Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Observation of stacking engineered magnetic phase transitions within moiré supercells of twisted van der Waals magnets

Abstract Recent demonstrations of moiré magnetism, featuring exotic phases with noncollinear spin order in the twisted van der Waals (vdW) magnet chromium triiodide CrI 3 , have highlighted the potential of twist engineering of magnetic (vdW) materials. However, the local magnetic interactions, spin dynamics, and magnetic phase transitions within and across individual moiré supercells remain elusive. Taking advantage of a scanning single-spin magnetometry platform, here we report observation of two distinct magnetic phase transitions with separate critical temperatures within a moiré supercell of small-angle twisted double trilayer CrI 3 . By measuring temperature-dependent spin fluctuations at the coexisting ferromagnetic and antiferromagnetic regions in twisted CrI 3 , we explicitly show that the Curie temperature of the ferromagnetic state is higher than the Néel temperature of the antiferromagnetic one by ~10 K. Our mean-field calculations attribute such a spatial and thermodynamic phase separation to the stacking order modulated interlayer exchange coupling at the twisted interface of moiré superlattices.

36 MATERIALS SCIENCE↗

Nanofabrication of synthetic nanoporous geomaterials: from nanoscale-resolution 3D imaging to nano-3D-printed digital (shale) rock

Abstract Advances in imaging have made it possible to view nanometer and sub-nanometer structures that are either synthesized or that occur naturally. It is believed that fluid dynamic and thermodynamic behavior differ significantly at these scales from the bulk. From a materials perspective, it is important to be able to create complex structures at the nanometer scale, reproducibly, so that the fluid behavior may be studied. New advances in nanoscale-resolution 3D-printing offer opportunities to achieve this goal. In particular, additive manufacturing with two-photon polymerization allows creation of intricate structures. Using this technology, a creation of the first nano-3D-printed digital (shale) rock is reported. In this paper, focused ion beam-scanning electron microscopy (FIB-SEM) nano-tomography image dataset was used to reconstruct a high-resolution digital rock 3D model of a Marcellus Shale rock sample. Porosity of this 3D model has been characterized and its connected/effective pore system has been extracted and nano-3D-printed. The workflow of creating this novel nano-3D-printed digital rock 3D model is described in this paper.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Actively stabilized optical fiber interferometry technique for online/in-process surface measurement

In this paper, we report the recent progress in optical-beam scanning fiber interferometry for potential online nanoscale surface measurement based on the previous research. It attempts to generate a robust and miniature measurement device for future development into a multiprobe array measurement system. In this research, both fiber-optic-interferometry and the wavelength-division-multiplexing techniques have been used, so that the optical probe and the optical interferometer are well spaced and fast surface scanning can be carried out, allowing flexibility for online measurement. In addition, this system provides a self-reference signal to stabilize the optical detection with high common-mode noise suppression by adopting an active phase tracking and stabilization technique. Low-frequency noise was significantly reduced compared with unstabilized result. The measurement of a sample surface shows an attained repeatability of 3.3 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase diagram of CeSb 2 from magnetostriction and magnetization measurements: Evidence for ferrimagnetic and antiferromagnetic states

Cerium diantimonide (CeSb 2 ) is one of a family of rare-earth-based magnetic materials that exhibit metamagnetism, enabling control of the magnetic ground state through an applied magnetic field. At low temperatures, CeSb 2 hosts a rich phase diagram with multiple magnetically ordered phases for many of which the order parameter is only poorly understood. In this work, we report a study of its metamagnetic properties by scanning tunneling microscopy (STM) and magnetization measurements. We use STM measurements to characterize the sample magnetostriction with subpicometer resolution from magnetic field and temperature sweeps. This allows us to directly assess the bulk phase diagram as a function of field and temperature and relate spectroscopic features from tunneling spectroscopy to bulk phases. Our magnetostriction and magnetization measurements indicate that the low-temperature ground state at zero field is ferrimagnetic. Quasiparticle interference mapping shows evidence for a reconstruction of the electronic structure close to the Fermi energy upon entering the magnetically ordered phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization and operation optimization of large aperture optical interferometers using binary pseudorandom array test standards

