Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Three-dimensional structure of brain tissue at submicrometer resolution

Biological objects are composed of submicrometer structures such as cells and organelles that are essential for their functions. Here, we report on three-dimensional X-ray visualization of cells and organelles at resolutions up to 100 nm by imaging microtomography (micro-CT) equipped with Fresnel zone plate optics. Human cerebral tissue, fruit fly cephalic ganglia, and Escherichia coli bacteria labeled with high atomic-number elements were embedded in epoxy resin and subjected to X-ray microtomography at the BL37XU and BL47XU beamlines of the SPring-8 synchrotron radiation facility. The obtained results indicated that soft tissue structures can be visualized with the imaging microtomography.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Temporal and spectral imaging with micro-CT

Purpose: Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro-CT. Methods: The approach entails a retrospectively gated dual energy scan with optimized filters and voltages, and a series of computational operations to reconstruct the data. Projection interpolation and five-dimensional bilateral filtration (three spatial dimensions + time + energy) are used to reduce noise and artifacts associated with retrospective gating. We reconstruct separate volumes corresponding to different cardiac phases and apply a linear transformation to decompose these volumes into components representing concentrations of water and iodine. Since the resulting material images are still compromised by noise, we improve their quality in an iterative process that minimizes the discrepancy between the original acquired projections and the projections predicted by the reconstructed volumes. The values in the voxels of each of the reconstructed volumes represent the coefficients of linear combinations of basis functions over time and energy. We have implemented the reconstruction algorithm on a graphics processing unit (GPU) with CUDA. We tested the utility of the technique in simulations and applied the technique in an in vivo scan of a C57BL/6 mouse injected with blood pool contrast agent at a dose of 0.01 ml/g body weight. Postreconstruction, at each cardiac phase in the iodine images, we segmented the left ventricle and computed its volume. Using the maximum and minimum volumes in the left ventricle, we calculated the stroke volume, the ejection fraction, and the cardiac output. Results: Our proposed method produces five-dimensional volumetric images that distinguish different materials at different points in time, and can be used to segment regions containing iodinated blood and compute measures of cardiac function. Conclusions: We believe this combined spectral and temporal imaging technique will be useful for future studies of cardiopulmonary disease in small animals.

60 APPLIED LIFE SCIENCES↗

1-D profiling using highly dispersive guided waves

Corrosion is one of the industries major issues regarding the integrity of assets. Currently, inspections are conducted at regular intervals to ensure a sufficient integrity level of these assets. Cost reduction while maintaining a high level of reliability and safety of installations is a major challenge. There are many situations where the actual defect location is not accessible, e.g., a pipe support or a partially buried pipe. Guided wave tomography has been developed to reconstruct the wall thickness of steel pipes. In case of bottom of the line corrosion, i.e., a single corrosion pit, a simpler approach may be followed. Data is collected in a pitch-catch configuration at the 12 o'clock position using highly dispersive guided waves. After dispersion correction the data collapses to a short pulse, any residual dispersion indicates wall loss. The phase spectrum is used to invert for the wall thickness profile in the circumferential direction, assuming a Gaussian defect profile. The approach is evaluated on numerically simulated and on measured data. The method is intended for rapid, semi-quantitative screening of pipes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a MEMS-base Adaptive Optics Optical Coherency Tomography System

We have demonstrated that a microelectrical mechanical systems (MEMS) deformable mirror can be flattened to < 1 nm RMS within controllable spatial frequencies over a 9.2-mm aperture making it a viable option for high-contrast adaptive optics systems (also known as Extreme Adaptive Optics). The Extreme Adaptive Optics Testbed at UC Santa Cruz is being used to investigate and develop technologies for high-contrast imaging, especially wavefront control. A phase shifting diffraction interferometer (PSDI) measures wavefront errors with sub-nm precision and accuracy for metrology and wavefront control. Consistent flattening, required testing and characterization of the individual actuator response, including the effects of dead and low-response actuators. Stability and repeatability of the MEMS devices was also tested. An error budget for MEMS closed loop performance will summarize MEMS characterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical tomography reconstruction algorithm with the finite element method: An optimal approach with regularization tools

