Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “planning optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Integration of Design Data Into Automated Fiber Placement Process Planning Metrics

With the ever-expanding aviation industry, a need is arising for more rapid production of composite aircraft to meet increasing demand. State-of-the-art aircraft such as the Boeing 787showcase 50% composite material usage by weight, highlighting this emerging industry-wide adoption of the material system. Currently, many of the large structures associated with these aircraft are manufactured additively via Automated Fiber Placement (AFP). The AFP process shows great potential for efficient manufacturing, however unavoidable defects still occur because of tool surface geometry, placement errors, or poor process planning, resulting in decreased quality and throughput. Due to such effects, it is critical to incorporate design for manufacturing (DFM) principles to achieve the optimal manufacturing plan and resulting structure. This work will develop a methodology for incorporating design information into process planning metrics in an automated fashion to achieve an optimal set of process inputs.The analysis incorporates HyperX, Computer Aided Process Planning (CAPP) and Vericut Composite Programming (VCP). Safety margins from HyperX are imported into CAPP where AFP defects are mapped to the values. The resulting margins are then incorporated into the CAPP manufacturability algorithms, creating a design informed process planning analysis

Automated Fiber Placement↗

Simultaneous {sup 68}Ga-DOTATOC-PET/MRI for IMRT Treatment Planning for Meningioma: First Experience

Purpose: To evaluate intensity-modulated radiotherapy (IMRT) treatment planning based on simultaneous positron-emission tomography and magnetic resonance imaging (PET/MRI) of meningioma. Methods and Materials: A meningioma patient was examined prior to radiotherapy with dedicated planning computed tomography (CT), MRI, PET/CT with gallium-68-labeled DOTATOC ({sup 68}Ga-DOTATOC), and simultaneous {sup 68}Ga-DOTATOC-PET/MRI. The first gross target volume (GTV) was defined based on a combination of separate MR and {sup 68}Ga-DOTATOC-PET/CT imaging (GTV{sub PET/CT+MR}). Then, the simultaneous PET/MR images were used to delineate a second GTV (GTV{sub PET/MR}) by following exactly the same delineation strategy. After an isotropic expansion of those volumes by a 4-mm safety margin, the resulting planning target volumes (PTVs) were compared by calculating the intersection volume and the relative complements. A cross-evaluation of IMRT plans was performed, where the treatment plan created for the PTV{sub PET/CT+MR} was applied to the PET/MR-based PTV{sub PET/MR}. Results: Generally, target volumes for IMRT treatment planning did not differ between MRI plus {sup 68}Ga-DOTATOC-PET/CT and simultaneous PET/MR imaging. Only in certain regions of the GTV were differences observed. The overall volume of the PET/MR-based PTV was approximately the same as that obtained from PET/CT data. A small region of infiltrative tumor growth next to the main tumor mass was better visualized with combined PET/MR due to smaller PET voxel sizes and improved recovery. An IMRT treatment plan was optimized for the PTV{sub PET/CT+MR}. The evaluation of this plan with respect to the PTV{sub PET/MR} showed parts of the target volume that would not have received the full radiation dose after delineation of the tumor, based on simultaneous PET/MR. Conclusion: This case showed that differences in target volumes delineated on the basis of separate MR and PET/CT and simultaneous PET/MR may be observed that can have significant consequences for an effectively applied radiotherapy treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy

