Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Biomedical Imaging: SPECT and PET

Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are non-invasive nuclear imaging techniques relying on the use of tomographic reconstruction methods to provide 3D representations of the distribution of radiolabeled molecules in vivo. Differences in the underlying physical principles determine the achievable spatial resolution, sensitivity, specificity and observation time span of these two imaging modalities. Their specific characteristics are described and the current technology developments and design tradeoffs are reviewed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Nutrient canals and porosity of the bony palate: A basis for the biological plausibility of the anterior middle superior alveolar nerve block

Background. The authors investigated morphologic parameters of the palatal cortex that affect the diffusion of local anesthetic solution in the region of the anterior middle superior alveolar (AMSA) nerve block injection site. Methods. The authors used computed tomographic (CT) and micro-CT imaging to assess 20 human skulls from an anatomic collection. Analysis of the C1 images included frequency, distribution, and width of the nutrient canals in the bony palate, according to to the person's sex and age. Micro-CT analysis involved measuring the thickness and porosity of palatal cortical bone in the area of the AMSA injection site in relation to the thickness and porosity of the opposite buccal cortical bone. Results. There was a statistically significant difference (P = .042) in the location of the nutrient canals between male specimens (> 50% in the border region) and female specimens (> 50% in the palatal process). Furthermore, the female skulls had significantly wider nutrient canal foramina (P = .042) than did the male skulls. Despite greater thickness, the palatal cortex in the area of the AMSA injection site had slightly greater porosity than did the buccal cortex. A significantly greater number of microcanals penetrated the whole cortical thickness in palatal than in buccal cortical bone (P = .001). Conclusions. The distribution and width of nutrient canals differed between male and female skulls. At the microscopic level, structural characteristics of the palatal cortex provide a good anatomic basis for the potential of a satisfactory AMSA injection success rate. Practical Implications. The AMSA technique success rate might be increased if the clinician adjusts the injection site to the distribution of nutrient canals, depending on the sex of the patient.

60 APPLIED LIFE SCIENCES↗

Probiotics for Rectal Volume Variation During Radiation Therapy for Prostate Cancer

Purpose: To investigate the effect of the probiotic Lactobacillus acidophilus on the percentage volume change of the rectum (PVC{sub R}), a crucial factor of prostate movement. Methods and Materials: Prostate cancer patients managed with tomotherapy as a radical treatment were enrolled in the study to take a probiotic capsule containing 1.0 × 10{sup 8} colony-forming units of L acidophilus or a placebo capsule twice daily. Radiation therapy was performed at a dose of 78 Gy in 39 fractions. The PVC{sub R}, defined as the difference in rectal volume between the planning computed tomographic (CT) and daily megavoltage CT images, was analyzed. Results: Forty patients were randomized into 2 groups. The L acidophilus group showed significantly lower median rectal volume and median PVC{sub R} values than the placebo group. L acidophilus showed a significant reduction effect on the PVC{sub R} (P<.001). However, the radiation therapy fraction number did not significantly influence the PVC{sub R}. Conclusions: L acidophilus was useful in reducing the PVC{sub R}, which is the most important determining factor of prostate position, during radiation therapy for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

Hydrologic Impacts of a Strike-Slip Fault Zone: Insights from Joint 3D Body-Wave Tomography of Rock Valley

The Rock Valley fault zone (RVFZ), an intraplate strike-slip fault zone in the southern Nevada National Security Site (NNSS), hosted a series of very shallow (<3 km) earthquakes in 1993. The RVFZ may also have hydrological significance within the NNSS, potentially playing a role in regional groundwater flow, but there is a lack of local hydrological data. In the Spring of 2021, we collected active-source accelerated weight drop seismic data over part of the RVFZ to better characterize the shallow subsurface. Here, we manually picked ~17,000 P-wave travel times and over 14,000 S-wave travel times, which were inverted for P-wave velocity (V P ), S-wave velocity (V S ), and V P /V S ratio in a 3D joint tomographic inversion scheme. Seismic velocities are imaged as deep as ~700 m in areas and generally align with geologic and structural expectations. V P and V S are relatively reduced near mapped and inferred faults, with the most prominent lower V P and V S zone around the densest collection of faults. We image V P /V S ratios ranging from ~1.5 to ~2.4, the extremes of which occur at a depth of ~100 m and are juxtaposed across a fault. One possible interpretation of the imaged seismic velocities is enhanced fault damage near the densest collection of faults with relatively higher porosity and/or crack density at ~100 m depth, with patches of semiperched groundwater present in the sedimentary rock in higher V P /V S areas and drier rock in lower V P /V S areas. A relatively higher V P /V S area beneath the densest faults persists at depth, which suggests percolation of groundwater via the fault damage zone to the regionally connected lower carbonate aquifer. Potentially, the presence and movement of groundwater may have played a role in the 1993 earthquake aftershocks.

58 GEOSCIENCES↗

Soot Volume Fraction Imaging

A new technique is described for the full-field determination of soot volume fractions via laser extinction measurements. This technique differs from previously reported point-wise methods in that a two-dimensional array (i.e., image) of data is acquired simultaneously. In this fashion, the net data rate is increased, allowing the study of time-dependent phenomena and the investigation of spatial and temporal correlations. A telecentric imaging configuration is employed to provide depth-invariant magnification and to permit the specification of the collection angle for scattered light. To improve the threshold measurement sensitivity, a method is employed to suppress undesirable coherent imaging effects. A discussion of the tomographic inversion process is provided, including the results obtained from numerical simulation. Results obtained with this method from an ethylene diffusion flame are shown to be in close agreement with those previously obtained by sequential point-wise interrogation.

