Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

FUNDAMENTAL PARAMETERS AND SPECTRAL ENERGY DISTRIBUTIONS OF YOUNG AND FIELD AGE OBJECTS WITH MASSES SPANNING THE STELLAR TO PLANETARY REGIME

We combine optical, near-infrared, and mid-infrared spectra and photometry to construct expanded spectral energy distributions for 145 field age (>500 Myr) and 53 young (lower age estimate <500 Myr) ultracool dwarfs (M6-T9). This range of spectral types includes very low mass stars, brown dwarfs, and planetary mass objects, providing fundamental parameters across both the hydrogen and deuterium burning minimum masses for the largest sample assembled to date. A subsample of 29 objects have well constrained ages as probable members of a nearby young moving group. We use 182 parallaxes and 16 kinematic distances to determine precise bolometric luminosities (L{sub bol}) and radius estimates from evolutionary models give semi-empirical effective temperatures (T{sub eff}) for the full range of young and field age late-M, L, and T dwarfs. We construct age-sensitive relationships of luminosity, temperature, and absolute magnitude as functions of spectral type and absolute magnitude to disentangle the effects of degenerate physical parameters such as T{sub eff}, surface gravity, and clouds on spectral morphology. We report bolometric corrections in J for both field age and young objects and find differences of up to a magnitude for late-L dwarfs. Our correction in Ks shows a larger dispersion but not necessarily a different relationship for young and field age sequences. We also characterize the NIR–MIR reddening of low gravity L dwarfs and identify a systematically cooler T{sub eff} of up to 300 K from field age objects of the same spectral type and 400 K cooler from field age objects of the same M{sub H} magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY SPECTRAL RESIDUALS IN NGC 5408 X-1: DIFFUSE EMISSION FROM STAR FORMATION, OR THE SIGNATURE OF A SUPER-EDDINGTON WIND?

If ultraluminous X-ray sources (ULXs) are powered by accretion onto stellar remnant black holes, then many must be accreting at super-Eddington rates. It is predicted that such high accretion rates should give rise to massive, radiatively driven winds. However, observational evidence of a wind, in the form of absorption or emission features, has remained elusive. As such, the reported detection of X-ray spectral residuals in XMM-Newton spectra of NGC 5408 X-1, which could be related to absorption in a wind is potentially very exciting. However, it has previously been assumed by several authors that these features simply originate from background diffuse plasma emission related to star formation in the ULX’s host galaxy. In this work we utilize the spatial resolving power of Chandra to test whether we can rule out this latter interpretation. We demonstrate that the majority of the luminosity in these spectral features is emitted from a highly localized region close to the ULX, and appears point-like even with Chandra. It is therefore highly likely that the spectral features are associated with the ULX itself, and little of the flux in this spectral component originates from spatially extended emission in the host galaxy. This may be consistent with the suggestion of absorption in an optically thin phase of a super-Eddington wind. Alternatively, we could be seeing emission from collisionally ionized material close to the black hole, but critically this would be difficult to reconcile with models where the source inclination largely determines the observed X-ray spectral and timing properties.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SIMULTANEOUS OPTICAL-TO-X-RAY SPECTRAL ENERGY DISTRIBUTION OF SOFT X-RAY SELECTED ACTIVE GALACTIC NUCLEI OBSERVED BY SWIFT