The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in the phantom's cylindrical wall forming four rings of detectors. For coplanar beams, the cylindrical geometry and the ring diode pattern offer the advantage of invariant perpendicular incidence on the beam central axis for any gantry angle and also have the benefit of increasing the detector density as both walls of the cylinder sample the beam. Other advantages include real-time readout and reduced weight with the hollow phantom shape. A calibration method taking into account the variation in radiation sensitivity of the diodes as a function of gantry angle was developed and implemented. In this work, the new dosimeter system was used in integrating mode to perform composite dose measurements along the cylindrical surface supporting the diodes. The reproducibility of the dosimeter response and the angular dependence of the diodes were assessed using simple 6 MV photon static beams. The performance of the new dosimeter system for VMAT QA was then evaluated using VMAT plans designed for a head and neck, an abdominal sarcoma, and a prostate patient. These plans were optimized with 90 control points (CPs) and additional versions of each plan were generated by increasing the number of CPs to 180 and 360 using linear interpolation. The relative dose measured with the dosimeter system for the VMAT plans was compared to the corresponding TPS dose map in terms of relative dose difference (%{Delta}D) and distance to agreement (DTA). The dosimeter system's sensitivity to gantry rotation offset and scaling errors as well as setup errors was also evaluated. For static beams, the dosimeter system offered good reproducibility and demonstrated small residual diode angular dependence after calibration. For VMAT deliveries, the agreement between measured and calculated doses was good with {>=}86.4% of the diodes satisfying 3% of %{Delta}D or 2 mm DTA for the 180 CP plans. The phantom offered sufficient sensitivity for the detection of small gantry rotation offset (3 deg.) and scaling errors (1 deg.) as well as phantom setup errors of 1 mm, although the results were plan dependent. With its novel geometry, the dosimeter system was also able to experimentally demonstrate the discretization effect of the number of CPs used in the TPS to simulate a continuous arc. These results demonstrate the suitability of the new dosimeter system for the patient-specific QA of VMAT plans and suggest that the dosimeter system can be an effective tool in the routine QA and commissioning of treatment machines capable of VMAT delivery and cone-beam CT image guidance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-203: High Dose Definitive Proton Therapy with Integrated Boost to Hypoxic Subvolumes Determined by [18F]-Fluoromisonidazole (FMISO) PET/CT for Patients with Recurrent Chordomas Using Intensity Modulated Proton Therapy (IMPT)

Purpose: Recurrent chordomas are difficult to control locally. This dosimetric study investigates the feasibility of dose escalation to hypoxic regions, visualized on FMISO-PET, while respecting the dose constraints to the neighboring normal tissues/organs. We propose to deliver a higher dose to the areas of hypoxia (84.5Gy) using IMPT with the goal of improving local control. Methods: We currently have four patients with hypoxic subvolumes (HSV) greater than 10cc from the FMISO-PET image. The HSV was delineated based on the standardized uptake values of greater than 1.4 times of the muscle mean. Gross tumor volume (GTV) was delineated using planning CT with the assistance of MRI fusion. The dose scheme is 50.4Gy RBE to CTV in 1.8Gy fractions, followed by an integrated boost of 27.0Gy RBE to GTV in 1.8Gy fractions and 34.5Gy RBE to HSV in 2.3Gy fractions. IMPT integrated boost plans were optimized with multi-criteria optimization (MCO). Posterior-anterior beam angles were used for these plans. We also propose using two posterior oblique fields to boost HSV to spare the skin folding. A medium spot size with 8mm to 15 mm (σ) in air at isocenter with energies from 220 MeV down to 90 MeV was used. Aperture was used for the medium spot size. A small spot size of 2.5 mm to 4.5 mm (σ) in air at isocenter with energies from 240 MeV down to 70 MeV was also proposed. Target coverage and dose to OARs were evaluated. Results: For the sacral chordoma patient that has been planned, the target homogeneity index is 3.2% for HSV, 55.9% for CTV and 11.9% for GTV. The max dose is 77GyRBE to rectum, 86.2GyRBE to sacral nerves and 73.9GyRBE to cauda equina. Conclusion: IMPT with integrated high dose boost to HSV determined from FMISO PET image is feasible. OAR dose constraints were met.

