Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Projecting Future Energy Production from Operating Wind Farms in North America. Part III: Variability

Abstract Daily expected wind power production from operating wind farms across North America are used to evaluate capacity factors (CF) computed using simulation output from the Weather Research and Forecasting (WRF) Model and to condition statistical models linking atmospheric conditions to electricity production. In Parts I and II of this work, we focus on making projections of annual energy production and the occurrence of electrical production drought. Here, we extend evaluation of the CF projections for sites in the Northeast, Midwest, southern Great Plains (SGP), and southwest U.S. coast (SWC) using statewide wind-generated electricity supply to the grid. We then quantify changes in the time scales of CF variability and the seasonality. Currently, wind-generated electricity is lowest in summer in each region except SWC, which causes a substantial mismatch with electricity demand. While electricity of residential heating may shift demand, research presented here suggests that summertime CF are likely to decline, potentially exacerbating the offset between seasonal peak power production and current load. The reduction in summertime CF is manifest for all regions except the SGP and appears to be linked to a reduction in synoptic-scale variability. Using fulfillment of 50% and 90% of annual energy production to quantify interannual variability, it is shown that wind power production exhibits higher (earlier fulfillment) or lower (later fulfillment) production for periods of over 10–30 years as a result of the action of internal climate modes. Significance Statement Electrical power system reassessment and redesign may be needed to aid efficient increased use of variable renewables in the generation of electricity. Currently wind-generated electricity in many regions of North America exhibits a minimum in summertime and hence is not well synchronized with electricity demand, which tends to be maximized in summer. Future projections indicate evidence of reductions in wind power during summer that would amplify this offset. However, electrification of heating may lead to increased wintertime demand, which would lead to greater synchronization.

Coburn, Jacob↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Osteoporosis Treatments Affect Bone Matrix Maturation in a Rat Model of Induced Cortical Remodeling

ABSTRACT To test how osteoporosis drugs affect bone matrix maturation during cortical bone remodeling, 72 pregnant rats were switched from a 0.4% to a 0.01% calcium diet at parturition for a 23‐day lactation period. At weaning, eight dams were sacrificed to establish baseline values, while the remaining dams were returned to 0.4% calcium and treated with vehicle (saline), sodium fluoride (NaF), zoledronic acid (ZA), or sclerostin antibody (Scl‐Ab) for either 7 or 28 days (eight animals per group per time point). Femora were examined by μCT, dynamic histomorphometry, Fourier transform infrared imaging, and three‐point bending of notched specimens. Cortical porosity decreased in all groups from baseline to day 28. Intracortical mineralizing surface (MS/BS) and mineral apposition rate (MAR), as well as the mineral‐to‐matrix ratio were unaffected by treatment, but intracortical crystallinity was increased in the ZA group at day 10 compared with vehicle. Cortical area increased in all groups over 28 days mainly because of an addition of bone at the endocortical surface. Endocortical MS/BS did not vary among the groups, but endocortical MAR was suppressed in the NaF group at day 2 and elevated in the Scl‐Ab group at day 4 compared with vehicle. Endocortical mineral‐to‐matrix ratio was increased at days 5 and 10 following NaF treatment and endocortical crystallinity was increased at day 5 following ZA treatment compared with vehicle. Fracture toughness did not differ among the groups. Thus, the treatments affected matrix maturation more strongly at the endocortical then intracortical envelope. In this model of induced remodeling, the bone formation phase is synchronized at multiple sites, facilitating study of the effects of drugs or other bone‐targeting agents on matrix maturation independent of their effects on the initiation of remodeling. © 2020 The Authors. JBMR Plus published by Wiley Periodicals, Inc. on behalf of American Society for Bone and Mineral Research.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Analysis of Speculative Parallel Adaptive Local Timestepping for Conservation Laws

