Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable density flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Four-Dimensional Oceanic and Atmosperic Data Assimilation with Tropical Rainfall Measuring Mission Data

An oceanic data assimilation system which allows to utilize the forthcoming Tropical Rainfall Measuring Mission (TRMM) data has been developed and applied to the Pacific Ocean to produce the velocity field. The assimilated data will be indispensable to examine the effects of rainfall and its variability on the structure and circulation of the tropical oceans and to assess the impact of global warming due to the increase of carbon dioxide on the ocean circulation system and the marine pollution caused by oil spill and ocean damping of radionuclide. The data will also provide the verification for the oceanic and ocean-atmosphere coupled General Circulation Models (GCM's). The system consists of oceanic GCM, analysis scheme and data. In the system the flow field has been determined to be physically consistent with the observed density field and the sea surface winds derived from the Special Sensor Microwave Imagery (SSM/I) data which drive the ocean current. The time integration has been performed for five years until the flow field near the surface attained the steady state starting from the rest ocean with observed temperature and salinity fields, and the SSM/I surface wind velocity. The resultant flow field showed high producibility of the system. Especially the flow near the ocean surface agreed well with available observed data. The system, for the first time, succeeded to produce the eastward subtropical current which has been discovered in the joint investigation on Kuroshio current (CSK) in the 1960s. To verify the quality of the flow field a trajectory analysis has been carried out and compared with the Algos buoy data. BRIEF DESCRIPTION OF THE DATA ASSIMILATION SYSTEM ## Oceanic GCM and analysis scheme--The basic equations are much the same as used for the GCM's, except for the Newtonian damping terms introduced into the prediction equations for the potential temperature and salinity to maintain these fields as observed. The C grid of 2'lat. by 2'long. in horizontal and the 11 vertical levels are applied to the entire Pacific Ocean. At the east and west ocean boundaries the periodic boundary conditions are applied creating fictitious ocean there. The SMAC Method is used to increase the accuracy of mass conservation. * Data--The JODC temperature and salinity data obtained from 1906 to 1988 are used in the system between Long.100'E. and 60'W. The surface wind data are derived from the SSM/I data by Dr-R. Atlas of NASA/GSFC. The data set contains every 6 hours data from July 1987 to June 1989 on the grid of 2'lat. by 2.5'long. The averaged for the whole period and then interpolated into the 2'lat. by 2'long. grid data are used to force the system. The sea bottom topography data was based on the General Bathymetric Chart of the Ocean (GEBCO) supplied by the Canadian Hydrographic Service under contract with the International Hydrographic Organization and International Oceanographic Commission of UNESCO.

Takano, Kenji↗

Surface Time-Variable Gravity Signals and Possible Sources Including Core Mass Flow

Over two decades of geodetic satellite-laser-ranging (SLR) data show that the variation of the Earth's oblateness parameter J2 has a clear seasonal signal of amplitude of about 3e-10 and a secular decrease of about -2.8e-11/year, superimposed on some interesting interannual fluctuations. Physically, any change in mass distribution or/inside the Earth will be reflected in the time-variable gravity signal obtained outside the Earth, according to Newton s gravitational law. Therefore, such signal contains contributions from all geophysical sources that redistribute mass, on all temporal and spatial scales, including those from the core. Besides Earth rotation and geomagnetic field variations, the time-variable gravity also contains information linking Earth surface observations with internal core dynamical processes. The time scales of the gravity signal are critical in helping differentiate different contributions. The atmosphere and hydrosphere are responsible for the seasonal and much of the interannual and intraseasoanl fluctuations, while the secular trend is due mainly to the post-glacial rebound but possibly core mass flow. To estimate the latter effect, we use our MoSST (Modular, Scalable, Self-consistent, Three-dimensional) core dynamics model to forward simulate the core flow, and density variation due to the core convection. Our results suggest that, when upward continued to the surface, the J2 component of the core mass redistribution can reach an overall amplitude of e-11/year, approaching the SLR detectability and significant in geophysical terms. We also find a general westward drift of the mass flow, with a speed comparable to that of the geomagnetic westward drift.

