Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Thermal Storage Integrated into Air-Source Heat Pumps to Leverage Building Electrification: A Systematic Literature Review

Air-source heat pumps (ASHPs) can support a decarbonized economy by replacing combustion appliances in homes and electrifying heating systems in buildings. However, ASHPs have not seen significant adoption primarily due to deteriorated performance under cold conditions - at very low temperatures they require auxiliary resistance heating to meet the heating demand and defrost the evaporator. The additional heat lowers the system efficiency. Thermal energy storage (TES) is a candidate technology to help overcome some of these issues. This paper presents a systematic literature review to map the existing research on the integration of TES into ASHPs. Our review of 59 publications indicates that thermal storage increases the ASHP coefficient of performance by 27% on average, albeit with higher initial cost compared to conventional fossil-fueled heating systems. Phase change materials may be ideal to be integrated with ASHPs due to their high energy density and compact design, but only a few publications address TES sizing and design. First and Second Laws of Thermodynamics are widely used to create metrics to assess ASHP-TES integration, and only recently have cost and environmental impact been explored. This literature review suggests that more comprehensive metrics are needed to evaluate the potential benefits of ASHP-TES systems.

air source heat pump↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time-resolved electrical potential pump – X-ray photoelectron spectroscopy probe developments for investigating dynamic processes occurring at electrochemical interfaces

Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.

Electrochemistry↗

Dual-Functional Thermocapacitive Heat Pump with Electrochemical Supercapacitors for Building Thermal Management and Energy Storage

Efficient heating and cooling technologies can help reduce the energy consumption and carbon emissions of buildings. This work explores the use of supercapacitive cells in a multifunctional, liquid-regenerated thermocapacitive heat pump that can provide electrical energy storage in addition to heating and cooling. A proof-of-concept prototype based on eight commercial supercapacitors and using deionized water as a liquid regenerator demonstrated cooling and energy storage capabilities. A peak cooling coefficient of performance (COPc) of 0.27 was achieved at a temperature drop of 0.24 K. The highest measured electrical energy storage density of the cells was 5.93 J cm-3, and the highest cooling power delivered relative to the volume of the cells was 0.58 mW cm-3. This work demonstrates the use of electrochemical energy storage devices in multifunctional equipment for thermal management in buildings.

25 ENERGY STORAGE↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

Experimental performance of ejector heat pump operating in the sub-critical mode

Ejector heat pump (EHP) is an efficient-energy technology with a promising potential to replace the vapor compression cycle in heating and cooling applications. It can be powered by low-grade waste heat and uses environmentally friendly working fluids. EHP has also become a viable solution in research seeking cooling applications. However, little attention has been paid to using EHP for heating purposes. In order to investigate this, a steam EHP for domestic water heating was designed and built. The coefficient of performance (COP) is evaluated at various operating and design conditions in sub-critical operational modes to achieve higher condensation temperatures. Two primary nozzles with a throat diameter of 1.5 mm and 2.0 mm were investigated. The primary nozzle is movable along the ejector’s axis, allowing investigation of its positional effects on the EHP’s COP. Further, experimental measurements revealed that using a smaller throat diameter results in a high COP and low back pressure. The EHP COP and back pressure increase when the LTE temperature increases. Using a throat diameter of 1.5 mm, the EHP COP increases as the nozzle exit position (NXP) becomes closer to the constant area section. A COP of 2.42 and a back pressure of 4.28 kPa are achieved at a high-temperature evaporator (HTE) temperature of 130 °C and a low-temperature evaporator (LTE) temperature of 30 °C using a primary nozzle with 1.5 mm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation

The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.

Demand response control↗

The impact of argon addition on hydrogen superpermeation through palladium alloy metal foil pumps during direct internal recycling

Metal foil pumps (MFPs) are a leading technology for the direct internal recycling (DIR) of hydrogen isotopes from the plasma exhaust of fusion devices. MFPs rely on the concept of superpermeation, where plasma-generated atomic hydrogen absorbs into the metal foil, rapidly diffuses, and desorbs downstream. To date, studies of superpermeation have predominantly employed pure hydrogen or in some cases trace levels of impurities. In practice the plasma exhaust may contain significant levels of plasma enhancement gases such as argon, an inert gas with metastable states that can enhance the plasma. In this work, we systematically study the impact of Ar addition on the performance of PdCu and PdAg MFPs at low temperature. Performance was strongly dependent on the DIR fraction. At negligible DIR levels Ar addition did not significantly improve the flux over dilution effects. However, under appreciable DIR operation the flux was enhanced up to 90 % relative to pure H 2 , with the optimal concentration range being 5–10 % Ar exiting the system. Beyond 15 % addition plasma enhancement benefits were offset by dilution. Performance correlated with the atomic H emission, and benefits were more pronounced for PdAg than PdCu. Operation at significant DIR levels dramatically alters the flow dynamics resulting in concentration gradients near the MFP, creating plasma conditions that promote H 2 dissociation.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental results of embedded phase change material capsules for increasing the performance of a wrapped heat pump water heater