Stable simulation of conservation laws, such as those used to model fluid dynamics and plasma physics applications, requires the satisfaction of the so-called Courant-Friedrichs-Lewy condition. By allowing regions of the mesh to advance with different timesteps that locally satisfy this stability constraint, significant work reduction can be attained when compared to a time integration scheme using a single timestep size. However, parallelizing this algorithm presents considerable difficulty. Since the stability condition depends on the state of the system, dependencies become dynamic and potentially non-local. In this article, we present an adaptive local timestepping algorithm using an optimistic (Timewarp-based) parallel discrete event simulation. We introduce waiting heuristics to limit misspeculation and a semi-static load balancing scheme to eliminate load imbalance as parts of the mesh require finer or coarser timesteps. Last, we outline an interface for separating the physics of the specific conservation law from the temporal integration allowing for productive adoption of our proposed algorithm. We present a misspeculation study for three conservation laws, demonstrating both the productivity of the local timestepping API, for which 74% of the lines of code are reused across different conservation laws, and the robustness of the waiting heuristics—at most 1.5% of element updates are rolled back. Our performance studies demonstrate up to a 2.8× speedup versus a baseline unoptimized local timestepping approach, a 4x improvement in per-node throughput compared to an MPI parallelization of synchronous timestepping, and scalability up to 3,072 cores on NERSC’s Cori Haswell partition.

97 MATHEMATICS AND COMPUTING↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Decentralized Distributed Proximal Policy Optimization (DD-PPO) for High Performance Computing Scheduling on Multi-User Systems

Resource allocation in High Performance Computing (HPC) environments presents a complex and multifaceted challenge for job scheduling algorithms. Beyond the efficient allocation of system resources, schedulers must account for and optimize multiple performance metrics, including job wait time and system throughput. Traditional heuristic-based scheduling algorithms increasingly struggle and lack the efficiency needed to meet the demands and address the complexity and scale of modern HPC systems. Consequently, recent research efforts have focused on leveraging advancements in Artificial Intelligence (AI) and Deep Learning (DL), particularly Reinforcement Learning (RL), to develop more adaptable and intelligent scheduling strategies. Previous RL-based scheduling approaches have explored a range of algorithms, from Deep Q-Networks (DQN) to Proximal Policy Optimization (PPO), and more recently, hybrid methods that integrate Graph Neural Networks (GNNs) with RL techniques. However, a common limitation across these methods is their reliance on relatively small datasets, with few methods being evaluated using large-scale, multi-million-job trace datasets representative of real-world HPC workloads. Moreover, existing RL schedulers face scalability issues due to centralized policy updates, which hinder training efficiency and performance when applied to large datasets. This study introduces a novel RL-based scheduler utilizing Decentralized Distributed Proximal Policy Optimization (DD-PPO) algorithm, which supports large-scale distributed training across multiple workers without requiring parameter synchronization at every step. By eliminating reliance on centralized updates to a shared policy, the DD-PPO scheduler enhances scalability, training efficiency, and sample utilization. Experimental validation using a large real-world dataset containing over 11.5 million job traces collected from petascale HPC systems over six years assesses the influence of dataset scale on training effectiveness and compares DD-PPO performance to traditional and advanced scheduling approaches. The experimental results demonstrate improved scheduling performance in comparison to both heuristic-based schedulers and existing RL-based scheduling algorithms.

AI↗

Matching high resolution satellite data and flux tower footprints improves their agreement in photosynthesis estimates

Mapping canopy photosynthesis in both high spatial and temporal resolution is essential for carbon cycle monitoring in heterogeneous areas. However, well established satellites in sun-synchronous orbits such as Sentinel-2, Landsat and MODIS can only provide either high spatial or high temporal resolution but not both. Recently established CubeSat satellite constellations have created an opportunity to overcome this resolution trade-off. In particular, Planet Fusion allows full utilization of the CubeSat data resolution and coverage while maintaining high radiometric quality. In this study, we used the Planet Fusion surface reflectance product to calculate daily, 3-m resolution, gap-free maps of the near-infrared radiation reflected from vegetation (NIRvP). We then evaluated the performance of these NIRvP maps for estimating canopy photosynthesis by comparing with data from a flux tower network in Sacramento-San Joaquin Delta, California, USA. Overall, NIRvP maps captured temporal variations in canopy photosynthesis of individual sites, despite changes in water extent in the wetlands and frequent mowing in the crop fields. When combining data from all sites, however, we found that robust agreement between NIRvP maps and canopy photosynthesis could only be achieved when matching NIRvP maps to the flux tower footprints. In this case of matched footprints, NIRvP maps showed considerably better performance than in situ NIRvP in estimating canopy photosynthesis both for daily sum and data around the time of satellite overpass (R2 = 0.78 vs. 0.60, for maps vs. in situ for the satellite overpass time case). This difference in performance was mostly due to the higher degree of consistency in slopes of NIRvP-canopy photosynthesis relationships across the study sites for flux tower footprint-matched maps. Our results show the importance of matching satellite observations to the flux tower footprint and demonstrate the potential of CubeSat constellation imagery to monitor canopy photosynthesis remotely at high spatio-temporal resolution.

