Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Long Duration Energy Storage Viability Survey

Energy storage technologies that can economically store and provide electricity over multi-day and seasonal timescales are likely to be a critical component of a sustainable and resilient energy system. This analysis performs a broad survey of energy storage technologies to find storage media that are promising for these long-duration energy storage applications.

levelized cost of storage↗

Streaming Data Reorganization at Scale with DeltaFS Indexed Massive Directories

We report complex storage stacks providing data compression, indexing, and analytics help leverage the massive amounts of data generated today to derive insights. It is challenging to perform this computation, however, while fully utilizing the underlying storage media. This is because, while storage servers with large core counts are widely available, single-core performance and memory bandwidth per core grow slower than the core count per die. Computational storage offers a promising solution to this problem by utilizing dedicated compute resources along the storage processing path. We present DeltaFS Indexed Massive Directories (IMDs), a new approach to computational storage. DeltaFS IMDs harvest available (i.e., not dedicated) compute, memory, and network resources on the compute nodes of an application to perform computation on data. We demonstrate the efficiency of DeltaFS IMDs by using them to dynamically reorganize the output of a real-world simulation application across 131,072 CPU cores. DeltaFS IMDs speed up reads by 1,740x while only slightly slowing down the writing of data during simulation I/O for in situ data processing.

97 MATHEMATICS AND COMPUTING↗

"PoliMOR: A Policy Engine \"Made-to-Order\" for Automated and Scalable Data Management in Lustre"

Modern supercomputing systems are increasingly reliant on hierarchical, multi-tiered file and storage system architectures due to cost-performance-capacity trade-offs. Within such multi-tiered systems, data management services are required to maintain healthy utilization, performance, and capacity levels. We present PoliMOR, a pragmatic and reliable policy-driven data management framework. PoliMOR is composed of modular, single-purpose agents that gather file system metadata and enforce policies on storage systems. PoliMOR facilitates automated and scalable data management with customizable agents tailored to HPC facility-specific storage systems and policies. Our evaluations demonstrate the scalability and performance of PoliMOR both by its individual agents and as a collective entity. We believe PoliMOR is widely applicable across HPC facilities with large-scale data management challenges and will garner interest from the HPC community, given its flexible and open-source nature.

George, Anjus↗

Performance Evaluation of Gray-box and Machine Learning Models of a Thermal Energy Storage System with Active Insulation

An interior partition wall integrated with active thermal storage and a dynamic insulation system was built and then installed in an office building in Oak Ridge, Tennessee, TN. This smart wall, termed the Empower Wall, was equipped with embedded pipes in the building envelope core component and an additional pipe network enclosing rigid insulation to switch on and off the active insulation dynamically. The performance of the wall's contribution to cooling load reduction under different parameters has been investigated in previous publications. Aiming to be deployed into model predictive control and other optimization methods, simplified and reliable models for the developed wall and the room accommodating it are required. They are needed to characterize the properties and thermal response of both Empower Wall and building envelope, which form an essential component for accurate indoor temperature or cooling/heating demand prediction. In this study, simplified gray-box and regression models as well as machine learning model were developed and the performance of them were compared and analyzed.

Cui, Borui↗

CCUS deployment under the U.S. 45Q tax credit and adaptation by other North American Governments: MARKAL modeling results

In 2018, U.S. Congress passed the Bipartisan Budget Act, known as 45Q [H.R. 3761], expanding the corporate income tax credit for carbon capture utilization and storage (CCUS). 45Q provides a performance-based tax credit for carbon capture projects of $30/ton of carbon dioxide (CO 2 ) (tCO 2 ) for anthropogenic CO 2 going to enhanced oil recovery (EOR), and $50/tCO 2 if going to straight storage. There are several conditions; for example, there is a 12-year time limit on tax credits for a new plant that commences construction before 2024 [H.R. 3761]. Here, this study aims to test the incremental impact of the 45Q tax credits on CCUS deployment, CO 2 -EOR, and power generation technological changes for North American (the United States, Canada, and Mexico) long-term energy system development. The scenario results show that offering a 12-year CO 2 storage subsidy provides the motivation needed for CCUS investment during the 12-year subsidy period, and the benefits of such investment can be sustained over the 40-year lifetime under CO 2 taxation. The modeling results show that carbon capture generation replaces uncontrolled fossil-fueled power, not new or existing renewables, so power generation and corresponding emission reductions from renewables remain unaffected by the availability of 45Q in the United States. Our scenario with CCUS technological learning indicates that CCUS could play a very important role under stringent environmental constraints. Thus, accelerated support and funding for the large-scale CCUS demonstrations is important for the execution of both short- and long-term climate mitigation goals. Given the significant role of the United States, Canada, and Mexico on the world energy system, our results represent an important contribution to the study of global energy trends.

