Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Excellent antioxidizing, thermally insulating and flame resistance silica‐polybenzoxazine aerogels for aircraft ablative materials

Abstract High‐performance thermal protective composites with lightweight, micro‐ ablation and high‐efficient thermal insulation are urgently required for thermal protection systems in advanced hypersonic speed vehicles. However, the practical applications of thermal protective composites have long been hampered by the main issues such as low mass residual rate and poor long‐term antioxidation of the matrix in high‐temperature aerobic environments. Here, we report a novel silica‐polybenz oxazine (SiO 2 ‐PBO) aerogels with interpenetrated networks, possessing the ability to antioxidation, thermal insulation, and flame‐retardant properties. The resulting SiO 2 ‐PBO aerogels exhibit low density (0.25 g/cm 3 ), low thermal conductivity (0.035 W/(m·K)), and superior peak heat release rate value (15.3 W/g). Moreover, the mass residual rate is up to 70.46 wt% in the N 2 atmosphere and remains 57.83 wt% despite existing in the air atmosphere and experiencing the highest temperature of 800°C. Briefly, SiO 2 ‐PBO aerogels as‐prepared could be a potential matrix for a new gene ration of high‐performance thermal protective composites in the future.

Xiao, Yunyun↗

Similarity tests of turbine vanes, effects of ceramic thermal barrier coatings

The role of material thermal conductivity was analyzed for its effect on the thermal performance of air-cooled gas turbine components coated with a ceramic thermal barrier material when tested at reduced temperatures and pressures. It is shown that the thermal performance can be evaluated reliably at reduced gas and coolant conditions; however, thermal conductivity corrections are required for the data at reduced conditions. Corrections for a ceramic thermal barrier coated vane are significantly different than for an uncoated vane. Comparison of uncorrected test data, therefore, would show erroneously that the thermal barrier coating was ineffective. When thermal conductivity corrections are applied to the test data these data are then shown to be representative of engine data and also show that the thermal barrier coating increases the vane cooling effectiveness by 12.5 percent.

Gladden, H. J.↗

Similarity tests of turbine vanes - Effects of ceramic thermal barrier coatings

The role of material thermal conductivity was analyzed for its effect on the thermal performance of air-cooled gas turbine components coated with a ceramic thermal barrier material when tested at reduced temperatures and pressures. This study shows that the thermal performance can be evaluated reliably at reduced gas and coolant conditions. However, thermal conductivity corrections are required for the data at reduced conditions. These corrections for a ceramic thermal barrier coated vane are significantly different than the corrections for an uncoated vane. Comparison of uncorrected test data, therefore, would show erroneously that the thermal barrier coating was ineffective. When thermal conductivity corrections are applied to the test data these data are then shown to be representative of engine data and also show that the thermal barrier coating increases the vane cooling effectiveness by 12.5 precent.

Gladden, H. J.↗

Thermal Analysis of a Solid Particle Light-Trapping Planar Cavity Receiver Using Computational Fluid Dynamics

Concentrated solar power (CSP) is one of the most effective ways of harnessing solar power to create efficient, durable, and resilient energy systems. This study entails thermal modeling and analysis of a novel central tower receiver configuration. This receiver uses solid particles as the heat transfer fluid (HTF), a promising option for third-generation CSP systems. The configuration considered here is the light-trapping planar cavity receiver (LTPCR) introduced by the National Renewable Energy Laboratory. While heat transfer studies of various LTPCR subsystems have been done, system-level thermal analysis of the LTPCR receiver has not been attempted. This study also presents important sensitivity analyses of the operating parameters of the CSP system, which can help guide the design of future central tower receivers. This study employs Ansys Fluent as a computational fluid dynamics (CFD) tool to model fluid dynamics and heat transfer in the receiver, intending to quantify its thermal performance. The model seamlessly integrates Monte Carlo ray tracing data, which generates absorbed solar flux profiles from the heliostat field design, with the heat transfer characteristics of the fluidized particle bed. This unified model is designed to accurately predict the thermal behavior of the LTPCR. Analysis of preliminary results reveals that the primary loss mechanisms are radiative and natural convective losses, in that order. Based on observations from a baseline case, several strategies are suggested and numerically tested. These solutions include selective cooling of high-temperature regions and manipulation of particle bed parameters. Selective cooling of high-temperature regions reduced the peak temperature by 151 degrees C and decreased thermal losses by 0.9%. Improving the particle-wall heat transfer coefficient (P-W HTC) of the particle bed decreased the thermal losses by 1.7% and decreased the peak temperatures by 57 degrees C. Decreasing the particle inlet temperature (PIT) also reduced thermal losses by 3.5% and decreased peak temperatures by 29 degrees C. Compounding these strategies improved the thermal losses of the receiver from 13.5% in the baseline case to 7.5%. Additionally, the study explores the variation in thermal performance across different locations of the receiver, where a variation of thermal losses from 12.9% to 17.3% is found. This allows a comprehensive evaluation of potential improvements in efficiency and temperature management.

