Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

An interchangeable-cathode vacuum arc plasma source

A simplified vacuum arc design [based on metal vapor vacuum arc (MeVVA) concepts] is employed as a plasma source for a study of a {sup 7}Be non-neutral plasma. The design includes a mechanism for interchanging the cathode source. Testing of the plasma source showed that it is capable of producing on the order of 10{sup 12} charges at confinable energies using a boron-carbide disk as the cathode target. The design is simplified from typical designs for lower energy and lower density applications by using only the trigger spark rather than the full vacuum arc in high current ion beam designs. The interchangeability of the cathode design gives the source the ability to replace only the source sample, simplifying use of radioactive materials in the plasma source. The sample can also be replaced with a completely different conductive material. The design can be easily modified for use in other plasma confinement or full MeVVA applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacuum magnetic field mapping experiments for validated determination of the helical field coil location in stellarators

Understanding the behavior of plasmas in magnetic confinement fusion devices typically requires accurate knowledge of the magnetic field structure. In stellarator-type confinement devices, the helical magnetic field is produced by currents in external coils and may be traced experimentally in the absence of plasma through the experimental technique of vacuum magnetic field mapping. Field mapping experiments, such as these, were performed on the recently constructed compact toroidal hybrid to verify the range of accessible magnetic configurations, compare the actual magnetic configuration with the design configuration, and identify any vacuum field errors that lead to perturbations of the vacuum magnetic flux surfaces. Furthermore, through the use of a new coil optimization routine, modifications are made to the simulation coil model such that better agreement exists between the experimental and simulation results. An outline of the optimization procedure is discussed in conjunction with the results of one such optimization process performed on the helical field coil.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum electrodynamics vacuum polarization modification of photon acceleration in plasma

The modification of photon frequency shifting based on taking into account the nonlinear quantum electrodynamics vacuum properties in plasma is studied. Motion equations of a laser field propagating in a plasma are derived from the Heisenberg-Euler Lagrangian density. It is found that besides the classical density perturbation of the plasma electrons, the energy density perturbation of the laser field will induce the frequency shifting via the ponderomotive force of the laser field on the vacuum. In addition it is shown that the electron density will be suppressed, which is attributed to a screening effect on the plasma electrons via the quantum vacuum polarization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Some scenarios with non-homogeneous Higgs vacuum

The standard Higgs mechanism employed in the Standard Model (SM) for electroweak symmetry breaking, relies on a homogenous Higgs vacuum expectation value (v.e.v.), i.e. a vacuum that does not depend on the position or the time coordinates. However, other non-homogeneous structures could also be considered, either at long or short distances. For instance, spatial variations of the Higgs v.e.v. on cosmological scales, would induce variations of the fundamental constants, and are severely constrained. Other possibilities, such as a discrete microscopic structure of the Higgs vacuum, or a confined Higgs mechanism associated with a strongly interacting Higgs sector, could be tested and give some light on the electroweak-scale contributions to the cosmological constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Successful Cleaning and Study of Contamination of Si(001) in Ultrahigh Vacuum

This paper presents the very first surface physics experiment performed in ultrahigh vacuum (UHV) in Romania, using a new molecular beam epitaxy (MBE) installation. Cleaning of a Si(001) wafer was achieved by using a very simple technique: sequences of annealing at 900-1000 deg. C in ultrahigh vacuum: low 10{sup -8} mbar, with a base pressure of 1.5x10{sup -10} mbar. The preparation procedure is quite reproducible and allows repeated cleaning of the Si(001) after contamination in ultrahigh vacuum. The Si(001) single crystal surface is characterized by low energy electron diffraction (LEED), reflection high energy electron diffraction (RHEED), and Auger electron spectroscopy (AES). The latter technique is utilized in order to investigate the sample contamination by the residual gas in the UHV chamber, as determined by a residual gas analyzer (RGA). Unambiguous assignment of oxidized and unoxidized silicon is provided; also, an important feature is that the LVV Auger peak at 90-92 eV cannot be solely attributed to clean Si (i.e. Si surrounded only by Si), but also to silicon atoms bounded with carbon. Even with a sum of partial pressures of oxygen and carbon containing molecules in the range of 5x10{sup -10} mbar, the sample is contaminated very quickly, having a (1/e) lifetime of about 76 minutes.

