Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “suspensions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Acute and chronic head-down tail suspension diminishes cerebral perfusion in rats

The purpose of this study was to test the hypothesis that regional brain blood flow and vascular resistance are altered by acute and chronic head-down tail suspension (HDT). Regional cerebral blood flow, arterial pressure, heart rate, and vascular resistance were measured in a group of control rats during normal standing and following 10 min of HDT and in two other groups of rats after 7 and 28 days of HDT. Heart rate was not different among conditions, whereas mean arterial pressure was elevated at 10 min of HDT relative to the other conditions. Total brain blood flow was reduced from that during standing by 48, 24, and 27% following 10 min and 7 and 28 days of HDT, respectively. Regional blood flows to all cerebral tissues and the eyes were reduced with 10 min of HDT and remained lower in the eye, olfactory bulbs, left and right cerebrum, thalamic region, and the midbrain with 7 and 28 days of HDT. Total brain vascular resistance was 116, 44, and 38% greater following 10 min and 7 and 28 days of HDT, respectively, relative to that during control standing. Vascular resistance was elevated in all cerebral regions with 10 min of HDT and remained higher than control levels in most brain regions. These results demonstrate that HDT results in chronic elevations in total and regional cerebral vascular resistance, and this may be the underlying stimulus for the HDT-induced smooth muscle hypertrophy of cerebral resistance arteries.

Non-NASA Center↗

Review of spaceflight and hindlimb suspension unloading induced sarcomere damage and repair

Hindlimb suspension unloading (HSU) and spaceflight microgravity induce atrophy of the slow adductor longus muscle fibers which, following reloading, exhibit eccentric contraction (EC)-like lesions (abnormal widening of sarcomeres with A band disruption and excessively wavy, extracted Z lines). These lesions are similar morphologically to those produced in normal muscles after strenuous eccentric exercise. It appears that atrophic muscles exhibit increased susceptibility to eccentric damage because lesions are produced during nonstressful voluntary movements upon return to weightbearing. The EC-like lesions are absent in the unweighted conditions, but appear in HSU rats 15-60 minutes after reloading and in space-flown rates about 4 hrs after landing. By 12 hours, many EC-like lesioned sarcomeres are fully covered by longitudinal patches of Z line-like material which increases in density by 48 hours, producing the so-called "Z line streaming" morphology. In this case, Z line streaming is indicative of rapid repair of damaged sarcomeres rather than the onset of sarcomere breakdown. Immunoelectron microscopy is necessary to determine the composition of this dense material. By 9 days of reloading at 1 gravity, sarcomeres have regained normal structure, except for very rare persistence of faint Z patches. The morphological data indicate that Z patches serve at least two functions: 1) to permit contractile force to be transmitted across the damaged sarcomeres and 2) to provide a scaffold upon which sarcomeres are reconstructed in an active functional muscle.

NASA Discipline Number 00-00↗

Hormonal and metabolic responses of hypophysectomized rats with head-down suspension

The primary purpose of this investigation was to secure select anatomical and physiological measurements from hypophysectomized rats and their sham-operated control to determine how various endocrine influences could be modified by conditions of simulated microgravity. The focal point of the study was the exercise responses after head-down suspension; however, we were also interested in obtaining insights on nonexercise-related mechanisms. Since more details and information concerning this study will be published elsewhere, we will highlight those findings which warrant further research.

NASA Program Space Physiology and Countermeasures↗

Effect of oral calcium and calcium + fluoride treatments on mouse bone properties during suspension

The bone effects of oral dosages of calcium chloride with or without supplementary sodium fluoride were assessed in antiorthostatically suspended mice. Two calcium dosages were used to replace half (3.1 mM) or all(6.3 mM) of the dietary calcium lost due to reduced food intake by the suspended mice. Two groups of 6.3 mM CaCl2-treated mice were additionally treated with 0.25 or 2.5 mM NaF. The results indicate that supplementation of the mouse drinking water with calcium salts prevents bone changes induced by short-term suspension, while calcium salts in combination with fluoride are less effective as fluoride dosage increases. However, the calcium supplements change the relationship between the femur mechanical properties and the mineral composition of the bone. Because of this, it appears that oral calcium supplements are effective through a mechanism other than simple dietary supplementation and may indicate a dependence of bone consistency on systemic and local fluid conditions.

