Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

All Different Flavors of Synchrotron Single Crystal X-Ray Diffraction Experiments

This lecture reviews the main concepts, applications and capabilities of different non-conventional approaches to single-crystal x-ray diffraction (SXD) experiment utilizing synchrotron radiation for applications in high-pressure research. You will learn how such experiment can be designed and performed to best answer the scientific goals of your study and, at the same time overcome the main technical limitations imposed by the high-pressure device and type of measurement. The emphasis will be placed on experiments that cannot be performed using laboratory instruments, e.g. involving ultrahigh (>50 GPa) pressures, poor quality samples, laser heating in diamond anvil cell (DAC), etc. The main goal of the presentation is to convince you that even if you are not an expert crystallographer, with good understanding of the general basic principles of synchrotron SXD experiments in a DAC you can successfully use these techniques as valuable and easy tools in your own high-pressure research.

58 GEOSCIENCES↗

Beam studies at the SPEAR3 synchrotron using a digital optical mask

The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500 mA circulating in the storage ring (equivalently 392 nC). Each injection pulse contains 40–80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during user operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by imaging the visible component of the synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera, makes it possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, a high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron Radiation for Biomedical Imaging

A synchrotron radiation (SR) X-ray source is an extraordinary tool for many applications because of the high intensity, the energy spectrum properties, the peculiar laminar beam geometry and the high degree of coherence. In the past years several experimental studies have proven the suitability of SR in the field of biomedical X-ray imaging and in diagnostic radiography. SR based X-ray imaging techniques to be mentioned are transvenous coronary angiography, bronchography, computed tomography and mammography that have been successfully implemented at different SR laboratories all around the world. Moreover, the high degree of the coherence of the synchrotron source allows the implementation of novel phase-sensitive X-ray imaging modalities. In contrast to conventional X-ray radiography, based on different X-ray absorption properties of details within an object, these phase-based techniques are capable of visualizing structures that have different scattering and refraction properties respect to the surrounding material. Their importance in medical imaging lies in the fact that the diagnosis of several diseases requires the detection of tiny structures, that consist of light elements in a similar background, and that produce very low X-ray absorption, but considerable phase shift in the wave front propagation. Thus, phase-sensitive techniques may improve dramatically the image quality and subsequently the accuracy in diagnosis offering highly enhanced contrast with dose comparable or even lower than required by conventional radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Failure of Thin Ta and Cu/Ta Layers on Polyimide Substrates: A Synchrotron-Based Technique for In Situ Characterization

In situ synchrotron radiation diffraction and confocal light microscopy is used to study fragmentation and buckling of thin brittle Ta layers with thicknesses of 50 nm, 100 nm and 200 nm on polyimide substrates. Synchrotron-based stress measurements confirm that cracking leads to relaxation of tensile stress. Simultaneously, compressive stress arises in transverse direction, which finally leads to buckling. This behavior can be explained quantitatively by a two-dimensional shear lag model. It is well established that the properties of the coating-substrate interface determine the processes of coating fragmentation and delamination. A possible approach for influencing and controlling these processes is given by the incorporation of a ductile interlayer. It can be observed that the presence of Cu interlayers with thicknesses of 5 nm, 20 nm and 50 nm reduces the fracture strength of brittle Ta coatings on polyimide substrates, whereas the resistance to buckling is increased significantly.

36 MATERIALS SCIENCE↗

Techniques for Handling and Removal of Spectral Channels in Fourier Transform Synchrotron-Based Spectra

Channel spectra are a big problem for those attempting to use synchrotron-based Fourier transform spectra for spectral lineshape studies. Due to the layout of the optical system at the CLS far-infrared beamline, the synchrotron beam undergoes unavoidable multiple reflections on the steering mirrors, beam splitter, several sets of windows, and filters. We present a method for eliminating channel spectra and compare the results of our technique with other methods available in the literature.

43 PARTICLE ACCELERATORS↗

Nanopositioning techniques development for synchrotron radiation instrumentation applications at the Advanced Photon Source

At modern synchrotron radiation sources and beamlines, high-precision positioning techniques present a significant opportunity to support state-of-the-art synchrotron radiation research. Meanwhile, the required instrument positioning performance and capabilities, such as resolution, dynamic range, repeatability, speed, and multiple axes synchronization are exceeding the limit of commercial availability. This paper presents the current nanopositioning techniques developed for the Argonne Center for Nanoscale Materials (CNM)/Advanced Photon Source (APS) hard x-ray nanoprobe and high-resolution x-ray monochromators and analyzers for the APS X-ray Operations and Research (XOR) beamlines. Future nanopositioning techniques to be developed for the APS renewal project will also be discussed.

43 PARTICLE ACCELERATORS↗

Central Japan Synchrotron Radiation Research Facility Project-(II)

A synchrotron radiation facility that is used not only for basic research, but also for engineering and industrial research and development has been proposed to be constructed in the Central area of Japan. The key equipment of this facility is a compact electron storage ring that is able to supply hard X-rays. The circumference of the storage ring is 72 m with the energy of 1.2 GeV, the beam current of 300 mA, and the natural emittance of about 53 nm-rad. The configuration of the storage ring is based on four triple bend cells, and four of the twelve bending magnets are 5 T superconducting ones. The bending angle and critical energy are 12 degree and 4.8 keV, respectively. For the top-up operation, the electron beam will be injected from a booster synchrotron with the full energy. Currently, six beamlines are planned for the first phase starting from 2012.

