Transit telescope designs optimized for multiple object spectroscopy with fibers

Instruments to simultaneously study the spectra of many objects in the field of view of a telescope can be made using fused silica fibers. The spectrograph at the 2.3m telescope of the University of Arizona has been modified for such operation, and is used routinely to study the dynamics of galaxy clusters. Consideration has been given to how the multifiber technique can best be used to obtain spectra of the many faint objects identified by deep transit survey instruments and new space and radio telescopes. A transit survey such as that planned by McGraw et al. (1980), with CCDs at the focus of a 2m transit telescope, will identify objects down to 24th magnitude, and down to 22nd magnitude will give very complete data on variability and optical energy distribution. A telescope with much larger aperture is required for spectroscopic follow up. It is suggested that large telescopes dedicated to this type of work can be made and operated for only a fraction of the cost of a general-purpose telescope.

Angel, J. R. P.↗

Space missions in comets

Recent advances in the techniques and instruments of cometary research are described. Consideration is given to the development of the first space-based platforms for cometary observations in the 1970s, including the OGO-5 and OAO-2 ultraviolet satellites, as well as IRAS. The expectations for the scientific return from space missions in the 1980s and 1990s are also discussed, with attention given to the Giotto flyby; the Soviet VEGA missions; and two Japanese spacecraft missions Sakigake and Suise. The imaging and spectroscopic experiments to be carried out during the Giotto mission are described in detail.

Neugebauer, M.↗

Spectroscopy and multivariate analyses applications related to solid rocket nozzle bondline

Chemical composition and molecular orientation define the properties of materials. Information related to chemical composition and molecular configuration is obtained by various forms of spectroscopy. Software algorithms developed for multivariate analyses, expert systems, and Artificial Intelligence (AI) are used to conduct repetitive operations. The techniques are believed to be of particular significance toward achieving TQM objectives. The objective was to obtain information related to the quality of the bondline in the solid rocket motor, SRM, nozzle. Hysol 934 NA, a room temperature curing epoxide resin, is used as the bonding agent. A good bond requires that the adhesive be placed on a properly prepared metal surface, the adhesives Part A and B be mixed in appropriate ratio from material within shelf life specifications. Spectroscopic data was obtained for surfaces prepared according to specifications, contaminated metal surfaces, samples of the epoxide adhesive at times that represent shelf aging from 3 months to 2 years, several mix ratio of A to B, and curing material. Temperature was found to be a significant factor. The study concentrated on pot life and mix ratio.

Arendale, W. F.↗

Development of Ceramic Solid-State Laser Host Material

Polycrystalline ceramic laser materials are gaining importance in the development of novel diode-pumped solid-state lasers. Compared to single-crystals, ceramic laser materials offer advantages in terms of ease of fabrication, shape, size, and control of dopant concentrations. Recently, we have developed Neodymium doped Yttria (Nd:Y2O3) as a solid-state ceramic laser material. A scalable production method was utilized to make spherical non agglomerated and monodisperse metastable ceramic powders of compositions that were used to fabricate polycrystalline ceramic material components. This processing technique allowed for higher doping concentrations without the segregation problems that are normally encountered in single crystalline growth. We have successfully fabricated undoped and Neodymium doped Yttria material up to 2" in diameter, Ytterbium doped Yttria, and erbium doped Yttria. We are also in the process of developing other sesquioxides such as scandium Oxide (Sc2O3) and Lutesium Oxide (Lu2O3) doped with Ytterbium, erbium and thulium dopants. In this paper, we present our initial results on the material, optical, and spectroscopic properties of the doped and undoped sesquioxide materials. Polycrystalline ceramic lasers have enormous potential applications including remote sensing, chem.-bio detection, and space exploration research. It is also potentially much less expensive to produce ceramic laser materials compared to their single crystalline counterparts because of the shorter fabrication time and the potential for mass production in large sizes.

