At least 523 records · Page 29

On the evolution of elastic properties during laboratory stick‐slip experiments spanning the transition from slow slip to dynamic rupture

Abstract The physical mechanisms governing slow earthquakes remain unknown, as does the relationship between slow and regular earthquakes. To investigate the mechanism(s) of slow earthquakes and related quasi‐dynamic modes of fault slip we performed laboratory experiments on simulated fault gouge in the double direct shear configuration. We reproduced the full spectrum of slip behavior, from slow to fast stick slip, by altering the elastic stiffness of the loading apparatus ( k ) to match the critical rheologic stiffness of fault gouge ( k c ). Our experiments show an evolution from stable sliding, when k > k c , to quasi‐dynamic transients when k ~ k c , to dynamic instabilities when k < k c . To evaluate the microphysical processes of fault weakening we monitored variations of elastic properties. We find systematic changes in P wave velocity ( V p ) for laboratory seismic cycles. During the coseismic stress drop, seismic velocity drops abruptly, consistent with observations on natural faults. In the preparatory phase preceding failure, we find that accelerated fault creep causes a V p reduction for the complete spectrum of slip behaviors. Our results suggest that the mechanics of slow and fast ruptures share key features and that they can occur on same faults, depending on frictional properties. In agreement with seismic surveys on tectonic faults our data show that their state of stress can be monitored by V p changes during the seismic cycle. The observed reduction in V p during the earthquake preparatory phase suggests that if similar mechanisms are confirmed in nature high‐resolution monitoring of fault zone properties may be a promising avenue for reliable detection of earthquake precursors.

Tinti, E.↗

Condition Monitoring of Wind Turbine Planetary Gearboxes Under Different Operating Conditions

Digitally enhanced services for wind power could reduce Operations and Maintenance (O&M) costs as well as the Levelised Cost Of Energy (LCOE). Therefore, there is a continuous need for advanced monitoring techniques which can exploit the opportunities of Internet of Things (IoT) and Big Data Analytics, revolutionizing the future of the energy sector. The heart of wind turbines is a rather complex epicyclic gearbox. Among others, extremely critical gearbox components which are often responsible for machinery stops are the rolling element bearings. The vibration signatures of bearings are rather weak compared to other components, such as gears, and as a result an extended number of signal processing techniques and tools have been proposed during the last decades, focusing towards accurate, early, and on time bearing fault detection with limited false alarms and missed detections. Envelope Analysis is one of the most important methodologies, where an envelope of the vibration signal is estimated usually after filtering around a frequency band excited by impacts due to the bearing faults. Different tools, such as Kurtogram, have been proposed in order to accurately select the optimum filter parameters (center frequency and bandwidth). Cyclic Spectral Correlation and Cyclic Spectral Coherence, based on Cyclostationary Analysis, have been proved as very powerful tools for condition monitoring. The monitoring techniques seem to have reached a mature level in case a machinery operates under steady speed and load. On the other hand, in case the operating conditions change, it is still unclear whether the change of the monitoring indicators is due to the change of the health of the machinery or due to the change of the operating parameters. Recently, the authors have proposed a new tool called IESFOgram, which is based on Cyclic Spectral Coherence and can automatically select the filtering band. Furthermore, the Cyclic Spectral Coherence is integrated along the selected frequency band leading to an Improved Envelope Spectrum. In this paper, the performance of the tool is evaluated and further extended on cases operating under different speeds and different loads. The effectiveness of the methodology is tested and validated on the National Renewable Energy Laboratory (NREL) wind turbine gearbox vibration condition monitoring benchmarking data set which includes various faults with different levels of diagnostic complexity as well as various speed and load operating conditions.

