95 were significantly less than 1.0. However, as no significant release of these fission products from compacts was noted during previous analysis of the AGR-1 capsule components, the low M/C ratios are most likely an indication of a bias in the inventories predicted by physics simulations of the AGR-1 experiment. The distribution of Ag-110m M/C ratios was centered on a value of 1.02 and was fairly broad (standard deviation of 0.18, with values as high as 1.42 and as low as 0.68). Based on all data gathered to date, it is believed that silver retention in the particles was on average relatively high, but that the broad distribution in values among the particles represents significant variation in the inventory of Ag-110m generated in the particles. Ceramographic analysis of particle cross-sections revealed many of the characteristic microstructures often observed in irradiated AGR-1 particles from other fuel compacts. Palladium-rich fission product clusters were observed in the IPyC and SiC layers near the IPyC-SiC interface of three Compact 4-1-1 particle cross-sections. In spite of the presence of fission product clusters in the SiC layer, no significant corrosion or degradation of the layer was observed in any of the particles examined.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Linking void and interphase evolution to electrochemistry in solid-state batteries using operando X-ray tomography

Despite progress in solid-state battery engineering, our understanding of the chemo-mechanical phenomena that govern electrochemical behavior and stability at solid-solid interfaces remains limited compared to solid-liquid interfaces. Here, we use operando synchrotron X-ray computed microtomography to investigate the evolution of lithium/solid-state electrolyte interfaces during battery cycling, revealing how the complex interplay among void formation, interphase growth, and volumetric changes determines cell behavior. Void formation during lithium stripping is directly visualized in symmetric cells, and the loss of contact that drives current constriction at the interface between lithium and the solid-state electrolyte (Li10SnP2S12) is quantified and found to be the primary cause of cell failure. The interphase is found to be redox-active upon charge, and global volume changes occur due to partial molar volume mismatches at either electrode. Finally, these results provide new insight into how chemo-mechanical phenomena can impact cell performance, which is necessary to understand for the development of solid-state batteries.

42 ENGINEERING↗

Remotely deployable aerial inspection using tactile sensors

For structural monitoring applications, the use of remotely deployable Non-Destructive Evaluation (NDE) inspection platforms offer many advantages, including improved accessibility, greater safety and reduced cost, when compared to traditional manual inspection techniques. The use of such platforms, previously reported by researchers at the University Strathclyde facilitates the potential for rapid scanning of large areas and volumes in hazardous locations. A common problem for both manual and remote deployment approaches lies in the intrinsic stand-off and surface coupling issues of typical NDE probes. The associated complications of these requirements are obviously significantly exacerbated when considering aerial based remote inspection and deployment, resulting in simple visual techniques being the preferred sensor payload. Researchers at Bristol Robotics Laboratory have developed biomimetic tactile sensors modelled on the facial whiskers (vibrissae) of animals such as rats and mice, with the latest sensors actively sweeping their tips across the surface in a back and forth motion. The current work reports on the design and performance of an aerial inspection platform and the suitability of tactile whisking sensors to aerial based surface monitoring applications.

60 APPLIED LIFE SCIENCES↗

Three-Dimensional Single-Molecule Localization Microscopy in Whole-Cell and Tissue Specimens

Super-resolution microscopy techniques are versatile and powerful tools for visualizing organelle structures, interactions, and protein functions in biomedical research. However, whole-cell and tissue specimens challenge the achievable resolution and depth of nanoscopy methods. We focus on three-dimensional single-molecule localization microscopy and review some of the major roadblocks and developing solutions to resolving thick volumes of cells and tissues at the nanoscale in three dimensions. These challenges include background fluorescence, system- and sample-induced aberrations, and information carried by photons, as well as drift correction, volume reconstruction, and photobleaching mitigation. We also highlight examples of innovations that have demonstrated significant breakthroughs in addressing the abovementioned challenges together with their core concepts as well as their trade-offs.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of Lake Ice Biases in Reanalysis Data on Downscaled Climate Simulations over the Great Lakes Region

