Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative phase imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A combined phase contrast imaging and heterodyne interferometer system for multiscale fluctuation measurements (invited)

In this work, a novel combined diagnostic capable of measuring multiscale density fluctuations that extend from magnetohydrodynamic (MHD) to the lower range of electron temperature gradient turbulence has been designed, installed, and operated at DIII-D. The combined diagnostic was constructed by adding a heterodyne interferometer to the pre-existing phase contrast imaging (PCI) system, both of which measure line-integrated electron density fluctuations. The port-space footprint is minimized via use of a single 10.6 μm probe beam. With temporal bandwidths in excess of 1 MHz, the PCI measures high-k (1.5 cm -1 < |k R | ≤ 25 cm -1 ) fluctuations with sensitivity 3×10 13 m -2 /$\sqrt{kHz}$, while the interferometer simultaneously measures low-k (|k R | < 5 cm -1 ) fluctuations with sensitivity 3×10 14 m -2 /$\sqrt{kHz}$. The intentional mid-k overlap has been empirically verified with sound-wave calibrations and allows quantitative investigation of multiscale effects that are predicted to be significant in the reactor-relevant T e ~ T i regime. Lastly, via correlation with the primary DIII-D interferometer, the toroidal mode numbers of core-localized MHD can be measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron Imaging at LANSCE—From Cold to Ultrafast

In recent years, neutron radiography and tomography have been applied at different beam lines at Los Alamos Neutron Science Center (LANSCE), covering a very wide neutron energy range. The field of energy-resolved neutron imaging with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as quantitative density measurements, was pioneered at the Target 1 (Lujan center), Flight Path 5 beam line and continues to be refined. Applications include: imaging of metallic and ceramic nuclear fuels, fission gas measurements, tomography of fossils and studies of dopants in scintillators. The technique provides the ability to characterize materials opaque to thermal neutrons and to utilize neutron resonance analysis codes to quantify isotopes to within 0.1 atom %. The latter also allows measuring fuel enrichment levels or the pressure of fission gas remotely. More recently, the cold neutron spectrum at the ASTERIX beam line, also located at Target 1, was used to demonstrate phase contrast imaging with pulsed neutrons. This extends the capabilities for imaging of thin and transparent materials at LANSCE. In contrast, high-energy neutron imaging at LANSCE, using unmoderated fast spallation neutrons from Target 4 [Weapons Neutron Research (WNR) facility] has been developed for applications in imaging of dense, thick objects. Using fast (ns), time-of-flight imaging, enables testing and developing imaging at specific, selected MeV neutron energies. The 4FP-60R beam line has been reconfigured with increased shielding and new, larger collimation dedicated to fast neutron imaging. The exploration of ways in which pulsed neutron beams and the time-of-flight method can provide additional benefits is continuing. We will describe the facilities and instruments, present application examples and recent results of all these efforts at LANSCE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron and X-ray Detectors

The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors: Improvements in the readout speed and energy resolution of X-ray detectors are essential to enable chemically sensitive microscopies. Advances would make it possible to take images with simultaneous spatial and chemical information. Very high-energy-resolution X-ray detectors: The energy resolution of semiconductor detectors, while suitable for a wide range of applications, is far less than what can be achieved with X-ray optics. A direct detector that could rival the energy resolution of optics could dramatically improve the efficiency of a multitude of experiments, as experiments are often repeated at a number of different energies. Very high-energy-resolution detectors could make these experiments parallel, rather than serial. Low-background, high-spatial-resolution neutron detectors: Low-background detectors would significantly improve experiments that probe excitations (phonons, spin excitations, rotation, and diffusion in polymers and molecular substances, etc.) in condensed matter. Improved spatial resolution would greatly benefit radiography, tomography, phase-contrast imaging, and holography. Improved acquisition and visualization tools: In the past, with the limited variety of slow detectors, it was straightforward to visualize data as it was being acquired (and adjust experimental conditions accordingly) to create a compact data set that the user could easily transport. As detector complexity and data rates explode, this becomes much more challenging. Three goals were identified as important for coping with the growing data volume from high-speed detectors: Facilitate better algorithm development. In particular, algorithms that can minimize the quantity of data stored. Improve community-driven mechanisms to reduce data protocols and enhance quantitative, interactive visualization tools. Develop and distribute community-developed, detector-specific simulation tools. Aim for parallelization to take advantage of high-performance analysis platforms. Improved analysis work flows: Standardize the format of metadata that accompanies detector data and describes the experimental setup and conditions. Develop a standardized user interface and software framework for analysis and data management. The diversity of detector improvements required is necessarily as broad as the range of scientific experimentation at BES facilities. This workshop identified a variety of avenues by which detector R&D can enable enhanced science at BES facilities. The Research Directions listed above will be addressed by focused R&D and detector engineering, both of which require specialized infrastructure and skills. While U.S. leadership in neutron and X-ray detectors lags behind other countries in several areas, significant talent exists across the complex. A forum of technical experts, facilities management, and BES could be a venue to provide further definition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validity of Machine Learning in the Quantitative Analysis of Complex Scanning Near-Field Optical Microscopy Signals Using Simulated Data

