Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

DISCOVERY OF THE TRANSIENT MAGNETAR 3XMM J185246.6+003317 NEAR SUPERNOVA REMNANT KESTEVEN 79 WITH XMM-NEWTON

We report the serendipitous discovery with XMM-Newton that 3XMM J185246.6+003317 is an 11.56 s X-ray pulsar located 1' away from the southern boundary of supernova remnant Kes 79. The spin-down rate of 3XMM J185246.6+003317 is <1.1 × 10{sup –13} s s{sup –1}, which, together with the long period P = 11.5587126(4) s, indicates a dipolar surface magnetic field of <3.6 × 10{sup 13} G, a characteristic age of >1.7 Myr, and a spin-down luminosity of <2.8 × 10{sup 30} erg s{sup –1}. Its X-ray spectrum is best-fitted with a resonant Compton scattering model and also can be adequately described by a blackbody model. The observations covering a seven-month span from 2008 to 2009 show variations in the spectral properties of the source, with the luminosity decreasing from 2.7 × 10{sup 34} erg s{sup –1} to 4.6 × 10{sup 33} erg s{sup –1}, along with a decrease of the blackbody temperature from kT ≈ 0.8 keV to ≈0.6 keV. The X-ray luminosity of the source is higher than its spin-down luminosity, ruling out rotation as a power source. The combined timing and spectral properties, the non-detection of any optical or infrared counterpart, together with the lack of detection of the source in archival X-ray data prior to the 2008 XMM-Newton observation, point to 3XMM J185246.6+003317 being a newly discovered transient low-B magnetar undergoing an outburst decay during the XMM-Newton observations. The non-detection by Chandra in 2001 sets an upper limit of 4 × 10{sup 32} erg s{sup –1} to the quiescent luminosity of 3XMM J185246.6+003317. Its period is the longest among currently known transient magnetars. The foreground absorption toward 3XMM J185246.6+003317 is similar to that of Kes 79, suggesting a similar distance of ∼7.1 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

The cluster charge identification in the GEM detector for fusion plasma imaging by soft X-ray diagnostics

The measurement system based on gas electron multiplier detector is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an X-ray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value, and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals, and cluster charge values corresponding to the energy spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Contribution of Contemporary Carbon Sources to Size-Fractionated Particulate Matter and Time-Resolved Bulk Particulate Matter Using the Measurement of Radiocarbon

This study was motivated by a desire to improve understanding of the sources contributing to the carbon that is an important component of airborne particulate matter (PM). The ultimate goal of this project was to lay a ground work for future tools that might be easily implemented with archived or routinely collected samples. A key feature of this study was application of radiocarbon measurement that can be interpreted to indicate the relative contributions from fossil and non-fossil carbon sources of atmospheric PM. Size-resolved PM and time-resolved PM{sub 10} collected from a site in Sacramento, CA in November 2007 (Phase I) and March 2008 (Phase II) were analyzed for radiocarbon and source markers such as levoglucosan, cholesterol, and elemental carbon. Radiocarbon data indicates that the contributions of non-fossil carbon sources were much greater than that from fossil carbon sources in all samples. Radiocarbon and source marker measurements confirm that a greater contribution of non-fossil carbon sources in Phase I samples was highly likely due to residential wood combustion. The present study proves that measurement of radiocarbon and source markers can be readily applied to archived or routinely collected samples for better characterization of PM sources. More accurate source apportionment will support ARB in developing more efficient control strategies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of Interrupted Helium Flow in the Analysis of Vapor Samples with Flowing Atmospheric-Pressure Afterglow-Mass Spectrometry

The flowing atmospheric-pressure afterglow (FAPA) source was used for the mass-spectrometric analysis of vapor samples introduced between the source and mass spectrometer inlet. Through interrupted operation of the plasma-supporting helium flow, helium consumption is greatly reduced and dynamic gas behavior occurs that was characterized by schlieren imaging. Moreover, mass spectra acquired immediately after the onset of helium flow exhibit a signal spike before declining and ultimately reaching a steady level. This initial signal appears to be due to greater interaction of sample vapor with the afterglow of the source when helium flow resumes. In part, the initial spike in signal can be attributed to a pooling of analyte vapor in the absence of helium flow from the source. Finally, time-resolved schlieren imaging of the helium flow during on and off cycles provided insight into gas-flow patterns between the FAPA source and the MS inlet that were correlated with mass-spectral data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ML-Shock-Time-Series-Synthesis

Open-source machine learning tools for GPU-batched synthetic shock time-series generation, GPU-accelerated batched Shock Response Spectrum (SRS) computation, and standardized benchmark datasets.