computational fluid dynamics↗

System for Testing Thermal Insulation of Pipes

An apparatus and method have been developed for measuring the rates of leakage of heat into pipes carrying liquids, the purpose of the measurements being to quantify the thermal performance of the insulation system. The apparatus is designed primarily for testing pipes used to carry cryogenic liquids, but can also be used for measuring the thermal performance of other insulated pipes or piping systems. The basic measurement principle is straightforward: The outer surface of the pipe insulation is maintained at a fixed warmer temperature. The interior of the pipe is maintained in a narrow fixed lower-temperature range by means of a regular liquid (e.g., water) that is pumped through the pipe at a known flow rate or a cryogenic liquid (e.g., nitrogen) that is saturated at atmospheric pressure and replenished until steady-state conditions are achieved. In the case of water or another liquid pumped through, the inlet and outlet temperatures are measured and heat-leak power is calculated as the mass flow rate of the liquid multiplied by the specific heat of the liquid multiplied by the inlet-to-outlet temperature rise of the liquid. In the case of liquid nitrogen or another low-temperature boiling liquid, the heat-leak power is calculated as the rate of boil-off multiplied by the latent heat of vaporization of the liquid. Then the thermal-insulation performance of the pipe system can be calculated as a function of the measured heat-leak power, the inner and outer boundary temperatures, and the dimensions of the pipe. The apparatus can test as many as three pipes simultaneously. The pipes can have inner diameters up to .15 cm and outer diameters up to .20 cm. The lengths of the pipes may vary; typical lengths are of the order of 18 m. Two thermal guard boxes . one for each end of the pipe(s) under test . are used to make the inlet and outlet fluid connections to the pipe(s) (see figure). The connections include bellows that accommodate thermal expansion and contraction of the pipes. The guard boxes and pipe(s) are positioned so that the pipe(s) slope upward from the upstream to the downstream end at an angle of at least 2 . The upward slope allows vapor bubbles to accumulate at the downstream end. The thermal guard boxes keep the ends of the pipes at the lower interior temperature to prevent spurious lengthwise leakage of heat into the pipes. It is important to prevent this spurious heat leakage because, if it were allowed to occur, it could contribute a large error in the measured heat-leak power. The upstream thermal guard box includes a heat exchanger through which liquid flowing into the pipe(s) is subcooled to the saturation temperature corresponding to the ambient pressure. Conversely, this heat exchanger can also be used to warm the flowing liquid to a desired fixed temperature. The apparatus includes a temperature control device that is placed around each pipe under test. Each device is operated under thermostatic control to maintain the outer surface of the pipe insulation at the specified test temperature. All measurements are recorded on a portable data-acquisition system.