Scattering-type scanning near-field optical microscope (s-SNOM) is a modern technique for subdiffractional optical imaging and spectroscopy. Over the past two decades, tremendous efforts have been devoted to modeling complex tip-sample interactions in s-SNOM, aimed at understanding the electrodynamics of materials at the nanoscale. However, due to complexities in analytical methods and the limited computation power for fully numerical simulations, compromises must be made to facilitate the modeling of tip-sample interaction, such as using quasistatic approximation or unrealistic tip geometries. Here, we apply a variety of widely utilized machine-learning methods, including k nearest neighbor and feedforward neural network etc. to study the phase-resolved spectroscopic near-field response. With only a small set of training data, which is simulated using the finite-dipole model, we demonstrate that the relation between the experimental near-field signal and sample optical constant can be one to one mapped without the need for tip modeling: for a given material with a moderate dielectric function, its complex near-field spectrum can be accurately determined within the mid-IR spectral range, and vice versa. Our preliminary study sets the stage for future exploration using real experimental data. Our method is beneficial for processing the increasing amount of data accumulated across many research groups and especially useful for user facilities such as synchrotron-based national laboratories where a large amount of data is generated on a daily basis.

36 MATERIALS SCIENCE↗

In-situ investigation of thermal instabilities and solid state dewetting in polycrystalline platinum thin films via confocal laser microscopy

Solid state dewetting and the subsequent morphological changes for platinum thin films grown on zinc oxide (ZnO) buffered (001) silicon substrates (Pt/ZnO/SiO{sub 2}/(001)Si system) is investigated under vacuum conditions via a custom-designed confocal laser microscope coupled with a laser heating system. Live imaging of thin film dewetting under a range of heating and quenching vacuum ambients reveals events including hillock formation, hole formation, and hole growth that lead to formation of a network of Pt ligaments, break up of Pt ligaments to individual islands and subsequent Pt islands shape reformation, in chronological fashion. These findings are corroborated by ex-situ materials characterization and quantitative electron microscopy analysis. A secondary hole formation via blistering before film rupture is revealed to be the critical stage, after which a rapid dewetting catastrophe occurs. This process is instantaneous and cannot be captured by ex-situ methods. Finally, an intermetallic phase forms at 900 °C and alters the morphology of Pt islands, suggesting a practical limit to the thermal environments that may be used for these platinized silicon wafers in vacuum conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resolution enhancement of lung 4D-CT data using multiscale interphase iterative nonlocal means