Prasad, Narasimha S.↗

Exoplanet Biosignatures: Observational Prospects

Exoplanet hunting efforts have revealed the prevalence of exotic worlds with diverse properties, including Earth-sized bodies, which has fueled our endeavor to search for life beyond the Solar System. Accumulating experiences in astrophysical, chemical, and climatological characterization of uninhabitable planets are paving the way to characterization of potentially habitable planets. In this paper, we review our possibilities and limitations in characterizing temperate terrestrial planets with future observational capabilities through the 2030s and beyond, as a basis of a broad range of discussions on how to advance "astrobiology" with exoplanets. We discuss the observability of not only the proposed biosignature candidates themselves but also of more general planetary properties that provide circumstantial evidence, since the evaluation of any biosignature candidate relies on its context. Characterization of temperate Earth-sized planets in the coming years will focus on those around nearby late-type stars. The James Webb Space Telescope (JWST) and later 30-meter-class ground-based telescopes will empower their chemical investigations. Spectroscopic studies of potentially habitable planets around solar-type stars will likely require a designated spacecraft mission for direct imaging, leveraging technologies that are already being developed and tested as part of the Wide Field InfraRed Survey Telescope (WFIRST) mission. Successful initial characterization of a few nearby targets will be an important touchstone toward a more detailed scrutiny and a larger survey that are envisioned beyond 2030. The broad outlook this paper presents may help develop new observational techniques to detect relevant features as well as frameworks to diagnose planets based on the observables.

Characterization↗

Photometric and spectroscopic observations of SN 1990E in NGC 1035 - Observational constraints for models of type II supernovae

We present 126 photometric and 30 spectral observations of SN 1990E spanning from 12 days before B maximum to 600 days past discovery. These observations show that SN 1990E was of type II-P, displaying hydrogen in its spectrum, and the characteristic plateau in its light curve. SN 1990E is one of the few SNe II which has been well observed before maximum light, and we present evidence that this SN was discovered very soon after its explosion. In the earliest spectra we identify, for the first time, several N II lines. We present a new technique for measuring extinction to SNe II based on the evolution of absorption lines, and use this method to estimate the extinction to SN 1990E, A(V) = 1.5 +/- 0.3 mag. From our photometric data we have constructed a bolometric light curve for SN 1990E and show that, even at the earliest times, the bolometric luminosity was failing rapidly. We use the late-time bolometric light curve to show that SN 1990E trapped a majority of the gamma rays produced by the radioactive decay of Co-56, and estimate that SN 1990E ejected an amount of Ni-56 virtually identical to that of SN 1987A.

Schmidt, Brian P.↗

The spectral classification of chromospherically active binary stars with composite spectra

This paper presents and analyzes blue and red-wavelength high-resolution spectra of twelve chromospherically active binary or triple systems with composite spectra. Spectral classifications for the individual stellar components are derived by means of the 'spectrum-synthesis' technique and are compared to stellar evolutionary models and observed masses and/or mass ratios. Also presented is a carefully selected set of MK reference stars of luminosity class III, IV, and V, and spectral type A9-K5, and v sin i less than 10 km/s, to cover the spectral range of the components of chromospherically active binary systems of the RS CVn-type. New values of v sin i are determined for some of the reference and program stars. Two spectroscopic binaries have been discovered.

Strassmeier, K. G.↗

Two-photon laser-induced fluorescence detection of OH

The TP-LIF OH sensor is based on the principle that a molecule having multiple energy states, all of which are bonding, can be pumped into the highest state with the resulting fluorescence being blue-shifted relative to all pumping wavelengths. In this way, one can successfully discriminate against virtually all noise sources in the system using long wavelength blocking filters in conjunction with solar-blind photomultiplier tubes. Thus, these systems tend to be signal limited rather than signal-to-noise limited as is true of the SP-LIF technique as well as other conventional analytical methods. The trick to achieving the above sampling scheme, with high efficiency, is in the use of high photon fluxes of short time duration. Obviously, the latter type of light source is fulfilled nicely by available pulsed lasers. From an operational point of view, however, this laser source needs to be tunable. The latter characteristic permits extremely high selectivity for the detection of a diatomic or simple polyatomic molecule by taking advantage of the high-resolution spectroscopic features of these type species.

Davis, D. D.↗

Microshutter Arrays for the JWST NIRSpec

A primary goal of the James Webb Space Telescope (JWST) is to characterize the birth and evolution of galaxies by imaging and spectroscopic observations. The telescope will use a Near Infrared Camera and a Near Infrared Spectrometer (NIRSpec) to carry out this program. The 3.6 x 3.6 field of NIRSpec will contain thousands of candidate high redshift galaxies. With such a high candidate object density, simultaneous multi-object capability is essential. This capability requires a programmable object selection mask to eliminate sky background and to reduce source confusion caused. We are developing a two-dimensional programmable field mask for NIRSpec. These masks employ micromechanical (MEMS) techniques to provide source selection over the NIRSpec field of view. The first flight format arrays (171x365 shutters) have been fabricated and full functionality of these arrays has been demonstrated in lab tests. Qualification tests are in progress to demonstrate readiness for flight, and will be complete in the early fall of 2006. In this paper, I describe performance of this critical new technology, and progress in making the devices ready for a 2008 delivery to ESA for inclusion in the NIRSpec.