17 WIND ENERGY↗

DISCOVERY OF A WOLF-RAYET STAR THROUGH DETECTION OF ITS PHOTOMETRIC VARIABILITY

We report the serendipitous discovery of a heavily reddened Wolf-Rayet star that we name WR 142b. While photometrically monitoring a cataclysmic variable, we detected weak variability in a nearby field star. Low-resolution spectroscopy revealed a strong emission line at 7100 A, suggesting an unusual object and prompting further study. A spectrum taken with the Hobby-Eberly Telescope confirms strong He II emission and an N IV 7112 A line consistent with a nitrogen-rich Wolf-Rayet star of spectral class WN6. Analysis of the He II line strengths reveals no detectable hydrogen in WR 142b. A blue-sensitive spectrum obtained with the Large Binocular Telescope shows no evidence for a hot companion star. The continuum shape and emission line ratios imply a reddening of E(B - V) = 2.2-2.6 mag. We estimate that the distance to WR 142b is 1.4 {+-} 0.3 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

Clamp cell with in situ pressure monitoring for low-temperature neutron scattering measurements

In this study, a clamp pressure cell for neutron scattering experiments at low temperatures and in external magnetic fields under pressure up to 2 GPa has been fabricated and tested. The cell provides optical access to the sample space that allows instantaneous pressure determination during sample loading, cooling and measuring using ruby and/or samarium doped strontium tetraborate fluorescence monitoring. Additionally, a new calibration curve of the pressure-induced shift of the 7 D 0 - 5 F 0 (0-0) line in the fluorescent spectrum of SrB 4 O 7 :Sm 2+ for moderate pressures, P≤2 GPa, is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PHOTOMETRICALLY TRIGGERED KECK SPECTROSCOPY OF FERMI BL LACERTAE OBJECTS

We report on Keck spectra of 10 Fermi blazars. J0622+3326, previously unobserved, is shown to be a flat-spectrum radio quasar at redshift z = 1.062. The others are known BL Lac type objects that have resisted previous attempts to secure redshifts. Using a photometric monitoring campaign with the 0.76 m Katzman Automatic Imaging Telescope at Lick Observatory, we identified epochs when the relativistic jet emission was fainter than usual, thus triggering the Keck spectroscopy. This strategy gives improved sensitivity to stars and ionized gas in the host galaxy, thereby providing improved redshift constraints for seven of these sources.

79 ASTRONOMY AND ASTROPHYSICS↗

GIANT GROUND LEVEL ENHANCEMENT OF RELATIVISTIC SOLAR PROTONS ON 2005 JANUARY 20. I. SPACESHIP EARTH OBSERVATIONS

A ground level enhancement (GLE) is a solar event that accelerates ions (mostly protons) to GeV range energies in such great numbers that ground-based detectors, such as neutron monitors, observe their showers in Earth's atmosphere above the Galactic cosmic ray background. GLEs are of practical interest because an enhanced relativistic ion flux poses a hazard to astronauts, air crews, and aircraft electronics, and provides the earliest direct indication of an impending space radiation storm. The giant GLE of 2005 January 20 was the second largest on record (and largest since 1956), with up to 4200% count rate enhancement at sea level. We analyzed data from the Spaceship Earth network, supplemented to comprise 13 polar neutron monitor stations with distinct asymptotic viewing directions and Polar Bare neutron counters at South Pole, to determine the time evolution of the relativistic proton density, energy spectrum, and three-dimensional directional distribution. We identify two energy-dispersive peaks, indicating two solar injections. The relativistic solar protons were initially strongly beamed, with a peak maximum-to-minimum anisotropy ratio over 1000:1. The directional distribution is characterized by an axis of symmetry, determined independently for each minute of data, whose angle from the magnetic field slowly varied from about 60 Degree-Sign to low values and then rose to about 90 Degree-Sign . The extremely high relativistic proton flux from certain directions allowed 10 s tracking of count rates, revealing fluctuations of period {approx}> 2 minutes with up to 50% fractional changes, which we attribute to fluctuations in the axis of symmetry.