Fesmire, James E.↗

Hybrid Analytics Solution to Improve Coal Power Plant Operations

This project focused on developing advanced methods for thermal performance monitoring of a coal-fueled power plant. The specific goal was to develop and demonstrate a new thermal performance monitoring approach using a hybrid model that integrates a physics-based heat balance model with a machine learning-based pattern recognition model. The hybrid model enables increased accuracy and scope of the thermal analysis and an improved ability to monitor and detect changes in plant operation. This new approach takes full advantage of the individual model capabilities and creates an important new set of capabilities not previously possible using the two types of models separately. Using the heat balance model, a rich set of derived parameters (virtual sensors) are calculated from the measured plant operating data at each time point. The combined measured and derived data values are used by machine learning algorithms to create pattern recognition models over the range of normal unit operation. To create the monitoring models, historical data from normal operation of the plant is first processed by the heat balance model to compute the derived parameter data. The result is a greatly expanded set of normal operating data that can be used as input to create the pattern recognition model. Once the models are calibrated for normal operation, the hybrid model is suitable for use in continuous online monitoring. During online monitoring, new plant operating data is processed first by the heat balance model and then by the pattern recognition model. Results from the pattern recognition model quantify the deviation of each measured or derived parameter from its expected value in normal operation. The hybrid models can detect abnormal changes in plant operating data with very high accuracy and sensitivity. When abnormal behavior is detected, alerts are generated automatically for evaluation by the plant monitoring staff. The new hybrid solution product was developed and verified in the performance of the project. The hybrid solution was tested first in a simulation environment that mimicked the plant data systems and infrastructure used by U.S. power generating plants and utilities. The hybrid solution was then deployed for real-time, online monitoring of an operating coal-fueled power plant at a field test site. Field testing demonstrated that all hybrid solution development objectives were accomplished. The project work was based on combining the capabilities of two existing software products to create the new hybrid solution product. One of these was the existing MapEx® heat balance product and the other was the existing SureSense® advanced pattern recognition product. Each of these separate products was assessed to be at a Technology Readiness Level (TRL) of 9 at the start of the effort. The hybrid solution product was assessed to be at a TRL of 2 at the start of the project based on early feasibility work by the project team. At completion of the field testing performed in the project, the hybrid solution product was assessed to be at a TRL of 7. The project team expects that the hybrid solution product will be deployed commercially and will achieve a TRL of 9 within one year after completion of the project.

01 COAL, LIGNITE, AND PEAT↗

EXPERIMENTAL ANALYSIS OF SINGLE EVAPORATION TUBE UTILIZING SINTERED COPPER PARTICLE WICKING STRUCTURES

Wicking structures have been widely used within passive heat transfer devices with high heat fluxes, such as heat pipes, to enhance their thermal performance. While wicking structures promote capillary pumping of the working fluid as well as thin film evaporation, they can result in capillary evaporation and further enhances the evaporation heat transfer. In this study, a 0.5 mm thick layer of 105 microns sintered copper particles was added to the inner wall of a copper tube, aiming to enhance the heat transfer characteristics by taking advantage of capillary evaporation. Acetone was chosen as the working fluid, and the performance of an evaporation tube was tested for power inputs of 10, 30, 50, and 70 W. For each power input, trials were run at inclination angles varying from -90° and 90° to investigate the capillary effects. The temperature measurements showed that the temperature distribution along the evaporation tube is always downward sloping, meaning the temperature at the fluid inlet is larger than the outlet. Interestingly, the surface temperature at some locations is less than the outlet temperature, indicating the effect of capillary evaporation. In addition, a theoretical investigation was performed to investigate the effects of the particle size on the thermal performance of the evaporation tube and found that particle sizes affect capillary evaporation.

Wang, Pengtao↗

High-heat transfer lithium-ion batteries: A new era in battery thermal management

Despite advances in lithium-ion battery technology, critical challenges remain that must be addressed to accelerate electric vehicle (EV) adoption and global energy transformation. Significantly improved battery thermal management (BTM) is key to overcoming these challenges. BTM approaches focus on increasing heat transfer coefficients via air, liquid, or refrigerant cooling, but less attention is given to reducing the battery's thermal resistance, a major bottleneck for heat transfer. This work introduces a novel approach to reduce battery thermal resistance by integrating in-plane heat transfer with optimized cell geometry, minimized thermal resistances, and reduced interfacial resistances, representing a departure from previous methods. The standard prismatic can cell incorporating this technology is referred to as the high heat transfer (HHT) battery. An equivalent resistance battery thermal model is developed for speed and accuracy, validated against experimental data in the literature, demonstrating strong correlation and ensuring reliable predictions for real-world performance. Thermal performance metrics of the conventional and HHT batteries are compared using a parametric study with air, liquid, and refrigerant boundary conditions across a range of aspect ratios. The HHT battery shows a heat removal rate up to 20 times higher than a conventional battery. These findings suggest that HHT technology could be transformative for EV battery performance, enabling fast charging, mitigating thermal runaway, extending battery life, reducing cold-weather power loss, increasing reliability, lowering costs, and enabling higher energy density, all critical for EV adoption and energy transformation. Future work will focus on prototyping and real-world testing to refine these findings for commercial-scale applications.