54 ENVIRONMENTAL SCIENCES↗

Experimental Investigation of Interactions Between Two Closely Spaced Azimuthal Modes in a Multinozzle Can Combustor

Thermoacoustic instabilities in annular or circular combustors are often coupled with azimuthal modes. These modes can be characterized by a spin ratio (SR), which quantifies the dominant mode between two counter-rotating waves, and a phase difference between them, which is directly related to the orientation of the antinodal line. This study investigates the instability amplitudes, SR, and phase difference of two closely spaced (3% of their mean frequency), yet distinct azimuthal modes; one is the first azimuthal (1A) mode, and the other is a combination of first azimuthal and first longitudinal (1A1L) mode. Each mode itself consists of two peaks that are spaced even more closely in frequency (0.8%). Furthermore, distinct harmonics at 2× and 3× of these frequencies, presumably associated with nonlinearities, are also evident in the spectra. Each mode is bandpass filtered in spectrum to analyze them separately. For the 1A mode, the SR and phase difference exhibit a variety of behaviors—including quasi-periodic standing waves, spinning waves, and intermittency—depending on operating conditions such as thermal power and azimuthal fuel staging. Similar trends are observed for the 1A1 L mode. Moreover, there is clear coupling between the 1A and 1A1 L modes, as their SRs are almost synchronized during the quasi-periodic standing wave. This synchronization is observed in phase differences as well, but not in the instability amplitude. For spinning dominant wave conditions, the SRs of each mode have similar average values, but they fluctuate in a seemingly random fashion. For the phase difference, both average and fluctuation are not correlated. In contrast, the instability amplitudes are strongly correlated, with modulation of the 1A mode leading to that of the 1A1 L mode. Furthermore, these results clearly indicate that complex coupling occurs across closely spaced frequencies under instability conditions, coupling that must be understood in order to capture limit cycle dynamics.

33 ADVANCED PROPULSION SYSTEMS↗

Covariation of Slab Tracers, Volatiles, and Oxidation During Subduction Initiation

Abstract Subduction‐related lavas have higher Fe 3+ /∑Fe than midocean ridge basalts (MORB). Hypotheses for this offset include imprint from subducting slabs and differentiation in thickened crust. These ideas are readily tested through examination of the time‐dependent evolution of slab‐derived signatures, thickening crust of the overriding plate, and evolving redox during subduction initiation. Here, we present Fe 3+ /ΣFe and volatile element abundances of volcanic glasses recovered from International Ocean Discovery Program (IODP) Expedition 352 to the Izu‐Bonin‐Mariana (IBM) forearc. The samples include forearc basalts (FAB) that are stratigraphically overlain by low‐ and high‐silica boninite lavas. The FAB glasses have 0.18–0.85 wt% H 2 O, 75–233 ppm CO 2 , S contents controlled by saturation with a sulfide phase (602–1,386 ppm), Ba/La from 3.9‐10, and Fe 3+ /ΣFe ratios from 0.136 to 0.177. These compositions are similar to MORB and suggest that decompression melting of dry and reduced mantle dominates the earliest stages of subduction initiation. Low‐ and high‐silica boninite glasses have 1.51–3.19 wt% H 2 O, CO 2 below detection, S contents below those required for sulfide saturation (5–235 ppm), Ba/La from 11 to 29, and Fe 3+ /∑Fe from 0.181 to 0.225. The compositions are broadly similar to modern arc lavas in the IBM arc. These data demonstrate that the establishment of fluid‐fluxed melting of the mantle, which occurs in just 0.6–1.2 my after subduction initiation, is synchronous with the production of oxidized, mantle‐derived magmas. The coherence of high Fe 3+ /∑Fe and Ba/La ratios with high H 2 O contents in Expedition 352 glasses and the modern IBM arc rocks strongly links the production of oxidized arc magmas to signatures of slab dehydration.