Recently, a technique for calibration of the Modulation Transfer Function (MTF) of a broad variety of metrology instrumentation has been established. The technique is based on test samples structured according to binary pseudorandom (BPR) one-dimensional sequences and two-dimensional arrays. The inherent power spectral density of BPR gratings and arrays, has a deterministic white-noise-like character that allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: Functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments working with support of the U.S. Department of Energy on industrialization of the technique. The goal is to develop affordable BPR test samples, application procedures, and data processing software, suitable for thorough characterization of optical interferometers and microscopes, as well as x-ray, electron (scanning and transmission), and atomic force microscopes. We report on the development of BPR array test samples optimized for advanced characterization (including the instrumental MTF and aberrations) and operation optimization of large aperture optical interferometers. We describe the sample fabrication process and tests to verify the compliance to desired surface topography. The data acquisition and analysis procedures for application of the technique for precise focusing of Fizeau interferometer are discussed in detail.

Yashchuk, VV↗

Coldstream 1MH Well

Computed tomography scans and core log data obtained at the National Energy Technology Laboratory. Complimentary to 'Computed Tomography Scanning and Geophysical Measurements of Core from the Coldstream 1MH Well" Technical Report Series, 2018

CT Scans↗

Experimental Evaluation of Deformation and Fracture Mechanisms in Highly Irradiated Austenitic Steels

The present report documents recent experimental results of analysis using scanning electron microscopy/electron backscatter diffraction (SEM-EBSD) of plastic deformation mechanisms and strain localization phenomena in austenitic steels irradiated by neutrons. Experiments were performed with specimens irradiated to 125 dpa and, additionally, with specimens that experienced radiation-induced swelling up to 3%. Section 1 briefly analyzes the deformation localization in irradiated steels and its consequences on the material performance. The section describes the advantages and importance of the SEM-EBSD approach combined with in situ mechanical testing capability. Section 2 briefly introduces the experimental tools and methods (i.e., SEM/EBSD in situ tensile frame, electric discharge machine to manufacture irradiated specimens) and describes the investigated materials (i.e., element composition, irradiation conditions, and general microstructure). Section 3 describes the key experimental results and provides a brief analysis and comparison with the datasets obtained earlier within the same task (i.e., low-dose specimens). The discussion focuses on EBSD microstructure maps with strain localization features, misorientation evolution as a function of strain, and observed deformation mechanisms. Section 4 evaluates data collected in recent years on highly irradiated steel and estimates the possible misorientation evolution under irradiation. The section introduces and discusses the concept of in-service-induced damage as an irradiation-assisted stress-corrosion cracking precursor. Section 5 summarizes the work performed. As expected, the present work results are beneficial for exploring and understanding degradation mechanisms in highly irradiated in-core materials found in light water reactors after long-term in-service life.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Planetary astronomy program

A program was developed in which asteroids and two planets, namely, Saturn and Uranus, were investigated. This included: (1) asteroid spectrophotometry; (2) the nature of the Trojan asteroids; (3) an investigation to determine asteroid masses; (4) the photometry, structure, and dynamics of the rings surrounding the planet Saturn; and (5) aerosol distribution in the atmosphere of Uranus. Plans were finalized to obtain observations of the nucleus of the dying comet P/Arend-Rigaux. Further work was accomplished in asteroid data reduction. Data were entered into the TRIAD data file and a program generated classifications for over 560 different asteroids. A photoelectric area scanner was used to obtain UBV scans of the disk of the planet Saturn on several winter and spring nights in 1977. Intensity profiles show pronounced limb brightening in U, moderate limb brightening in B, and limb darkening in V. Narrow band photoelectric area-scanning photometry of the Uranus disk is also reported. Results are given.