42 ENGINEERING↗

A techno-economic survey of energy storage media for long-duration energy storage applications

Energy storage technologies that can economically store and provide electricity over multi-day and seasonal timescales are likely to be a critical component of a sustainable and resilient energy system. In this analysis, we perform a broad survey of energy storage technologies to find storage media (SM) that are promising for these long-duration energy storage (LDES) applications. The energy capital cost of the SM is identified as a key figure of merit for LDES. We develop a data collection framework to collect material price and physical property data, which are used to calculate the energy capital cost floor for 376 SM. These costs are then compared with cost targets for the LDES applications. The results show a multitude of thermal and chemical SM are economically promising, including some synthetic fuels, sensible thermal, latent thermal, thermochemical, and batteries based on low-cost materials. In contrast, currently deployed energy storage systems such as lithium-ion batteries and pumped hydro storage do not appear to be promising systems for LDES applications.

25 ENERGY STORAGE↗

Assessing the New Home Market Opportunity: Case Study and Cost Modeling for Solar and Storage in 2030

Residential solar and storage markets are growing in the United States. With approximately 1 million new homes constructed every year, this represents a significant opportunity for solar and storage installations. Some homebuilders have begun to build new homes with solar and storage included as a standard offering. It is not clear how solar and storage is incorporated into the new construction process and at what cost. Further, it is unclear what barriers or opportunities exist to scale this model nationwide. To fill this gap in the literature, this research conducts a case study of Mandalay Homes' new solar and storage community in Arizona to gather lessons learned. From this foundation, we further generate a set of pathways to reduce install costs and expand solar and storage market penetration in this sector. To model existing and 2030 solar and storage costs, we use the National Renewable Energy Laboratory's (NREL's) bottom-up cost model. This modeling is further informed by 12 interviews conducted with new home builders, solar contractors, and other subject matter expert organizations. Our case study analysis generated three key considerations for other homebuilders including: 1. Educating local permitting, inspection, and in some cases utility officials on solar and storage products, designs, and code compliant building practices may be required. The need for education may decline as more local governments and utilities review and approve solar and storage projects. 2. Incorporating solar and storage systems into the homebuilding process can add complexity and related coordination challenges. This does not need to result in home construction delays, but can result in costly contractor "dry runs" to construction sites. 3. Deploying solar and storage at the time of new construction has significant economies of scale, which can improve the value proposition of the systems. The case study, extant literature, and interviews were used to model both existing and future solar and storage installation costs at time of new construction. Here, we find three key cost reduction opportunities relating to solar and battery storage hardware, customer acquisition, and overhead. If future contractors can maximize the cost reduction opportunities outlined here, residential new construction costs could decline by 8 - 25% by 2030, depending on the modeled scenario. Though we expect costs to decline through 2030, it is unclear which of these scenarios may ultimately appear. Interviewees further identified a variety of barriers across each cost category that could temper the savings shown here. At the same time, interviewees described several pathways to scale the new construction solar and storage market, beyond installation cost savings. Interviewees confirmed that changes in finance, rate design, resilience policies, deployment mandates, and DER aggregation could all support more market adoption than seen today. These findings suggest that there are significant opportunities to expand new construction markets and this research can serve as a baseline to assess progress in this segment through 2030.

