Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

TU-H-CAMPUS-IeP1-03: Comparison of Monte Carlo Simulation and Conversion Factor Based Method On Estimation of Effective Dose in Pediatric Patients Undergoing Interventional Cardiac Procedures

Purpose: Interventional cardiac procedures utilize frequent fluoroscopy and cineangiography, which impose considerable radiation risk to patients, especially pediatric patients. Accurate calculation of effective dose is important in order to estimate cancer risk over the rest of their lifetime. This study evaluates the difference in effective dose calculated by Monte Carlo simulation with those estimated by locally-derived conversion factors (CF-local) and by commonly quoted conversion factors from Karambatsakidou et al (CF-K). Methods: Effective dose (E),of 12 pediatric patients, age between 2.5–19 years old, who had undergone interventional cardiac procedures, were calculated using PCXMC-2.0 software. Tube spectrum, irradiation geometry, exposure parameters and dose-area product (DAP) of each projection were included in the software calculation. Effective doses for each patient were also estimated by two Methods: 1) CF-local: conversion factor derived locally by generalizing results of 12 patients, multiplied by DAP of each patient gives E-local. 2) CF-K: selected factor from above-mentioned literature, multiplied by DAP of each patient gives E-K. Results: Mean of E, E-local and E-K were 16.01 mSv, 16.80 mSv and 22.25 mSv respectively. A deviation of −29.35% to +34.85% between E and E-local, while a greater deviation of −28.96% to +60.86% between E and EK were observed. E-K overestimated the effective dose for patients at age 7.5–19. Conclusion: Effective dose obtained by conversion factors is simple and quick to estimate radiation risk of pediatric patients. This study showed that estimation by CF-local may bear an error of 35% when compared with Monte Carlo calculation. If using conversion factors derived by other studies may result in an even greater error, of up to 60%, due to factors that are not catered for in the estimation, including patient size, projection angles, exposure parameters, tube filtration, etc. Users must be aware of these potential inaccuracies when simple conversion method is employed.

60 APPLIED LIFE SCIENCES↗

Subtractive procedure for calculating the anomalous electron magnetic moment in QED and its application for numerical calculation at the three-loop level

A new subtractive procedure for canceling ultraviolet and infrared divergences in the Feynman integrals described here is developed for calculating QED corrections to the electron anomalous magnetic moment. The procedure formulated in the form of a forest expression with linear operators applied to Feynman amplitudes of UV-diverging subgraphs makes it possible to represent the contribution of each Feynman graph containing only electron and photon propagators in the form of a converging integral with respect to Feynman parameters. The application of the developed method for numerical calculation of two- and threeloop contributions is described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Fast Temporal Decomposition Procedure for Long-Horizon Nonlinear Dynamic Programming

We propose a fast temporal decomposition procedure for solving long-horizon nonlinear dynamic programs. The core of the procedure is sequential quadratic programming (SQP) that utilizes a differentiable exact augmented Lagrangian as the merit function. Within each SQP iteration, we approximately solve the Newton system using an overlapping temporal decomposition strategy. We show that the approximate search direction is still a descent direction of the augmented Lagrangian provided the overlap size and penalty parameters are suitably chosen, which allows us to establish the global convergence. Moreover, we show that a unit step size is accepted locally for the approximate search direction and further establish a uniform, local linear convergence over stages. This local convergence rate matches the rate of the recent Schwarz scheme (Na et al. 2022). However, the Schwarz scheme has to solve nonlinear subproblems to optimality in each iteration, whereas we only perform a single Newton step instead. Numerical experiments validate our theories and demonstrate the superiority of our method.

97 MATHEMATICS AND COMPUTING↗

Rejection of malathion by nanofiltration and reverse osmosis membranes exposed to foulant and two clean-in-place procedures

This research tested the treatment efficacy of an Energy Savings Nanofiltration 1 Low Fouling (ESNA 1-LF) nanofiltration (NF) and an Energy Saving Polyamide 2 (ESPA2) reverse osmosis (RO) membrane for removing malathion from water. Both membranes are of composite polyamide construction. The study included measuring malathion rejection using both pristine membranes and membranes exposed to a simulated secondary wastewater effluent foulant before and after two types of clean-in-place procedures. Across all conditions studied, malathion rejection ranged from 84 to 95% for the ESNA1-LF NF membrane and 77 to 94% for the ESPA2 RO membrane. Contact angle measurements were also collected for each membrane exposure condition. While the contact angle measurements indicated changes to the hydrophobicity of the selective layer of the membranes, they did not correlate to changes in the performance of malathion rejection. As expected, it was observed that malathion rejection improved with the introduction of foulant. Also, the clean-in-place procedures helped restore flux while maintaining malathion rejection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an Accelerated Microbial Procedure (Final Report)

Cool-roof coating technologies make buildings more energy efficient, reducing energy consumption as well as air pollution in temperate and hot climates. The performance of a cool roof can diminish significantly when exposed to adverse environmental agents such as dust, soot, and pollens as well as microorganisms. There is currently no equivalent method to accelerate testing of cool roof erformance. We developed an experimental procedure to test cool roof samples using a defined mixture of both photoautotrophic and heterotrophic microorganisms that would produce an equivalent, faster test for biodeterioration. The mixture consists of 6 bacterial, 3 algal, and 4 fungal species suspended in rich media. Microbial biofilms developed rapidly on the coating surface. Any cool-roof technology could be tested using this microbial aging procedure. If the surface of a material is accessible to the microbial mixture, the growth of a microbial biofilm could reduce the solar reflectance to less than 50% of its initial value within 2 months. Thus, it completes the test cycle required by the ENERGY STAR ® program in only 2 months instead of 3 years by the biofilm alone.

