Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Low-threshold response of a scintillating xenon bubble chamber to nuclear and electronic recoils

A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ∼4 keV showed sensitivity to ∼20 keV nuclear recoils with no observable bubble nucleation by 𝛾-ray interactions. Here, this paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ∼1 keV nuclear recoils while remaining insensitive to bubble nucleation by 𝛾-rays. A data-driven calibration of the chamber’s nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by 𝛾-ray-induced Auger cascades, with a limit of <1.1 ×10 −6 set at 0.50 keV, the lowest thermodynamic threshold explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Onset of Fogging and Degradation in Polyvinyl Toluene-Based Scintillators

Plastic-based gamma-ray detector materials such as polyvinyl toluene (PVT) occasionally suffer from loss of optical light transmission due to internal defects or “fogging” when exposed to some environmental conditions over time. Fogging results in reduced scintillation light propagated to the photomultiplier tube for collection. Investigations of the physical cause of these defects and their associated environmental conditions are ongoing. The goal of this work was to characterize the signs and effects of fogging over a simulated 22-year lifespan of the PVT in outdoor environments. Here, two potential mitigation methods were also evaluated, and one successfully mitigated the phenomena.

36 MATERIALS SCIENCE↗

Scintillation light in SBND: simulation, reconstruction, and expected performance of the photon detection system

SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its design is a dual readout concept combining a system of 120 photomultiplier tubes, used for triggering, with a system of 192 X-ARAPUCA devices, located behind the anode wire planes. Furthermore, covering the cathode plane with highly-reflective panels coated with a wavelength-shifting compound recovers part of the light emitted towards the cathode, where no optical detectors exist. We show how this new design provides a high light yield and a more uniform detection efficiency, an excellent timing resolution and an independent 3D-position reconstruction using only the scintillation light. Finally, the whole reconstruction chain is applied to recover the temporal structure of the beam spill, which is resolved with a resolution on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]↗

Scintillators

As concerns about the illicit movement of radioactive materials across international borders increase, so too has the need for increased protection of those borders both foreign and domestic. The challenge is not only to detect hidden radioactive materials, but also to distinguish them from legitimate radionuclides such as radio-pharmaceuticals that are often transported across borders and shipped throughout a country. With more than 600 U.S. border sites to protect, screening imported radioactive material requires a careful balance of high throughput and high search efficiency. However, these requirements are difficult to meet as rapid screening operations leave less time for radiation detectors to efficiently evaluate materials. In support of border security, Sandia developed organic glass scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Cryogenic Scintillation Neutrino Detector at the Spallation Neutron Source

We successfully verified in the following three aspects the feasibility of using a cryogenic scintillating crystal-based neutrino detector at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, for the detection of low-mass dark matter particles and non-standard neutrino interactions (NSIs), as part of the detector R&D effort of the COHERENT experiment. First, we demonstrated the possibility of using silicon photomultipliers (SiPMs) at cryogenic temperatures to replace traditional photomultiplier tubes (PMTs) as light sensors. Second, we verified that the high light yield of undoped CsI crystals measured above 13 keVee at 77 K still holds down to 5.9 keVee. Third, we successfully measured nuclear quenching factor of undoped cryogenic CsI at the Triangle Universities Nuclear Laboratory with the help from our Duke collaborators. The first achievement resulted in a publication in European Physics Journal C. The second resulted in an arXiv pre-print, which is under journal review. The last one indicates that the performance of the proposed detector may be better than what was assumed in the literature. The analysis is in the final stage and will result in another journal publication. In addition, two graduate students involved in this project graduated with master’s degrees during the project period. Both decided to continue their research as PhD students. One open-source data analysis code package was created and is publicly available on GitHub. A set of tutorials about Monte Carlo simulation of radiation interacting with detectors were created on YouTube, receiving more than 100,000 views.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Muon Beam Diagnostics - Scintillating Fiber Profile Monitor (SFPM)

The MeV Test Area (MTA) houses the 400 MeV H^− Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Multiple Phase Screen Scintillation Code Execution and Examples

The phenomenon of random fluctuations in the amplitude and phase of received transionospheric radio frequency (RF) signals is well known and documented. For wide band signals, sometimes a set of frequencies in the the band or even the whole band can suffer degradation or complete drop out at the receiver. The former is known as frequency selective scintillation where only a fraction of the signal bandwidth is affected, whereas the latter is known as flat fading.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)↗

Performance and long-term stability of the ICARUS-T600 scintillation light detection system

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \sim 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. Long-term behavior of PMT gains and timing resolution, demonstrate the robustness and reliability of the ICARUS scintillation light detection system and provide valuable input for the design and operation of future large-scale liquid argon detectors.

Raselli, Gian Luca [INFN, Perugia] (ORCID:00000002↗