Greenberg, Paul S.↗

Coronal Polarization of Pseudostreamers and the Solar Polar Field Reversal

The reversal of the solar polar magnetic field is notoriously hard to pin down due to the extreme viewing angle of the pole. In Cycle 24, the southern polar field reversal can be pinpointed with high accuracy due to a large-scale pseudostreamer that formed over the pole and persisted for approximately a year. We tracked the size and shape of this structure with multiple observations and analysis techniques including PROBA2/SWAP EUV images, AIA EUV images, CoMP polarization data, and 3D tomographic reconstructions. We find that the heliospheric field reversed polarity in February 2014, whereas in the photosphere, the last vestiges of the previous polar field polarity remained until March 2015. We present here the evolution of the structure and describe its identification in the Fe XII 1074nm coronal emission line, sensitive to the Hanle effect in the corona.

magnetic field↗

Quantifying Spatially Varying Blur in X-ray Radiographic Imaging Systems

Two goals of quantitative analysis of radiographic data from dynamic material experiments are to identify edge locations and infer material density. Understanding the systematic effect of blur of the imaging system through calibration imagery is the fist step to quantifying, modeling, and eventually mitigating its effect. If modeling geometry and assumptions can be expressed through operator transformations, this leads to natural modifications of the likelihood and prior in a Bayesian formulation of the inverse problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-AB-207-00: Digital Tomosynthesis

Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact, the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.

60 APPLIED LIFE SCIENCES↗

TU-AB-207-01: Introduction to Tomosynthesis

Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact, the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.

60 APPLIED LIFE SCIENCES↗

TU-AB-207-02: Testing of Body and Breast Tomosynthesis Sytems

Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact, the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.

60 APPLIED LIFE SCIENCES↗

TU-AB-207-03: Tomosynthesis: Clinical Applications

Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact, the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.

60 APPLIED LIFE SCIENCES↗

Principal component analysis of modified gravity using weak lensing and peculiar velocity measurements

We perform a principal component analysis to assess ability of future observations to measure departures from General Relativity in predictions of the Poisson and anisotropy equations on linear scales. In particular, we focus on how the measurements of redshift-space distortions (RSD) observed from spectroscopic galaxy redshift surveys will improve the constraints when combined with lensing tomographic surveys. Assuming a Euclid-like galaxy imaging and redshift survey, we find that adding the 3D information decreases the statistical uncertainty by a factor between 3 and 7 compared to the case when only observables from lensing tomographic surveys are used. We also find that the number of well-constrained modes increases by a factor between 3 and 6. Our study indicates the importance of joint galaxy imaging and redshift surveys such as SuMIRe and Euclid to give more stringent tests of the ΛCDM model and to distinguish between various modified gravity and dark energy models.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrofluoroplanigraphy.

The authors describe a fluoroplanigraphic method of synthesizing single-plane sections of any desired layer within the body. This is done by appropriate positioning of the individual images obtained at various locations of the X-ray tube during a single tomographic motion, followed by electronic summation of each roentgenogram. A TV image of any desired body section is available within seconds of the original recording sequence.

Baily, N. A.↗

Motion correction for passive radiation imaging of small vessels in ship-to-ship inspections

Passive radiation detection remains one of the most acceptable means of ascertaining the presence of illicit nuclear materials. In maritime applications it is most effective against small to moderately sized vessels, where attenuation in the target vessel is of less concern. Unfortunately, imaging methods that can remove source confusion, localize a source, and avoid other systematic detection issues cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing system sensitivity. This is particularly true for the smaller watercraft, where passive inspections are most valuable. We have developed a combined gamma-ray, stereo visible-light imaging system that addresses this problem. Data from the stereo imager are used to track the relative location and orientation of the target vessel in the field of view of a coded-aperture gamma-ray imager. Using this information, short-exposure gamma-ray images are projected onto the target vessel using simple tomographic back-projection techniques, revealing the location of any sources within the target. Here,the complex autonomous tracking and image reconstruction system runs in real time on a 48-core workstation that deploys with the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of Fission Product Distribution from Tomographic Scans in TRISO Fuel Graphitic Matrix and Nuclear Grade Graphites

An image reconstruction method was developed to rectify shortcomings of earlier methods that became apparent as destructively sampled data became available. This reconstruction method was applied to the tomographic gamma scans of nuclear graphite and graphitic matrix samples from AGR-3/4. There is generally agreement between profiles measured via destructive sampling of these rings and profiles from tomographic reconstruction.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reconstruction of Fission Product Distribution from Tomographic Scans in TRISO Fuel Graphitic Matrix and Nuclear Grade Graphites

An image reconstruction method was developed to rectify shortcomings of earlier methods that became apparent as destructively sampled data became available. This reconstruction method was applied to the tomographic gamma scans of nuclear graphite and graphitic matrix samples from AGR-3/4. There is generally agreement between profiles measured via destructive sampling of these rings and profiles from tomographic reconstruction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