Non-NASA Center↗

Experimental Robust Control Studies on an Unstable Magnetic Suspension System

This study is an experimental investigation of the robustness of various controllers designed for the Large Angle Magnetic Suspension Test Fixture (LAMSTF). Both analytical and identified nominal models are used for designing controllers along with two different types of uncertainty models. Robustness refers to maintain- ing tracking performance under analytical model errors and dynamically induced eddy currents, while external disturbances are not considered. Results show that incorporating robustness into analytical models gives significantly better results. However, incorporating incorrect uncertainty models may lead to poorer performance than not designing for robustness at all. Designing controllers based on accurate identified models gave the best performance. In fact, incorporating a significant level of robustness into an accurate nominal model resulted in reduced performance. This paper discusses an assortment of experimental results in a consistent manner using robust control theory.

Lim, Kyong B.↗

Hindlimb suspension diminishes femoral cross-sectional growth in the rat

Growth, functional adaptation, and torsional strength were examined in the femora of 39-day-old male Sprague-Dawley rats subjected to hindlimb suspension for 0, 1, 2, 3, or 4 weeks and were compared with measurements for age-matched control animals. Our goal was to understand the effect of reduced loading on the normal age-related changes in femoral properties during growth. The control animals exhibited growth-related increases in all geometric and torsional properties of the femur. The mean body mass and femoral length of the hindlimb-suspended rats were similar to those of the controls throughout the experiment. Over 4 weeks, the femoral cross-sectional and torsional measurements from the hindlimb-suspended rats demonstrated increases in comparison with the basal values (+33% cross-sectional area, +64% polar moment of inertia, +67% ultimate torque, and +181% torsional rigidity), but the age-matched controls showed significantly greater growth-related increases (+71% cross-sectional area, +136% polar moment of inertia, +127% ultimate torque, and +367% torsional rigidity). The differences in femoral structural strength between the hindlimb-suspended animals and the age-matched controls were attributable to differences in altered cross-sectional geometry.

NASA Discipline Musculoskeletal↗

Metabolic responses to head-down suspension in hypophysectomized rats

Rats exposed to head-down suspension (HDS) exhibit reductions in maximal O2 consumption (VO2max) and atrophy of select hindlimb muscles. This study tested the hypothesis that an endocrine-deficient rat exposed to HDS would not exhibit reductions in VO2max or hindlimb muscle mass. Hypophysectomized (HYPX) and sham-operated (SHAM) rats were tested for VO2max before and after 28 days of HDS or cage control (CC) conditions. No significant reductions in VO2max were observed in HYPX rats. In contrast, SHAM-HDS rats exhibited a significant reduction in absolute (-16%) and relative (-29%) measures of aerobic capacity. Time course experiments revealed a reduction in VO2max in SHAM-HDS rats within 7 days, suggesting that cardiovascular adjustments to HDS occurred in the 1st wk. HDS was associated with atrophy of the soleus (-42%) in SHAM rats, whereas HYPX rats exhibited atrophy of the soleus (-36%) and plantaris (-13%). SHAM-HDS rats had significantly lower (-38%) soleus citrate synthase activities per gram muscle mass than SHAM-CC, but no significant differences existed between HYPX-HDS and -CC rats. HDS rats had an impaired ability to thermoregulate, as indicated by significantly greater temperature increases per unit run time, compared with their CC counterparts. Pretreatment plasma epinephrine levels were significantly lower in HYPX than in SHAM rats. Norepinephrine concentration was similar for all groups except HYPX-HDS, in which it was significantly higher. HDS had no significant effect on thyroxine or triiodothyronine. SHAM-HDS rats had significantly lower concentrations of testosterone and growth hormone.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Number 14-10↗