36 MATERIALS SCIENCE↗

Generation of high charge state metal ion beams by electron cyclotron resonance heating of vacuum arc plasma in cusp trap

A method for generating high charge state heavy metal ion beams based on high power microwave heating of vacuum arc plasma confined in a magnetic trap under electron cyclotron resonance conditions has been developed. A feature of the work described here is the use of a cusp magnetic field with inherent ''minimum-B'' structure as the confinement geometry, as opposed to a simple mirror device as we have reported on previously. The cusp configuration has been successfully used for microwave heating of gas discharge plasma and extraction from the plasma of highly charged, high current, gaseous ion beams. Now we use the trap for heavy metal ion beam generation. Two different approaches were used for injecting the vacuum arc metal plasma into the trap - axial injection from a miniature arc source located on-axis near the microwave window, and radial injection from sources mounted radially at the midplane of the trap. Here, we describe preliminary results of heating vacuum arc plasma in a cusp magnetic trap by pulsed (400 {mu}s) high power (up to 100 kW) microwave radiation at 37.5 GHz for the generation of highly charged heavy metal ion beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunability of the terahertz space-charge modulation in a vacuum microdiode

Under certain conditions, space-charge limited emission in vacuum microdiodes manifests as clearly defined bunches of charge with a regular size and interval. The frequency corresponding to this interval is in the terahertz range. In this computational study, it is demonstrated that, for a range of parameters, conducive to generating THz frequency oscillations, the frequency is dependant only on the cold cathode electric field and on the emitter area. For a planar micro-diode of given dimension, the modulation frequency can be easily tuned simply by varying the applied potential. Simulations of the microdiode are done for 84 different combinations of emitter area, applied voltage, and gap spacing, using a molecular dynamics based code with exact Coulomb interaction between all electrons in the vacuum gap, which is of the order 100. It is found, for a fixed emitter area, that the frequency of the pulse train is solely dependant on the vacuum electric field in the diode, described by a simple power law. It is also found that, for a fixed value of the electric field, the frequency increases with diminishing size of the emitting spot on the cathode. Some observations are made on the spectral quality, and how it is affected by the gap spacing in the diode and the initial velocity of the electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Hollow cathode lamp with integral, high optical efficiency isolation valve: A modular vacuum ultraviolet source

The design and operating conditions of a hollow cathode discharge lamp for the generation of vacuum ultraviolet radiation, suitable for ultrahigh vacuum (UHV) application, are described in detail. The design is easily constructed, and modular, allowing it to be adapted to different experimental requirements. A thin isolation valve is built into one of the differential pumping stages, isolating the discharge section from the UHV section, both for vacuum safety and to allow lamp maintenance without venting the UHV chamber. The lamp has been used both for ultraviolet photoelectron spectroscopy of surfaces and as a “soft” photoionization source for gas-phase mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: In situ measurement of vacuum window birefringence by atomic spectroscopy

We present an in situ method to measure the birefringence of a single vacuum window by means of microwave spectroscopy on an ensemble of cold atoms. Stress-induced birefringence can cause an ellipticity in the polarization of an initially linearly polarized laser beam. The amount of ellipticity can be reconstructed by measuring the differential vector light shift of an atomic hyperfine transition. Measuring the ellipticity as a function of the linear polarization angle allows us to infer the amount of birefringence Δn at the level of 10{sup −8} and identify the orientation of the optical axes. The key benefit of this method is the ability to separately characterize each vacuum window, allowing the birefringence to be precisely compensated in existing vacuum apparatuses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient heat transfer in helium II due to a sudden vacuum break