60 APPLIED LIFE SCIENCES↗

SU-E-T-580: Comparison of Cervical Carcinoma IMRT Plans From Four Commercial Treatment Planning Systems (TPS)

Purpose: Different treatment planning systems (TPS) use different treatment optimization and leaf sequencing algorithms. This work compares cervical carcinoma IMRT plans optimized with four commercial TPSs to investigate the plan quality in terms of target conformity and delivery efficiency. Methods: Five cervical carcinoma cases were planned with the Corvus, Monaco, Pinnacle and Xio TPSs by experienced planners using appropriate optimization parameters and dose constraints to meet the clinical acceptance criteria. Plans were normalized for at least 95% of PTV to receive the prescription dose (Dp). Dose-volume histograms and isodose distributions were compared. Other quantities such as Dmin(the minimum dose received by 99% of GTV/PTV), Dmax(the maximum dose received by 1% of GTV/PTV), D100, D95, D90, V110%, V105%, V100% (the volume of GTV/PTV receiving 110%, 105%, 100% of Dp), conformity index(CI), homogeneity index (HI), the volume of receiving 40Gy and 50 Gy to rectum (V40,V50) ; the volume of receiving 30Gy and 50 Gy to bladder (V30,V50) were evaluated. Total segments and MUs were also compared. Results: While all plans meet target dose specifications and normal tissue constraints, the maximum GTVCI of Pinnacle plans was up to 0.74 and the minimum of Corvus plans was only 0.21, these four TPSs PTVCI had significant difference. The GTVHI and PTVHI of Pinnacle plans are all very low and show a very good dose distribution. Corvus plans received the higer dose of normal tissue. The Monaco plans require significantly less segments and MUs to deliver than the other plans. Conclusion: To deliver on a Varian linear-accelerator, the Pinnacle plans show a very good dose distribution. Corvus plans received the higer dose of normal tissue. The Monaco plans have faster beam delivery.

60 APPLIED LIFE SCIENCES↗

Dynamics Informed Optimization for Resilient Energy Systems

Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the Western System Coordinating Council (WSCC) 9-bus test system using synthetic multi-device outage scenarios. Towards integrating our modeling framework with real threats and more realistic power systems, we explore applying hybrid dynamics to power systems. Our work is applied to basic RL circuits with the ultimate goal of using the methodology to model protective tripping schemes in the grid. Finally, we survey mitigation techniques for HEMP threats and describe a GIS application developed to create threat scenarios in a grid with geographic detail.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A critical evaluation of worst case optimization methods for robust intensity-modulated proton therapy planning

Purpose: To critically evaluate and compare three worst case optimization methods that have been previously employed to generate intensity-modulated proton therapy treatment plans that are robust against systematic errors. The goal of the evaluation is to identify circumstances when the methods behave differently and to describe the mechanism behind the differences when they occur. Methods: The worst case methods optimize plans to perform as well as possible under the worst case scenario that can physically occur (composite worst case), the combination of the worst case scenarios for each objective constituent considered independently (objectivewise worst case), and the combination of the worst case scenarios for each voxel considered independently (voxelwise worst case). These three methods were assessed with respect to treatment planning for prostate under systematic setup uncertainty. An equivalence with probabilistic optimization was used to identify the scenarios that determine the outcome of the optimization. Results: If the conflict between target coverage and normal tissue sparing is small and no dose-volume histogram (DVH) constraints are present, then all three methods yield robust plans. Otherwise, they all have their shortcomings: Composite worst case led to unnecessarily low plan quality in boundary scenarios that were less difficult than the worst case ones. Objectivewise worst case generally led to nonrobust plans. Voxelwise worst case led to overly conservative plans with respect to DVH constraints, which resulted in excessive dose to normal tissue, and less sharp dose fall-off than the other two methods. Conclusions: The three worst case methods have clearly different behaviors. These behaviors can be understood from which scenarios that are active in the optimization. No particular method is superior to the others under all circumstances: composite worst case is suitable if the conflicts are not very severe or there are DVH constraints whereas voxelwise worst case is advantageous if there are severe conflicts but no DVH constraints. The advantages of composite and voxelwise worst case outweigh those of objectivewise worst case.