Highlights: •New strategies to improve the accuracy of the reconstruction through mesh and finite element parameterization. •Use of gradient filtering through an alternative inner product within the adjoint method. •An integral form of the cost function is used to make the reconstruction compatible with all finite element formulations, continuous and discontinuous. •Gradient-based algorithm with the adjoint method is used for the reconstruction. -- Abstract: Optical tomography is mathematically treated as a non-linear inverse problem where the optical properties of the probed medium are recovered through the minimization of the errors between the experimental measurements and their predictions with a numerical model at the locations of the detectors. According to the ill-posed behavior of the inverse problem, some regularization tools must be performed and the Tikhonov penalization type is the most commonly used in optical tomography applications. This paper introduces an optimized approach for optical tomography reconstruction with the finite element method. An integral form of the cost function is used to take into account the surfaces of the detectors and make the reconstruction compatible with all finite element formulations, continuous and discontinuous. Through a gradient-based algorithm where the adjoint method is used to compute the gradient of the cost function, an alternative inner product is employed for preconditioning the reconstruction algorithm. Moreover, appropriate re-parameterization of the optical properties is performed. These regularization strategies are compared with the classical Tikhonov penalization one. It is shown that both the re-parameterization and the use of the Sobolev cost function gradient are efficient for solving such an ill-posed inverse problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of elemental distributions on the behavior of MgO-based magnetic tunnel junctions.

Three-dimensional atom-probe tomography and transmission electron microscopy have been utilized to study the effects of Ta getter presputtering and either a Mg or Ru free-layer cap on the elemental distributions and properties of MgO-based magnetic tunnel junctions after annealing. Annealing the samples resulted in crystallization of the amorphous CoFeB layer and diffusion of the majority of the boron away from the crystallized CoFeB layers. The Ta getter presputter is found to reduce the segregation of boron at the MgO/CoFeB interface after annealing, improving the tunneling magnetoresistance of the tunnel junction. This effect is observed for samples with either a Ru free-layer cap or a Mg free-layer cap and is thought to be a result of a reduced oxygen concentration within the MgO due to the effect of Ta getter presputtering. A Ru free-layer cap provides superior magnetic and magnetotransport properties compared to a Mg free-layer cap. Mg from the Mg free-layer cap is observed to diffuse toward the MgO tunnel barrier upon annealing, degrading both the crystalline quality of the CoFeB and magnetic isolation of the CoFeB free-layer from the CoFeB reference-layer. Lateral variations in the B distribution within the CoFeB free-layer are observed in the samples with a Ru free-layer cap, which are associated with crystalline and amorphous grains. The B-rich, amorphous grains are found to be depleted in Fe, while the B-poor crystalline grains are slightly enriched in Fe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarization-entangled source for flex-grid C+L-band quantum networks

We demonstrate an ultrabroadband polarization-entangled source integrating both C- and L-band wavelength-selective switches for spectral routing and allocation in a single fiberized setup, verifying high fidelity through tomography of all 150 pairs of 25 GHz-wide channels.

Alshowkan, Muneer↗

Observable measurement-induced transitions

One of the main postulates of quantum mechanics is that measurements destroy quantum coherence (wave function collapse). Recently it was discovered that in a many-body system dilute local measurements still preserve some coherence across the entire system. As the measurement density is increased, a phase transition occurs that is characterized by the disentanglement of different parts of the system. Unfortunately, this transition is impossible to observe experimentally for macroscopic systems because it requires an exponentially costly full tomography of the many-body wave function or a comparison with the simulation on an oracle classical computer. In this work we report the discovery of another measurement-induced phase transition that can be observed experimentally if quantum dynamics can be reversed. On one side of this phase transition the quantum information encoded in some part of the Hilbert space is fully recovered after the time inversion. On the other side, all quantum information is corrupted. This transition also manifests itself as the change in the behavior of the probability to observe the same measurement outcome in the process that consists of identical blocks repeated many times. In each block the unitary evolution is followed by the measurement. On one side of the transition the probability decreases exponentially with the number of repetitions, on the other it tends to a constant as the number of repetitions is increased. We confirm the existence of the proposed phase transition through numerical simulations of realistic quantum circuits and analytical calculations using an effective random-matrix theory model.

Measurement-induced phase transitions↗

Detecting and tracking drift in quantum information processors

Abstract If quantum information processors are to fulfill their potential, the diverse errors that affect them must be understood and suppressed. But errors typically fluctuate over time, and the most widely used tools for characterizing them assume static error modes and rates. This mismatch can cause unheralded failures, misidentified error modes, and wasted experimental effort. Here, we demonstrate a spectral analysis technique for resolving time dependence in quantum processors. Our method is fast, simple, and statistically sound. It can be applied to time-series data from any quantum processor experiment. We use data from simulations and trapped-ion qubit experiments to show how our method can resolve time dependence when applied to popular characterization protocols, including randomized benchmarking, gate set tomography, and Ramsey spectroscopy. In the experiments, we detect instability and localize its source, implement drift control techniques to compensate for this instability, and then demonstrate that the instability has been suppressed.