To ensure future cryogenic devices meet safety and operational specifications, significant value is gained from a developed understanding of the transient heat fluxes that result from failure of an insulating vacuum jacket around a helium II (He II)-cooled device. A novel, one-dimensional experiment is successfully performed examining the phenomena immediately following a vacuum rupture onto a cryosurface. In the experiment, a fast-opening (∼10 ms) valve isolates a rigid container of ultra high purity nitrogen (N{sub 2}) gas kept at room temperature and adjustable pressure from a vertically oriented, highly evacuated (∼10{sup −3} Pa) tube roughly 1 m in length. The bottom of the evacuated tube is sealed via a 2.54 mm thick copper disk, whose bottom surface is in intimate contact with an open column of He II (∼1.8 K). The evacuated tube, disk, and He II column share a diameter of 24 mm. Opening the valve results in a vacuum rupture. N{sub 2} gas is immediately drawn into the evacuated space and cryopumped onto the disk as a growing layer of solid cryodeposit. Various coupled transient heat transfer processes proceed as the internal energy of the warm gas is transferred through the growing layer of solid N{sub 2}, through the copper disk, and into the He II column. This work examines the qualitative nature of these transient phenomena and the magnitude of the heat fluxes present through each of the series of thermal resistances.

42 ENGINEERING↗

Modeling the pressure increase in liquid helium cryostats after failure of the insulating vacuum

The pressure relief system of liquid helium cryostats requires a careful design, due to helium's low enthalpy of vaporization and due to the low operating temperature. Hazard analyses often involve the failure of the insulating vacuum in the worst-case scenario. The venting of the insulating vacuum and the implications for the pressure increase in the helium vessel, however, have not yet been fully analyzed. Therefore, the dimensioning of safety devices often requires experience and reference to very few experimental data. In order to provide a better foundation for the design of cryogenic pressure relief systems, this paper presents an analytic approach for the strongly dynamic process induced by the loss of insulating vacuum. The model is based on theoretical considerations and on differential equation modeling. It contains only few simplifying assumptions, which will be further investigated in future experiments. The numerical solutions of example calculations are presented with regard to the heat flux into the helium vessel, the helium pressure increase and the helium flow rate through the pressure relief device. Implications concerning two-phase flow and the influence of kinetic energy are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of fast heating electron beam annealing setup for ultra high vacuum chamber

We report the design and development of a simple, electrically low powered and fast heating versatile electron beam annealing setup (up to 1000 °C) working with ultra high vacuum (UHV) chamber for annealing thin films and multilayer structures. The important features of the system are constant temperature control in UHV conditions for the temperature range from room temperature to 1000 ºC with sufficient power of 330 W, at constant vacuum during annealing treatment. It takes approximately 6 min to reach 1000 °C from room temperature (∼10{sup −6} mbar) and 45 min to cool down without any extra cooling. The annealing setup consists of a UHV chamber, sample holder, heating arrangement mounted on suitable UHV electrical feed-through and electronic control and feedback systems to control the temperature within ±1 ºC of set value. The outside of the vacuum chamber is cooled by cold air of 20 °C of air conditioning machine used for the laboratory, so that chamber temperature does not go beyond 50 °C when target temperature is maximum. The probability of surface oxidation or surface contamination during annealing is examined by means of x-ray photoelectron spectroscopy of virgin Cu sample annealed at 1000 °C.

36 MATERIALS SCIENCE↗

First-principles study of carbon impurities in CuInSe{sub 2} and CuGaSe{sub 2}, present in non-vacuum synthesis methods

A first-principles study of the structural and electronic properties of carbon impurities in CuInSe{sub 2} and CuGaSe{sub 2} is presented. Carbon is present in organic molecules in the precursor solutions used in non-vacuum growth methods for CuInSe{sub 2} and CuGaSe{sub 2} based photovoltaic cells. These growth methods make more efficient use of material, time, and energy than traditional vacuum methods. The formation energies of several carbon impurities are calculated using the hybrid HSE06 functional. C{sub Cu} acts as a shallow donor, C{sub In} and interstitial C yield deep donor levels in CuInSe{sub 2}, while in CuGaSe{sub 2} C{sub Ga} and interstitial C act as deep amphoteric defects. So, these defects reduce the majority carrier (hole) concentration in p-type CuInSe{sub 2} and CuGaSe{sub 2} by compensating the acceptor levels. The deep defects are likely to act as recombination centers for the photogenerated charge carriers and are thus detrimental for the performance of the photovoltaic cells. On the other hand, the formation energies of the carbon impurities are high, even under C-rich growth conditions. Thus, few C impurities will form in CuInSe{sub 2} and CuGaSe{sub 2} in thermodynamic equilibrium. However, the deposition of the precursor solution in non-vacuum growth methods presents conditions far from thermodynamic equilibrium. In this case, our calculations show that C impurities formed in non-equilibrium tend to segregate from CuInSe{sub 2} and CuGaSe{sub 2} by approaching thermodynamic equilibrium, e.g., via thorough annealing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of nonthermal electrons on plasma expansion into vacuum