Watts, Adam↗

EXPLORING THE TIME DISPERSION OF THE IBEX-HI ENERGETIC NEUTRAL ATOM SPECTRA AT THE ECLIPTIC POLES

The Interstellar Boundary Explorer (IBEX) has observed energetic neutral atom (ENA) hydrogen emissions from the edge of the solar system for more than three years. The observations span energies from 0.01 to 6 keV FWHM. At energies greater than 0.5-6 keV, and for a travel distance of {approx}100 AU, the travel time difference between the slowest and the fastest ENA is more than a year. Therefore, we construct spectra including the effect that slower ENAs left the source at an earlier time than faster ones. If the source produces a steady rate of ENAs and the extinction does not vary, then we expect that the spectral shape would be time independent. However, while the extinction of ENAs has been fairly constant during the first two and a half years, the source appears to have changed, and thus the spectra at a single time may not represent the conditions at the source. IBEX's viewing allows continuous sampling of the ecliptic poles where fluxes can be continuously monitored. For a given source distance we construct spectra assuming that the measured ENAs left the source at roughly the same time. To accomplish this construction, we apply time lag corrections to the signal at different ENA energies that take into account the travel time difference. We show that the spectral shape at the poles exhibits a statistically significant change with time.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Groundwater Age and Recharge Source on Nitrate Concentrations in Domestic Wells in the San Joaquin Valley

Nitrate is one of the most abundant contaminants in groundwater globally, in the United States, and in California (CA). We studied well construction information, water chemistry, stable isotopes, and noble gases to understand how groundwater travel time and recharge source and mechanism control nitrate concentrations in domestic wells in the San Joaquin Valley (SJV), CA, a large semiarid, irrigated agricultural region. Using nonparametric statistics, we find a decreasing trend in nitrates with groundwater travel time and well depth. Samples collected from wells that are closer to rivers and that show indications of river water recharge, either low recharge temperature or low δ 18 O signature, have lower concentrations of nitrates than samples with isotopic signatures indicating mixed source or local precipitation recharge. The curbing effect of river water recharge on nitrate concentrations in domestic wells is similar for direct river recharge and water applied as irrigation. This suggests that irrigation with river water also has a diluting effect that reduces the concentration of nitrate found in groundwater. This conclusion supports the idea that flood-managed aquifer recharge may be considered for remediation of groundwater nitrate when designing replenishment of aquifers.

54 ENVIRONMENTAL SCIENCES↗

Phase-Space Manipulation of Ultracold Ion Bunches with Time-Dependent Fields

All applications of high brightness ion beams depend on the possibility to precisely manipulate the trajectories of the ions or, more generally, to control their phase-space distribution. We show that the combination of a laser-cooled ion source and time-dependent acceleration fields gives new possibilities to perform precise phase-space control. We demonstrate reduction of the longitudinal energy spread and realization of a lens with control over its focal length and sign, as well as the sign of the spherical aberrations. This creates new possibilities to correct for the spherical and chromatic aberrations which are presently limiting the spatial resolution.

43 PARTICLE ACCELERATORS↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atmospheric CO2 simulation inside GEOS-5: Data mining, evaluation and treaty verification

We present an example of a simulated global climate model that is intended to stream real-time NASA data into the geophysical and climate science and assessment community over the next 5-10 years. It is known that the 3-D atmospheric wave structures and transport physics interact with spatially and time varying surface sources and sinks of CO{sub 2}, and that this communication between surface and atmosphere results in an exceedingly complicated evolution of atmospheric CO{sub 2} in time and space. Data mining techniques may be applied to the further development this 4-D model by incorporating satellite-generated data sets for hundreds of geophysical climate variables into existing simulation structures. These data sets are on the order of hundreds of Terabytes. Data mining will allow the determination of the fluxes of atmospheric CO{sub 2}. Data mining and knowledge acquisition contribute to the accurate determination of the sources and sinks of atmospheric CO{sub 2}, facilitating among other scientific discoveries, global treaty verification.

54 ENVIRONMENTAL SCIENCES↗

SU-G-201-17: Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)