Herein, to enhance the capacity of heat pump water heaters (HPWHs), high energy density phase change material (PCM) was used in two experimentally tested HPWH prototypes. Preliminary findings showed that in the PCM, stored thermal potential energy could be effectively converted into sensible heat in the water over a slight temperature difference, with the goal of increasing the capacity of hot water above a desired cut-off temperature. This exchange of energy results in an increased amount of hot water necessary for mixing at the location utilized by the consumer. It was also found that for a wrapped HPWH, there was an average increase of 27.7% in the capacity when 7.6 L of novel PCM filled spherical capsules were added to a 22.7 L tank downstream of the HPWH. In the second design (Beta), PCM capsules were immersed into the tank with a cylindrical geometry, and the UEF was increased by 5.5% over the baseline HPWH test result. As for the Beta design, heat loss was reduced significantly compared to a typical HPWH and the Alpha design. Food-grade PCMs were selected as appropriate. The novel encapsulation design increased the effective conductivity inside the capsule by adding metal fins.

42 ENGINEERING↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Demand reduction and energy saving potential of thermal energy storage integrated heat pumps [Réduction de la demande et potentiel d'économie d'énergie des pompes à chaleur avec stockage d'énergie thermique intégré]

A heat pump (HP) moves heat from a low-temperature source to a high-temperature sink with an input of energy. Often, one temperature body fluctuates with time (e.g., diurnal ambient temperature), causing the HP efficiency to vary. Integrating thermal energy storage (TES) into a HP system adds a third temperature body, enabling the HP to be advantageously coupled to any two: the application, the ambient, or the TES at strategic times. Although TES integration with HPs is an important emerging technology to lower energy consumption and decrease energy demand during critical times, the favorable circumstances for TES integration are poorly understood. Here, this paper establishes the energy reduction and demand reduction potential of TES-integrated HPs with both analytical and numerical HP models. All possible temperature arrangements are considered for HP-TES systems with two fixed temperature bodies (application and TES) and one variable temperature (ambient). Results show that overall energy savings are most attainable when the TES temperature is near the application temperature, whereas a large temperature difference between the TES and the application leads to the most peak demand reduction. The potential for overall energy savings increases as the magnitude of ambient temperature fluctuations increases.

25 ENERGY STORAGE↗

Low temperature hydrogen superpermeation in vanadium composite metal foil pumps

Palladium-based foil membranes are an effective option for hydrogen isotope recovery from the plasma exhaust of future fusion plants, but cost and availability are concerns. Vanadium (V) is a relatively low cost, neutron tolerant material with high hydrogen permeability. It has been well-studied as a superpermeable membrane at high temperature (>500 °C), but V displays negligible superpermeation at low temperature (75–200 °C) due to catalytic limitations. Composite membranes were fabricated by depositing thin layers (~100 nm) of either Pd or BCC PdCu on sputter-cleaned vanadium foils (100 μm). Symmetric membranes elevated superpermeation to levels approaching bulk Pd or PdCu foils, with ~5X higher flux in the latter reflecting the superior properties of PdCu. Asymmetric membranes revealed that the Pd-based catalyst layer was critical for both efficient absorption of superthermal hydrogen upstream as well as catalyzing re-combinative desorption downstream. At T ≥ 150 °C composite membrane superpermeation was equivalent to the Pd-based foils, but the flux was attenuated by a factor of 2-3X as the temperature was reduced. This deviation from pure foil performance coincided with the formation of vanadium hydride (β-V 2 H), which also impacted the transient response. Nevertheless, no embrittlement was observed under the conditions examined and elevating the temperature >150 °C removed the hydride and restored full performance. The achievement of palladium-level performance with a >99% reduction in Pd inventory makes these V composite metal foils pumps an attractive option for low temperature hydrogen isotope recovery in future fusion plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Medium-temperature phase change material integration in domestic heat pump water heaters for improved thermal energy storage