We report Swift observations of a sample of 92 bright soft X-ray selected active galactic nuclei (AGNs). This sample represents the largest number of AGNs observed to study the spectral energy distribution (SED) of AGNs with simultaneous optical/UV and X-ray data. The principal motivation of this study is to understand the SEDs of AGNs in the optical/UV to X-ray regime and to provide bolometric corrections which are important in determining the Eddington ratio L/L {sub Edd}. In particular, we rigorously explore the dependence of the UV-EUV contribution to the bolometric correction on the assumed EUV spectral shape. We find strong correlations of the spectral slopes {alpha}{sub X} and {alpha}{sub UV} with L/L {sub Edd}. Although narrow-line Seyfert 1 galaxies (NLS1s) have steeper {alpha}{sub X} and higher L/L {sub Edd} than broad-line Seyfert 1 galaxies (BLS1s), their optical/UV to X-ray spectral slopes {alpha}{sub ox} and optical/UV slopes {alpha}{sub UV} are very similar. The mean SED of NLS1s shows that in general this type of AGNs appears to be fainter in the UV and at hard X-ray energies than BLS1s. We find a strong correlation between {alpha}{sub X} and {alpha}{sub UV} for AGNs with X-ray spectral slopes {alpha}{sub X}<1.6. For AGNs with steeper X-ray spectra, both this relation and the relation between {alpha}{sub X} and L/L {sub Edd} break down. At {alpha}{sub X}{approx}1.6, L/L {sub Edd} reaches unity. We note an offset in the {alpha}{sub UV}-L/L {sub Edd} relation between NLS1s and BLS1s. We argue that {alpha}{sub UV} is a good estimator of L/L {sub Edd} and suggest that {alpha}{sub UV} can be used to estimate L/L {sub Edd} in high-redshift QSOs. Although NLS1s appear to be highly variable in X-rays, they only vary marginally in the UV.

79 ASTRONOMY AND ASTROPHYSICS↗

Negative running of the spectral index, hemispherical asymmetry and the consistency of Planck with large r

Planck favours a negative running of the spectral index, with the likelihood being dominated by low multipoles l ∼< 50 and no preference for running at higher l. A negative spectral index is also necessary for the 2- Planck upper bound on the tensor-to-scalar ratio r to be consistent with values significantly larger than 0.1. Planck has also observed a hemispherical asymmetry of the CMB power spectrum, again mostly at low multipoles. Here we consider whether the physics responsible for the hemispherical asymmetry could also account for the negative running of the spectral index and the consistency of Planck with a large value of r. A negative running of the spectral index can be generated if the hemispherical asymmetry is due to a scale- and space-dependent modulation which suppresses the CMB power spectrum at low multipoles. We show that the observed hemispherical asymmetry at low l can be generated while satisfying constraints on the asymmetry at higher l and generating a negative spectral index of the right magnitude to account for the Planck observation and to allow Planck to be consistent with a large value of r.

79 ASTRONOMY AND ASTROPHYSICS↗

Ambiguity in running spectral index with an extra light field during inflation

At the beginning of inflation there could be extra dynamical scalar fields that will soon disappear (become static) before the end of inflation. In the light of multi-field inflation, those extra degrees of freedom may alter the time-dependence of the original spectrum of the curvature perturbation. It is possible to remove such fields introducing extra number of e-foldings prior to 0N{sub e}∼ 6, however such extra e-foldings may make the trans-Planckian problem worse due to the Lyth bound. We show that such extra scalar fields can change the running of the spectral index to give correction of ± 0.01 without adding significant contribution to the spectral index. The corrections to the spectral index (and the amplitude) could be important in considering global behavior of the corrected spectrum, although they can be neglected in the estimation of the spectrum and its spectral index at the pivot scale. The ambiguity in the running of the spectral index, which could be due to such fields, can be used to nullify tension between BICEP2 and Planck experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

CMB spectral distortions as solutions to the Boltzmann equations

We propose to re-interpret the cosmic microwave background spectral distortions as solutions to the Boltzmann equation. This approach makes it possible to solve the second order Boltzmann equation explicitly, with the spectral y distortion and the momentum independent second order temperature perturbation, while generation of μ distortion cannot be explained even at second order in this framework. We also extend our method to higher order Boltzmann equations systematically and find new type spectral distortions, assuming that the collision term is linear in the photon distribution functions, namely, in the Thomson scattering limit. As an example, we concretely construct solutions to the cubic order Boltzmann equation and show that the equations are closed with additional three parameters composed of a cubic order temperature perturbation and two cubic order spectral distortions. The linear Sunyaev-Zel'dovich effect whose momentum dependence is different from the usual y distortion is also discussed in the presence of the next leading order Kompaneets terms, and we show that higher order spectral distortions are also generated as a result of the diffusion process in a framework of higher order Boltzmann equations. The method may be applicable to a wider class of problems and has potential to give a general prescription to non-equilibrium physics.