Purpose: To investigate quantitatively the accuracy of dose distributions for the Ir-192 high-dose-rate (HDR) brachytherapy source calculated by the Brachytherapy-Planning system (BPS) and measured using a multiple-array-diode-detector in a heterogeneous medium. Methods: A two-dimensional diode-array-detector system (MapCheck2) was scanned with a catheter and the CT-images were loaded into the Varian-Brachytherapy-Planning which uses TG-43-formalism for dose calculation. Treatment plans were calculated for different combinations of one dwell-position and varying irradiation times and different-dwell positions and fixed irradiation time with the source placed 12mm from the diode-array plane. The calculated dose distributions were compared to the measured doses with MapCheck2 delivered by an Ir-192-source from a Nucletron-Microselectron-V2-remote-after-loader. The linearity of MapCheck2 was tested for a range of dwell-times (2–600 seconds). The angular effect was tested with 30 seconds irradiation delivered to the central-diode and then moving the source away in increments of 10mm. Results: Large differences were found between calculated and measured dose distributions. These differences are mainly due to absence of heterogeneity in the dose calculation and diode-artifacts in the measurements. The dose differences between measured and calculated due to heterogeneity ranged from 5%–12% depending on the position of the source relative to the diodes in MapCheck2 and different heterogeneities in the beam path. The linearity test of the diode-detector showed 3.98%, 2.61%, and 2.27% over-response at short irradiation times of 2, 5, and 10 seconds, respectively, and within 2% for 20 to 600 seconds (p-value=0.05) which depends strongly on MapCheck2 noise. The angular dependency was more pronounced at acute angles ranging up to 34% at 5.7 degrees. Conclusion: Large deviations between measured and calculated dose distributions for HDR-brachytherapy with Ir-192 may be improved when considering medium heterogeneity and dose-artifact of the diodes. This study demonstrates that multiple-array-diode-detectors provide practical and accurate dosimeter to verify doses delivered from the brachytherapy Ir-192-source.

60 APPLIED LIFE SCIENCES↗

A COMPARISON OF X-RAY AND MID-INFRARED SELECTION OF OBSCURED ACTIVE GALACTIC NUCLEI

We compare the relative merits of active galactic nuclei (AGNs) selection at X-ray and mid-infrared wavelengths using data from moderately deep fields observed by both Chandra and Spitzer. The X-ray-selected AGN sample and associated photometric and spectroscopic optical follow-up are drawn from a subset of fields studied as part of the Serendipitous Extragalactic X-ray Source Identification (SEXSI) program. Mid-infrared data in these fields are derived from targeted and archival Spitzer imaging, and mid-infrared AGN selection is accomplished primarily through application of the Infrared Array Camera (IRAC) color-color AGN 'wedge' selection technique. Nearly all X-ray sources in these fields which exhibit clear spectroscopic signatures of AGN activity have mid-infrared colors consistent with IRAC AGN selection. These are predominantly the most luminous X-ray sources. X-ray sources that lack high-ionization and/or broad lines in their optical spectra are far less likely to be selected as AGNs by mid-infrared color selection techniques. The fraction of X-ray sources identified as AGNs in the mid-infrared increases monotonically as the X-ray luminosity increases. Conversely, only 22% of mid-infrared-selected AGNs are detected at X-ray energies in the moderately deep ((t{sub exp}) approx 100 ks) SEXSI Chandra data. We hypothesize that IRAC sources with AGN colors that lack X-ray detections are predominantly high-luminosity AGNs that are obscured and/or lie at high redshift. A stacking analysis of X-ray-undetected sources shows that objects in the mid-infrared AGN selection wedge have average X-ray fluxes in the 2-8 keV band 3 times higher than sources that fall outside the wedge. Their X-ray spectra are also harder. The hardness ratio of the wedge-selected stack is consistent with moderate intrinsic obscuration, but is not suggestive of a highly obscured, Compton-thick source population. It is evident from this comparative study that in order to create a complete, unbiased census of supermassive black hole growth and evolution, a combination of sensitive infrared, X-ray, and hard X-ray selection is required. We conclude by discussing what samples will be provided by upcoming survey missions such as WISE, eROSITA, and NuSTAR.

79 ASTRONOMY AND ASTROPHYSICS↗

CHANDRA OBSERVATIONS OF SGR 1627-41 NEAR QUIESCENCE

We report on an observation of SGR 1627-41 made with the Chandra X-Ray Observatory on 2011 June 16. Approximately three years after its outburst activity in 2008, the source's flux has been declining, as it approaches its quiescent state. For an assumed power-law spectrum, we find that the absorbed 2-10 keV flux for the source is 1.0{sup +0.3}{sub -0.2} Multiplication-Sign 10{sup -13} erg cm{sup -2} s{sup -1} with a photon index of 2.9 {+-} 0.8 (N{sub H} = 1.0 Multiplication-Sign 10{sup 23} cm{sup -2}). This flux is approximately consistent with that measured at the same time after the source's outburst in 1998. With measurements spanning three years after the 2008 outburst, we analyze the long-term flux and spectral evolution of the source. The flux evolution is well described by a double exponential with decay times of 0.5 {+-} 0.1 and 59 {+-} 6 days, and a thermal cooling model fit suggests that SGR 1627-41 may have a hot core (T{sub c} {approx} 2 Multiplication-Sign 10{sup 8} K). We find no clear correlation between flux and spectral hardness as found in other magnetars. We consider the quiescent X-ray luminosities of magnetars and the subset of rotation-powered pulsars with high magnetic fields (B {approx}> 10{sup 13} G) in relation to their spin-inferred surface magnetic field strength and find a possible trend between the two quantities.