Chao, Benjamin F.↗

Quasioptical design of integrated Doppler backscattering and correlation electron cyclotron emission systems on the DIII-D tokamak

The quasioptical design of a new integrated Doppler backscattering (DBS) and correlation electron cyclotron emission (CECE) system is presented. The design provides for simultaneous measurements of intermediate wavenumber density and long wavelength electron temperature turbulence behavior. The Doppler backscattering technique is sensitive to plasma turbulence flow and has been utilized to determine radial electric field, geodesic acoustic modes, zonal flows, and intermediate scale (k{approx}1-6 cm{sup -1}) density turbulence. The correlation ECE system measures a second turbulent field, electron temperature fluctuations, and is sensitive to long poloidal wavelength (k{<=}1.8 cm{sup -1}). The integrated system utilizes a newly installed in-vessel focusing mirror that produces a beam waist diameter of 3.5-5 cm in the plasma depending on the frequency. A single antenna (i.e., monostatic operation) is used for both launch and receive. The DBS wavenumber is selected via an adjustable launch angle and variable probing frequency. Due to the unique system design both positive and negative wavenumbers can be obtained, with a range of low to intermediate wavenumbers possible (approximately -3 to 10 cm{sup -1}). A unique feature of the design is the ability to place the DBS and CECE measurements at the same radial and poloidal locations allowing for cross correlation studies (e.g., measurement of nT cross-phase).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Aerodynamic Characteristics of Airfoils as Affected by Surface Roughness

The effect on airfoil characteristics of surface roughness of varying degrees and types at different locations on an airfoil was investigated at high values of the Reynolds number in a variable density wind tunnel. Tests were made on a number of National Advisory Committee for Aeronautics (NACA) 0012 airfoil models on which the nature of the surface was varied from a rough to a very smooth finish. The effect on the airfoil characteristics of varying the location of a rough area in the region of the leading edge was also investigated. Airfoils with surfaces simulating lap joints were also tested. Measurable adverse effects were found to be caused by small irregularities in airfoil surfaces which might ordinarily be overlooked. The flow is sensitive to small irregularities of approximately 0.0002c in depth near the leading edge. The tests made on the surfaces simulating lap joints indicated that such surfaces cause small adverse effects. Additional data from earlier tests of another symmetrical airfoil are also included to indicate the variation of the maximum lift coefficient with the Reynolds number for an airfoil with a polished surface and with a very rough one.

HOCKER RAY W↗

The coupling between flame surface dynamics and species mass conservation in premixed turbulent combustion

Current flamelot models based on a description of the flame surface dynamics require the closure of two inter-related equations: a transport equation for the mean reaction progress variable, (tilde)c, and a transport equation for the flame surface density, Sigma. The coupling between these two equations is investigated using direct numerical simulations (DNS) with emphasis on the correlation between the turbulent fluxes of (tilde)c, bar(pu''c''), and Sigma, (u'')(sub S)Sigma. Two different DNS databases are used in the present work: a database developed at CTR by A. Trouve and a database developed by C. J. Rutland using a different code. Both databases correspond to statistically one-dimensional premixed flames in isotropic turbulent flow. The run parameters, however, are significantly different, and the two databases correspond to different combustion regimes. It is found that in all simulated flames, the correlation between bar(pu''c'') and (u'')(sub S)Sigma is always strong. The sign, however, of the turbulent flux of (tilde)c or Sigma with respect to the mean gradients, delta(tilde)c/delta(x) or delta(Sigma)/delta(x), is case-dependent. The CTR database is found to exhibit gradient turbulent transport of (tilde)c and Sigma, whereas the Rutland DNS features counter-gradient diffusion. The two databases are analyzed and compared using various tools (a local analysis of the flow field near the flame, a classical analysis of the conservation equation for (tilde)(u''c''), and a thin flame theoretical analysis). A mechanism is then proposed to explain the discrepancies between the two databases and a preliminary simple criterion is derived to predict the occurrence of gradient/counter-gradient turbulent diffusion.

Trouve, A.↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chemical redox of lithium-ion solid electroactive material in a packed bed flow reactor

Chemical redox reactions between solid electroactive materials and dissolved electroactive compounds are a necessary component of emerging technologies relevant to renewable energy including high energy density flow batteries and battery material recycling. In this work, an initial investigation of heterogeneous chemical redox for a packed bed reactor configuration between solid electroactive material and dissolved redox shuttles will be described. Experimental conditions including the height of the packed bed, the redox shuttle solution concentration, solution flow rate, and operating temperature were varied and their impact on the molar conversion of the solid electroactive material in the packed bed was quantified using electroanalytical techniques on the reactor effluent. The progression of the reaction and its dependence on the different variables explored will be discussed in the context of the limiting processes for porous packed aggregates of the solid electroactive material undergoing chemical oxidation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gravitational collapse of a turbulent vortex with application to star formation