79 ASTRONOMY AND ASTROPHYSICS↗

IN SITU INFRARED MEASUREMENTS OF FREE-FLYING SILICATE DURING CONDENSATION IN THE LABORATORY

We developed a new experimental system for infrared (IR) measurements on free-flying nucleating nanoparticles in situ and applied it to studies on silicate particles. We monitored the condensation of magnesium-bearing silicate nanoparticles from thermally evaporated magnesium and silicon monoxide vapor under an atmosphere of oxygen and argon. The IR spectrum of newly condensed particles showed a spectral feature for non-crystalline magnesium-bearing silicate that is remarkably consistent with the IR spectrum of astronomically observed non-crystalline silicate around oxygen-rich evolved stars. The silicate crystallized at <500 K and eventually developed a high crystallinity. Because of the size effects of nanoparticles, the silicate would be expected to be like a liquid at least during the initial stages of nucleation and growth. Our experimental results therefore suggest decreasing the possible formation temperature of crystalline silicates in dust formation environments with relatively higher pressure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurement of Femtosecond Laser Plasma X-ray Spectra Using a Medipix Detector

A method for measuring the bremsstrahlung X-ray spectra of electrons accelerated in a laser plasma using Medipix matrices has been developed. The application of the matrix provides the spectrum accumulation in a much shorter time, as compared to detectors based on a scintillator and a photomultiplier commonly used for such measurements. This ensures dynamic monitoring of the X-ray characteristics and prompt adjustment of the laser source parameters to obtain the maximum X-ray yield and energy. The results of measurements of the X-ray spectra at the ILC MSU terawatt femtosecond-laser complex for various laser-plasma interaction regimes are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Feasibility of vibration monitoring of small rotating machines for the environmental control and life support systems (ECLSS) of the NASA advanced space craft

The application of vibration monitoring to the rotating machinery typical of ECLSS components in advanced NASA spacecraft was studied. It is found that the weighted summation of the accelerometer power spectrum is the most successful detection scheme for a majority of problem types. Other detection schemes studied included high-frequency demodulation, cepstrum, clustering, and amplitude processing.

Milner, G. Martin↗

Linear Spectral Analysis of Plume Emissions Using an Optical Matrix Processor

Plume spectrometry provides a means to monitor the health of a burning rocket engine, and optical matrix processors provide a means to analyze the plume spectra in real time. By observing the spectrum of the exhaust plume of a rocket engine, researchers have detected anomalous behavior of the engine and have even determined the failure of some equipment before it would normally have been noticed. The spectrum of the plume is analyzed by isolating information in the spectrum about the various materials present to estimate what materials are being burned in the engine. Scientists at the Marshall Space Flight Center (MSFC) have implemented a high resolution spectrometer to discriminate the spectral peaks of the many species present in the plume. Researchers at the Stennis Space Center Demonstration Testbed Facility (DTF) have implemented a high resolution spectrometer observing a 1200-lb. thrust engine. At this facility, known concentrations of contaminants can be introduced into the burn, allowing for the confirmation of diagnostic algorithms. While the high resolution of the measured spectra has allowed greatly increased insight into the functioning of the engine, the large data flows generated limit the ability to perform real-time processing. The use of an optical matrix processor and the linear analysis technique described below may allow for the detailed real-time analysis of the engine's health. A small optical matrix processor can perform the required mathematical analysis both quicker and with less energy than a large electronic computer dedicated to the same spectral analysis routine.