43 PARTICLE ACCELERATORS↗

Performance of Multilayer Monochromators for Hard X-Ray Imaging with Coherent Synchrotron Radiation

We present a study in which multilayers of different periodicity (from 2.5 to 5.5 nm), composition (W/Si, Mo/Si, Pd/B{sub 4}C, Ru/B{sub 4}C), and numbers of layers have been compared. Particularly, we chose mirrors with similar intrinsic quality (roughness and reflectivity) to study their performance (flatness and coherence of the outgoing beam) as monochromators in synchrotron radiography. The results indicate that material composition is the dominating factor for the performance. This is important to consider for future developments in synchrotron-based hard x-ray imaging methods. In these techniques, multilayer monochromators are popular because of their good tradeoff between spectral bandwidth and photon flux density of the outgoing beam, but sufficient homogeneity and preservation of the coherent properties of the reflected beam are major concerns. The experimental results we collected may help scientists and engineers specify multilayer monochromators and can contribute to better exploitation of the advantages of multilayer monochromators in microtomography and other full-field imaging techniques.

43 PARTICLE ACCELERATORS↗

A new highly automated sputter equipment for in situ investigation of deposition processes with synchrotron radiation

HASE (Highly Automated Sputter Equipment) is a new mobile setup developed to investigate deposition processes with synchrotron radiation. HASE is based on an ultra-high vacuum sputter deposition chamber equipped with an in-vacuum sample pick-and-place robot. This enables a fast and reliable sample change without breaking the vacuum conditions and helps to save valuable measurement time, which is required for experiments at synchrotron sources like PETRA III at DESY. An advantageous arrangement of several sputter guns, mounted on a rotative flange, gives the possibility to sputter under different deposition angles or to sputter different materials on the same substrate. The chamber is also equipped with a modular sample stage, which allows for the integration of different sample environments, such as a sample heating and cooling device. The design of HASE is unique in the flexibility. The combination of several different sputtering methods like standard deposition, glancing angle deposition, and high pressure sputter deposition combined with heating and cooling possibil-ities of the sample, the large exit windows, and the degree of automation facilitate many different grazing incidence X-ray scattering experiments, such as grazing incidence small and wide angle X-ray scattering, in one setup. In this paper we describe in detail the design and the performance of the new equipment and present the installation of the HASE apparatus at the Micro and Nano focus X-ray Scattering beamline (MiNaXS) at PETRA III. Furthermore, we describe the measurement options and present some selected results. The HASE setup has been successfully commissioned and is now available for users.

43 PARTICLE ACCELERATORS↗

Fast synchrotron X-ray tomography study of the rod packing structures

We present a fast synchrotron X-ray tomography study of the packing structures of rods under tapping. Utilizing the high flux of the X-rays generated from the third-generation synchrotron source, we can complete a tomography scan within several seconds, after which the three-dimensional (3D) packing structure can be obtained for the subsequent structural analysis. Due to the high-energy nature of the X-ray beam, special image processing steps including image phase-retrieval has been implemented. Overall, this study suggests the possibility of acquiring statistically significant static packing structures within a reasonable time scale using high-intensity X-ray sources.

36 MATERIALS SCIENCE↗

Design of a low-emittance lattice for 3.5 GeV synchrotron light source

We investigate a lattice design for a low-emittance, high-brilliance intermediate energy synchrotron light source that is being intensively performed in the world. We present the design results in detail for a non-achromatic double bend achromat lattice with an emittance of 1.1 nm and 597.6 m circumference. Each superperiod has 4 straight sections, 7 m, 5.4 m, and 2 × 2.8 m in length, giving a total of 60 straight sections in the ring. The lattice is designed to be flexible and also provides an achromatic optics with an emittance of 3.2 nm. The lattice provides high brilliance at a photon energy of a few tens of keV, which meets the requirements of hard X-ray synchrotron radiation users. We investigated the dynamic aperture in the lattice with machine errors using a simulation method that achieves the optimal tune for the ring. The low-emittance lattice provides sufficient dynamic aperture after closed orbit distortion correction. We show an estimate of variations of emittance, energy spread, and dynamic aperture due to a wiggler in the straight sections. We present the design of an injection scheme for full energy injection, the space allocation in injection section, and the particle dynamics of injected beam. Particle tracking after beam injection was performed to examine the validity of the injection scheme. Our design lattice shows good optimization in terms of the emittance, number of straight sections, brilliance, and circumference as a light source for 3.5 GeV beam energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron radiation, pair production, and longitudinal electron motion during 10-100 PW laser solid interactions

