Radiation damage effects in a surface barrier detector after irradiation by 4.5 MeV alpha particles
Alpha particles radiation damage effects in silicon surface barrier detector
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Alpha particles radiation damage effects in silicon surface barrier detector
A neutral particle detector using field ionization and liquid-nitrogen-cooled solid state detectors has been developed to investigate the pulse height defect of low energy He(+) ions in silicon. The field ionization tip is fabricated from a short length of tungsten wire; a typical detector is of the surface-barrier Si type with a thin Au window and low capacitance (about 15 pF); the assembly is mounted in a cylindrical vacuum chamber which is pumped to about 10 to the -6th torr. As an example, pulse height distributions for He(+) and H(+) taken at tip bias of 25.7 kV are presented. The detected energy of the H and He ions are studied as a function of the actual energies of accelerated ions, for a detector having a gold front conducting surface layer of 32 micrograms/sq cm.
Selective doping of silicon in proposed metal silicide/silicon Schottky-barrier infrared photodetector increases maximum detectable wavelength. Stacking layers to form multiple Schottky barriers increases quantum efficiency of detector. Detectors of new type enhance capabilities of far-infrared imaging arrays. Grows by molecular-beam epitaxy on silicon waferscontaining very-large-scale integrated circuits. Imaging arrays of detectors made in monolithic units with image-preprocessing circuitry.
Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide detector with a metal-intrinsic-metal structure has been fabricated for particle tracking. The detector was tested using radioactive sources and a high energy proton beam at Fermi National Accelerator Laboratory. In addition to its simplistic design and fabrication process, the indium phosphide particle detector showed a very fast response time of hundreds of picoseconds for the 120 GeV protons, which are comparable to the ultra-fast silicon detectors. This fast-timing response is attributed to the high electron mobility of indium phosphide. Such material properties can be leveraged to build novel detectors with superlative performance.
State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.
Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE $v$ NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. Here, in this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm 2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68 ± 0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.
The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.
Abstract not provided.
Technique is developed at Langley Research Center for mounting pyroelectric detector arrays on silicon integrated circuits. Procedure incorporates normal silicon integrated-circuit technology to form quasi-free mounts for detector arrays. Advantages of technique include lower cost, better image registration, and improved reliability.
Nuclear radiation detectors with volumes of approximately 1 cu cm was fabricated from single crystals of germanium-silicon alloy containing as much as 20 weight percent germanium. The properties of these detectors were investigated and will be discussed. Tests reveal that the gamma ray photoelectric peak efficiency of an alloy detector with only 12 weight percent germanium is approximately 4 times that of a silicon detector of equal volume. The room temperature roomure appears to be a good possibility. Storage for long periods at room temperature does not seem to adversely affect these devices. The results of preliminary radiation damage experiments suggest that the alloy detectors possess a radiation damage resistance far greater than that of silicon.
The tracking and imaging gamma ray experiment (TIGRE) Compton telescope concept can provide an angular resolution of a few arcmin, an energy resolution of a few keV and high sensitivity, while providing the wide field of view necessary for surveying and monitoring observations. Silicon and CdZnTe strip detectors are used to detect Compton pair events and determine their incident directions and energies. Above 400 keV, Compton recoil electrons are tracked through successive layers of thin silicon strip detectors. Compton scattered photons are detected with CdZnTe strip detectors. Pair electrons and positrons are tracked to provide high sensitivity observations in the 10 to 100 MeV range. Polarization studies are performed with large angle Compton scatter events. The TIGRE concept and development status are described.
The paper discusses the University of Minnesota experiment on ATS-6 designed to study the origin and dynamics of high-energy electrons and protons in the outer radiation belt and in the near-earth plasma sheet. The experiment consists of two nearly identical detector assemblies, each of which is a magnetic spectrometer containing four gold-silicon surface barrier detectors. The instrument provides a clean separation between protons and electrons by the combination of pulse height analysis and magnetic deflection.
Sub-band absorption at 1550 nm has been demonstrated and characterized on silicon Geiger mode detectors which normally would be expected to have no response at this wavelength. We compare responsivity measurements to singlephoton absorption for wavelengths slightly above the bandgap wavelength of silicon (approx. 1100 microns). One application for this low efficiency sub-band absorption is in deep space optical communication systems where it is desirable to track a 1030 nm uplink beacon on the same flight terminal detector array that monitors a 1550 nm downlink signal for pointingcontrol. The currently observed absorption at 1550 nm provides 60-70 dB of isolation compared to the response at 1064 nm, which is desirable to avoid saturation of the detector by scattered light from the downlink laser.