14 SOLAR ENERGY↗

Reversible Solid Oxide Fuel Cell Systems for Energy Storage and Hydrogen Production

FuelCell Energy (FCE) studied the performance, design, and economics of a reversible solid-oxide fuel cell/electrolyzer integrated with a natural gas-based electricity generation plant and used as an energy storage system. Increased market penetration of renewable energy is challenging for operators of fossilbased plants which are not suited for quick turndown and ramp-up. Process simulations studies show that with utilization of waste heat from the power plant, a high roundtrip efficiency (RTE) around 70% is possible, providing excellent market potential for this energy storage technology, potentially providing improved economics and lifetime for such power plant. The market potential and economics as a function of production volume are analyzed in detail. FCE is continuing the development and commercialization of its solid oxide technology.

08 HYDROGEN↗

Regional Assessment for the CO 2 Storage Potential in the Northern Niagaran Pinnacle Reef Trend

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. The report describes the regional analysis of the Northern Niagaran Pinnacle Reef Trend (NNPRT) in Northern Michigan as part of the MRCSP programs Regional Assessment goals. The goal of this task was to perform an initial assessment of the geologic storage capacity and injectivity of the Northern Fairway of Michigan’s Niagaran Reef Trend. This was achieved through three main objectives: 1) development of a reef atlas, 2) understanding the regional trends in geology, and 3) estimating CO 2 and CO 2 -EOR resources. Data collected across multiple subtasks were integrated into a mappable database that could be accessed from many of the leading software. The reef atlas was used to map the reefs and associated characteristics across the entire NNPRT. Several methodologies were explored to estimate the CO 2 and CO 2 -EOR resources across the trend which included three scenarios: 1) storage only using fluid substitution and volumetric estimations, 2) CO 2 -EOR which applied proximity analysis concepts and measured performance metrics from the Core Energy reefs to predict performance at all oil reefs, and 3) enhanced storage scenario which combined CO 2 -EOR with fluid substitution to represent maximized storage after completion of CO 2 -EOR.

01 COAL, LIGNITE, AND PEAT↗

Enhanced electrochemical performance and extended cycling of resorcinol-formaldehyde derived N-doped carbon xerogel for alkali metal-ion (Li/Na/K) batteries

Resorcinol formaldehyde-derived carbon xerogel (RFC) is a versatile material with tuneable properties, synthesized through a simple sol-gel method. This study presents nitrogen-doped RF carbon xerogel (N-RFC) with 11.8 at% nitrogen doping, offering a microporous architecture ideal for alkali metal-ion (Li, Na, K) batteries. The porous N-doped framework enhances electrochemical performance by improving ion transport, increasing active storage sites, and significantly boosting metal-ion adsorption, particularly through pyrrolic nitrogen, as revealed by first-principles calculations supported by XPS analysis. N-RFC anodes showed excellent cycling stability, high-capacity retention, and fast charge/discharge capabilities, rendering them suitable for commercial applications. Notably, the N-RFC anode demonstrates high-rate long-term cycling stability, retaining its capacity of 83.5 % (188 mAh/g at 2 C-rate) and 50 % (133 mAh/g at 1250 mA/g) over 1000 cycles for Li and Na-ion batteries, respectively, favorable for commercial battery applications. Additionally, N-RFC demonstrates a reversible capacity of 120 mAh/g after 394 cycles with a retention of 82 % for K-ion batteries. The ability of the material to accommodate larger ions like Na + and K + further emphasizes its versatility and potential application in diverse alkali metal-ion battery systems.

25 ENERGY STORAGE↗

Investigating Performance of Geothermal Reservoirs With Bi-Directional Heat Transfer for Seasonal Thermal Storage Using Thermal-Hydraulic Reservoir Simulations

This paper presents initial simulation results of deep subsurface seasonal thermal storage of waste heat from a natural gas-fired power plant during the summer months for providing heating during winter months at the Cornell University main campus in Ithaca, New York. An injection temperature profile is calculated with the MEnU tool and numerical reservoir simulations are conducted with the simulator FALCON. Both a porous medium and large single fracture geothermal reservoir are considered at about 3 km depth with initial reservoir temperature of 75 degrees C. Simulations indicate that a much smaller reservoir - which is technically easier and less risky to develop - is sufficient when operating the reservoir for seasonal thermal storage instead of for continuous heat production. For example, storing 13 GWh of heat seasonally in a 100 m thick porous medium based on the Galway formation requires about 65 m of well spacing to limit the yearly variation in production temperature to 10 degrees C. Operating this reservoir for continuous heat production would require a well spacing of 365 m to limit the thermal decline to 10 degrees C after 10 years. Neglecting wellbore heat losses and assuming uniform and homogeneous properties, a round-trip thermal efficiency of 100% can be obtained if the yearly averaged injection temperature matches the initial reservoir temperature.

