Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

Novel inorganic sorbent for iodine removal in pump and treat system - 15020

The radioisotope {sup 129}I is one of the key risk components in the migrating subsurface plumes present in the Hanford Site vadose zone due to its long half-life, large inventory, high toxicity, and high mobility in the aquifer. Removal of iodine from groundwater in the 200 Area is an essential component for managing the Hanford Site cleanup and protecting the Columbia River. In the subsurface aquatic environment it mainly exist as iodide, iodate, and organic derivatives of iodine. Because of different chemical properties of these species and significantly lower concentration than other constituents in the subsurface plumes their removal using commercial ion exchange resins is problematic. In addition, availability of a stable matrix for a long-term waste form for iodine is needed. Novel engineered inorganic composites that possess superior characteristics including large surface area, high sorption capacity, and good chemical-mechanical-thermal stability may potentially offer a solution. These two-in-one novel materials can be designed to serve as an efficient sorbent for the simultaneous removal of the dissimilar iodine species and a durable waste form under environmentally relevant conditions. This paper describes our current results on identification, characterization, and testing of the iodine-selective inorganic sorbents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HERO WEC - Bills of Materials: WEC, RO System, and Submersible Pump

This submission includes detailed Bills of Materials for the NREL-designed and -built Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC), as well as the reverse osmosis assembly and submersible pump that are used in the HERO WEC. The WEC file is specific to the components and sub-components that are included on the in-water buoy portion of the WEC. The RO file is specific to the components and sub-components that are included on the reverse osmosis module that is used for both the hydraulic and electric configuration. The submersible pumps file is specific to the components and sub-components that are included on the submersible pump module that is used feed the reverse osmosis module when the HERO WEC is in the electric configuration. In addition to this submission, an additional submission available for the WEC model itself, including the power electronics enclosure, and reverse osmosis assembly that is needed to supply water in the electric submission. A link is provided below. More details on this project including data, CAD drawings, etc. can be found in the HERO-WEC main page link below. This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Assessment of Pump-and-Treat System Impacts on 200 West Aquifer Conditions

The 200 West P&T system is one of the key components of the final remedy selected for the 200-ZP-1 Operable Unit (OU), and the interim remedial action selected for 200-UP-1 OU at the Hanford Site. In addition, the facility has been receiving water from several other sources, such as 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. It is anticipated that the P&T system will continue to receive water from other sources, which may include Modular Storage Unit (purge) water, groundwater near the Waste Management Area C, and Gable Gap. Furthermore, maintaining the injection capacity of the system has been a significant issue since the facility startup in 2012. Fouling issues at the injection wells have necessitated frequent well redevelopment, resulting in decrease in injection capacity and the need to construct new injection wells—with significant effects on system performance and operational costs. Given the evolving nature of treatment plant effluent due to changes in influent, combined with issues observed at the injection wells, it is important to understand the impacts of the P&T operations on the 200 West aquifer where the treated water is injected. This study aims at determining these impacts and providing a quantitative evaluation of aquifer capacity for both current and future conditions. This information will provide a technical basis for decisions related to the P&T system operations that support remedy optimization efforts and short- and long-term remedy decisions related to multiple OUs in the Central Plateau.

Demirkanli, Deniz I.↗

Laser Doppler velocimetry for continuous flow solar-pumped iodine laser system

A laser Doppler velocimetry (LDV) system was employed to measure the flow velocity profile of iodide vapor inside laser tubes of 36 mm ID and 20 mm ID. The LDV, which was operated in the forward scatter mode used a low power (15 mW) He-Ne laser beam. Velocity ranges from 1 m/s was measured to within one percent accuracy. The flow velocity profile across the laser tube was measured and the intensity of turbulence was determined. The flow of iodide inside the laser tube demonstrated a mixture of both turbulence and laminar flow. The flowmeter used for the laser system previously was calibrated with the LDV and found to be in good agreement.

Tabibi, Bagher M.↗

Space Station Environmental Control and Life Support System Purge Control Pump Assembly Modeling and Analysis

Preliminary results from a thermal/flow analysis of the Purge Control Pump Assembly (PCPA) indicate that pump performance (mass flow rate) is enhanced via cooling of the housing and lowering of the inlet vapor quality. Under a nominal operational profile (25% duty cycle or less), at the maximum motor dissipation, it appears that the peristaltic tubing temperature will still remain significantly below the expected UPA condenser temperature (78 F max versus approximately 105 F in the condenser) permitting condensation in the pump head.

Schunk, R. Gregory↗

Photovoltaic-assisted heat pump water heater system and method

A solar power system has a photovoltaic module that supplies electrical current derived from sunlight to a heater system of a hot water tank. The heater system uses the electrical energy from the photovoltaic module, and optionally also from a local power grid, to heat water up to a selected maximum stored hot water temperature. Control circuitry senses when the level of electrical power is below a threshold solar-power level, and in response sets the stored hot water temperature for the heater system to a first lower temperature value. The control circuitry also senses when the level of electrical power is above the threshold solar-power level, an in response sets the stored hot water temperature for the heater system to a second elevated temperature value higher than the lower temperature, making advantageous use of solar power when available. A mixing unit adds cold water to set the dispensed water temperature.

14 SOLAR ENERGY↗