The gravitational collapse of a rotating cloud or vortex is analyzed by expanding the dependent variables in the equations of motion in two-dimensional Taylor series in the space variables. It is shown that the gravitational and rotational terms in the equations are of first order in the space variables, the pressure-gradient terms are of second order, and the turbulent-viscosity term is of third order. The presence of turbulent viscosity ensures that the initial rotation is solid-body-like near the origin. The effect of pressure on the collapse process is found to depend on the shape of the initial density disturbance at the origin. Dimensionless collapse times, as well as the evolution of density and velocity, are calculated by solving numerically the system of nonlinear ordinary differential equations resulting from the series expansions. The axial flow is always inward and allows collapse to occur (axially) even when the rotation is large. An approximate solution of the governing partial differential equations is also given in order to study the spatial distributions of the density and velocity.

Deissler, R. G.↗

Evidence for temporal variations in polar plumes

The variability of the O VI and Mg X emissions from four plumes is studied in order to place empirical constraints on possible plasma heating processes and acceleration mechanisms for mass flows in polar plumes. The observations comprise a 40 min seqeunce of spectroheliograms acquired with a temporal resolution of approximately 2 min. It is found that the Mg X emission from each plume has a strong 'dc' component and that any variations occurred at approximately the 10 percent (of the mean) level or less. This means that temporal variations in the density and/or temperature were 5 percent or less. Some statistically significant variations in the measured Mg X signals are seen. It is noted that two of the plumes decreased in brightness by approximately 10 percent during the 40 min period of the observations. Besides this, two plumes exhibited short-term (few minute) variations that are seen as statistically significant at a confidence level of more than 90 percent. The latter variations (if real) are thought to be due to small (approximately 20,000 K) fluctuations in temperature caused by fluctuations in the local plasma heating rate.

Withbroe, G. L.↗

Frost Growth and Densification in Laminar Flow Over Flat Surfaces

One-dimensional frost growth and densification in laminar flow over flat surfaces has been theoretically investigated. Improved representations of frost density and effective thermal conductivity applicable to a wide range of frost circumstances have been incorporated. The validity of the proposed model considering heat and mass diffusion in the frost layer is tested by a comparison of the predictions with data from various investigators for frost parameters including frost thickness, frost surface temperature, frost density and heat flux. The test conditions cover a range of wall temperature, air humidity ratio, air velocity, and air temperature, and the effect of these variables on the frost parameters has been exemplified. Satisfactory agreement is achieved between the model predictions and the various test data considered. The prevailing uncertainties concerning the role air velocity and air temperature on frost development have been elucidated. It is concluded that that for flat surfaces increases in air velocity have no appreciable effect on frost thickness but contribute to significant frost densification, while increase in air temperatures results in a slight increase the frost thickness and appreciable frost densification.

Kandula, Max↗

Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Upgrade Activities

Over the past year the Nuclear Thermal Rocket Element Environmental Simulator (NTREES) has been undergoing a significant upgrade beyond its initial configuration. The NTREES facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot mimic the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The first phase of the upgrade activities which was completed in 2012 in part consisted of an extensive modification to the hydrogen system to permit computer controlled operations outside the building through the use of pneumatically operated variable position valves. This setup also allows the hydrogen flow rate to be increased to over 200 g/sec and reduced the operation complexity of the system. The second stage of modifications to NTREES which has just been completed expands the capabilities of the facility significantly. In particular, the previous 50 kW induction power supply has been replaced with a 1.2 MW unit which should allow more prototypical fuel element temperatures to be reached. The water cooling system was also upgraded to so as to be capable of removing 100% of the heat generated during. This new setup required that the NTREES vessel be raised onto a platform along with most of its associated gas and vent lines. In this arrangement, the induction heater and water systems are now located underneath the platform. In this new configuration, the 1.2 MW NTREES induction heater will be capable of testing fuel elements and fuel materials in flowing hydrogen at pressures up to 1000 psi at temperatures up to and beyond 3000 K and at near-prototypic reactor channel power densities. NTREES is also capable of testing potential fuel elements with a variety of propellants, including hydrogen with additives to inhibit corrosion of certain potential NTR fuel forms. Additional diagnostic upgrades included in the present NTREES set up include the addition of a gamma ray spectrometer located near the vent filter to detect uranium fuel particles exiting the fuel element in the propellant exhaust stream to provide additional information any material loss occurring during testing. Other aspects of the upgrade included reworking NTREES to reduce the operational complexity of the system despite the increased complexity of the induction heating system. To this end, many of the controls were consolidated on fewer panels. As part of this upgrade activity, the Safety Assessment (SA) and the Standard Operating Procedures (SOPs) for NTREES were extensively rewritten. The new 1.2 MW induction heater consists of three physical units consisting of a transformer, rectifier, and inverter. This multiunit arrangement facilitated increasing the flexibility of the induction heater by more easily allowing variable frequency operation. Frequency ranges between 20 and 60 kHz can be accommodated in the new induction heater allowing more representative power distributions to be generated within the test elements.