Magnetic Suspension Being Developed for Future Lube-Free Turbomachinery Application

The NASA Glenn Research Center, the U.S. Army, Texas A&M University, and other industrial partners are continuing to work together to develop magnetic suspension technology to withstand the harsh environmental conditions inside current and future turbomachinery. In fiscal year 2002, our third-generation radial magnetic bearing successfully controlled rotor motion while at 1000 F (540 C) and 20 000 rpm. The ability to command the rotor s position while spinning at this speed was also demonstrated. Future work is planned to include radial bearing tests to 1100 F (593 C) and 30 000 rpm. In fiscal year 2003, we plan to test a high-temperature thrust bearing.

Provenza, Andrew J.↗

The Effect of Suspension-Line Length on Viking Parachute Inflation Loads

Analytical calculations have considered the effect on maximum load of increasing the suspension-line length on the Viking parachute. Results indicate that unfurling time is increased to 1.85 seconds from 1.45 seconds, and that maximum loads are increased approximately 5 percent with an uncertainty of -4 percent to +3 percent.

Talay, Theodore A.↗

Effects Of Suspension-Line Damping On LADT #3 And Supersonic BLDT Parachute Inflation Dynamics

A two-body computerized mathematical model is used to calculate planar dynamics of the LADT #3 and supersonic BLDT parachute inflations. Results indicate that the calculated loads and motions of the LADT #3 inflation are not affected appreciably by variation in the suspension-line damping coefficient. However, variation of the coefficient results in significant changes in the calculated loads and strain rates of the supersonic BLDT inflation.

Poole, Lamont R.↗

Detecting Phase Boundaries in Hard-Sphere Suspensions

A special image-data-processing technique has been developed for use in experiments that involve observation, via optical microscopes equipped with electronic cameras, of moving boundaries between the colloidal-solid and colloidal-liquid phases of colloidal suspensions of monodisperse hard spheres. During an experiment, it is necessary to adjust the position of a microscope to keep the phase boundary within view. A boundary typically moves at a speed of the order of microns per hour. Because an experiment can last days or even weeks, it is impractical to require human intervention to keep the phase boundary in view. The present image-data-processing technique yields results within a computation time short enough to enable generation of automated-microscope-positioning commands to track the moving phase boundary

McDowell, Mark↗

Dispersion of Sound in Dilute Suspensions with Nonlinear Particle Relaxation

The theory accounting for nonlinear particle relaxation (viscous and thermal) has been applied to the prediction of dispersion of sound in dilute suspensions. The results suggest that significant deviations exist for sound dispersion between the linear and nonlinear theories at large values of Omega(Tau)(sub d), where Omega is the circular frequency, and Tau(sub d) is the Stokesian particle relaxation time. It is revealed that the nonlinear effect on the dispersion coefficient due to viscous contribution is larger relative to that of thermal conduction

Kandula, Max↗

A New Method for Interfacing Unsuited Subjects to Overhead Suspension Partial Gravity Simulators

The purpose of performing unsuited testing as part of a reduced gravity extravehicular (EVA) suited human performance research program is to define baseline performance. These results are then coupled with suited test results to evaluate how the suit system affects human performance at reduced gravity. The primary drawback to this approach is that previous studies used notably different systems to interface suited and unsuited subjects to overhead-suspension, partial-gravity simulators. A spreader bar (SB) assembly previously used for unsuited tests allowed limited pitch and roll of the subject, whereas the gimbal for suited tests allowed more pitch and roll, although the mass distribution led to large moments of inertia in the yaw axis. It is hypothesized that use of the same methods for offload of both unsuited and suited subjects is needed to make meaningful comparisons. A new gimbal (GIM) was designed with the idea that it could function with both suited and unsuited subjects. GIM was designed to minimize mass and moments of inertia and to be adjustable to co-locate the 3 axes of rotation with the subject s center of gravity. OBJECTIVE: To evaluate human performance differences between SB and GIM. METHODS: Ten unsuited subjects were off-loaded to 1/6-g using both interfaces. Subjects completed tasks including overground and treadmill ambulation, picking up objects, shoveling, postural stability, range of motion testing, and recovery from the kneeling and prone positions. Metabolic, biomechanical, and/or subjective data were collected based on task. RESULTS: Initial analyses suggest that subjects completed all tasks with lower levels of compensation and a more terrestrial approach to movement when suspended via GIM. With SB, subjects were not able to fall or get into a prone position and had increased difficulty both retrieving objects off the floor and with overground ambulation, especially at gait initiation, because they were unable to bend their torso. GIM shows promise as a new method.