79 ASTRONOMY AND ASTROPHYSICS↗

REANALYSIS OF F-STATISTIC GRAVITATIONAL-WAVE SEARCHES WITH THE HIGHER CRITICISM STATISTIC

We propose a new method of gravitational-wave detection using a modified form of higher criticism, a statistical technique introduced by Donoho and Jin. Higher criticism is designed to detect a group of sparse, weak sources, none of which are strong enough to be reliably estimated or detected individually. We apply higher criticism as a second-pass method to synthetic F-statistic and C-statistic data for a monochromatic periodic source in a binary system and quantify the improvement relative to the first-pass methods. We find that higher criticism on C-statistic data is more sensitive by {approx}6% than the C-statistic alone under optimal conditions (i.e., binary orbit known exactly) and the relative advantage increases as the error in the orbital parameters increases. Higher criticism is robust even when the source is not monochromatic (e.g., phase-wandering in an accreting system). Applying higher criticism to a phase-wandering source over multiple time intervals gives a {approx}> 30% increase in detectability with few assumptions about the frequency evolution. By contrast, in all-sky searches for unknown periodic sources, which are dominated by the brightest source, second-pass higher criticism does not provide any benefits over a first-pass search.

79 ASTRONOMY AND ASTROPHYSICS↗

Geometric Interpretation of the Cluster Location Problem Part I: Theory

We present a new framing of the seismic location problem using principles drawn from differential geometry. Our interpretation relies upon the common assumption that travel times observed across a network are continuous, differentiable functions of source location. In consequence, travel‐time functions constitute a differentiable map between the source region and a Riemannian manifold. The manifold is said to be the image of the source region embedded in a generally high‐dimension travel‐time vector space. A cluster of events in the source region has an image of discrete points on the manifold, that, except in the simplest cases, cannot be viewed directly. However, it is possible to project the image of a cluster into a tangent space of the manifold for direct visualization. The projection operator can be computed directly from the data without a velocity model, but produces a distorted rendering of the cluster geometry. With a model we can predict the distortions and correct them to estimate cluster geometry. We develop these points with the simplest possible example, one for which direct visualization of the manifold is possible, using the example as an introduction to the relevant concepts from differential geometry in a familiar setting. The tangent space, a local linearization of the manifold, plays a key role. We develop a metric to estimate the limits of linearization, that is, to determine when the curvature of the manifold invalidates the linear assumption. We also examine the interplay of model error, inadequate network geometry, and pick error. We then generalize our results from the simple case to the general case of 3D source regions observed by general networks. Although we do suggest a new “project and correct” method for location, we do not develop it into a practical algorithm. In conclusion, our intention rather is to highlight new analytical methods grounded in differential geometry.

East Pacific Ocean Islands↗

Data Release Report for Source Physics Experiment 4Prime (SPE-4Prime) Nevada National Security Site (Revision 1)

The fourth test in the Source Physics Experiment series (SPE-4Prime) was conducted at a granite site in Nevada on May 21, 2015, at 18:35:44.000,003,989 ± 20 nanoseconds Coordinated Universal Time. The explosive source was 69.1 kilograms (kg) (including detonator assembly) of Composition C4 plastic explosive (89.14 kg TNT equivalent) detonated at a depth of 87.2 meters (m). The explosion was recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers installed at various depths from 7 to 99 m in boreholes positioned around the source hole, and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and three-component accelerometers at distances of 100 m to 25 kilometers. Infrasound data were collected from ground-based sensor arrays at distances out to 5 kilometers. This revised document includes a new Section 3.2.2, which is a discussion of clock timing issues discovered at four far-field stations.

58 GEOSCIENCES↗

Statistical Analysis of Incoherent Pulse Shaping

The performance of incoherent pulse shaping based on temporal gating and dispersive propagation of a broadband incoherent optical source is analyzed. The average temporal intensity of the dispersed gated source is essentially proportional to the spectral density of the incoherent source scaled along the temporal axis; therefore temporal waveforms are synthesized by spectral density modulation of the incoherent source. Although the coherence time of the shaped waveform is longer than that of the initial incoherent source, the shaped-intensity probability density function at any given time is identical to the probability density function of a polarized incoherent source. This restricts the signal-to-noise ratio of the shaped waveform to 1. Statistical analysis describes how the signal-to-noise ratio is affected by polarization multiplexing and averaging over multiple realizations of the incoherent process. The signal-to-noise ratio of highspeed electric waveforms generated by photodetection of the shaped optical waveform is described.

coherence↗

Application of Spatially Resolved High Resolution Crystal Spectrometry to ICF Plasmas

High resolution (λ/Δ λ ~ 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-μm 55 Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10-8 -10-6 times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