Emrich, William J., Jr.↗

Low-energy plasma observations at synchronous orbit

The University of California at San Diego Auroral Particles Experiment on the ATS 6 satellite in synchronous orbit has detected a low-energy plasma population which is separate and distinct from both the ring current and the plasma sheet populations. The density and temperature of this low-energy population are highly variable, with temperatures in the range kT = 1-30 eV and densities ranging from less than 1 per cu cm to more than 10 per cu cm. The occurrence of a dense low-energy plasma is most likely in the afternoon and dusk local time sectors, whereas n greater than 1 per cu cm is seen in the local night sector only during magnetically quiet periods. These observations suggest that this plasma is the outer zone of the plasmasphere. During magnetically active periods this low-energy plasma is often observed flowing sunward. In the dusk sector, strong sunward plasma flow is often observed for 1-2 hours prior to the onset of a substorm-associated particle injection.

Lennartsson, W.↗

Buoyant thermocapillary flow with nonuniform supra-heating. I - Liquid-phase behavior. II - Two-phase behavior

The present computational study of transient heat transfer and fluid flow in a circular pool of n-decane which is undergoing central radiative heating from above gives attention to the volumetric absorption of the radiation incident on the pool surface. The first part of this study notes that buoyancy influences the number and recirculation rates of the subsurface vortices by stabilizing hot subsurface fluid above the colder core fluid; this affects the liquid surface temperature profile and in turn governs the velocity profile that is due to thermocapillarity. In the second part, the effects of gas-liquid phase coupling, variable density and thermophysical properties, and vaporization are considered.

Schiller, David N.↗

Evaluation of performance indicators applied to a material recovery facility fed by mixed packaging waste

Highlights: • Material Flows assessment of a Material Recovery Facility has been realized. • Performance Indicators for a generic MRF have been proposed. • A Dashboard has been utilized to measure the facility performance. • Experimental values of incoming waste and output products composition are reported. - Abstract: Most of the integrated systems for municipal solid waste management aim to increase the recycling of secondary materials by means of physical processes including sorting, shredding and reprocessing. Several restrictions prevent from reaching a very high material recycling efficiency: the variability of the composition of new-marketed materials used for packaging production and its shape and complexity are critical issues. The packaging goods are in fact made of different materials (aluminium, polymers, paper, etc.), possibly assembled, having different shape (flat, cylindrical, one-dimensional, etc.), density, colours, optical properties and so on. These aspects limit the effectiveness and efficiency of the sorting and reprocessing plants. The scope of this study was to evaluate the performance of a large scale Material Recovery Facility (MRF) by utilizing data collected during a long period of monitoring. The database resulted from the measured data has been organized in four sections: (1) data related to the amount and type of inlet waste; (2) amount and composition of output products and waste; (3) operating data (such as worked hours for shift, planned and unscheduled maintenance time, setting parameters of the equipment, and energy consumption for shift); (4) economic data (value of each product, disposal price for the produced waste, penalty for non-compliance of products and waste, etc.). A part of this database has been utilized to build an executive dashboard composed by a set of performance indicators suitable to measure the effectiveness and the efficiency of the MRF operations. The dashboard revealed itself as a powerful tool to support managers and engineers in their decisions in respect to the market demand or compliance regulation variation as well as in the designing of the lay-out improvements. The results indicated that the 40% of the input waste was recovered as valuable products and that a large part of these (88%) complied with the standards of the recycling companies. The evaluation of the indicators led to the decision to modify the layout to improve the interception of some polymers for which the performance indicators were poor. In particular, two additional optical sorters have to be inserted to increase the yield indicator and to the overall performance of the facility. Definitely, the results of the work allowed to: increase the yield and purity of products’ flows; ensure the compliance of waste flows; increase the workability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Carbothermic Synthesis of ~820- m UN Kernels. Investigation of Process Variables