14 SOLAR ENERGY↗

Procedure to Generate the MPACT Multigroup Library

The CASL neutronics simulator MPACT is under development for the neutronics and T-H coupled simulation for the light water reactor. The objective of this document is focused on reviewing the current procedure to generate the MPACT multigroup library. Detailed methodologies and procedures are included in this document for further discussion to improve the MPACT multigroup library.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Procedures for Calculating Residential Dehumidification Loads

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

47 OTHER INSTRUMENTATION↗

Powertrain Test Procedure Development for EPA GHG Certification of Medium- and Heavy-Duty Engines and Vehicles

xiii ABSTRACT The goal of this project is to develop and evaluate powertrain test procedures that can accurately simulate real-world operating conditions, and to determine greenhouse gas (GHG) emissions of advanced medium- and heavy-duty engine and vehicle technologies. ORNL used their Vehicle System Integration Laboratory to evaluate test procedures on a stand-alone engine as well as two powertrains. Those components where subjected to various drive cycles and vehicle conditions to evaluate the validity of the results over a broad range of test conditions. Overall, more than 1000 tests were performed. The data are compiled and analyzed in this report.

33 ADVANCED PROPULSION SYSTEMS↗

Module OT PNM Field Demonstration Test Procedure

This document will detail a field demonstration test procedure for the Module OT device developed for the joint NREL-SNL DOE CEDS project titled "Modular Security Apparatus for Managing Distributed Cryptography for Command & Control Messages on Operational Technology (OT) Networks." The aim of this document is to create the testing and evaluation procedure for field demonstration of the device; this includes primarily functional testing and implementation testing at Public Service Company of New Mexico's (PNM's) Prosperity solar site environment. Specifically, the Module OT devices will be integrated into the Prosperity solar site system; traffic will be encrypted between several points of interest at the site (e.g., inverter micrologger and switch). The tests described in this document will be performed to assess the impact and effectiveness of the encryption capabilities provided by the Module OT device.

97 MATHEMATICS AND COMPUTING↗

Quality Procedures for TCR Metal Core Structure Advanced Manufacturing Processes

The Transformational Challenge Reactor (TCR) Manufacturing WBS# 3.02.04.02 organization is responsible for the advanced manufacturing process, research, development, and implementation that supports the TCR program under the TCR Additive Manufacturing (AM) Thrust. Advanced manufacturing at Oak Ridge National Laboratory (ORNL) includes the development and capabilities to use modern advanced manufacturing techniques, such as AM (e.g., 3D printing) and other novel methods, to rapidly design, develop, produce, finish, and characterize parts, samples, and components to support the nuclear and other high-quality standards industries. Deliverable # M2TC-20OR04020110 involved the development of TCR quality procedures for the TCR metal core structure by using the advanced manufacturing processes being developed at ORNL’s Manufacturing Demonstration Facility (MDF) and other ORNL locations. This report discusses the details of these procedures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rapid Quality Assessment in Additive Manufacturing: New Procedure Accelerates Build Quality Assessment. White paper

Accelerated growth of the additive manufacturing (AM) industry in recent years is accompanied by a rising need for methods to quickly assess quality at-scale. Current practices for quality inspection include nondestructive test methods and destructive testing of witness coupons, which are artifacts built alongside the actual part. However, these methods can be costly and time-consuming. Recognizing this need, the Additive Manufacturing Center of Excellence (AM CoE) initiated a project led by its partner, Auburn University, to develop rapid testing procedure using asbuilt samples tested in torsion to quantitatively assess build quality. The presented work developed a rapid testing procedure using as-built samples tested in torsion to quantify small variances for assessing build quality.

42 ENGINEERING↗

Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in Bio-Oils: Laboratory Analytical Procedure (LAP)

The determination of total carbon, hydrogen, and nitrogen in bio-oils is important as these values can be used to track the carbon balance of production processes as well as calculate total oxygen content by difference. Oxygen content of bio-oils is a key metric for production and upgrading strategies as these are typically aimed at reducing oxygen. Oxygenates in bio-oils contribute to poor hydrocarbon miscibility, high acidity, high viscosity, and poor stability. Upgrading of bio-oils via deoxygenation produces hydrocarbons which can be used to generate feedstocks for renewable fuels and chemicals. In this Laboratory Analytical Procedure (LAP), combustion-based ultimate analysis is used to determine the weight percent (wt%) of C, H, and N in bio-oils and upgraded products. Ultimate analysis uses high temperatures and a pure oxygen environment to completely combust organic samples to carbon dioxide (CO 2 ), water (H 2 O), and nitrogen oxides (NO x ). In this procedure the amount of C and H in the sample are quantified by measuring resultant CO 2 and H 2 O with Fourier-transform infrared spectroscopy (FTIR). For N, NO x is reduced to nitrogen (N 2 ) which is measured with a thermal conductivity detector (TCD), providing total N content.