district heating↗

Experimental Investigation of a Phase Change Material Charged Finned-Tube Heat Exchanger

Understanding different thermal performance aspects of phase change material heat exchangers (PCM-HX) is critical for designing future energy-efficient thermal energy storage systems. This paper presents an experimental performance analysis of a vertically oriented annular finned-tube PCM-HX in a cylindrical container tested under six different melting and solidification test conditions, varied by heat transfer fluid’s (HTF) inlet temperatures and flow directions. The PCM-HX structure with 20 evenly spaced fins was 3D printed in aluminum, and the PCM-HX container was 285 mm in height. The PCM-HX average porosity was 89.7%, where the PCM mass was 246.4 g. Water served as the HTF, and a PCM with a nominal phase change temperature of 35 °C was selected. Instead of opaque conventional insulation sheets, a combination of air-and-argon-filled see-through insulation cylinders was assembled with the PCM-HX to visualize the phase-change phenomena, while minimizing the uncertainties due to heat loss. In total, there were 78 T-type thermocouples installed in the test section which allows a more precise assessment of thermal mass and heat loss, which are often neglected in similar studies found in the literature. We validated the reliability of the test facility as the repeated test results had negligible deviations under the same test conditions. The energy balances between the estimated theoretical and experimentally calculated PCM storage, considering heat loss and thermal mass, were within ±9% deviation for all test conditions. From the experimental investigations, we made several following observations. It was found that the melting pattern of the finned-tube PCM-HX with small gaps between the container wall and the fins was largely affected by the HTF flow directions, unlike the typical straight annular tube PCM-HX. For effective charging and discharging processes, a combination of upward melting and downward solidification is recommended to shorten the test duration. However, an upward solidification should be considered to minimize the cavity formation between the fins caused by the PCM volume contraction during the solidification process.

25 ENERGY STORAGE↗

Impact of size and thermal gradient on supercooling of phase change materials for thermal energy storage

Phase change material based thermal energy storage has many current and potential applications in the heating and cooling of buildings, battery and electronics thermal management, thermal textiles, and dry cooling of power plants. However, connecting lab scale thermal data obtained with differential scanning calorimetry (DSC) to the performance of large-scale practical systems has been a major challenge primarily due to the dependence of supercooling on the size and temperature gradient of the system. Here we show how a phase change material’s supercooling behavior can be characterized experimentally using common lab scale thermal analysis techniques. We then develop a statistics based theoretical model that uses the lab-scale data on small samples to quantitatively predict the supercooling performance for a general thermal energy storage application of any size, including also allowing for the possibility of temperature gradients. Finally, we validate the modeling methodology by comparing to experimental results for solid-solid phase change in neopentyl glycol, which shows how the model successfully predicts the changes in supercooling temperature across a large range of cooling rates (2 orders of magnitude) and volumes (3 orders of magnitude). By accounting for thermal gradients, the model avoids ~2x error incurred by lumped approximations.

36 MATERIALS SCIENCE↗

Performance Evaluation and Costs of a Combined Ground Source Heat Pump and Solar Photovoltaic Storage System in an Extreme Cold Climate