This report details the continued investigation of process variables involved in converting sol-gel-derived, urainia-carbon microspheres to ~820-μm-dia. UN fuel kernels in flow-through, vertical refractory-metal crucibles at temperatures up to 2123 K. Experiments included calcining of air-dried UO 3 -H 2 O-C microspheres in Ar and H 2 -containing gases, conversion of the resulting UO 2 -C kernels to dense UO 2 :2UC in the same gases and vacuum, and its conversion in N 2 to in UC 1-x N x . The thermodynamics of the relevant reactions were applied extensively to interpret and control the process variables. Producing the precursor UO 2 :2UC kernel of ~96% theoretical density was required, but its subsequent conversion to UC 1-x N x at 2123 K was not accompanied by sintering and resulted in ~83-86% of theoretical density. Decreasing the UC 1-x N x kernel carbide component via HCN evolution was shown to be quantitatively consistent with present and past experiments and the only useful application of H2 in the entire process.

36 MATERIALS SCIENCE↗

Heat Transmission in the Boundary Layer

In the present paper which deals with the heat transfer between the gas and the wall for large temperature drops and large velocities use is made of the method of Dorodnitsyn of the introduction of a new independent variable, with this difference, however, that the relation between the temperature field (that is, density) and the velocity field in the general case considered is not assumed given but is determined from the solution of the problem. The effect of the compressibility arising from the heat transfer is thus taken into account (at the same time as the effect of the compressibility at the large velocities). A method is given for determining the coefficients of heat transfer and the friction coefficients required in many technical problems for a curved wall in a gas flow at large Mach numbers and temperature drops. The method proposed is applicable both for Prandtl number P = 1 and for P not equal to 1.

Kalikhman, L. E.↗

Terminator Double Layer Explorer (TerDLE): Examining the Near-Moon Lunar Wake

As the solar wind flows by the Moon, an antisunward-directed low-density wake forms as the plasma expands to fill in the trailing void in the plasma flow. Analytical modeling and modern plasma simulations suggest that plasma quasi-neutrality could possibly be broken close to the terminator obstruction as solar wind electrons expand into the wake ahead of the ions, leading to the formation of a standing (time-stationary) double layer. The objective of the Terminator Double Layer Explorer is to extend the fundamental understanding of the plasma expansion into the trailing near-vacuum wake region by (1) identifying any plasma expansion density anomalies at low altitudes near the terminator wake initiation region, (2) assessing the highly variable solar wind's effect on the low-altitude wake region, and (3) determining if plasma neutrality is maintained or lost during passages through the low-altitude expansion region. The mission concept uses a propulsion-driven CubeSat with ion spectrometer and plasma wave system in elliptical orbit about the Moon with periselene near the terminator. Over the course of the mission, the periselene decreases, placing the CubeSat ever closer to the terminator wake initiation location and the possible nonneutral region.

lunar science↗

ISEE observations of the plasma sheet boundary, plasma sheet, and neutral sheet. I - Electric field, magnetic field, plasma, and ion composition

The first simultaneous study of dc and ac electric and magnetic fields, E x B velocity, plasma flows, ratio of plasma to magnetic field pressure, total energy density, energetic particles, and ion composition from the ISEE satellites and ground and interplanetary magnetic fields has been made to determine (1) the relationship of the previously observed electric fields at the plasma sheet boundary and at the neutral sheet to plasma parameters, and (2) whether the phenomena occurring during quiet and active times were consistent with the formation of a near-earth neutral line during substorms or with the boundary layer model. Five observations made during the study of two substorms were seen to be in agreement with the neutral-line model. The observations are consistent with the satellite being located at varying distances from the neutral line and diffusion region where reconnection and plasma acceleration were occurring. Although the z component (into or out of the ecliptic plane) of E x B convection was generally toward the neutral sheet, there were examples when it was consistent with the inferred motion of the plasma sheet past the satellite. A synthesis of previous reports on large electric fields at the plasma sheet boundary and variable fields at the neutral sheet including the associated plasma flows is also described.

Cattell, C. A.↗