Gary, C. K.↗

Recent Advances in Radar Polarimetry and Polarimetric SAR Interferometry

The development of Radar Polarimetry and Radar Interferometry is advancing rapidly, and these novel radar technologies are revamping Synthetic Aperture Radar Imaging decisively. In this exposition the successive advancements are sketched; beginning with the fundamental formulations and high-lighting the salient points of these diverse remote sensing techniques. Whereas with radar polarimetry the textural fine-structure, target-orientation and shape, symmetries and material constituents can be recovered with considerable improvements above that of standard amplitude-only Polarization Radar ; with radar interferometry the spatial (in depth) structure can be explored. In Polarimetric-Interferometric Synthetic Aperture Radar (POL-IN-SAR) Imaging it is possible to recover such co-registered textural plus spatial properties simultaneously. This includes the extraction of Digital Elevation Maps (DEM) from either fully Polarimetric (scattering matrix) or Interferometric (dual antenna) SAR image data takes with the additional benefit of obtaining co-registered three-dimensional POL-IN-DEM information. Extra-Wide-Band POL-IN-SAR Imaging - when applied to Repeat-Pass Image Overlay Interferometry - provides differential background validation and measurement, stress assessment, and environmental stress-change monitoring capabilities with hitherto unattained accuracy, which are essential tools for improved global biomass estimation. More recently, by applying multiple parallel repeat-pass EWB-POL-D(RP)-IN-SAR imaging along stacked (altitudinal) or displaced (horizontal) flight-lines will result in Tomographic (Multi- Interferometric) Polarimetric SAR Stereo-Imaging , including foliage and ground penetrating capabilities. It is shown that the accelerated advancement of these modern EWB-POL-D(RP)-IN-SAR imaging techniques is of direct relevance and of paramount priority to wide-area dynamic homeland security surveillance and local-to-global environmental ground-truth measurement and validation, stress assessment, and stress-change monitoring of the terrestrial and planetary covers. In addition, various closely related topics of (i) acquiring additional and protecting existing spectral windows of the Natural Electromagnetic Spectrum (NES) pertinent to Remote Sensing; (ii) mitigating against common "Radio Frequency Interference (RFI)" and intentional Directive Jamming of Airborne & Space borne POL-IN-SAR Imaging Platforms are appraised.

Boerner, Wolfgang-Martin↗

RXTE Observations of the 1A 1118-61 in an Outburst, and the Discovery of a Cyclotron Line

We present the analysis of RXTE monitoring data obtained during the January 2009 outburst of the hard X-ray transient IA 1118-61. Using these observations the broadband (3.5-120 keV) spectrum of the source was measured for the first time ever. We have found that the broadband continuum spectrum of the source is similar to other accreting pulsars and is well described by several conventionally used phenomenological models. We have discovered that regardless of the applied continuum model, a prominent broad absorption feature at approx. 55 keV is observed. We interpret this feature as a Cyclotron Resonance Scattering Feature (CRSF). The observed CRSF energy is one of the highest known and corresponds to a magnetic field of B approx. 4.8 x 10(exp 12) G in the scattering region. Furthermore, our data suggests an iron emission line presence, which was not reported previously for lA 1118-61 as well. Timing properties of the source, including a strong spin-up, were found to be similar to those observed by CGRO/BATSE during the previous outburst, however the broadband capabilities of RXTE reveal a more complicated energy dependency of the pulse-profile.

Doroshenko, V.↗

Adaptive responses of the cardiovascular system to prolonged spaceflight conditions: assessment with Holter monitoring

This article presents selected findings obtained with Holter monitoring from two crew members of the expedition, performed during a 175-day space mission on board orbital space station "MIR." Using mathematical processing of daily cardiointervals files, 5-minute sections of records were analyzed consecutively. Then, the average daily values of indices, the average-per-every-eight-hours values (morning, evening, night) and mean values per hour were computed. The results of analysis showed that prolonged exposure of man to microgravity conditions leads to important functional alteration in human neuroautonomic regulatory mechanisms. Both crew members had significant increase of heart rate, the rise of stress index, the decrease in power of the spectrum in the range of respiratory sinus arrhythmia. These marked signs of activation of the sympathetic section of the vegetative nervous system showed individual variations. The analysis of the daily collection of cardiointervals with Holter monitoring allows us to understand and forecast the functional feasibilities of the human organism under a variety of stress conditions associated with acute and chronic microgravity exposure.