79 ASTRONOMY AND ASTROPHYSICS↗

EXPANDED VERY LARGE ARRAY OBSERVATIONS OF GALACTIC SUPERNOVA REMNANTS: WIDE-FIELD CONTINUUM AND SPECTRAL-INDEX IMAGING

The radio continuum emission from the Galaxy has a rich mix of thermal and non-thermal emission. This very richness makes its interpretation challenging since the low radio opacity means that a radio image represents the sum of all emission regions along the line of sight. These challenges make the existing narrowband radio surveys of the Galactic plane difficult to interpret: e.g., a small region of emission might be a supernova remnant (SNR) or an H II region, or a complex combination of both. Instantaneous wide bandwidth radio observations in combination with the capability for high-resolution spectral-index mapping can be directly used to disentangle these effects. Here we demonstrate simultaneous continuum and spectral-index imaging capability at the full continuum sensitivity and resolution using newly developed wide-band wide-field imaging algorithms. Observations were conducted in the L and C bands with a total bandwidth of 1 and 2 GHz, respectively. We present preliminary results in the form of a full-field continuum image covering the wide-band sensitivity pattern of the EVLA centered on a large but poorly studied SNR (G55.7 + 3.4) and relatively narrower field continuum and spectral-index maps of three fields containing SNR and diffused thermal emission. We demonstrate that spatially resolved spectral-index maps differentiate regions with emission of different physical origins (spectral-index variation across composite SNRs and separation of thermal and non-thermal emission), superimposed along the line of sight. The wide-field image centered on the SNR G55.7+3.4 also demonstrates the excellent wide-field wide-band imaging capability of the EVLA.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of spectral entanglement in polarization-entanglement swapping and type-I fusion gates

We examine how spectral entanglement in polarization-entangled photon states generated from bulk-crystal, spontaneous parametric down-conversion affects the success of entanglement swapping and type-I fusion gates. We quantify the success of the entanglement swapping and fusion gates by calculating the bipartite concurrence and residual tangle, respectively, in terms of the joint spectral probability amplitudes of the initial broad-bandwidth polarization-entangled states. We find that both polarization-entanglement measures depend strongly on the initial spectral entanglement, as well as on the configuration of the independent sources. Specifically, when spectral differences correlate with polarization, the optimal source configuration is different for the two protocols. We conclude that this distinction is founded in how the underlying Bell-state measurement and quantum-erasure techniques respond differently to distinguishing spectral information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Eliminating spectral distinguishability in ultrafast spontaneous parametric down-conversion

Generation of polarization-entangled photon pairs with a precise timing through down-conversion of femtosecond pulses is often faced with a degraded polarization entanglement quality. In a previous experiment, we have shown that this degradation is induced by spectral distinguishability between the two decay paths, in accordance with theoretical predictions. Here, we present an experimental study of the spectral compensation scheme proposed and first implemented by Kim and Grice [J. Mod. Opt. 49, 2309 (2002)]. By measuring the joint spectral properties of the polarization correlations of the photon pairs, we show that the spectral distinguishability between the down-converted components is eliminated. This scheme results in a polarization visibility of 97.9{+-}0.5% without any spectral filtering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Discrete spectral incoherent solitons in nonlinear media with noninstantaneous response

We show theoretically that nonlinear optical media characterized by a finite response time may support the existence of discrete spectral incoherent solitons. The structure of the soliton consists of three incoherent spectral bands that propagate in frequency space toward the low-frequency components in a discrete fashion and with a constant velocity. Discrete spectral incoherent solitons do not exhibit a confinement in the space-time domain, but exclusively in the frequency domain. The kinetic theory describes in detail all the essential properties of discrete spectral incoherent solitons: A quantitative agreement has been obtained between simulations of the kinetic equation and the nonlinear Schroedinger equation. Discrete spectral incoherent solitons may be supported in both the normal dispersion regime or the anomalous dispersion regime. These incoherent structures find their origin in the causality condition inherent to the nonlinear response function of the material. Considering the concrete example of the Raman effect, we show that discrete incoherent solitons may be spontaneously generated through the process of supercontinuum generation in photonic crystal fibers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Semiclassical analysis of spectral singularities and their applications in optics