97 MATHEMATICS AND COMPUTING↗

Software optimization for electrical conductivity imaging in polycrystalline diamond cutters

We previously reported on an electrical conductivity imaging instrument developed for measurements on polycrystalline diamond cutters. These cylindrical cutters for oil and gas drilling feature a thick polycrystalline diamond layer on a tungsten carbide substrate. The instrument uses electrical impedance tomography to profile the conductivity in the diamond table. Conductivity images must be acquired quickly, on the order of 5 sec per cutter, to be useful in the manufacturing process. This paper reports on successful efforts to optimize the conductivity reconstruction routine, porting major portions of it to NVIDIA GPUs, including a custom CUDA kernel for Jacobian computation.

36 MATERIALS SCIENCE↗

Doppler optical coherence microscopy and tomography applied to inner ear mechanics

While it is clear that cochlear traveling waves underlie the extraordinary sensitivity, frequency selectivity, and dynamic range of mammalian hearing, the underlying micromechanical mechanisms remain unresolved. Recent advances in low coherence measurement techniques show promise over traditional laser Doppler vibrometry and video microscopy, which are limited by low reflectivities of cochlear structures and restricted optical access. Doppler optical coherence tomography (DOCT) and Doppler optical coherence microscopy (DOCM) both utilize a broadband source to limit constructive interference of scattered light to a small axial depth called a coherence gate. The coherence gate can be swept axially to image and measure sub-nanometer motions of cochlear structures throughout the cochlear partition. The coherence gate of DOCT is generally narrower than the confocal gate of the focusing optics, enabling increased axial resolution (typically 15 μm) within optical sections of the cochlear partition. DOCM, frequently implemented in the time domain, centers the coherence gate on the focal plane, achieving enhanced lateral and axial resolution when the confocal gate is narrower than the coherence gate. We compare these two complementary systems and demonstrate their utility in studying cellular and micromechanical mechanisms involved in mammalian hearing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Class of backpropagation techniques for limited-angle reconstruction in microwave tomography

Filtered backpropagation (FBPP) is a well-known technique used in Diffraction Tomography (DT). For accurate reconstruction using FBPP, full 360° angular coverage is necessary. However, it has been shown that using some inherent redundancies in the projection data in a tomographic setup, accurate reconstruction is still possible with 270° coverage which is called the minimal-scan angle range. This can be done by applying weighing functions (or filters) on projection data of the object to eliminate the redundancies and accurately reconstruct the image from 270° coverage. This paper demonstrates procedures to generate many general classes of these weighing filters. These are all equivalent at 270° coverage but vary in performance at lower angular coverages and in presence of noise. This paper does a comparative analysis of different filters when angular coverage is lower than minimal-scan angle of 270°. Simulation studies have been done to find optimum weight filters for sub-minimal angular coverage (<270°)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A unified neural-network framework for nucleon imaging from numerical simulations of QCD

Parton distributions encode the momentum-space structure and, in their generalizations, the spatial tomography of quarks and gluons inside hadrons, the building blocks of visible matter. We present a unified neural-network approach that learns these distributions directly from matrix elements calculated via numerical simulations of quantum chromodynamics (QCD) on the lattice by fitting two complementary inputs simultaneously: data matched to physical quantities via known momentum-space and coordinate-space formalisms. Utilizing data from both methods stabilizes the extraction and mitigates biases that can arise when either is used alone. We validate the method on controlled mock data and apply it to lattice-QCD matrix elements to extract parton distribution functions (PDFs). We show benefits of such an approach for determining the physical quantities. We further extend the framework to zero-skewness generalized parton distributions and demonstrate nucleon tomography within the same neural-network parameterization. Our results provide an adaptable and systematically improvable approach for extracting partonic distributions from Euclidean correlators. It can incorporate polarization, additional channels, and future experimental constraints from current and future facilities, such as the Electron-Ion Collider.

Hadronic Spectroscopy↗

Electronic structure, morphology and emission polarization of enhanced symmetry InAs quantum-dot-like structures grown on InP substrates by molecular beam epitaxy

The optical and structural properties of a new kind of InAs/InGaAlAs/InP quantum dot (QD)-like objects grown by molecular beam epitaxy have been investigated. These nanostructures were found to have significantly more symmetrical shapes compared to the commonly obtained dash-like geometries typical of this material system. The enhanced symmetry has been achieved due to the use of an As{sub 2} source and the consequent shorter migration length of the indium atoms. Structural studies based on a combination of scanning transmission electron microscopy (STEM) and atom probe tomography (APT) provided detailed information on both the structure and composition distribution within an individual nanostructure. However, it was not possible to determine the lateral aspect ratio from STEM or APT. To verify the in-plane geometry, electronic structure calculations, including the energy levels and transition oscillator strength for the QDs have been performed using an eight-band k·p model and realistic system parameters. The results of calculations were compared to measured polarization-resolved photoluminescence data. On the basis of measured degree of linear polarization of the surface emission, the in-plane shape of the QDs has been assessed proving a substantial increase in lateral symmetry. This results in quantum-dot rather than quantum-dash like properties, consistent with expectations based on the growth conditions and the structural data.