This report outlines the effectiveness and economics of a ground source heat pump system installed together with solar photovoltaic panels and a battery storage system in a local community building situated in a cold climate. The community building is a tribal building located in Ruby, Alaska. Power from solar photovoltaic panels is supplemented by electricity purchased from the local community microgrid. A ground source heat pump was commissioned three years after the building was occupied, and supplements the heat generated by a boiler for both heat and domestic hot water. Data collected over the 2021-2022 heating season shows that the heat pump is providing heat to the building about 19% of the time with an average coefficient of performance of 2.68, ranging from below 2.5 in winter to above 3.0 in summer. The solar photovoltaic panels provided 4,700 kWh of power used within the building and an additional 2,900 kWh exported to the microgrid. The solar-produced power used within the building nearly offsets the estimated annual electrical draw of the heat pump of 5,700 kWh. Due to the very high costs for shipping and installation to remote locations, projects such as this, while not economically feasible if self-funded, can save the community an estimated $76,051 over a period of 20-years. Fuel prices increasing by more than 25%, or subsidized electricity prices decreasing by more than 25%, make the ground source heat pump a more viable option economically. Unsubsidized electricity prices increasing by 25% or more make a solar photovoltaic system with battery storage nearly economically viable after a 20-year period for commercial or school buildings that are not eligible for Alaska's Power Cost Equalization program.

14 SOLAR ENERGY↗

Field Testing of Self-Healing Metallic Coatings for Internal Corrosion Protection of Natural Gas Pipelines

Internal corrosion occurs in natural gas pipelines primarily due to the presence of water, carbon dioxide, and hydrogen sulfide. Internal corrosion can eventually result in leakage, cracks, and rupture of the pipeline. The objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas using cold spray coatings. The corrosion behavior of carbon steel coated with self-healing zinc chromium (ZnCr) and zinc niobium (ZnNb) cold spray coatings was investigated in a natural gas environment. For comparison purposes, hot-dip galvanized steel (HDGS) was tested under the same conditions as cold spray coatings. The field test was performed at the NW Natural gas storage facility in Mist, Oregon. The field test was conducted in a 6-inch diameter pipe transporting wet natural gas out of an underground storage well at 500 psi and 4.4 °C. The coupons were tested for 15 and 32 days under stagnant and flow conditions, respectively. Weight loss method was used to measure the corrosion rate of metallic coatings. Post-corrosion surface characterization was performed on the specimen using a scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS). Crystalline phases were determined by X-ray diffraction (XRD). The field-test results confirmed that the metallic coatings provided corrosion protection of carbon steel exposed to wet natural gas under stagnant and flow conditions. The formation of the ZnCO 3 layer on top of ZnNb and ZnCr coatings led to passivation of the coatings which helps to reduce the self-corrosion. These layers form a barrier for diffusion of corrosive species to the surface.

03 NATURAL GAS↗

Frequency Control and Disturbance Containment Using Grid-Forming Embedded Storage Networks

The paper presents a distributed approach for operating a network of inverter-based energy storage resources embedded in a bulk power system. Departing from their traditional role of steady-state reserves, the storage assets in the network are utilized as frequency-responsive resources shaping system dynamics. The power electronics converter systems interfacing the storage resources are equipped with local controllers designed to respond under transient disturbances. To this end, a safety-constrained distributed control strategy is explored. The paper compares the performance of converter-interfaced grid-forming and grid-following storage networks for fast frequency control and disturbance containment/localization. Sensitivity studies are performed to study the impact of storage size, steady-state dispatch, and controller design on dynamic performance. The findings are presented through case studies with results from the IEEE test systems.

Chatterjee, Kaustav (ORCID:0000000153273860)↗

Characterizing Impacts of Storage Faults on HPC Applications: A methodology and insights

In recent years, the increasing complexity in scientific simulations and emerging demands for training heavy artificial intelligence models require massive and fast data accesses, which urges high-performance computing (HPC) platforms to equip with more advanced storage infrastructures such as solid-state disks (SSDs). While SSDs offer high-performance I/O, it remains unclear about the reliability challenges faced by the HPC applications under the SSD-related failures, in particular, failures resulting in data corruptions. The goal of this paper is to understand the impact of SSD-related data corruptions on the behaviors of complex HPC applications. To this end, we propose FFIS, a FUSE-based fault injection framework that systematically introduces storage faults into the application layer to model the errors originated from SSDs. FFIS is able to plant different I/O related faults into the data returned from underlying file systems, which also enables the investigation on the error resilience characteristics of the scientific file format for the first time. We demonstrate the use of FFIS with three representative real HPC applications, show how each application reacts to the data corruptions, and provide insights on the error resilience of the widely-adopted HDF5 file format for the HPC applications.

Fang, Bo↗