Motivated by possible applications of spectral singularities in optics, we develop a semiclassical method of computing spectral singularities. We use this method to examine the spectral singularities of a planar slab gain medium whose gain coefficient varies due to the exponential decay of the intensity of the pumping beam inside the medium. For both singly and doublypumped samples, we obtain universal upper bounds on the decay constant beyond which no lasing occurs. Furthermore, we show that the dependence of the wavelength of the spectral singularities on the value of the decay constant is extremely mild. This is an indication of the stability of optical spectral singularities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectral Singularities of Complex Scattering Potentials and Infinite Reflection and Transmission Coefficients at Real Energies

Spectral singularities are spectral points that spoil the completeness of the eigenfunctions of certain non-Hermitian Hamiltonian operators. We identify spectral singularities of complex scattering potentials with the real energies at which the reflection and transmission coefficients tend to infinity, i.e., they correspond to resonances having a zero width. We show that a waveguide modeled using such a potential operates like a resonator at the frequencies of spectral singularities. As a concrete example, we explore the spectral singularities of an imaginary PT-symmetric barrier potential and demonstrate the above resonance phenomenon for a certain electromagnetic waveguide.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Raman spectroscopy of thermally perturbed carbon fibers: Discriminating spectral responses of modulus classes and defect types

The mechanical strength properties of carbon fibers are generally thought to be correlated with the presence of underlying atomic-level defects. These defects serve to break the underlying translational symmetry of the graphitic or graphene subunits of the fiber construction, resulting in the emergence of new Raman-active spectral features. However, historical attempts to classify the precise origin of defect contributions to the Raman spectra have been challenging because of indistinct and overlapping features in the carbon fiber Raman spectra. Further, while substantial research exists on high-temperature exposure in inert atmospheres for carbon fiber composites, comparatively less addresses microscale behaviors and Raman spectral alterations to monofilament carbon fibers exposed to high-temperature atmospheric environments. Here, we report Raman spectral responses of nine commercially available high-performance, polyacrylonitrile-based carbon fibers exposed to various atmospheric heat treatments. In this work, we introduce a model-independent characterization method, the integrated absolute difference, to quantify the spectral responses to heat treatment of different fiber modulus classes. We combine this new method with a newly reported strategy to standardize spectral fitting for carbon fibers. With this approach, we show that atomic-scale defects in the underlying fiber microstructure manifest in measurably distinct manners and have distinct responses to thermal perturbation. These combined approaches may lay the foundation for disentangling contributions from specific defects in the Raman spectra of carbon fibers.

36 MATERIALS SCIENCE↗

Tailoring spectral properties for entangled photon generation

The linear intensity scaling of entangled two-photon absorption (ETPA) offers a fundamental mechanism to enable nonlinear optical spectroscopy and microscopy under a substantially lower excitation power than is currently feasible. However, the long data acquisition time and low signal-to-noise ratio in reported ETPA-based spectroscopic and microscopic studies prevent its widespread application. To gain the full potential of this novel quantum light approach, it is essential to optimize entangled photon generation for significantly enhanced ETPA responses. Here, we report a new quantum light source by combining entangled photon generation with free-space femtosecond pump-pulse shaping. Here, through measurements of singles and coincidence counts by varying the patterns applied to a spatial light modulator to control the spectral widths of the pump pulses, we reveal strong dependence of the singles and coincidence count rates as well as their ratios on the spectral widths of pump pulses. An optimal spectral width for the highest ratios between the coincidence photon and the signal or idler photon count rates is also determined. Identification of such optimal spectral widths for entangled photon generation in the presence of postgeneration spectral selection makes this quantum light source a promising choice for ETPA-based spectroscopy and imaging.