Purpose: Four-dimensional computer tomography (4D-CT) has been widely used in lung cancer radiotherapy due to its capability in providing important tumor motion information. However, the prolonged scanning duration required by 4D-CT causes considerable increase in radiation dose. To minimize the radiation-related health risk, radiation dose is often reduced at the expense of interslice spatial resolution. However, inadequate resolution in 4D-CT causes artifacts and increases uncertainty in tumor localization, which eventually results in extra damages of healthy tissues during radiotherapy. In this paper, the authors propose a novel postprocessing algorithm to enhance the resolution of lung 4D-CT data. Methods: The authors' premise is that anatomical information missing in one phase can be recovered from the complementary information embedded in other phases. The authors employ a patch-based mechanism to propagate information across phases for the reconstruction of intermediate slices in the longitudinal direction, where resolution is normally the lowest. Specifically, the structurally matching and spatially nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical details, the authors employ a quad-tree technique to adaptively partition the image for more fine-grained refinement. The authors further devise an iterative strategy for significant enhancement of anatomical details. Results: The authors evaluated their algorithm using a publicly available lung data that consist of 10 4D-CT cases. The authors' algorithm gives very promising results with significantly enhanced image structures and much less artifacts. Quantitative analysis shows that the authors' algorithm increases peak signal-to-noise ratio by 3-4 dB and the structural similarity index by 3%-5% when compared with the standard interpolation-based algorithms. Conclusions: The authors have developed a new algorithm to improve the resolution of 4D-CT. It outperforms the conventional interpolation-based approaches by producing images with the markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Atomic Force Microscopy of Photosystem II and Its Unit Cell Clustering Quantitatively Delineate the Mesoscale Variability in Arabidopsis Thylakoids

Photoautotrophic organisms efficiently regulate absorption of light energy to sustain photochemistry while promoting photoprotection. Photoprotection is achieved in part by triggering a series of dissipative processes termed non-photochemical quenching (NPQ), which depend on the re-organization of photosystem (PS) II supercomplexes in thylakoid membranes. Using atomic force microscopy, we characterized the structural attributes of grana thylakoids from Arabidopsis thaliana to correlate differences in PSII organization with the role of SOQ1, a recently discovered thylakoid protein that prevents formation of a slowly reversible NPQ state. We developed a statistical image analysis suite to discriminate disordered from crystalline particles and classify crystalline arrays according to their unit cell properties. Through detailed analysis of the local organization of PSII supercomplexes in ordered and disordered phases, we found evidence that interactions among light-harvesting antenna complexes are weakened in the absence of SOQ1, inducing protein rearrangements that favor larger separations between PSII complexes in the majority (disordered) phase and reshaping the PSII crystallization landscape. The features we observe are distinct from known protein rearrangements associated with NPQ, providing further support for a role of SOQ1 in a novel NPQ pathway. The particle clustering and unit cell methodology developed here is generalizable to multiple types of microscopy and will enable unbiased analysis and comparison of large data sets.

59 BASIC BIOLOGICAL SCIENCES↗

Correlating Rate-Dependent Transition Metal Dissolution between Structure Degradation in Li-Rich Layered Oxides

Understanding the mechanism of the rate-dependent electrochemical performance degradation in cathodes is crucial to developing fast charging/discharging cathodes for Li-ion batteries. Here, in this work, taking Li-rich layered oxide Li 1.2 Ni 0.13 Co 0.13 Mn 0.54 O 2 as the model cathode, the mechanisms of performance degradation at low and high rates are comparatively investigated from two aspects, the transition metal (TM) dissolution and the structure change. Quantitative analyses combining spatial-resolved synchrotron X-ray fluorescence (XRF) imaging, synchrotron X–ray diffraction (XRD) and transmission electron microscopy (TEM) techniques reveal that low-rate cycling leads to gradient TM dissolution and severe bulk structure degradation within the individual secondary particles, and especially the latter causes lots of microcracks within secondary particles, and becomes the main reason for the fast capacity and voltage decay. In contrast, high-rate cycling leads to more TM dissolution than low-rate cycling, which concentrates at the particle surface and directly induces the more severe surface structure degradation to the electrochemically inactive rock-salt phase, eventually causing a faster capacity and voltage decay than low-rate cycling. These findings highlight the protection of the surface structure for developing fast charging/discharging cathodes for Li-ion batteries.