This data package contains observation-based and model-simulated datasets (all provided in NetCDF format) for evaluating how wintertime lake-ice representation affects regional weather and climate over the Laurentian Great Lakes (freshwater lake ecosystem) during the high–ice-cover winter of 2009. The observational component includes: (1) Stage IV gridded precipitation at 4 km, hourly resolution for January–February 2009 over the Great Lakes region (radar–gauge multisensor precipitation analyses); (2) Great Lakes Surface Environmental Analysis (GLSEA) satellite-derived lake-ice coverage at 1.3 km, daily resolution for the 2009 winter months, providing ice coverage over Lakes Superior, Michigan, Huron, Erie, and Ontario; and (3) in situ measurements at the Standard Rock site on Lake Superior from the Great Lakes Evaporation Network (GLEN) at hourly resolution, including near-surface atmospheric variables and sensible and latent heat fluxes (air–lake exchange) at a fixed point location. The modeling component provides corresponding fields from two simulations, both archived at 4 km, hourly resolution: a standalone Weather Research Forecasting model (WRF) run driven by the European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis 5 (ERA5), and a two-way coupled model using WRF and the Finite Volume Community Ocean Model (WRF-FVCOM, a 3-D hydrodynamic lake model). These outputs include variables relevant to air–lake interaction and lake-effect processes (e.g., near-surface temperature, humidity, wind, precipitation, and surface turbulent fluxes), enabling direct comparison with the observational datasets. Users can analyze and visualize these NetCDF files with common tools such as Python (e.g., xarray, netCDF4, numpy, pandas), NCO/CDO, Panoply, or ncview; NetCDF variables can also be converted to other formats (e.g., CSV, GeoTIFF) using these utilities.

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC TEMPERATU↗

ISMB Conference Proceedings

This special issue comprises the papers accepted for presentation at the 19th Annual International Conference on Intelligent Systems for Molecular Biology, joint with the 10th European Conference on Computational Biology, an official conference of the International Society for Computational Biology (ISCB; http://www.iscb.org). ISMB/ECCB 2011 (http://www.iscb.org/ismb2011/) will take place in Vienna, Austria, from July 17 through July 19, 2011; preceded during July 14–16 by eight 1- or 2- day Special Interest Group (SIG) meetings, three satellite meetings and nine half-day tutorials; and followed by two additional satellite meetings. The 48 papers in this volume were selected from 258 submitted papers. Submitted papers were assigned to 13 areas. Area Chairs led each topic area by selecting their area's program committee and overseeing the reviewing process. Many Area Chairs were new compared to 2010, and two completely new areas were added in 2011, ‘Data Visualization’ and ‘Mass Spectrometry and Proteomics’. Six papers for which Area Chairs were in conflict were reviewed under a ‘Conflicts Management’ section headed by the Proceedings Chairs; one such paper was accepted in ‘Bioimaging’. Areas, co-chairs and acceptance information are listed in Table 1. Compared to prior years, five mature topic areas had steady submissions, ‘Evolution and Comparative Genomics’, ‘Gene Regulation and Transcriptomics’, ‘Protein Structure and Function’, ‘Sequence Analysis’, ‘Text Mining’. Two areas newer to ISMB were underrepresented this year, ‘Bioimaging’ and ‘Disease Models and Epidemiology’. One area doubled, ‘Applied Bioinformatics’, renamed from last year's ‘Other Bioinformatics Applications’; and one tripled, ‘Protein Interactions and Molecular Networks’. Across the areas, 326 members of the bioinformatics community provided reviews. Most papers received three reviews and several received four or more. There was significant discussion of the merits of the papers first between referees and the Area Chairs, and then between Area Chairs and the proceedings chairs. Initial decisions to accept papers were made during a comprehensive conference call with the Area Chairs, and several papers underwent a further evaluation by additional Area Chairs before acceptance decisions were finalized. We appreciate that in several cases reviewers' opinions might have changed with additional input or further clarifications from the authors; because the ISMB/ECCB 2011 timeline did not allow for a second round of reviews, however, only papers where referees suggested minor revisions could be accepted. For several papers where referee comments might have been unclear to the authors, Area Chairs added additional comments and explanations. In total, 48 papers were conditionally accepted, pending revision. After acceptance notices were sent, the authors had 2 weeks to modify their papers according to the suggestions made by the reviewers and to respond to the reviewers' comments. Modified papers and authors' responses were reexamined during the next week to ensure each paper was modified appropriately in response to the reviewers' comments. We were pleased that all 48 conditionally accepted papers were finally accepted for the conference. The final acceptance rate was 19%, similar to the rates of 20% and 19% in the two prior years. Collectively, the 48 accepted papers had 185 authors from 18 countries across 6 continents, with 82 authors from North America, 54 from Europe, 25 from Asia (excluding Israel), 10 from Israel, 9 from Australia, 4 from South America and 1 author from Africa. We thank the area chairs and reviewers for their hard work and dedication to maintaining a professional review process. We thank all authors of submitted papers and authors of accepted papers for their diligences in responding to reviewer comments within 2 weeks. We thank Steven Leard's team for extensive technical support with the EasyChair submission and reviewing system; Mona Singh and Joel S. Bader for sharing their experience from last year; the team at Oxford University Press for typesetting the papers; Conference Chairs Burkhard Rost, Michal Linial, Peter Schuster and Kurt Zatloukal, as well as the ISMB/ECCB 2011 Steering Committee, for their valuable input; and Steven Leard for helping us oversee the process.