Source record↗

Coupling apparatus for ultrasonic medical diagnostic system

An apparatus for the ultrasonic scanning of a breast or other tissue is reported that contains a cavity for receiving the breast, a vacuum for drawing the breast into intimate contact with the walls of the cavity, and transducers coupled through a fluid to the cavity to transmit sound waves through the breast. Each transducer lies at the end of a tapered chamber which has flexible walls and which is filled with fluid, so that the transducer can be moved in a raster pattern while the chamber walls flex accordingly, with sound transmission always occurring through the fluid.

Frazer, R. E.↗

Positions and identifications for galactic X-ray sources 2A1822-371 and 2S1254-690

Precise positions and optical identifications for the galactic X-ray sources 2A1822-371 (4U 1822-37) and 2S 1254-690 (4U 1254-69) were obtained by used of a described scanning modulation collimator on HEAO 1 and are reported. Neither is thought to be substantially reddened since both show strong ultraviolet excesses and are located at a relatively high galactic latitude. The distance of 4U 1254-69 is estimated to be approximately 10 kpc.

Griffiths, R. E.↗

Search with Copernicus for ultraviolet emission lines in the planetary nebula NGC 3242

The high-excitation planetary nebula NGC 3242 has been observed with the ultraviolet telescope-spectrometer aboard Copernicus. Wavelength intervals corresponding to the emission lines of O VI at 1032 A, He II at 1085 A, Si III at 1206 A, and N V at 1239 A have been scanned. Upper limits to the observed fluxes are reported and compared with predicted emission-line fluxes from this object.

Schwartz, R. D.↗

Polarized-Cathodoluminescence Study Of Stress In GaAs/Si

Report describes experiments in which linearly polarized cathodoluminesce scanning electron microscopy, in both imaging and spectroscopic forms, used to analyze spatial variations in stress tensors in specimens of GaAs/Si. Specimens fabricated by atmospheric-pressure metallo-organic chemical vapor deposition of GaAs to thickness of 4 micrometers on Si substrates. Combination of mismatch between Si and GaAs crystal lattices and differential thermal contraction of materials from deposition temperature (700 degrees C) to room temperature gives rise to stresses in GaAs layer. Experiments conducted to contribute to understanding of effects of these stresses and ramifications thereof for fabrication of electronic devices in GaAs/Si system.

Rich, Daniel H.↗

Effects of JP-8 Jet Fuel on Homeostasis of Clone 9 Rat Liver Cells

Chronic exposure to JP-8 and other kerosene-based petroleum distillates has been associated with hepatic, renal, neurologic, pulmonary, and immune toxicity. However, the effects of kerosene-type jet fuels on cellular homeostasis hitherto have not been reported. Fluorescence imaging using a Meridian Ultima laser scanning fluorescence microscope was used to evaluate the effect of JP-8 jet fuel on a communication competent rat liver cell line. Several endpoints of cellular function were measured including gap junctional intercellular communication (GJIC), mitochondrial and plasma membrane potential (MMP and PMP, respectively), intracellular glutathione (GSH) concentration, glutathione-S-transferase (GST) activity, and reactive oxygen species (ROS) generation. Cells were treated with JP-8 (0.01 to 2% in ethanol (EtOH)) for the following time points: 1 h, 24 h, 48 h, and analysis immediately after addition of jet fuel. GJIC analyzed directly after addition of 1% JP-8 was reduced 4.9-fold relative to EtOH-dosed control groups and further reduction (12.6-fold) was observed in cells treated for 1 h. Moreover, GJIC was not recoverable in cells treated with 1% JP-8 for 1 h and subsequently washed and incubated in fresh medium for 1 h. Significant changes in GSH content and GST activity were observed in cells analyzed directly after addition of 1% JP-8. GSH content increased in cells treated for 1 h with less than 2% JP-8 whereas treatment with 2% JP-8 for 1 h resulted in a 50% reduction in intracellular GSH relative to EtOH-dosed controls. Cells treated with 1% JP-8 for 48 h exhibited changes in GSH levels. However, higher JP-8 concentrations exhibited more pronounced changes in GSH and GST, which led to suppression of GSH synthesis. ROS increased in a dose-responsive fashion at JP-8 concentrations up to 1%, but decreased to 80% of control values at 2% and 3% JP-8. A 25% reduction in PMP was observed in cells treated for 1 h with 1% JP-8. In contrast, cells treated for 48 h with 2% JP-8 exhibited a 25% increase when compared to control. No significant changes were noted in the 0.01 and 1% treatment groups. Moreover, no significant changes were observed in MMP or intracellular calcium concentrations in cells treated with 0.01 to 2% JP-8 for up to 48 h. In summary, the most significant effects observed in the present study which may contribute to the toxicity of JP-8 jet fuel in cultured rat liver cells include effects on GJIC, ROS production, and GSH depletion at high (i.e., greater than 2%) JP-8 concentrations.