Brounce, Maryjo↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

From BEYONDPLANCK to COSMOGLOBE: Preliminary WMAP Q -band analysis

We present the first application of the COSMOGLOBE analysis framework by analyzing nine-year WMAP time-ordered observations that uses similar machinery to that of BEYONDPLANCK for the Planck Low Frequency Instrument (LFI). We analyzed only the Q-band (41 GHz) data and report on the low-level analysis process based on uncalibrated time-ordered data to calibrated maps. Most of the existing BEYONDPLANCK pipeline may be reused for WMAP analysis with minimal changes to the existing codebase. The main modification is the implementation of the same preconditioned biconjugate gradient mapmaker used by the WMAP team. Producing a single WMAP Q1-band sample requires 22 CPU-hrs, which is slightly more than the cost of a Planck 44 GHz sample of 17 CPU-hrs; this demonstrates that a full end-to-end Bayesian processing of the WMAP data is computationally feasible. In general, our recovered maps are very similar to the maps released by the WMAP team, although with two notable differences. In terms of temperature, we find a ~2 μK quadrupole difference that most likely is caused by different gain modeling, while in polarization we find a distinct 2.5 μK signal that has been previously referred to as poorly measured modes by the WMAP team. In the COSMOGLOBE processing, this pattern arises from temperature-to-polarization leakage from the coupling between the CMB Solar dipole, transmission imbalance, and sidelobes. No traces of this pattern are found in either the frequency map or TOD residual map, suggesting that the current processing has succeeded in modeling these poorly measured modes within the assumed parametric model by using Planck information to break the sky-synchronous degeneracies inherent in the WMAP scanning strategy.

79 ASTRONOMY AND ASTROPHYSICS↗

Joint scheduling of energy, fast and primary frequency response reserves in integrated transmission–distribution networks

Inverter-based distributed energy resources (DERs) connected to distribution networks (DNs) can provide fast frequency support, but their reserve deliverability depends on feeder constraints and differs from synchronous primary frequency response (PFR). Existing transmission–distribution coordination studies usually treat reserve generically or neglect feeder-level feasibility, while frequency-security scheduling studies rarely represent distribution feeders explicitly. This paper develops a bi-level day-ahead scheduling framework for integrated transmission–distribution networks that jointly clears energy, transmission-side PFR, and distribution-side fast frequency response (FFR) under exogenous hourly inertia and largest-loss inputs from an external unit commitment (UC) schedule. The transmission problem is modeled with DC-optimal power flow (OPF) and closed-form second-order cone (SOC) frequency-security constraints, whereas each DN is represented by a reserve-aware branch-flow AC-OPF so that scheduled fast reserves remain deliverable during activation. The bi-level problem is reformulated through Karush–Kuhn–Tucker (KKT) conditions into a mixed-integer SOC program, and a penalty term is used to tighten the distribution-network relaxation. In the reduced test system, lower exogenous inertia increased the required primary response from 179.64 MW to 191.08 MW, distribution-side fast response reduced total frequency-response procurement by up to 4.9%, and neglecting distribution constraints overstated the combined distribution-side energy and reserve award by up to 18%. In the expanded study, the largest case was solved in 2.02 s with a 0.00% optimality gap. Time-domain simulations kept the frequency nadir above 59.0 Hz in all tested hours. These results demonstrate the value of fast-response modeling and distribution-feasible reserve delivery in coordinated market clearing.

Noh, Seung-Gil↗

Droop Control-Based Dispatch of an Islanded Microgrid with Multiple Grid-Forming Sources: Preprint

Before rotating fossil-fuel based synchronous generators (SGs) are phased out in line with renewable goals, grid-forming (GFM) inverters are expected to parallel with SGs. Primary droop control allows them share power without communication, however, it is necessary to dispatch GFM inverters and/or SG with desired output power for better energy management (e.g., one GFM inverter needs to charge the battery due to low state-of-the charge). Therefore, this paper develops analytic approach to dispatch GFM inverters and SG with desired output power by shifting the droop intercept up/down while maintain the same frequency operating point for improved transient stability. This concept is demonstrated through pure hardware setup with two off-the-shelf inverters and one diesel generator under islanded microgrid, and we also provide insight on real-world implementation of the proposed concept.

droop control↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of transverse electron pulse trains using RF powered traveling wave metallic comb striplines