60 APPLIED LIFE SCIENCES↗

Fundamental Path Optimization Strategies for Extrusion-based Additive Manufacturing

Extrusion-based additive manufacturing processes begin with a software program, called a slicer, that generates layer geometry and fits toolpaths to each layer to define where material is to be extruded or deposited. Before the toolpaths are output as g-code for the additive manufacturing system to execute, the toolpaths should be optimized. Many complex optimization approaches using graph theory, Chinese postman problem, and other complex mathematical models exist, but these approaches are rarely used in daily printing operations and are not available through common slicing programs such as Cura and PrusaSlicer. Instead, path planning and optimization typically revolves around simpler, fully automated approaches such as inside out and next closest. This paper will explore the fundamental optimization strategies for toolpath planning and document a new implementation, available via open-source slicing software, that allows for greater control of the path planning process.

Roschli, Alex [ORNL] (ORCID:0000000213084632)↗

Dose-shaping using targeted sparse optimization

Purpose: Dose volume histograms (DVHs) are common tools in radiation therapy treatment planning to characterize plan quality. As statistical metrics, DVHs provide a compact summary of the underlying plan at the cost of losing spatial information: the same or similar dose-volume histograms can arise from substantially different spatial dose maps. This is exactly the reason why physicians and physicists scrutinize dose maps even after they satisfy all DVH endpoints numerically. However, up to this point, little has been done to control spatial phenomena, such as the spatial distribution of hot spots, which has significant clinical implications. To this end, the authors propose a novel objective function that enables a more direct tradeoff between target coverage, organ-sparing, and planning target volume (PTV) homogeneity, and presents our findings from four prostate cases, a pancreas case, and a head-and-neck case to illustrate the advantages and general applicability of our method.Methods: In designing the energy minimization objective (E{sub tot}{sup sparse}), the authors utilized the following robust cost functions: (1) an asymmetric linear well function to allow differential penalties for underdose, relaxation of prescription dose, and overdose in the PTV; (2) a two-piece linear function to heavily penalize high dose and mildly penalize low and intermediate dose in organs-at risk (OARs); and (3) a total variation energy, i.e., the L{sub 1} norm applied to the first-order approximation of the dose gradient in the PTV. By minimizing a weighted sum of these robust costs, general conformity to dose prescription and dose-gradient prescription is achieved while encouraging prescription violations to follow a Laplace distribution. In contrast, conventional quadratic objectives are associated with a Gaussian distribution of violations, which is less forgiving to large violations of prescription than the Laplace distribution. As a result, the proposed objective E{sub tot}{sup sparse} improves tradeoff between planning goals by 'sacrificing' voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E{sub tot}{sup sparse} occurs as a result. For example, large violations to dose prescription in the PTV in E{sub tot}{sup sparse}-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E{sub tot}{sup sparse}-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV's spatial dose distribution than conventional objective functions. In particular, E{sub tot}{sup sparse}-optimized plans for the pancreas case and head-and-neck case exhibited substantially improved sparing of the spinal cord and parotid glands, respectively, while maintaining or improving sparing for other OARs and markedly improving PTV homogeneity. Plan deliverability for E{sub tot}{sup sparse}-optimized plans was shown to be better than their associated clinical plans, according to the two-dimensional modulation index.Conclusions: These results suggest that our formulation may be used to improve dose-shaping and OAR-sparing for complicated disease sites, such as the pancreas or head and neck. Furthermore, our objective function and constraints are linear and constitute a linear program, which converges to the global minimum quickly, and can be easily implemented in treatment planning software. Thus, the authors expect fast translation of our method to the clinic where it may have a positive impact on plan quality for challenging disease sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimal carbon storage reservoir management through deep reinforcement learning