This paper explores the potential of AstroPix, a project to develop Complementary Metal Oxide Semiconductor (CMOS) pixels for the next generation of space-based high-energy astrophysics experiments. Multimessenger astrophysics is a rapidly developing field whose upcoming missions need support from new detector technology such as AstroPix. ATLASPix, a monolithic silicon detector optimized for the ATLAS particle detector at CERN, is the beginning of the larger AstroPix project. Energy resolution is a driving parameter in the reconstruction of gamma-ray events, and therefore the characterization of ATLASPix energy resolution is the focus of this paper. The intrinsic energy resolution of the detector exceeded our baseline requirements of 10% at 60 keV. The digital output of ATLASPix results in energy resolutions insufficient to advance gamma-ray astronomy. However, the results from the intrinsic energy resolution indicate the digital capability of the detector can be redesigned, and the next generation of pixels for the larger AstroPix project have already been constructed. Iterations of AstroPix-type pixels are an exciting new technology candidate to support new space-based missions.
Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.
The Global Atmospheric Backscatter Experiment (GLOBE) Mission, using the NASA DC-8 aircraft platform, is designed to provide the magnitude and statistical distribution of atmospheric backscatter cross section at lidar operating wavelengths. This is a fundamental parameter required for the Doppler lidar proposed to be used on a spacecraft platform for global wind field measurements. The prime measurements will be made by a CO2 lidar instrument in the 9 to 10 micron range. These measurements will be complemented with the Goddard YAG Aerosol Lidar (YAL) data in two wavelengths, 0.532 and 1.06 micron, in the visible and near-infrared. The YAL, is being designed to utilize as much existing hardware, as feasible, to minimize cost and reduce implementation time. The laser, energy monitor, telescope and detector package will be mounted on an optical breadboard. The optical breadboard is mounted through isolation mounts between two low boy racks. The detector package will utilize a photomultiplier tube for the 0.532 micron channel and a silicon avalanche photo detector (APD) for the 1.06 micron channel.
A process for n-type (electron-donor) delta doping has shown promise as a means of modifying back-illuminated image detectors made from n-doped high-purity silicon to enable them to detect high-energy photons (ultraviolet and x-rays) and low-energy charged particles (electrons and ions). This process is applicable to imaging detectors of several types, including charge-coupled devices, hybrid devices, and complementary metal oxide/semiconductor detector arrays. Delta doping is so named because its density-vs.-depth characteristic is reminiscent of the Dirac delta function (impulse function): the dopant is highly concentrated in a very thin layer. Preferably, the dopant is concentrated in one or at most two atomic layers in a crystal plane and, therefore, delta doping is also known as atomic-plane doping. The use of doping to enable detection of high-energy photons and low-energy particles was reported in several prior NASA Tech Briefs articles. As described in more detail in those articles, the main benefit afforded by delta doping of a back-illuminated silicon detector is to eliminate a "dead" layer at the back surface of the silicon wherein high-energy photons and low-energy particles are absorbed without detection. An additional benefit is that the delta-doped layer can serve as a back-side electrical contact. Delta doping of p-type silicon detectors is well established. The development of the present process addresses concerns specific to the delta doping of high-purity silicon detectors, which are typically n-type. The present process involves relatively low temperatures, is fully compatible with other processes used to fabricate the detectors, and does not entail interruption of those processes. Indeed, this process can be the last stage in the fabrication of an imaging detector that has, in all other respects, already been fully processed, including metallized. This process includes molecular-beam epitaxy (MBE) for deposition of three layers, including metallization. The success of the process depends on accurate temperature control, surface treatment, growth of high-quality crystalline silicon, and precise control of thicknesses of layers. MBE affords the necessary nanometer- scale control of the placement of atoms for delta doping. More specifically, the process consists of MBE deposition of a thin silicon buffer layer, the n-type delta doping layer, and a thin silicon cap layer. The n dopant selected for initial experiments was antimony, but other n dopants as (phosphorus or arsenic) could be used. All n-type dopants in silicon tend to surface-segregate during growth, leading to a broadened dopant-concentration- versus-depth profile. In order to keep the profile as narrow as possible, the substrate temperature is held below 300 C during deposition of the silicon cap layer onto the antimony delta layer. The deposition of silicon includes a silicon- surface-preparation step, involving H-termination, that enables the growth of high-quality crystalline silicon at the relatively low temperature with close to full electrical activation of donors in the surface layer.
The status of development and characterization tests of integrated infrared detector array technology for astronomy applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, with hybrid silicon multiplexers. Laboratory test results and successful astronomy imagery have established the usefulness of integrated arrays in low-background astronomy applications.