09 BIOMASS FUELS↗

Determination of Water Content in Bio-Oils by Volumetric Karl Fischer Titration: Laboratory Analytical Procedure (LAP)

The water content of bio-oils is a key metric for several reasons. Water is typically the most concentrated single component of fast pyrolysis oils, though this will be much lower in catalytic fast pyrolysis and upgraded products. Reduced water content is preferable in bio-oil as water can contribute to phase separation, corrosivity, and instability. Additionally, lower water is beneficial for physical properties such as energy density. The percentage of water can also be used to correct the calculation for organic oxygen when determining total oxygen content of bio-oils via combustion-based ultimate analysis. The procedure described here is specifically written for the analysis of bio-oils, and is based on ASTM E203, Standard Test Method for Water Using Volumetric Karl Fischer Titration. This standard test method is specified for measuring the mass % water in pyrolysis liquid biofuels in ASTM D7544, Standard Specification for Pyrolysis Liquid Biofuel. Although the standard method is prescribed for the analysis of pyrolysis liquids for use in industrial and commercial burners, the method is not specifically written for this product. The method described with this Laboratory Analytical Procedure (LAP) provides specific guidance for the analysis of bio-oils. Both organic and aqueous phases can be measured with this technique.

09 BIOMASS FUELS↗

Home Energy Professionals Certifications ISO/IEC 17024: 2021 Policies and Procedures Manual

The U.S. Department of Energy (DOE) enlisted its National Renewable Energy Laboratory (NREL) to coordinate the development of a framework for new certifications in the weatherization and home performance industry. The Home Energy Professional certifications support DOE's Weatherization Assistance Program (WAP) and the broader residential home performance industry through the credentialing process of defined job task analysis for energy auditors and quality control inspectors. The HEP certifications are not intended to supplant or infringe upon any existing industry-recognized credentials, however, the WAP and the home performance industry have utilized the advanced HEP certifications to promote quality work and standardized job task analysis since 2010. On an ongoing basis, NREL brings industry practitioners and subject matter experts together to develop, review, and revise the certification schemes in accordance with the International Organization for Standardization (ISO)/International Electrotechnical Commission (IEC) 17024 standard, "Conformity assessment - General requirements for bodies operating certification of persons" (ISO/IEC 17024). This handbook covers the policies and procedures for the process of developing, maintaining, and validating the certification schemes. Each policy and procedure includes the relevant ISO/IEC 17024 section at the beginning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

RG217 V2-V2 Coaxial Cable Soldering Procedure

The ECSE Solid State Pulsed Power unit is a high-current, high power solid-state pulse modulator. The RG217 V2-V2 Coaxial Cable Assembly is the interface cable between the Solid State Pulser and the load. This document covers the soldering procedure for the RG217 V2-V2 Coaxial Cable Assembly. This assembly is comprised of RG217 Coaxial Cable with a LRU Connector on either end. This soldering procedure describes the process used to solder cable tips properly onto the cable center conductor.

42 ENGINEERING↗

RG217 V2-V2 Coaxial Cable Assembly Procedure

The ECSE Solid State Pulsed Power unit is a high-current, high power solid-state pulse modulator. The RG217 V2-V2 Coaxial Cable Assembly is the interface cable between the Solid State Pulser and the load. This document covers the assembly procedure for the RG217 V2-V2 Coaxial Cable Assembly. This assembly is comprised of RG217 Coaxial Cable with a LRU Connector on either end. This assembly procedure describes the process used to install cable connectors properly onto the cable.

42 ENGINEERING↗

Determination of Phenolic Groups in Bio-Oils Using Revised Folin-Ciocalteu Methods: Single Cuvette and Plate Reader. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Phenol components are ubiquitous in wood-derived bio-oils and biocrudes. Their reaction with other functional groups (e.g., aldehydes) may contribute to the formation of carbonaceous species and the expected thermal instability of pyrolysis oils. During hydrotreating, phenols can be recalcitrant species, requiring higher reaction temperatures than other oxygen-containing functional groups. Phenols are also present in upgraded products and have been shown to lead to catalyst deactivation during hydrotreating. They also are the first oxygenated functional group to re-appear in the upgraded product, signaling catalyst deactivation. This procedure covers the determination of phenolic compounds in fast pyrolysis oils. This Laboratory Analytical Procedure (LAP) includes two methods, the first allowing for shorter analysis time at increased reaction temperature, while the second employs a longer analysis time but at room temperature. Additionally, the use of both a single cuvette and of a plate reader are also presented.

09 BIOMASS FUELS↗