Model-based optimization plays a central role in energy system design and management. The complexity and high-dimensionality of many process-level models, especially those used for geosystem energy exploration and utilization, often lead to formidable computational costs when the dimension of decision space is also large. This work adopts elements of recently advanced deep learning techniques to solve a sequential decision-making problem in applied geosystem management. Specifically, a deep reinforcement learning framework was formed for optimal multiperiod planning, in which a deep Q-learning network (DQN) agent was trained to maximize rewards by learning from high-dimensional inputs and from exploitation of its past experiences. To expedite computation, deep multitask learning was used to approximate high-dimensional, multistate transition functions. Both DQN and deep multitask learning are pattern based. As a demonstration, the framework was applied to optimal carbon sequestration reservoir planning using two different types of management strategies: monitoring only and brine extraction. Both strategies are designed to mitigate potential risks due to pressure buildup. Results show that the DQN agent can identify the optimal policies to maximize the reward for given risk and cost constraints. Finally, experiments also show that knowledge the agent gained from interacting with one environment is largely preserved when deploying the same agent in other similar environments.

15 GEOTHERMAL ENERGY↗

Extracting and Generating PV Soiling Profiles for Analysis, Forecasting, and Cleaning Optimization

The identification and prediction of the daily soiling profiles of a photovoltaic site is essential to plan the optimal cleaning schedule. In this article, we analyze and propose various methods to extract and generate photovoltaic soiling profiles, in order to improve the analysis and the forecast of the losses. New soiling rate extraction methods are proposed to reflect the seasonal variability of the soiling rates and, for this reason, are found to identify the most convenient cleaning day with the highest accuracy for the investigated sites. Also, we present an approach that could be used to predict future soiling losses through the implementation of stochastic weather generation algorithms whose ability to identify in advance the best cleaning schedule is also successfully tested. The methods presented in this article can optimize the operation and maintenance schedule and could make it possible, in the future, to predict soiling losses through analysis based only on environmental parameters, such as rainfall and particulate matter, without the need of long-term soiling data.

14 SOLAR ENERGY↗

Robot path planning with obstacles, actuator, gripper, and payload constraints

A method is presented to obtain the time-optimal motions for robotic manipulators. It considers the full nonlinear dynamics of the manipulator, its actuator saturation limits, and gripper and payload constraints. It also accounts for both the presence of obstacles in the work space and restrictions on the motion of the manipulator's joints. The method is computationally practical and has been implemented for the optimal trajectory planning of general six degree-of-freedom manipulators. Examples are presented that demonstrate the substantial improvement in manipulator performance that can be achieved using this method.

Shiller, Zvi↗

Integrated path planning and control through proximal policy optimization for a marine current turbine

This paper presents an integrated path planning and tracking control framework for a marine current turbine (MCT), where the MCT is treated as an energy-harvesting autonomous underwater vehicle (AUV). Considering the ocean (space of action) is continuous, the proposed framework employs two modules to address path planning and path tracking enabled by the proximal policy optimization (PPO) algorithm, which is a policy gradient deep reinforcement learning (RL) method. Further, to enable fully autonomous operation in a stochastic oceanic environment, the proposed path planning seeks a primary objective of maximizing the harvested energy; then, the path tracking module is designed to minimize the tracking error and avoid collisions with static and dynamic obstacles. Using field-collected acoustic Doppler current profiler (ADCP) data, the performance of the proposed framework is evaluated. Comparative studies with baseline algorithms in three different scenarios of path planning, path tracking without an obstacle, and path tracking with collision avoidance verify the effectiveness of our proposed approach.

16 TIDAL AND WAVE POWER↗

Whole Brain Radiotherapy With Hippocampal Avoidance and Simultaneous Integrated Boost for 1-3 Brain Metastases: A Feasibility Study Using Volumetric Modulated Arc Therapy