Moseley, Samuel H.↗

Microshutter Arrays for the JWST NIRSpec

A primary goal of the James Webb Space Telescope (JWST) is to characterize the birth and evolution of galaxies by imaging and spectroscopic observations. The telescope will use a Near Infrared Camera and a Near Infrared Spectrometer (NIRSpec) to carry out this program. The 3.6' x 3.6' field of NIRSpec will contain thousands of candidate high redshift galaxies. With such a high candidate object density, simultaneous multi-object capability is essential. This capability requires a programmable object selection mask to eliminate sky background and to reduce source confusion caused. We are developing a two-dimensional programmable field mask for NIRSpec. These masks employ micromechanical (MEMS) techniques to provide source selection over the NIRSpec field of view. The first flight format arrays (171x365 shutters) have been fabricated and full functionality of these arrays has been demonstrated in lab tests.

Moseley, Samuel H.↗

Accurate quantum chemical calculations

An important goal of quantum chemical calculations is to provide an understanding of chemical bonding and molecular electronic structure. A second goal, the prediction of energy differences to chemical accuracy, has been much harder to attain. First, the computational resources required to achieve such accuracy are very large, and second, it is not straightforward to demonstrate that an apparently accurate result, in terms of agreement with experiment, does not result from a cancellation of errors. Recent advances in electronic structure methodology, coupled with the power of vector supercomputers, have made it possible to solve a number of electronic structure problems exactly using the full configuration interaction (FCI) method within a subspace of the complete Hilbert space. These exact results can be used to benchmark approximate techniques that are applicable to a wider range of chemical and physical problems. The methodology of many-electron quantum chemistry is reviewed. Methods are considered in detail for performing FCI calculations. The application of FCI methods to several three-electron problems in molecular physics are discussed. A number of benchmark applications of FCI wave functions are described. Atomic basis sets and the development of improved methods for handling very large basis sets are discussed: these are then applied to a number of chemical and spectroscopic problems; to transition metals; and to problems involving potential energy surfaces. Although the experiences described give considerable grounds for optimism about the general ability to perform accurate calculations, there are several problems that have proved less tractable, at least with current computer resources, and these and possible solutions are discussed.

Bauschlicher, Charles W., Jr.↗

Solubilization and spore recovery from silicone polymers

A non-sporicidal technique for solvent degradation of cured silicone polymers was developed which involves chemical degradation of cured silicone polymers by amine solvents at room temperature. Substantial improvements were obtained in the recovery of seeded spores from room temperature cured polymers as compared to the standard recovery procedures, which indicates that the curing process is not sufficiently exothermic to reduce spore viability. The dissolution reaction of cured silicone polymers whith amine solvents is proposed to occur by bimolecular nucleophilic displacement. The chemical structure of silicone polymers was determined by spectroscopic methods. The phenyl to methyl ratio, R/Si ratio, molecular weight, and hydroxyl content of the silicone resins were determined.

Hsiao, Y. C.↗

An ab initio investigation of the structure, vibrational frequencies, and intensities of HO2 and HOCl

The infrared spectral intensities for HOCl and HO2 have been calculated using a new ab initio technique. Theoretical results for the geometries, vibrational frequencies, and the dipole moments of these species are also reported. All of the calculations were performed at the SCF level using near Hartree-Fock quality basis sets. The results for the molecular geometries and the vibrational frequencies are in good agreement with available experimental data. It is believed that the computed intensities are accurate to at least 50%. The results should be helpful in attempts to determine the stratospheric abundance of HOCl and HO2 by in situ infrared spectroscopic measurements.

Komornicki, A.↗

X-ray spectrometer spectrograph telescope system

A new sounding rocket payload that has been developed for X-ray spectroscopic studies of the solar corona is described. The instrument incorporates a grazing incidence Rowland mounted grating spectrograph and an extreme off-axis paraboloic sector feed system to isolate regions of the sun of order 1 x 10 arc seconds in size. The focal surface of the spectrograph is shared by photographic and photoelectric detection systems, with the latter serving as a part of the rocket pointing system control loop. Fabrication and alignment of the optical system is based on high precision machining and mechanical metrology techniques. The spectrograph has a resolution of 16 milliangstroms and modifications planned for future flights will improve the resolution to 5 milliangstroms, permitting line widths to be measured.