60 APPLIED LIFE SCIENCES↗

SORTIE DB - Source term integrated environmental management disposal facility database - 15249

The Environmental Management Disposal Facility (EMDF) in Oak Ridge, Tennessee, is a proposed U.S. Department of Energy low-level Comprehensive Environmental Response Compensation and Liability Act (CERCLA) waste disposal facility with an operational start in the early 2020's. As a DOE low-level waste disposal facility, it is subject to DOE Order 435.1, requiring a composite analysis and possibly a performance assessment. The Source Term Integrated EMDF Data Base - SORTIE DB - provides source term estimates used in these assessments. An Oak Ridge Office of Environmental Management (OREM) Federal and Contractor team developed this state-of-the-art descriptive analytics and visualization schema. DOE OREM senior management has recognized complementary beneficial uses of SORTIE DB in decisions for accelerating clean-up progress, dealing with conflicting sequencing and budget priorities, and enhancing stakeholder and regulatory interfaces. SORTIE DB is designated as an OREM planning tool. SORTIE DB contains estimated forecast waste volumes and masses for over 800 Decontamination and Decommissioning (D and D) and Remedial Action (RA) sequenced baseline packages over the next 25+ years. Available characterization data, radionuclide identification and concentrations, and data from safety basis and emergency management documents are incorporated into SORTIE DB. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-229: Magnetic Resonance Imaging of Small Fiducial Markers for Proton Beam Therapy