Purpose: To evaluate the feasibility of using volumetric modulated arc therapy (VMAT) to deliver whole brain radiotherapy (WBRT) with hippocampal avoidance and a simultaneous integrated boost (SIB) for one to three brain metastases. Methods and Materials: Ten patients previously treated with stereotactic radiosurgery for one to three brain metastases underwent repeat planning using VMAT. The whole brain prescription dose was 32.25 Gy in 15 fractions, and SIB doses to brain metastases were 63 Gy to lesions >=2.0 cm and 70.8 Gy to lesions <2.0 cm in diameter. The mean dose to the hippocampus was kept at <6 Gy{sub 2}. Plans were optimized for conformity and target coverage while minimizing hippocampal and ocular doses. Plans were evaluated on target coverage, prescription isodose to target volume ratio, conformity number, homogeneity index, and maximum dose to prescription dose ratio. Results: Ten patients had 18 metastases. Mean values for the brain metastases were as follows: conformity number = 0.73 +- 0.10, target coverage = 0.98 +- 0.01, prescription isodose to target volume = 1.34 +- 0.19, maximum dose to prescription dose ratio = 1.09 +- 0.02, and homogeneity index = 0.07 +- 0.02. For the whole brain, the mean target coverage and homogeneity index were 0.960 +- 0.002 and 0.39 +- 0.06, respectively. The mean hippocampal dose was 5.23 +- 0.39 Gy{sub 2}. The mean treatment delivery time was 3.6 min (range, 3.3-4.1 min). Conclusions: VMAT was able to achieve adequate whole brain coverage with conformal hippocampal avoidance and radiosurgical quality dose distributions for one to three brain metastases. The mean delivery time was under 4 min.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvements in Critical Dosimetric Endpoints Using the Contura Multilumen Balloon Breast Brachytherapy Catheter to Deliver Accelerated Partial Breast Irradiation: Preliminary Dosimetric Findings of a Phase IV Trial

Purpose: Dosimetric findings in patients treated with the Contura multilumen balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional Phase IV registry trial are presented. Methods and Materials: Computed tomography-based three-dimensional planning with dose optimization was performed. For the trial, new ideal dosimetric goals included (1) {>=}95% of the prescribed dose (PD) covering {>=}90% of the target volume, (2) a maximum skin dose {<=}125% of the PD, (3) maximum rib dose {<=}145% of the PD, and (4) the V150 {<=}50 cc and V200 {<=}10 cc. The ability to concurrently achieve these dosimetric goals using the Contura MLB was analyzed. Results: 144 cases were available for review. Using the MLB, all dosimetric criteria were met in 76% of cases. Evaluating dosimetric criteria individually, 92% and 89% of cases met skin and rib dose criteria, respectively. In 93% of cases, ideal target volume coverage goals were met, and in 99%, dose homogeneity criteria (V150 and V200) were satisfied. When skin thickness was {>=}5 mm to <7 mm, the median skin dose was limited to 120.1% of the PD, and when skin thickness was <5 mm, the median skin dose was 124.2%. When rib distance was <5 mm, median rib dose was reduced to 136.5% of the PD. When skin thickness was <7 mm and distance to rib was <5 mm, median skin and rib doses were jointly limited to 120.6% and 142.1% of the PD, respectively. Conclusion: The Contura MLB catheter provided the means of achieving the imposed higher standard of dosimetric goals in the majority of clinical scenarios encountered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc stereotactic treatments