Wilson, C. L.↗

Advanced Three-Dimensional Display System

A desktop-scale, computer-controlled display system, initially developed for NASA and now known as the VolumeViewer(TradeMark), generates three-dimensional (3D) images of 3D objects in a display volume. This system differs fundamentally from stereoscopic and holographic display systems: The images generated by this system are truly 3D in that they can be viewed from almost any angle, without the aid of special eyeglasses. It is possible to walk around the system while gazing at its display volume to see a displayed object from a changing perspective, and multiple observers standing at different positions around the display can view the object simultaneously from their individual perspectives, as though the displayed object were a real 3D object. At the time of writing this article, only partial information on the design and principle of operation of the system was available. It is known that the system includes a high-speed, silicon-backplane, ferroelectric-liquid-crystal spatial light modulator (SLM), multiple high-power lasers for projecting images in multiple colors, a rotating helix that serves as a moving screen for displaying voxels [volume cells or volume elements, in analogy to pixels (picture cells or picture elements) in two-dimensional (2D) images], and a host computer. The rotating helix and its motor drive are the only moving parts. Under control by the host computer, a stream of 2D image patterns is generated on the SLM and projected through optics onto the surface of the rotating helix. The system utilizes a parallel pixel/voxel-addressing scheme: All the pixels of the 2D pattern on the SLM are addressed simultaneously by laser beams. This parallel addressing scheme overcomes the difficulty of achieving both high resolution and a high frame rate in a raster scanning or serial addressing scheme. It has been reported that the structure of the system is simple and easy to build, that the optical design and alignment are not difficult, and that the system can be built by use of commercial off-the-shelf products. A prototype of the system displays an image of 1,024 by 768 by 170 (=133,693,440) voxels. In future designs, the resolution could be increased. The maximum number of voxels that can be generated depends upon the spatial resolution of SLM and the speed of rotation of the helix. For example, one could use an available SLM that has 1,024 by 1,024 pixels. Incidentally, this SLM is capable of operation at a switching speed of 300,000 frames per second. Implementation of full-color displays in future versions of the system would be straightforward: One could use three SLMs for red, green, and blue, respectively, and the colors of the voxels could be automatically controlled. An optically simpler alternative would be to use a single red/green/ blue light projector and synchronize the projection of each color with the generation of patterns for that color on a single SLM.