Purpose: For proton beam therapy, small fiducial markers are preferred for patient alignment due to less interference with the proton beam. Visualizing small fiducial markers can be challenging in MRI. This study intends to investigate MRI imaging protocols for better visualization of small fiducial markers. Methods: Two carbon and two coil-shaped gold markers were placed into a gel phantom. Both carbon markers had a diameter of 1mm and a length of 3mm. Both gold markers had a length of 5mm. One gold marker had a diameter of 0.5mm and the other had a diameter of 0.75mm. T1 VIBE, T2 SPACE, TrueFISP and susceptibility weighted (SW) images were acquired. To improve marker contrast, high spatial resolution was used to reduce partial volume effect. Slice thickness was 1.5mm for all four sequences and in-plane resolution was 0.6mm for TrueFISP, 0.7mm for T1 VIBE, and 0.8mm for T2 SPACE and SW. For comparison purpose, a 3D T1 VIBE image set at 3mm slice thickness and 1.2mm in-plane resolution was also acquired. Results: All markers were visible in all high-resolution image sets. In each image set, marker-induced signal void was the smallest (in diameter) for carbon markers, followed by the 0.5mm gold marker and the largest for the 0.75mm gold marker. The SW images had the largest marker-induced signal void. However, those might be confused by susceptibility-gradient-induced signal voids. T1 VIBE had good visualization of markers with nicely defined edges. T2 SPACE had reasonable visualization of markers but edges were slightly blurred. TrueFISP had good visualization of markers only if they were not masked by banding artifacts. As a comparison, all markers were hardly visible in the standard resolution T1 VIBE images. Conclusion: 3D high-resolution T1 VIBE and SW have great potential in providing good visualization of small fiducial markers for proton beam therapy.

60 APPLIED LIFE SCIENCES↗

A spatially encoded dose difference maximal intensity projection map for patient dose evaluation: A new first line patient quality assurance tool

Purpose: To develop a spatially encoded dose difference maximal intensity projection (DD-MIP) as an online patient dose evaluation tool for visualizing the dose differences between the planning dose and dose on the treatment day. Methods: Megavoltage cone-beam CT (MVCBCT) images acquired on the treatment day are used for generating the dose difference index. Each index is represented by different colors for underdose, acceptable, and overdose regions. A maximal intensity projection (MIP) algorithm is developed to compress all the information of an arbitrary 3D dose difference index into a 2D DD-MIP image. In such an algorithm, a distance transformation is generated based on the planning CT. Then, two new volumes representing the overdose and underdose regions of the dose difference index are encoded with the distance transformation map. The distance-encoded indices of each volume are normalized using the skin distance obtained on the planning CT. After that, two MIPs are generated based on the underdose and overdose volumes with green-to-blue and green-to-red lookup tables, respectively. Finally, the two MIPs are merged with an appropriate transparency level and rendered in planning CT images. Results: The spatially encoded DD-MIP was implemented in a dose-guided radiotherapy prototype and tested on 33 MVCBCT images from six patients. The user can easily establish the threshold for the overdose and underdose. A 3% difference between the treatment and planning dose was used as the threshold in the study; hence, the DD-MIP shows red or blue color for the dose difference >3% or {<=}3%, respectively. With such a method, the overdose and underdose regions can be visualized and distinguished without being overshadowed by superficial dose differences. Conclusions: A DD-MIP algorithm was developed that compresses information from 3D into a single or two orthogonal projections while hinting the user whether the dose difference is on the skin surface or deeper.

60 APPLIED LIFE SCIENCES↗

Effective action for noncommutative Bianchi I model

Quantum Mechanics, as a mini-superspace of Field Theory has been assumed to provide physically relevant information on quantum processes in Field Theory. In the case of Quantum Gravity this would imply using Cosmological models to investigate quantum processes at distances of the order of the Planck scale. However because of the Stone-von Neuman Theorem, it is well known that quantization of Cosmological models by the Wheeler-DeWitt procedure in the context of a Heisenberg-Weyl group with piecewise continuous parameters leads irremediably to a volume singularity. In order to avoid this information catastrophe it has been suggested recently the need to introduce in an effective theory of the quantization some form of reticulation in 3-space. On the other hand, since in the geometry of the General Relativistic formulation of Gravitation space can not be visualized as some underlying static manifold in which the physical system evolves, it would be interesting to investigate whether the effective reticulation which removes the singularity in such simple cosmologies as the Bianchi models has a dynamical origin manifested by a noncommutativity of the generators of the Heisenberg-Weyl algebra, as would be expected from an operational point of view at the Planck length scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Computational 3D histological phenotyping of whole zebrafish by X-ray histotomography