25 ENERGY STORAGE↗

The role of nuclear medicine in assessments of cardiac dyssynchrony

Radionuclide imaging has an advantage for quantitative analyses of the tracer concentration and its temporal changes. Myocardial perfusion and function have been adapted for synchrony analyses. Extracted parameters have been demonstrated to measure ventricular synchrony and even to predict CRT outcomes. ERNA has the advantages of higher temporal resolution, greater reproducibility, and the volumetric analysis of both ventricles that can be applied for analyses of intraventricular synchrony and interventricular synchrony. Several software packages such as Quantitative Gated SPECT, the Emory Cardiac Toolbox, cardioREPO, and Heart Function View are available to assess the LV dyssynchrony parameters from GSPECT. A count-based method is applied to extract the amplitude and phase from each of the reconstructed GSPECT short-axis datasets throughout the cardiac cycle and then subjected to a Fourier analysis, the results of which are displayed on a polar map and histogram. Some of the parameters such as the bandwidth (expressed as the 95% width of the phase histogram) and the standard deviation of the phase are obtained by the phase histogram to assess the intraventricular synchrony. This review paper focuses on the application of the LV dyssynchrony parameters estimated by cardiac SPECT in patients with a heart disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Terahertz Nano-Imaging of Electronic Strip Heterogeneity in a Dirac Semimetal

Emerging topological semimetals offer promise of realizing topological electronics enabled by terahertz (THz) current persistent against impurity scattering. Yet most fundamental issues remain on how to image nanoscale conductivity inhomogeneity. Here in this paper we show noninvasive and contactless conductivity mapping at THz-nm limit of electronic heterogeneity and nanostrip junctions in a Dirac material ZrTe 5 . A clear Dirac Fermion density transition, manifested as the exclusive THz conductivity contrast, is quantitatively analyzed and profiled on both sides of the junction. This also allows the determination of variable junction width of ~25–220 nm, depending on the THz conductivity contrast of adjacent strips. The unique THz-nm contrast is absent in mid-infrared nano-imaging measurements since topological semimetals with small Fermi pockets exhibit a better matching of their plasma frequency and scattering rate to the THz spectral region. The first-principles calculations provide two compelling implications: the conductivity nanocontrast can be induced by a small anisotropic strain, even less than 0.5%, due to an extreme strain sensitivity in ZrTe 5 ; A nanoscale topological phase transition is realized across some junctions induced by the strain, between strong topological insulators (TIs) and weak TIs/Dirac semimetals (DSMs).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional multimodal imaging and analysis of biphasic microstructure in a Ti–Ni–Sn thermoelectric material

The three-dimensional microstructure of levitation melted TiNi{sub 1.20}Sn has been characterized using the TriBeam system, a scanning electron microscope equipped with a femtosecond laser for rapid serial sectioning, to map the character of interfaces. By incorporating both chemical data (energy dispersive x-ray spectroscopy) and crystallographic data (electron backscatter diffraction), the grain structure and phase morphology were analyzed in a 155 μm × 178 μm × 210 μm volume and were seen to be decoupled. The predominant phases present in the material, half-Heusler TiNiSn, and full-Heusler TiNi{sub 2}Sn have a percolated structure. The distribution of coherent interfaces and high-angle interfaces has been measured quantitatively.

36 MATERIALS SCIENCE↗

Coordinated Mineralogical and Isotopic Analysis of a Cosmic Symplectite Identified in a Stardust Terminal Particle