At laser intensities above 10{sup 23} W/cm{sup 2}, the interaction of a laser with a plasma is qualitatively different to the interactions at lower intensities. In this intensity regime, solid targets start to become relativistically underdense, gamma-ray production by synchrotron emission starts to become an important feature of the dynamics and, at even higher intensities, electron-positron pair production by the non-linear Breit-Wheeler process starts to occur. In this paper, an analysis is presented of the effects of target density, laser intensity, target preplasma properties, and other parameters on the conversion efficiency, spectrum, and angular distribution of gamma-rays by synchrotron emission. An analysis of the importance of Breit-Wheeler pair production is also presented. Target electron densities between 10{sup 22} cm{sup −3} and 5 × 10{sup 24} cm{sup −3} and laser intensities covering the range between 10{sup 21} W/cm{sup 2} (available with current generation laser facilities) and 10{sup 24} W/cm{sup 2} (upper intensity range expected from the ELI facility are considered. Results are explained in terms of the behaviour of the head of the laser pulse as it interacts with the target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Repeatability and reproducibility of intracellular molar concentration assessed by synchrotron-based x-ray fluorescence microscopy

Elemental analysis of biological sample can give information about content and distribution of elements essential for human life or trace elements whose absence is the cause of abnormal biological function or development. However, biological systems contain an ensemble of cells with heterogeneous chemistry and elemental content; therefore, accurate characterization of samples with high cellular heterogeneity may only be achieved by analyzing single cells. Powerful methods in molecular biology are abundant, among them X-Ray microscopy based on synchrotron light source has gaining increasing attention thanks to its extremely sensitivity. However, reproducibility and repeatability of these measurements is one of the major obstacles in achieving a statistical significance in single cells population analysis. In this study, we compared the elemental content of human colon adenocarcinoma cells obtained by three distinct accesses to synchrotron radiation light.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Novel portable press for synchrotron time-resolved 3-D micro-imagining under extreme conditions

Here we present the instrumental development to extend the synchrotron X-ray microtomography techniques to in situ studies under static compression (HP) or shear stress or the both conditions at high temperatures (HT). To achieve this, a new rotating tomography Paris-Edinburgh cell (rotoPEc) has been developed. This ultra-compact portable device, easily and successfully adapted to various multi-modal synchrotron experimental set-up at ESRF, SOLEIL and DIAMOND is explained in detail.

43 PARTICLE ACCELERATORS↗

MAXIMUM BRIGHTNESS TEMPERATURE OF AN INCOHERENT SYNCHROTRON SOURCE: INVERSE COMPTON LIMIT-A MISNOMER

We show that an upper limit of {approx}10{sup 12} K on the peak brightness temperature for an incoherent synchrotron radio source, commonly referred to in the literature as an inverse Compton limit, really may not be due to inverse Compton effects. We show that a somewhat tighter limit T{sub eq} {approx} 10{sup 11} is actually obtained for the condition of equipartition of energy between radiating particles and magnetic fields, which happens to be a configuration of minimum energy for a self-absorbed synchrotron radio source. An order of magnitude change in brightness temperature from T{sub eq} in either direction would require departures from equipartition of about 8 orders of magnitude, implying a change in total energy of the system up to {approx}10{sup 4} times the equipartition value. Constraints of such extreme energy variations imply that brightness temperatures may not depart much from T{sub eq}. This is supported by the fact that at the spectral turnover, brightness temperatures much lower than {approx}10{sup 11} K are also not seen in VLBI observations. Higher brightness temperatures in particular would require in the source not only many orders of magnitude higher additional energy for the relativistic particles but also many orders of magnitude weaker magnetic fields. Diamagnetic effects do not allow such extreme conditions, keeping the brightness temperatures close to the equipartition value, which is well below the limit where inverse Compton effects become important.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarized mid-infrared synchrotron emission in the core of Cygnus A

We present high-angular (∼0.''4) resolution mid-infrared (MIR) polarimetric observations in the 8.7 μm and 11.6 μm filters of Cygnus A using CanariCam on the 10.4 m Gran Telescopio CANARIAS. A highly polarized nucleus is observed with a degree of polarization of 11% ± 3% and 12% ± 3% and a position angle of polarization of 27° ± 8° and 35° ± 8° in a 0.''38 (∼380 pc) aperture for each filter. The observed rising of the polarized flux density with increasing wavelength is consistent with synchrotron radiation from the parsec-scale jet close to the core of Cygnus A. Based on our polarization model, the synchrotron emission from the parsec-scale jet is estimated to be 14% and 17% of the total flux density in the 8.7 μm and 11.6 μm filters, respectively. A blackbody component with a characteristic temperature of 220 K accounts for >75% of the observed MIR total flux density. The blackbody emission arises from a combination of (1) dust emission in the torus; and (2) diffuse dust emission around the nuclear region, but the contributions of the two components cannot be well-constrained in these observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron radiation based beam diagnostics at the Fermilab Tevatron

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. Therefore, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transverse beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measurements from the profile monitor to measurements from the flying wire profile systems are presented as are a number of examples of the application of the profile and abort gap intensity measurements to the modelling of Tevatron beam dynamics.

43 PARTICLE ACCELERATORS↗