Photon pairs & parametric down-conversion↗

Optimal spectral resolution for solids and liquids using FT and other infrared spectrometers: How much resolution do you really need?

In this study we investigate the possibility of using spectral resolutions for infrared measurements of solids and liquids that are not powers of two, e.g. are not at 1, 2, 4, 8, or 16 cm-1 resolution. In almost all reported literature of the last fifty years the resolution used to record for a Fourier transform infrared spectrum has been a power of two. This stems from the fact that 1) the Cooley-Tukey algorithm used to compute such a transform was constructed to use only powers of two and was also driven by 2) the fact that the computing horsepower required to compute the Fourier transform increases as N?log?_2 (N), where N is the number of points in the interferogram (spectrum). For typical spectra, however, the CPU time is no longer a consideration. Our study is based on both liquid and solid spectra, all of which were recorded at 2 cm-1 resolution. There were at total of 70 solids spectra representing 2,472 spectral peaks and 61 liquids spectra (1,765 spectral peaks), each peak being inspected for being singlet / multiplet in nature. Of the 1,765 liquid bands examined, only 27 had widths less than 5 cm-1. Of the 2,472 solid bands examined, only 39 peaks have widths less than 5 cm-1. For liquids, the mean peak width is 24.7 cm-1 but the median peak width is 13.7 cm-1, and, similarly, for solids, the mean peak width is 22.2 cm-1 but the median peak width is 11.2 cm-1. In both cases, solids and liquids, a skewed peak widths distribution was observed, the peak of the distribution representing narrower bands in the 7 to 9 cm-1 FWHM range but displaying a long tail to the very broad bands, with some displaying spectral widths of 100 cm-1 or more. Because one of the most important criteria for successful instrumental design in IR spectroscopy is the spectral resolution, the data were further analyzed showing that a value to resolve 95% of all bands is 5.7 cm-1 for liquids and 5.3 cm-1 for solids; such a resolution would capture the native linewidth (no instrumental broadening) of 95% of all the solids and liquid bands, respectively. Based on the present results we suggest that, when accounting only for intrinsic linewidths an optimized resolution of 6.0 cm-1 will capture 91% of all condensed-phase bands for IR detection of chemical, mineral, and biological materials.

Forland, Brenda M.↗

Contrast-enhanced spectral mammography with a photon-counting detector

Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. Methods: A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. Results: Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another {approx}70%-90% improvement was found to be within reach for an optimized system. Conclusions: Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

TU-CD-207-01: Characterization of Breast Tissue Composition Using Spectral Mammography

Purpose: To investigate the feasibility of characterizing the chemical composition of breast tissue, in terms of water and lipid, by using spectral mammography in simulation and postmortem studies. Methods: Analytical simulations were performed to obtain low- and high-energy signals of breast tissue based on previously reported water, lipid, and protein contents. Dual-energy decomposition was used to characterize the simulated breast tissue into water and lipid basis materials and the measured water density was compared to the known value. In experimental studies, postmortem breasts were imaged with a spectral mammography system based on a scanning multi-slit Si strip photon-counting detector. Low- and high-energy images were acquired simultaneously from a single exposure by sorting the recorded photons into the corresponding energy bins. Dual-energy material decomposition of the low- and high-energy images yielded individual pixel measurements of breast tissue composition in terms of water and lipid thicknesses. After imaging, each postmortem breast was chemically decomposed into water, lipid and protein. The water density calculated from chemical analysis was used as the reference gold standard. Correlation of the water density measurements between spectral mammography and chemical analysis was analyzed using linear regression. Results: Both simulation and postmortem studies showed good linear correlation between the decomposed water thickness using spectral mammography and chemical analysis. The slope of the linear fitting function in the simulation and postmortem studies were 1.15 and 1.21, respectively. Conclusion: The results indicate that breast tissue composition, in terms of water and lipid, can be accurately measured using spectral mammography. Quantitative breast tissue composition can potentially be used to stratify patients according to their breast cancer risk.

60 APPLIED LIFE SCIENCES↗