In this review, we examine state-of-the-art developments in integrating phase change materials (PCMs) for thermal energy storage (TES) in domestic heat pump water heaters (HPWHs). The component design optimization and control optimization of HPWHs and TES are reviewed for insight into improving the thermal capacity and efficiency of a PCM-integrated HPWH. The state-of-the-art review is categorized by the stage of development of the PCM for deployment in HPWHs. To select appropriate PCMs for HPWHs, a six-factor down-selection process is used to determine the best material(s) for integration in HPWHs with appropriate heat exchanger design. Ultimately, food-grade PCMs appear to be the best candidate for integration of TES in domestic HPWHs because they are nontoxic, highly cyclable, and have heat transfer properties accommodable to water heating when integrated in a manner to overcome the thermal conductivity limitations of the material. A key parameter of water heating performance is thermal heating power of the PCM component, which is not often reported. Many studies report significant improvement in capacity and efficiency. Furthermore, many performance metrics are identified from the literature to quantify the system performance, but agreement across studies is not found. Unified energy factor and first hour rating performance tests are required for commercially available HPWHs, and these performance metrics could homogenize the literature. Ultimately, we find that select PCMs are ready for deployment with HPWHs for performance improvement, and component design and control optimizations are new avenues of research and development required for a commercially viable PCM-integrated HPWH system.

25 ENERGY STORAGE↗

Demonstration of an All-Refractory Corrosion-Resistant Molten Salt Pumping and Storage Infrastructure Up to 950 degrees C

Concentrating solar power (CSP) with thermal energy storage (TES) has an estimated cost similar to solar photovoltaics (PV) with lithium-ion batteries (LIB), but CSP + TES has the potential for significantly reduced cost by operating above 700 degrees C. However, this requires a TES medium and containment infrastructure which are chemically compatible and do not degrade above 700 degrees C. MgCl2-KCl-NaCl (MKN) salt is a promising medium, but when MKN salt has small amounts of water and oxygen dissolved in it, it excessively corrodes conventional commercial alloys. Here, we consider refractory materials including graphite, carbon-carbon composite (C/C), and molybdenum because they maintain high mechanical strength at elevated temperatures and are expected to resist corrosion by MKN salt. While selection of refractory materials is often constrained by the need to remain chemically stable in air, this work uses an enclosure filled with inert gas to allow the use of materials like graphite and molybdenum. Notably, graphite components can seal against liquids unlike many brittle refractory materials. We demonstrate a centrifugal pump and mechanical seals made of refractory materials in a laboratory-scale circulation loop, which successfully operated continuously for more than 49 h at temperatures ranging from 750 degrees C to 950 degrees C with no mechanical failures or chemical degradation of the refractory materials. To the best of our knowledge, this is the highest temperature molten salt circulation loop that has been successfully developed, and this refractory infrastructure allows for operation at even much higher temperatures (<1600 degrees C) if a storage medium with a lower vapor pressure is used. The principles of this architecture are relevant to other applications with high temperature flowing metals and salts including Generation IV nuclear fission reactors for power production and molten salt electrolysis reactors for metallurgical processing.

14 SOLAR ENERGY↗

Thermodynamic analysis of a two-stage binary-fluid ejector heat pump water heater

Ejector heat pump water heaters (EHPWHs) could significantly increase the thermal efficiency of domestic water heating and reduce greenhouse gas emissions. This study addresses two major technical barriers to using EHPWHs in domestic water heating—low heating cycle coefficient of performance (COP) and low condensation temperatures—using binary fluid pairs as a working fluid in a two-stage ejector system. A comprehensive, geometry-free model of binary-fluid ejectors was built and validated to predict the entrainment ratios of binary-fluid ejectors. A thermodynamic model of a two-stage binary-fluid ejector EHPWH was built to predict the heating cycle COP of EHPWHs. The performance of the EHPWH was theoretically evaluated using HFE7000 and Novec649 as primary fluids and R600 and R1234ze(Z) as secondary fluids. HFE7000/R600 gave the highest heating cycle COP (i.e., 1.356) in producing domestic hot water at 60.0 °C. An optimum evaporation temperature of the primary fluid was identified for the maximum effective entrainment ratio and effective pressure lift ratio of two-stage ejectors. Here, the effective entrainment ratio of the two-stage ejector dominated the heating cycle COP of the EHPWH. Primary fluids with lower latent heats of evaporation and/or secondary fluids with higher latent heats of evaporation yielded higher heating cycle COPs of EHPWHs.

42 ENGINEERING↗