The expansion of semi-infinite plasma into vacuum is analyzed with a hydrodynamic model for cold ions assuming electrons modelled by a kappa-type distribution. Similarly to Mora study of a plasma expansion into vacuum [P. Mora, Phys. Rev. Lett. 90, 185002 (2003)], we formulated empirical expressions for the electric field strength, velocity, and position of the ion front in one-dimensional nonrelativistic, collisionless isothermally expanding plasma. Analytic expressions for the maximum ion energy and the spectrum of the accelerated ions in the plasma were derived and discussed to highlight the electron nonthermal effects on enhancing the ion acceleration in plasma expansion into vacuum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An integrated wire harp and readout electronics inside vacuum

A wire harp is a well known instrument used in ion beam profile measurement and beam diagnostics. Till date, for beam instrumentation, the harp is placed inside the vacuum chamber or beam line in direct exposure to the beam profile to be measured, whereas the related readout electronics is placed outside somewhere at a convenient place. Here, a harp has been developed along with the readout electronics as an integrated part of it and both were placed inside the beam line vacuum (order of 10{sup −7} Torr) to make the system much simpler, easy to operate, and measure small beam current more accurately. The entire signal conversion and processing is done inside the vacuum unlike other systems; hence, the electronics is kept inside. This results in a lesser number (only 4 pin) of electrical connections (feedthrough) including power which otherwise would have required 32 feedthrough pins only for signal readout for a 13 × 13 (X × Y) channel harp. This paper describes a completely new approach to the design of a conventional beam harp widely used for beam instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transparency of graphene for low-energy electrons measured in a vacuum-triode setup

Graphene, being an atomically thin conducting sheet, is a candidate material for gate electrodes in vacuum electronic devices, as it may be traversed by low-energy electrons. The transparency of graphene to electrons with energies between 2 and 40 eV has been measured by using an optimized vacuum-triode setup. The measured graphene transparency equals ∼60% in most of this energy range. Based on these results, nano-patterned sheets of graphene or of related two-dimensional materials are proposed as gate electrodes for ambipolar vacuum devices.

36 MATERIALS SCIENCE↗

Performance evaluation and parametric optimum design of a vacuum thermionic solar cell

A model of the vacuum thermionic solar cell (VTSC) consisting of a solar concentrator, an emitter, and a collector is proposed, in which the various heat losses including the far- and near-field thermal radiation are taken into account. Formula for the overall efficiency of the system is analytically derived. For given values of the ratio of the front surface area of the absorber to that of the emitter and the vacuum gap between the emitter and the collector, the operating temperatures of the emitter and collector are determined by solving the energy balance equations. The maximum efficiency of the VTSC are calculated for given values of the work functions of the emitter and collector materials, and some key parameters such as the net current density of the VTSC, operating temperatures of the emitter and collector, vacuum gap between the emitter and the collector, and area ratio of the absorber to the emitter are optimally determined. Furthermore, the effects of the work functions and the concentration ratio of the solar irradiation on the performance of the VTSC are discussed and several parametric selection criteria are obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of nanoscale vacuum gap on photon-enhanced thermionic emission devices

A new model of the photon-enhanced thermionic emission (PETE) device with a nanoscale vacuum gap is established by introducing the quantum tunneling effect and the image force correction. Analytic expressions for both the thermionic emission and tunneling currents are derived. The electron concentration and the temperature of the cathode are determined by the particle conservation and energy balance equations. The effects of the operating voltage on the maximum potential barrier, cathode temperature, electron concentration and equilibrium electron concentration of the conduction band, and efficiency of the PETE device are discussed in detail for different given values of the vacuum gap length. The influence of the band gap of the cathode and flux concentration on the efficiency is further analyzed. The maximum efficiency of the PETE and the corresponding optimum values of the band gap and the operating voltage are determined. The results obtained here show that the efficiency of the PETE device can be significantly improved by employing a nanoscale vacuum gap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