Comet Wild-2 samples returned by the Stardust spacecraft contain a chemically diverse mixture of material, underscoring the complex nature of comets. Studies of entire Stardust aerogel tracks afford the opportunity to examine the fine-grained particle fragments distributed along the length of the track as well as the terminal particles. Previous TEM characterization of a terminal particle (TP) in track #147 revealed a symplectically intergrown iron sulfide and oxide assemblage. Mineralogically similar assemblages, known as cosmic symplectites (COS, formerly termed "new-PCP"), have only been identified in the primitive carbonaceous chondrite Acfer 094. Meteoritic COS have isotopically heavy O compositions (delta (sup 17), O-18 = 180per mille) that point to interactions with early solar system primordial water. In this study we report mineralogical and O isotopic measurements of the Wild-2 COS assemblage. Experimental: Track #147 is a "bulbous"-type track (4600 microns long) containing 7 terminal particles. The TPs were removed from the track, embedded in epoxy, and ultramicrotomed. A JEOL 2500SE 200 keV field-emission scanning-transmission electron microscope was used to obtain quantitative elemental maps and detailed mineralogical characterization. Following TEM analysis, two thin sections of TP4 (12 microns) were analyzed for O isotopes by raster ion imaging with the JSC NanoSIMS 50L. All three O isotopes were measured simultaneously using electron multipliers. San Carlos olivine grains were used as isotopic standards. Results and Discussion: The COS in the Wild-2 track #147 TP4 sample consists of symplectically intergrown pentlandite and nanocrystalline maghemite which coexists with high-Ca pyroxene with Na and Cr (kosmochlor component). This kosmochlor component could have a nebular origin and be precursors to type II chondrules in ordinary chondrites. Yet pentlandite is not a stable phase in the nebula. The COS in Acfer 094 also consists of pentlandite, but contains magnetite [4] rather than the more oxidized maghemite observed in the Wild-2 COS. The Acfer 094 COS display heavy O isotopic compositions that are the result of sulfidization and oxidation of Fe, Ni-metal grains and sulfides by O-17- and O-18-rich water in the solar nebula or possibly on the parent body. The O isotopic composition of the Wild-2 COS, however, is indistinguishable from terrestrial, indicating it was not altered by the same primordial aqueous reservoir as the Acfer 094 COS. The alteration could have occurred on the parent body by isotopically equilibrated ice. The mineralogy and petrography of Wild-2 samples suggests an incomplete or nascent hydration process. In future work we will analyze S isotopes in the track #147 TP4 COS and search for additional COS in Stardust samples.

Nguyen, A. N.↗

Understanding fission gas bubble distribution, lanthanide transportation, and thermal conductivity degradation in neutron-irradiated α-U using machine learning

U—10Zr based metallic nuclear fuel is the leading candidate for next-generation sodium-cooled fast reactors in the United States. US research reactors have used and tested this fuel type since the 1960s and accumulated considerable experience and knowledge about the fuel performance. Most of the knowledge, however, remains empirical. The lack of mechanistic understanding of fuel performance puts a large burden on proof through experimental verification for the qualification of U—10Zr fuel for commercial use. Further, this paper proposes an image data-driven machine learning approach, coupled with domain knowledge provided by advanced post irradiation examination, to provide unprecedented quantified insights into the morphology, size, density and the connectivity of fission gas bubbles and their effects on the fission product transportation and thermal conductivity. Specifically, we developed a method to automatically detect, extract statistics, and classify ~19,000 fission gas bubbles into different categories, and quantitatively link the data to lanthanide transportation through connected bubbles and degradation of thermal conductivity along the radial temperature gradient in a neutron irradiated U—10Zr annular fuel. Results indicate the approach can be modified to study other irradiation effects, such as secondary phase redistribution and gaseous fuel swelling in other irradiated nuclear fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Insight into 3D micro-CT data: exploring segmentation algorithms through performance metrics

Three-dimensional (3D) micro-tomography (µ-CT) has proven to be an important imaging modality in industry and scientific domains. Understanding the properties of material structure and behavior has produced many scientific advances. An important component of the 3D µ-CT pipeline is image partitioning (or image segmentation), a step that is used to separate various phases or components in an image. Image partitioning schemes require specific rules for different scientific fields, but a common strategy consists of devising metrics to quantify performance and accuracy. The present article proposes a set of protocols to systematically analyze and compare the results of unsupervised classification methods used for segmentation of synchrotron-based data. Additionally, the proposed dataflow for Materials Segmentation and Metrics (MSM) provides 3D micro-tomography image segmentation algorithms, such as statistical region merging (SRM), k-means algorithm and parallel Markov random field (PMRF), while offering different metrics to evaluate segmentation quality, confidence and conformity with standards. Both experimental and synthetic data are assessed, illustrating quantitative results through the MSM dashboard, which can return sample information such as media porosity and permeability. The main contributions of this work are: (i) to deliver tools to improve material design and quality control; (ii) to provide datasets for benchmarking and reproducibility; (iii) to yield good practices in the absence of standards or ground-truth for ceramic composite analysis.