Organismal phenotypes frequently involve multiple organ systems. Histology is a powerful way to detect cellular and tissue phenotypes, but is largely descriptive and subjective. To determine how synchrotron-based X-ray micro-tomography (micro-CT) can yield 3-dimensional whole-organism images suitable for quantitative histological phenotyping, we scanned whole zebrafish, a small vertebrate model with diverse tissues, at ~1 micron voxel resolutions. Micro-CT optimized for cellular characterization (histotomography) allows brain nuclei to be computationally segmented and assigned to brain regions, and cell shapes and volumes to be computed for motor neurons and red blood cells. Striking individual phenotypic variation was apparent from color maps of computed densities of brain nuclei. Unlike histology, the histotomography also allows the study of 3-dimensional structures of millimeter scale that cross multiple tissue planes. We expect the computational and visual insights into 3D cell and tissue architecture provided by histotomography to be useful for reference atlases, hypothesis generation, comprehensive organismal screens, and diagnostics.

59 BASIC BIOLOGICAL SCIENCES↗

Visualizing red blood cell sickling and the effects of inhibition of sphingosine kinase 1 using soft X-ray tomography

ABSTRACT Sickle cell disease is a destructive genetic disorder characterized by the formation of fibrils of deoxygenated hemoglobin, leading to the red blood cell (RBC) morphology changes that underlie the clinical manifestations of this disease. Using cryogenic soft X-ray tomography (SXT), we characterized the morphology of sickled RBCs in terms of volume and the number of protrusions per cell. We were able to identify statistically a relationship between the number of protrusions and the volume of the cell, which is known to correlate to the severity of sickling. This structural polymorphism allows for the classification of the stages of the sickling process. Recent studies have shown that elevated sphingosine kinase 1 (Sphk1)-mediated sphingosine 1-phosphate production contributes to sickling. Here, we further demonstrate that compound 5C, an inhibitor of Sphk1, has anti-sickling properties. Additionally, the variation in cellular morphology upon treatment suggests that this drug acts to delay the sickling process. SXT is an effective tool that can be used to identify the morphology of the sickling process and assess the effectiveness of potential therapeutics.

59 BASIC BIOLOGICAL SCIENCES↗

Megavoltage Cone Beam Computed Tomography Dose and the Necessity of Reoptimization for Imaging Dose-Integrated Intensity-Modulated Radiotherapy for Prostate Cancer

Purpose: Megavoltage cone beam computed tomography (MV-CBCT) dose can be integrated with the patient's prescription. Here, we investigated the effects of imaging dose and the necessity for additional optimization when using intensity-modulated radiotherapy (IMRT) to treat prostate cancer. Methods and Materials: An arc beam mimicking MV-CBCT was generated using XiO (version 4.50; Elekta, Stockholm, Sweden). The monitor units (MU) for dose calculation were determined by conforming the calculated dose to the dose measured using an ionization chamber. IMRT treatment plans of 22 patients with prostate cancer were retrospectively analyzed. Arc beams of 3, 5, 8, and 15 MU were added to the IMRT plans, and the dose covering 95% of the planning target volume (PTV) was normalized to the prescribed dose with (reoptimization) or without optimization (compensation). Results: PTV homogeneity and conformality changed negligibly with MV-CBCT integration. For critical organs, an imaging dose-dependent increase was observed for the mean rectal/bladder dose (D{sub mean}), and reoptimization effectively suppressed the D{sub mean} elevations. The bladder generalized equivalent uniform dose (gEUD) increased with imaging dose, and reoptimization suppressed the gEUD elevation when 5- to 15-MU CBCT were added, although rectal gEUD changed negligibly with any imaging dose. Whereas the dose elevation from the simple addition of the imaging dose uniformly increased rectal and bladder dose, the rectal D{sub mean} increase of compensation plans was due mainly to low-dose volumes. In contrast, bladder high-dose volumes were increased by integrating the CBCT dose, and reoptimization reduced them when 5- to 15-MU CBCT were added. Conclusion: Reoptimization is clearly beneficial for reducing dose to critical organs, elevated by addition of high-MU CBCT, especially for the bladder. For low-MU CBCT aimed at bony structure visualization, compensation is sufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-FG-202-08: Assessment of Treatment Response Via Longitudinal Diffusion MRI On A MRI-Guided System: Initial Experience of Quantitative Analysis