Norcross, Jason R.↗

A New Method for Interfacing Unsuited Subjects to Overhead Suspension Partial Gravity Simulators

The purpose of performing unsuited testing as part of a reduced gravity extravehicular (EVA) suited human performance research program is to define baseline performance. These results are then coupled with suited test results to evaluate how the suit system affects human performance at reduced gravity. The primary drawback to this approach is that previous studies used notably different systems to interface suited and unsuited subjects to overhead-suspension, partial-gravity simulators. A spreader bar (SB) assembly previously used for unsuited tests allowed limited pitch and roll of the subject, whereas the gimbal for suited tests allowed more pitch and roll, although the mass distribution led to large moments of inertia in the yaw axis. It is hypothesized that use of the same methods for offload of both unsuited and suited subjects is needed to make meaningful comparisons. A new gimbal (GIM) was designed with the idea that it could function with both suited and unsuited subjects. GIM was designed to minimize mass and moments of inertia and to be adjustable to co-locate the 3 axes of rotation with the subject s center of gravity. OBJECTIVE: To evaluate human performance differences between SB and GIM. METHODS: Ten unsuited subjects were offloaded to 1/6-g using both interfaces. Subjects completed tasks including overground and treadmill ambulation, picking up objects, shoveling, postural stability, range of motion testing, and recovery from the kneeling and prone positions. Metabolic, biomechanical, and/or subjective data were collected based on task. RESULTS: Initial analyses suggest that subjects completed all tasks with lower levels of compensation and a more terrestrial approach to movement when suspended via GIM. With SB, subjects were not able to fall or get into a prone position and had increased difficulty both retrieving objects off the floor and with overground ambulation, especially at gait initiation, because they were unable to bend their torso. GIM shows promise as a new method.

Norcross, Jason↗

Nutrition Coupled with High-Load Traditional or Low-Load Blood Flow Restricted Exercise During Human Limb Suspension