97 MATHEMATICS AND COMPUTING↗

Robust Quantitative Measurement of Flows and Transparent or Highly Reflective Objects

The liquid crystal point diffraction interferometer (LCPDI) is a new instrument that has been developed for the measurement of phase objects. The LCPDI uses the compact, robust design of Linnik's point diffraction interferometer and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wave-fronts. A solid state camera provides very high data density and automated data reduction. The instrument can measure either transparent objects like fluids and lenses, or highly reflective opaque objects like mirrors. In the former case, the refractive index distribution is measured and then related to various properties like temperature, density, chemical composition, or thickness. In the latter case, the measured phase distribution is related to the object shape. The objects measured must be stationary or quasisteady state because the measurement requires the acquisition of several frames of image data during which time the object's properties must not have changed. The data acquisition time depends on the speed of the frame grabber and the required number of data frames. Typically, three to five frames taking 1 to 2 seconds are required. The potential for faster data acquisition exists.

Mercer, Carolyn R.↗

Enhancement of Second-Order Nonlinear-Optical Signals by Optical Stimulation

Second-order nonlinear optical interactions such as sum- and difference-frequency generation are widely used for bioimaging and as selective probes of interfacial environments. However, inefficient nonlinear optical conversion often leads to poor signal-to-noise ratio and long signal acquisition times. We demonstrate the dramatic enhancement of weak second-order nonlinear optical signals via stimulated sum- and difference-frequency generation. We present a conceptual framework to quantitatively describe the interaction and show that the process is highly sensitive to the relative optical phase of the stimulating field. To emphasize the utility of the technique, we demonstrate stimulated enhancement of second harmonic generation (SHG) from bovine collagen-I fibrils. Using a stimulating pulse fluence of only $3\text{ }\text{ }\mathrm{nJ}/{\mathrm{cm}}^{2}$, we obtain an SHG enhancement >${10}^{4}$ relative to the spontaneous signal. The stimulation enhancement is greatest in situations where spontaneous signals are the weakest—such as low laser power, small sample volume, and weak nonlinear susceptibility—emphasizing the potential for this technique to improve signal-to-noise ratios in biological imaging and interfacial spectroscopy.

42 ENGINEERING↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Impact of Controlled Storage Conditions on the Hydrolysis and Surface Morphology of Amorphous-UO 3

The hydration and morphological effects of amorphous (A)-UO 3 following storage under varying temperature and relative humidity have been investigated. This study provides valuable insight into U-oxide speciation following aging, the U-oxide quantitative morphological data set, and, overall, the characterization of nuclear material provenance. A-UO 3 was synthesized via the washed uranyl peroxide synthetic route and aged based on a 3-factor circumscribed central composite design of experiment. Target aging times include 2.57, 7.00, 14.0, 21.0, and 25.4 days, temperatures of 5.51, 15.0, 30.0, 45.0, and 54.5 °C, and relative humidities of 14.2, 30.0, 55.0, 80.0, and 95.8% were examined. Following aging, crystallographic changes were quantified via powder X-ray diffraction and an internal standard Rietveld refinement method was used to confirm the hydration of A-UO 3 to crystalline schoepite phases. The particle morphology from scanning electron microscopy images was quantified using both the Morphological Analysis of MAterials software and machine learning. Results from the machine learning were processed via agglomerative hierarchical clustering analysis to distinguish trends in morphological attributes from the aging study. Significantly hydrated samples were found to have a much larger, plate-like morphology in comparison to the unaged controls. Predictive modeling via a response surface methodology determined that while aging time, temperature, and relative humidity all have a quantifiable effect on A-UO 3 crystallographic and morphological changes, relative humidity has the most significant impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