36 MATERIALS SCIENCE↗

Three dimensional imaging and analysis of a single nano-device at the ultimate scale using correlative microscopy techniques

The analysis of a same sample using nanometre or atomic-scale techniques is fundamental to fully understand device properties. This is especially true for the dopant distribution within last generation nano-transistors such as MOSFET or FINFETs. In this work, the spatial distribution of boron in a nano-transistor at the atomic scale has been investigated using a correlative approach combining electron and atom probe tomography. The distortions present in the reconstructed volume using atom probe tomography have been discussed by simulations of surface atoms using a cylindrical symmetry taking into account the evaporation fields. Electron tomography combined with correction of atomic density was used so that to correct image distortions observed in atom probe tomography reconstructions. These corrected atom probe tomography reconstructions then enable a detailed boron doping analysis of the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical simulation of fiber interaction in short-fiber injection-molded composite using different cavity geometries

The theoretical fiber-interaction model for calculating the fiber orientation in the injection molded short fiber/thermoplastic composite parts was proposed. The proposed model included the fiber dynamics simulation in order to obtain an equation of the global interaction coefficient and accurate estimate of the fiber interacts at all orientation states. The steps to derive the equation for this coefficient in short fiber suspension as a function of the fiber aspect ratio, volume fraction and general shear rate are delineated. Simultaneously, the high-resolution 3D X-ray computed tomography system XVA-160α was used to observe fiber distribution of short-glass-fiber-reinforced polyamide specimens using different cavity geometries. The fiber orientation tensor components are then calculated. Experimental orientation measurements of short-glass-fiber-reinforced polyamide is used to check the ability of present theory for predicting orientation. The experiments and predictions show a quantitative agreement and confirm the basic understanding of fiber orientation in injection-molded composites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The second filter’s second coming

We measured sound-evoked vibrations at the stereociliary side of inner and outer hair cells and their surrounding supporting cells, using optical coherence tomography interferometry in living anesthetized guinea pigs. Our measurements demonstrate a gradient in frequency tuning among different cell types, going from a high best frequency at the inner hair cells to a lower one at the Hensen cells. This causes the locus of maximum inner hair cell activation to be shifted toward the apex of the cochlea as compared to the outer hair cells. These observations show that additional processing and filtering of acoustic signals occurs within the organ of Corti prior to inner hair cell excitation, thus reinstating a transformed second filter as a mechanism contributing to cochlear frequency tuning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Mobility and Electrostatics in GeSn Quantum Wells With SiGeSn Barriers

GeSn is an emerging material with potential applications in next‐generation integrated optoelectronics and quantum information processing. While GeSn/SiGeSn quantum wells exhibit promising optical properties, their electrical transport characteristics and governing electrostatics in gated structures remain unexplored. Heterostructure field‐effect transistors are fabricated using GeSn/SiGeSn quantum wells and electronic transport properties of 2D holes are characterized. At 2 K, heterostructure field‐effect transistors with well/barrier compositions of Ge 0.945 Sn 0.055 /Si 0.03 Ge 0.93 Sn 0.04 and Ge 0.9 Sn 0.1 /Si 0.017 Ge 0.927 Sn 0.056 , show peak mobilities of 9000 and 19 000 cm 2 /Vs, respectively, the latter setting a record for the highest mobility reported for GeSn quantum wells with a Sn concentration around 6 % or greater. Remarkably, at low carrier densities, devices with a SiGeSn barrier exhibit mobilities several times higher than previously reported for GeSn quantum wells with a Ge barrier. This higher mobility contrasts with the expectation that alloy scattering from the barrier would reduce carrier mobility. Two mechanisms based on atom probe tomography data analyses are proposed: i) unintentionally improved SiGeSn/GeSn interface and/or ii) reduced alloy scattering from short‐range order. Significant current–voltage hysteresis is observed, with the effective threshold gate voltage shifting by more than 5 V, attributed to non‐equilibrium trapped charge at various interfaces within the SiGeSn heterostructure.

GeSn↗