25 ENERGY STORAGE↗

The role of moisture in MgCl 2 salt: A multiscale approach to TES performance

This study presents a comprehensive multiscale analysis to evaluate the influence of moisture on the thermal performance of thermal energy storage systems using magnesium chloride (MgCl 2 ) as the phase-changing material. The system uses graphite foam with 90% relative density to enhance thermal conductivity. The analysis includes thermal conductivity calculations and specific heat capacity for different hydrate phases of MgCl 2 : Anhydrous, Mono, Di, Tetra, and Hexa. These properties were evaluated for the first time using the phonon density of states from Density Functional Theory simulations. Results showed that thermal conductivity decreased, while specific heat capacity increased by a factor of two as the phase changed from anhydrous to hexahydrate. Meso-scale models were created to account for the anisotropy of graphite foam and property variations of the MgCl 2 hydrate phases. Asymptotic Expansion homogenization simulations determined the anisotropic thermal conductivity for all phases. This unique methodology improved simulation accuracy, which matched experimental data for anhydrous MgCl 2 . A parametric study examined various operating conditions and their effect on TES performance. It revealed that higher charging temperatures did not enhance exergy efficiency, but increased discharge mass flow rates improved it due to better heat transfer. Thermal performance evaluated by the exergy efficiency remained consistent across hydrate systems under the tested conditions. Furthermore, the study suggests that this uniformity is linked to missing key data, particularly latent heat and melting point for different hydrates. Overall, it highlights the importance of multiscale effects and accurate material properties in designing and optimizing TES systems.

Molten salt degradation↗

Enhancement of conventional concrete mix designs for sensible thermal energy storage applications

The study examines twenty-nine different concrete mix designs with varying constituents to improve thermal performance for energy storage at elevated temperatures up to 420 °C. Effects of variables including the type and volumetric percentage of coarse and fine aggregates, the type and replacement content of supplemental cementitious materials, water-to-cement ratio, the type and quantity of steel fiber reinforcement, and the inclusion of iron oxide powder are experimentally investigated by measuring the mechanical and thermal properties of each mix, with the overall goal of enhancing thermal performance and mitigating mechanical degradation for thermal energy storage (TES) applications. It is found that the use of siliceous aggregate with a high volumetric percentage produces the highest improvement (23 %–37 % at elevated temperatures) of concrete thermal conductivity, while silica fume replacement of Type I cement provides the highest improvement (4 %–8 % at elevated temperatures) of concrete specific heat. To simulate the operation of a TES system, thermal cycling was conducted to examine the change in concrete properties as a function of repetitive heating (during and after 50 total cycles to 420 °C). Based on the results of testing, concrete mix designs with high aggregate percentages (up to 72 % by volume), siliceous coarse aggregate, silica fume replacement of Type I cement (15 % by weight), and steel fiber reinforcement (up to 2 % by volume) facilitate enhanced TES performance by providing consistent thermal conductivity of ~2.2 W/m·K and specific heat of ~3.2 MJ/m 3 ·K under cyclic high temperature exposure.

25 ENERGY STORAGE↗

Optimization of cool roof and night ventilation in office buildings: A case study in Xiamen, China

Increasing roof albedo (using a “cool” roof) and night ventilation are passive cooling technologies that can reduce the cooling loads in buildings, but existing studies have not comprehensively explored the potential benefits of integrating these two technologies. This study combines an experiment in the summer and transition seasons with an annual simulation so as to evaluate the thermal performance, energy savings and thermal comfort improvement that could be obtained by coupling a cool roof with night ventilation. A holistic approach integrating sensitivity analysis and multi-objective optimization is developed to explore key design parameters (roof albedo, night ventilation air change rate, roof insulation level and internal thermal mass level) and optimal design options for the combined application of the cool roof and night ventilation. The proposed approach is validated and demonstrated through studies on a six-storey office building in Xiamen, a cooling-dominated city in southeast China. Simulations show that combining a cool roof with night ventilation can significantly decrease the annual cooling energy consumption by 27% compared to using a black roof without night ventilation and by 13% compared to using a cool roof without night ventilation. Roof albedo is the most influential parameter for both building energy performance and indoor thermal comfort. Optimal use of the cool roof and night ventilation can reduce the annual cooling energy use by 28% during occupied hours when air-conditioners are on and reduce the uncomfortable time slightly during occupied hours when air-conditioners are off.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Analysis of a 100 kW Polyphase Wireless Power Transfer System

Charging Electric Vehicles (EVs) fast and safely has a crucial role in the future of the EV technology. High-power Wireless Power Transfer (WPT) helps to significantly decrease the charging time. However, when the power transfer levels increase, thermal management becomes a significant challenge. The thermal design of the WPT systems needs more consideration in the design and implementation steps. This paper presents a thermal analysis of a 100 kW high-power WPT system. The thermal performance of the proposed design was evaluated at different power levels by considering the magnetic design and loss analysis. Finite Element Analysis (FEA) of the proposed design was performed and the thermal images of the implemented system were taken to prove the simulation results. The results show that, a liquid cooling design is needed for a high-power WPT systems for the long-time continuous operations of the charging pads.