Purpose: To report our initial experience of systematic monitoring treatment response using longitudinal diffusion MR images on a Co-60 MRI-guided radiotherapy system. Methods: Four patients, including 2 head-and-necks, 1 sarcoma and 1 GBM treated on a 0.35 Tesla MRI-guided treatment system, were analyzed. For each patient, 3D TrueFISP MRIs were acquired during CT simulation and before each treatment for treatment planning and patient setup purposes respectively. Additionally, 2D diffusion-weighted MR images (DWI) were acquired weekly throughout the treatment course. The gross target volume (GTV) and brainstem (as a reference structure) were delineated on weekly 3D TrueFISP MRIs to monitor anatomy changes, the contours were then transferred onto the corresponding DWI images after fusing with the weekly TrueFISP images. The patient-specific temporal and spatial variations during the entire treatment course, such as anatomic changes, target apparent diffusion coefficient (ADC) distribution were evaluated in a longitudinal pattern. Results: Routine MRI revealed progressive soft-tissue GTV volume changes (up to 53%) for the H&N cases during the treatment course of 5–7 weeks. Within the GTV, the mean ADC values varied from −44% (ADC decrease) to +26% (ADC increase) in a week. The gradual increase of ADC value was inversely associated with target volume variation for one H&N case. The maximal changes of mean ADC values within the brainstem were 5.3% for the H&N cases. For the large size sarcoma and GBM tumors, spatial heterogeneity and temporal variations were observed through longitudinal ADC analysis. Conclusion: In addition to the superior soft-tissue visualization, the 0.35T MR system on ViewRay showed the potential to quantitatively measure the ADC values for both tumor and normal tissues. For normal tissue that is minimally affected by radiation, its ADC values are reproducible. Tumor ADC values show temporal and spatial fluctuation that can be exploited for personalized adaptive therapy.

60 APPLIED LIFE SCIENCES↗

PBX-9501 High Explosive Infrared Thermography Test Report

High explosive safety requirements put in place by the Department of Defense necessitate that Los Alamos National Laboratory verify that high melting explosive-based plastic bonded explosive 9501 will not present a health or safety risk to personnel when exposed to various accident scenarios. The JT5R-14C test is being developed to validate this requirement in a scenario where PBX-9501 is exposed to a hydrocarbon fuel fire. Preliminary testing is required to establish benchmark data on the burning characteristics of PBX-9501. The PBX-9501 High Explosive Infrared Thermography test was designed to provide the benchmark burning characteristics of PBX-9501 in a simulated fuel fire environment using propane burners as a fuel source. The PBX-9501-HEIT was successfully completed using a 20.32 cm tall cylindrical sample of PBX-9501 with a radius of 10.16 cm, a volume of 6,589.63 cm 3 , a density of 1.83 g/cm 3 , and a mass of 1.2 kg. The PBX-9501-HEIT test was captured and recorded video sequence using a Telops Inc., Multispectral Infrared camera. The infrared sequence was reviewed to identify key events throughout the test and serves as a visual tool to cross reference against future testing to aid in the identification of PBX-9501 high explosive ignition and deflagration characteristics. The data obtained in the thermographic sequence confirmed that the temperatures emitted by the PBX-9501 were higher than the temperatures of the propane burner ignition source. The propane burner flames had a temperature range of 700-850 °C. The cylindrical sample of PBX-9501 burned at an average temperature of 1000-1200 °C on the surface with off-gassing temperatures averaging 1100-1250 °C. The heat map of the PBX-9501 obtained through the test was between 250-550 °C higher than the propane gas temperatures. The temperature differential between the PBX-9501 and the propane flame allowed for the identification of key burning features.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