manned↗

Block diagonal representations for covariance based anomalous change detectors

Change detection methods are of crucial importance in many remote sensing applications such as monitoring and surveillance, where the goal is to identify and separate changes of interest from pervasive changes inevitably present in images taken at different times and in different environmental and illumination conditions. Anomalous change detection (ACD) methods aim to identify rare, unusual, or anomalous changes among the changes of interest. Covariance-based ACD methods provide a powerful tool for detection of unusual changes in hyper-spectral images. In this paper we study the properties of the eigenvalue spectra of a family of ACD matrices in order to better understand the algebraic and numerical behavior of the covariance-based quadratic ACD methods. We propose to use singular vectors of covariance matrices of two hyper-spectral images in whitened coordinates for obtaining block-diagonal representations of the matrices of quadratic ACD methods. SVD transformation gives an equivalent representation of ACD matrices in compact block-diagonal form. In the paper we show that the eigenvalue spectrum of a block-diagonal ACD matrix can be identified analytically as a function of the singular value spectrum of the corresponding covariance matrix in whitened coordinates.

97 MATHEMATICS AND COMPUTING↗

Smoothness monitors for compressible flow computation

In [SY04, YS07] and references cited therein, the authors introduced the concept of employing multiresolution wavelet decomposition of computed flow data as smoothness monitors (flow sensors) to indicate the amount and location of built-in numerical dissipation that can be eliminated or further reduced in shock-capturing schemes. Studies indicated that this approach is able to limit the use of numerical dissipation with improved accuracy compared with standard shock-capturing methods. The studies in [SY04, YS07] were limited to low order multiresolution redundant wavelets with low level supports and low order vanishing moments. The objective of this paper is to expand the previous investigation to include higher order redundant wavelets with larger support and higher order vanishing moments for a wider spectrum of flow type and flow speed applications.

99 GENERAL AND MISCELLANEOUS↗

Validation of MODIS FLH and In Situ Chlorophyll a from Tampa Bay, Florida (USA)

Satellite observation of phytoplankton concentration or chlorophyll-a (chla) is an important characteristic, critically integral to monitoring coastal water quality. However, the optical properties of estuarine and coastal waters are highly variable and complex and pose a great challenge for accurate analysis. Constituents such as suspended solids and dissolved organic matter and the overlapping and uncorrelated absorptions in the blue region of the spectrum renders the blue-green ratio algorithms for estimating chl-a inaccurate. Measurement of suninduced chlorophyll fluorescence, on the other hand, which utilizes the near infrared portion of the electromagnetic spectrum may, provide a better estimate of phytoplankton concentrations. While modelling and laboratory studies have illustrated both the utility and limitations of satellite algorithms based on the sun induced chlorophyll fluorescence signal, few have examined the empirical validity of these algorithms or compared their accuracy against bluegreen ratio algorithms . In an unprecedented analysis using a long term (2003-2011) in situ monitoring data set from Tampa Bay, Florida (USA), we assess the validity of the FLH product from the Moderate Resolution Imaging Spectrometer against a suite of water quality parameters taken in a variety of conditions throughout this large optically complex estuarine system. . Overall, the results show a 106% increase in the validity of chla concentration estimation using FLH over the standard chla estimate from the blue-green OC3M algorithm. Additionally, a systematic analysis of sampling sites throughout the bay is undertaken to understand how the FLH product responds to varying conditions in the estuary and correlations are conducted to see how the relationships between satellite FLH and in situ chlorophyll-a change with depth, distance from shore, from structures like bridges, and nutrient concentrations and turbidity. Such analysis illustrates that the correlations between FLH and in situ chla measurements increases with increasing distance between monitoring sites and structures like bridges and shore. Due probably to confounding factors, expected improvement in the FLH- chla relationship was not clearly noted when increasing depth and distance from shore alone (not including bridges). Correlations between turbidity and nutrient concentrations are discussed further and principle component analyses are employed to address the relationships between the multivariate data sets. A thorough understanding of how satellite FLH algorithms relate to in situ water quality parameters will enhance our understanding of how MODIS s global FLH algorithm can be used empirically to monitor coastal waters worldwide.

Fischer, Andrew↗