Aydin, Emrullah↗

Prototype Development, Testing, and Modeling for a Solar Light-Trapping Planar-Cavity Particle Receiver (LTPCR)

Many applications for concentrating solar thermal power (CSP) technologies of high efficiency power cycles or thermochemical processes require higher operating temperatures and alternative heat transfer media. Inert solid particles for next-generation CSP and reactive gas and/or solid media for solar thermochemical processes are common options; however, these have significantly lower heat transfer capabilities than thermal oil, molten salt, or molten metal media. Conventional solar receivers operating temperatures >700 degrees Celsius face challenges including thermal performance and thermal-mechanical issues. To overcome these limitations, we have developed a novel light-trapping, planar-cavity receiver (LTPCR) that can heat solid-phase media within an enclosed receiver while maintaining a high aperture solar flux concentration for high efficiency. This paper presents progress on design, fabrication, and testing of a 100 kWt prototype receiver to demonstrate the LTPCR operability and its commercial feasibility.

14 SOLAR ENERGY↗

Stress Intensity of Delamination in a Sintered-Silver Interconnection: Preprint

In automotive power electronics packages, conventional thermal interface materials such as greases, gels, and phase-change materials pose bottlenecks to heat removal and are also associated with reliability concerns. The industry trend is toward high thermal performance bonded interfaces for large-area attachments. However, because of coefficient of thermal expansion mismatches between materials/layers and resultant thermomechanical stresses, adhesive and cohesive fractures could occur, posing a reliability problem. These defects manifest themselves in increased thermal resistance. This research aims to investigate and improve the thermal performance and reliability of sintered-silver for power electronics packaging applications. This has been experimentally accomplished by the synthesis of large-area bonded interfaces between metalized substrates and copper base plates that have subsequently been subjected to thermal cycles. A finite element model of crack initiation and propagation in these bonded interfaces will allow for the interpretation of degradation rates by a crack-velocity (V)-stress intensity factor (K) analysis. A description of the experiment and the modeling approach are discussed.

30 DIRECT ENERGY CONVERSION↗

Sleeper Cab Climate Control Load Reduction for Long-Haul Truck Rest Period Idling

Annual fuel use for long-haul truck rest period idling is estimated at 667 million gallons in the United States. The U.S. Department of Energy’s National Renewable Energy Laboratory’s CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck climate control systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In order for candidate idle reduction technologies to be implemented at the original equipment manufacturer and fleet level, their effectiveness must be quantified. To address this need, a number of promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. For this study, load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, and conductive pathways. The technologies selected for a complete-cab package of technologies were “ultra-white” paint, advanced insulation, and advanced curtains. To measure the impact of these technologies, a nationally-averaged solar-weighted reflectivity long-haul truck paint color was determined and applied to the baseline test vehicle. Using the complete-cab package of technologies, electrical energy consumption for long-haul truck daytime rest period air conditioning was reduced by at least 35% for summer weather conditions in Colorado. The National Renewable Energy Laboratory's CoolCalc model was then used to extrapolate the performance of the thermal load reduction technologies nationally for 161 major U.S. cities using typical weather conditions for each location over an entire year.

33 ADVANCED PROPULSION SYSTEMS↗

Prototype Development, Testing, and Modeling for a Solar Light-Trapping Planar-Cavity Particle Receiver

Many applications for concentrating solar thermal power (CSP) technologies of high efficiency power cycles or thermochemical processes require higher operating temperatures and alternative heat transfer media. Inert solid particles for next-generation CSP and reactive gas and/or solid media for solar thermochemical processes are common options; however, these have significantly lower heat transfer capabilities than thermal oil, molten salt, or molten metal media. Conventional solar receivers operating temperatures >700 degrees Celsius face challenges including thermal performance and thermal-mechanical issues. To overcome these limitations, we have developed a novel light-trapping, planar-cavity receiver (LTPCR) that can heat solid-phase media within an enclosed receiver while maintaining a high aperture solar flux concentration for high efficiency. This paper presents progress on design, fabrication, and testing of a 100 kWt prototype receiver to demonstrate the LTPCR operability and its commercial feasibility.

14 SOLAR ENERGY↗

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE↗