Bruner, E. C., Jr.↗

Application of Laser Mass Spectrometry to Art and Archaeology

REMPI laser mass spectrometry is a combination of resonance enhanced multiphoton ionization spectroscopy and time of flight mass spectrometry, This technique enables the collection of mass specific optical spectra as well as of optically selected mass spectra. Analytes are jet-cooled by entrainment in a molecular beam, and this low temperature gas phase analysis has the benefit of excellent vibronic resolution. Utilizing this method, mass spectrometric analysis of historically relevant samples can be simplified and improved; Optical selection of targets eliminates the need for chromatography while knowledge of a target's gas phase spectroscopy allows for facile differentiation of molecules that are in the aqueous phase considered spectroscopically indistinguishable. These two factors allow smaller sample sizes than commercial MS instruments, which in turn will require less damage to objects of antiquity. We have explored methods to optimize REMPI laser mass spectrometry as an analytical tool to archaeology using theobromine and caffeine as molecular markers in Mesoamerican pottery, and are expanding this approach to the field of art to examine laccaic acid in shellacs.

Gulian, Lase Lisa E.↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗

Experimental tests of a single-photon calorimeter for X-ray spectroscopy

Tests have been made of a nondispersive spectroscopic X-ray detector which operates by measuring the temperature rise following absorption of a single photon. Thermal pulses from 6-keV X-rays have been observed, and the different amplitudes resulting from Mn K-alpha and K-beta events have been resolved. This device was assembled to make quantitative tests of theoretical calculations of the properties of such detectors, and its high heat capacity does not allow it to attain the very high resolution predicted for detectors made by more sophisticated, but still straightforward, techniques. Both the measured resolution of 270-eV full width at half maximum and the absolute amplitude of the response are consistent with predictions. Nonthermal effects in the thermistor limit the precision of this comparison to about 30 percent.

Mccammon, D.↗

Estimating the Properties of Hard X-Ray Solar Flares by Constraining Model Parameters

We wish to better constrain the properties of solar flares by exploring how parameterized models of solar flares interact with uncertainty estimation methods. We compare four different methods of calculating uncertainty estimates in fitting parameterized models to Ramaty High Energy Solar Spectroscopic Imager X-ray spectra, considering only statistical sources of error. Three of the four methods are based on estimating the scale-size of the minimum in a hypersurface formed by the weighted sum of the squares of the differences between the model fit and the data as a function of the fit parameters, and are implemented as commonly practiced. The fourth method is also based on the difference between the data and the model, but instead uses Bayesian data analysis and Markov chain Monte Carlo (MCMC) techniques to calculate an uncertainty estimate. Two flare spectra are modeled: one from the Geostationary Operational Environmental Satellite X1.3 class flare of 2005 January 19, and the other from the X4.8 flare of 2002 July 23.We find that the four methods give approximately the same uncertainty estimates for the 2005 January 19 spectral fit parameters, but lead to very different uncertainty estimates for the 2002 July 23 spectral fit. This is because each method implements different analyses of the hypersurface, yielding method-dependent results that can differ greatly depending on the shape of the hypersurface. The hypersurface arising from the 2005 January 19 analysis is consistent with a normal distribution; therefore, the assumptions behind the three non- Bayesian uncertainty estimation methods are satisfied and similar estimates are found. The 2002 July 23 analysis shows that the hypersurface is not consistent with a normal distribution, indicating that the assumptions behind the three non-Bayesian uncertainty estimation methods are not satisfied, leading to differing estimates of the uncertainty. We find that the shape of the hypersurface is crucial in understanding the output from each uncertainty estimation technique, and that a crucial factor determining the shape of hypersurface is the location of the low-energy cutoff relative to energies where the thermal emission dominates. The Bayesian/MCMC approach also allows us to provide detailed information on probable values of the low-energy cutoff, Ec, a crucial parameter in defining the energy content of the flare-accelerated electrons. We show that for the 2002 July 23 flare data, there is a 95% probability that Ec lies below approximately 40 keV, and a 68% probability that it lies in the range 7-36 keV. Further, the low-energy cutoff is more likely to be in the range 25-35 keV than in any other 10 keV wide energy range. The low-energy cutoff for the 2005 January 19 flare is more tightly constrained to 107 +/- 4 keV with 68% probability.

X-rays↗