Advancements in ultrafast electron microscopy have allowed elucidation of spatially selective structural dynamics. However, as the spatial resolution and imaging capabilities have made progress, quantitative characterization of the electron pulse trains has not been reported at the same rate. In fact, inexperienced users have difficulty replicating the technique because only a few dedicated microscopes have been characterized thoroughly. Systems replacing laser driven photoexcitation with electrically driven deflectors especially suffer from a lack of quantified characterization because of the limited quantity. The primary advantages to electrically driven systems are broader frequency ranges, ease of use and simple synchronization to electrical pumping. Here, we characterize the technical parameters for electrically driven UEM including the shape, size and duration of the electron pulses using low and high frequency chopping methods. At high frequencies, pulses are generated by sweeping the electron beam across a chopping aperture. For low frequencies, the beam is continuously forced off the optic axis by a DC potential, then momentarily aligned by a countering pulse. Using both methods, we present examples that measure probe durations of 2 ns and 10 ps for the low and high frequency techniques, respectively. Here, we also discuss how the implementation of a pulsed probe affects STEM imaging conditions by adjusting the first condenser lens.

36 MATERIALS SCIENCE↗

Quantum Frequency Combs with Path Identity for Quantum Remote Sensing

Quantum sensing promises to revolutionize sensing applications by employing quantum states of light or matter as sensing probes. Photons are the clear choice as quantum probes for remote sensing because they can travel to and interact with a distant target. Existing schemes are mainly based on the quantum illumination framework, which requires quantum memory to store a single photon of an initially entangled pair until its twin reflects off a target and returns for final correlation measurements. Existing demonstrations are limited to tabletop experiments, and expanding the sensing range faces various roadblocks, including long-time quantum storage and photon loss and noise when transmitting quantum signals over long distances. We propose a novel quantum sensing framework that addresses these challenges using quantum frequency combs with path identity for remote sensing of signatures (“qCOMBPASS”). The combination of one key quantum phenomenon and two quantum resources—namely, quantum-induced coherence by path identity, quantum frequency combs, and two-mode squeezed light—allows for quantum remote sensing without requiring quantum memory. The proposed scheme is akin to a quantum radar based on entangled frequency-comb pairs that uses path identity to detect, range, or sense a remote target of interest by measuring pulses of one comb in the pair that never traveled to the target but that contains target information “teleported” by quantum-induced coherence by path identity from the other comb in the pair that traveled to the target but is not detected. We develop the basic qCOMBPASS theory, analyze the properties of the qCOMBPASS transceiver, and introduce the qCOMBPASS equation—a quantum analog of the well-known LIDAR equation in classical remote sensing. We also describe an experimental scheme to demonstrate the concept using two-mode squeezed quantum combs. qCOMBPASS can strongly impact various applications in remote quantum sensing, imaging, metrology, and communications. These applications include detection and ranging of low-reflectivity objects, measurement of small displacements of a remote target with precision beyond the standard quantum limit (SQL), standoff hyperspectral quantum imaging, discreet surveillance from space with low detection probability (detect without being detected), very-long-baseline interferometry, quantum Doppler sensing, quantum clock synchronization, and networks of distributed quantum sensors. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Decoupling of peeling and ballooning thresholds for pedestal stability and reduction in ELM frequency via enhanced turbulence with edge electron cyclotron heating in DIII-D

Abstract The edge localized mode (ELM) frequency ( f ELM ) decreased by 63% when electron cyclotron heating (ECH) deposition location is shifted from ρ = 0.4 to ρ = 0.8 in DIII-D discharges where the power ratio between neutral beam injection (NBI) and ECH ( P NBI / P ECH ) is kept at ∼1. The performance of the pedestal in the ECH heated case is compared with a pure NBI reference discharge while keeping the total input power constant. All these discharges are performed at balanced input torque conditions. Furthermore, in the pure NBI discharge a strong decoupling of the peeling–ballooning (PB) thresholds is observed. The PB decoupling is preserved when the ECH is deposited at ρ = 0.8 and P NBI / P ECH ∼ 1, while the thresholds manifest a closed stability boundary when the ECH is deposited at ρ = 0.4. The inter-ELM pedestal recovery time is considerably larger for the ECH at ρ = 0.8 case. Increased pedestal turbulence is observed in beam emission spectroscopy (BES), Doppler backscattering and magnetic diagnostics for the ECH at the ρ = 0.8 case. Strong growth of a TEM-like mode is observed in BES and the mode growth is correlated with the decrease in f ELM . In view of these observations, the increased pedestal turbulence seems to be the plausible reason behind the delayed pedestal recovery following an ELM event in the ECH at ρ = 0.8 case, and the preservation of PB decoupling through temperature pedestal profile widening. TRANSP interpretative simulations show that the ECH at the ρ = 0.8 case is more susceptible to ITG/TEM turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