Geng, Jason↗

Technical Note: On GAFChromic EBT-XD film and the lateral response artifact

Purpose: The new radiochromic film, GAFChromic EBT-XD, contains the same active material, lithium-10,12-pentacosadiynoate, as GAFChromic EBT3, but the crystalline form is different. This work investigates the effect of this change on the well-known lateral response artifact when EBT-XD film is digitized on a flatbed scanner. Methods: The dose response of a single production lot of EBT-XD was characterized by scanning an unexposed film plus a set of films exposed to doses between 2.5 and 50 Gy using 6 MV photons. To characterize the lateral response artifact, the authors used the unexposed film plus a subset of samples exposed to doses between 20 and 50 Gy. Digital images of these films were acquired at seven discrete lateral locations perpendicular to the scan direction on three Epson 10000XL scanners. Using measurements at the discrete lateral positions, the scanner responses were determined as a function of the lateral position of the film. From the data for each scanner, a set of coefficients were derived whereby measured response values could be corrected to remove the effects of the lateral response artifact. The EBT-XD data were analyzed as in their previous work and compared to results reported for EBT3 in that paper. Results: For films scanned in the same orientation and having equal responses, the authors found that the lateral response artifact for EBT-XD and EBT3 films was remarkably similar. For both films, the artifact increases with increased net response. However, as EBT-XD is less sensitive than EBT3, a greater exposure dose is required to reach the same net response. On this basis, the lower sensitivity of EBT-XD relative to EBT3 results in less net response change for equal exposure and a reduction in the impact of the lateral response artifact. Conclusions: The shape of the crystalline active component in EBT-XD and EBT3 does not affect the fundamental existence of the lateral response artifact when the films are digitized on flatbed scanners. Owing its lower sensitivity, EBT-XD film requires higher dose to reach the same response as EBT3, resulting in lesser impact of the lateral response artifact. For doses >10 Gy, the slopes of the EBT-XD red and green channel dose response curves are greater than the corresponding ones for EBT3. For these two reasons, the authors prefer EBT-XD for doses exceeding about 10 Gy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SOLID PHASE CHARACTERIZATION OF HEEL SAMPLES FROM TANK 241-C-110

During sluicing operations of tank 241-C-110, a significant amount of solids were unable to be retrieved. These solids (often referred to as the tank 'heel') were sampled in 2010 and chemically and mineralogically analyzed in the 222-S Laboratory. Additionally, dissolution tests were performed to identify the amount of undissolvable material after using multiple water contacts. This report covers the solid phase characterization of six samples from these tests using scanning electron microscopy, polarized light microscopy, and X-ray diffraction. The chemical analyses, particle size distribution analysis, and dissolution test results are reported separately. Two of the samples were from composites created from as-received material - Composite A and Composite B. The main phase in these samples was sodium-fluoride-phosphate hydrate (natrophosphate) - in the X-ray diffraction spectra, this phase was the only phase identifiable. Polarized light microscopy showed the presence of minor amounts of gibbsite and other phases. These phases were identified by scanning electron microscopy - energy dispersive X-ray spectroscopy as sodium aluminosilicates, sodium diuranate, and sodium strontium phosphate hydrate (nastrophite) crystals. The natrophosphate crystals in the scanning electron microscopy analysis showed a variety of erosive and dissolution features from perfectly shaped octahedral to well-rounded appearance. Two samples were from water-washed Composites A and B, with no change in mineralogy compared to the as-received samples. This is not surprising, since the water wash had only a short period of water contact with the material as opposed to the water dissolution tests. The last two samples were residual solids from the water dissolution tests. These tests included multiple additions of water at 15 C and 45 C. The samples were sieved to separate a coarser fraction of > 710 {mu}m and a finer fraction of < 710 {mu}m. These two fractions were analyzed separately. The coarser fraction contained mostly gibbsite with minor amounts of sodium aluminosilicates (cancrinite) and bismuth aluminum-rich phases. The finer fraction was mostly composed of gibbsite, the sodium alumino silicate phase, cancrinite, and a poorly crystalline to non-crystalline phase containing varying amounts of iron, bismuth, aluminum, and phosphorus.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT

Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length was used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.

60 APPLIED LIFE SCIENCES↗

Spatial Resolution of a microCT Scanner

We have measured the spatial resolution of the 450 kV test-bed microCT scanner. We have also modeled the resolution analytically. The model and measurement show correspondence within 5%. Our measurement method was to use a thin tungsten wire to act as an impulse function. Therefore, the image is the impulse response, also called the point spread function (PSF) of the system. The Fourier transform (FT) of the impulse response is the modulation transfer function (MTF) of the system. We report the MTF here. By moving the wire at different positions in the scan field of view (FOV), we can measure MTF at different positions in the FOV. Since our imaging system is radially symmetric, we report MTF in two directions, radial and tangential as shown in Figure 1. The radial direction is along the line from isocenter to the wire, and the tangential is perpendicular to it.

42 ENGINEERING↗