High-load resistance exercise (HRE) and low-load blood flow restricted (BFR) exercise have demonstrated efficacy for attenuating unloading related muscle atrophy and dysfunction. In recreational exercisers, protein consumption immediately before and/or after exercise has been shown to increase the skeletal muscle anabolic response to resistance training. PURPOSE: To compare the skeletal muscle adaptations when chocolate milk intake was coupled with HRE or low-load BFR exercise [3 d/wk] during simulated lower limb weightlessness. METHODS: Eleven subjects were counterbalanced [based on age and gender] to HRE (31 +/- 14 yr, 170 +/- 13 cm, 71 +/- 18 kg, 2M/3W) or low-load BFR exercise (31 +/- 12 yr, 169 +/- 13 cm, 66 +/- 14 kg, 2M/4W) during 30 days of unilateral lower limb suspension (ULLS). Both HRE and BFR completed 3 sets of single leg press and calf raise exercise during ULLS. BFR exercise intensity was 20% of repetition maximum (1RM) with a cuff inflation pressure of 1.3 systolic blood pressure (143 4 mmHg). Cuff pressure was maintained during all 3 sets including rest intervals (90s). HRE intensity was 75% 1RM and was performed without cuff inflation. Immediately (<10 min) before and after exercise 8 fl oz of chocolate milk (150 kcal, 2.5g total fat, 22g total carbohydrate, 8g protein) was consumed to optimize acute exercise responses in favor of muscle anabolism. ULLS analog compliance was assessed from leg skin temperature recordings and plantar accelerometry. Muscle cross-sectional area (CSA) for knee extensor and plantar flexor muscle groups were determined from analysis of magnetic resonance images using ImageJ software. 1RM strength for leg press and calf raise was assessed on the Agaton exercise system. Muscular endurance during leg press and calf raise was evaluated from the maximal number of repetitions performed to volitional fatigue using 40% of pre-ULLS 1RM. RESULTS: Steps detected by plantar acceleometry declined by 98.9% during ULLS relative to an ambulatory control period. Average skin temperature of the unloaded calf declined from 27.4 C to 26.8 C (-2.1%), while there was a slight increase (+1.1%) in skin temperature in the loaded calf (27.6 C to 27.9 C). Collectively, these measures indicate strong subject compliance with the ULLS analog. Unloaded limb work performed during leg press (1514 +/- 334 vs. 576 +/- 103) and calf raise (2886 +/- 508 vs. 1233 +/- 153) exercises sessions was greater in HRE vs. BFR, respectively. Leg press training loads were 44 +/- 7 kg in HRE compared to 11 +/- 1 kg in BFR. Similarly, calf raise training loads were 81 +/- 11 kg in HRE and 16 +/- 1 kg in BFR. Pre to post-ULLS training adaptations in the unloaded leg are shown in the table. CONCLUSION: The preliminary results of this investigation suggest when HRE is optimized for muscle anabolism during unloading muscle size and strength are preserved (or enhanced) at the expense of muscle endurance. In contrast, when BFR exercise is optimized for muscle anabolism during unloading muscle endurance is preserved (or enhanced) at the expense of muscle size and strength

Hackney, K. J.↗

Robust Tensioned Kevlar Suspension Design

One common but challenging problem in cryogenic engineering is to produce a mount that has excellent thermal isolation but is also rigid. Such mounts can be achieved by suspending the load from a network of fibers or strings held in tension. Kevlar fibers are often used for this purpose owing to their high strength and low thermal conductivity. A suite of compact design elements has been developed to improve the reliability of suspension systems made of Kevlar.

Young, Joseph B.↗

Spectral Attenuation of Sound in Dilute Suspensions with Nonlinear Particle Relaxation

Theoretical studies on the dissipation and dispersion of sound in two-phase suspensions have been briefly reviewed. Previous studies on the sound attenuation in particle-laden flows under Stokesian drag and conduction-controlled heat transfer have been extended to accommodate the nonlinear drag and heat transfer. It has been shown that for large particle-to-fluid density ratio, the particle Reynolds number bears a cubic relationship with Omega Tau(sub d) (where Omega is the circular frequency and Tau(sub d) the Stokesian particle relaxation time). This dependence leads to the existence of a peak value in the linear absorption coefficient occurring at a finite value Omega Tau (sub d). Comparison of the predictions with the test data for the spectral attenuation of sound with water injection in a perfectly expanded supersonic air jet shows a satisfactory trend of the theory accounting for nonlinear particle relaxation processes.

Kandula, M.↗

Integration of Mirror Design with Suspension System Using NASA's New Mirror Modeling Software

Advances in mirror fabrication are making very large space based telescopes possible. In many applications, only monolithic mirrors can meet the performance requirements. The existing and near-term planned heavy launch vehicles place a premium on lowest possible mass, and then available payload shroud sizes limit near term designs to 4 meter class mirrors. Practical 8 meter class and beyond designs could encourage planners to include larger shrouds, if it can be proven that such mirrors can be manufactured. These two factors, lower mass and larger mirrors, present the classic optimization problem. There is a practical upper limit to how large of a mirror can be supported by a purely kinematic mount system handling both operational and launch loads. This paper shows how the suspension system and mirror blank need to be designed simultaneously. We will also explore the concepts of auxiliary support systems which act only during launch and disengage on orbit. We will define required characteristics of these systems and show how they can substantially reduce the mirror mass.

Arnold, William R., Sr.↗