Purpose: To assess the accuracy against measurements of two photon dose calculation algorithms (Acuros XB and the Anisotropic Analytical algorithm AAA) for small fields usable in stereotactic treatments with particular focus on RapidArc. Methods: Acuros XB and AAA were configured for stereotactic use. Baseline accuracy was assessed on small jaw-collimated open fields for different values for the spot sizes parameter in the beam data: 0.0, 0.5, 1, and 2 mm. Data were calculated with a grid of 1 x 1 mm{sup 2}. Investigated fields were: 3 x 3, 2 x 2, 1 x 1, and 0.8 x 0.8 cm{sup 2} with a 6 MV photon beam generated from a Clinac2100iX (Varian, Palo Alto, CA). Profiles, PDD, and output factors were measured in water with a PTW diamond detector (detector size: 4 mm{sup 2}, thickness 0.4 mm) and compared to calculations. Four RapidArc test plans were optimized, calculated and delivered with jaw settings J3 x 3, J2 x 2, and J1 x 1 cm{sup 2}, the last was optimized twice to generate high (H) and low (L) modulation patterns. Each plan consisted of one partial arc (gantry 110 deg. to 250 deg.), and collimator 45 deg. Dose to isocenter was measured in a PTW Octavius phantom and compared to calculations. 2D measurements were performed by means of portal dosimetry with the GLAaS method developed at authors' institute. Analysis was performed with gamma pass-fail test with 3% dose difference and 2 mm distance to agreement thresholds. Results: Open square fields: penumbrae from open field profiles were in good agreement with diamond measurements for 1 mm spot size setting for Acuros XB, and between 0.5 and 1 mm for AAA. Maximum MU difference between calculations and measurements was 1.7% for Acuros XB (0.2% for fields greater than 1 x 1 cm{sup 2}) with 0.5 or 1 mm spot size. Agreement for AAA was within 0.7% (2.8%) for 0.5 (1 mm) spot size. RapidArc plans: doses were evaluated in a 4 mm diameter structure at isocenter and computed values differed from measurements by 0.0, -0.2, 5.5, and -3.4% for Acuros XB calculations (1 mm spot size), and of -0.1, 0.3, 6.7, and -1.2% for AAA, respectively for J3 x 3, J2 x 2, J1 x 1H, J1 x 1L RapidArc plans. Gamma Agreement Index from 2D dose analysis was higher than 95% for J3 x 3 and J2 x 2 plans, being around 80% for J1 x 1 maps. Sensitivity with respect to the dosimetric leaf gap and transmission factor MLC parameters was evaluated in the four RapidArc plans, showing the need to properly set the dosimetric leaf gap for accurate calculations. Conclusions: Acuros XB and AAA showed acceptable characteristics for stereotactic small fields if adequate tuning of configuration parameters is performed. Dose calculated for RapidArc stereotactic plans showed an acceptable agreement against point and 2D measurements. Both algorithms can therefore be considered safely applicable to stereotactic treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-109: Development of An End-To-End Test for the Varian TrueBeamtm with a Novel Multiple-Dosimetric Modality H and N Phantom

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Methods: The initial end-to-end test and custom H and N phantom were designed to yield maximum information in anatomical regions significant to H and N plans with respect to: i) geometric accuracy, ii) dosimetric accuracy, and iii) treatment reproducibility. The phantom was designed in collaboration with Integrated Medical Technologies. A CT image was taken with a 1mm slice thickness. The CT was imported into Varian's Eclipse treatment planning system, where OARs and the PTV were contoured. A clinical template was used to create an eight field static gantry angle IMRT plan. After optimization, dose was calculated using the Analytic Anisotropic Algorithm with inhomogeneity correction. Plans were delivered with a TrueBeam equipped with a high definition MLC. Preliminary end-to-end results were measured using film and ion chambers. Ion chamber dose measurements were compared to the TPS. Films were analyzed with FilmQAPro using composite gamma index. Results: Film analysis for the initial end-to-end plan with a geometrically simple PTV showed average gamma pass rates >99% with a passing criterion of 3% / 3mm. Film analysis of a plan with a more realistic, ie. complex, PTV yielded pass rates >99% in clinically important regions containing the PTV, spinal cord and parotid glands. Ion chamber measurements were on average within 1.21% of calculated dose for both plans. Conclusion: trials have demonstrated that our end-to-end testing methods provide baseline values for the dosimetric and geometric accuracy of Varian's TrueBeam system.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-04: Comparison of Coplanar VMAT, Non-Coplanar VMAT, and 4π Treatment Plans

Purpose: The 4π non-coplanar radiotherapy delivery technique has demonstrated significantly better normal tissue sparing and dose conformality than the clinically used volumetric modulated arc therapy (VMAT). It is unclear whether this is a fundamental limitation of VMAT delivery or the coplanar nature of its typical clinical plans. The non-coplanar basis of 4π is incorporated into VMAT treatment planning to compare its effect on plan quality. Methods: Clinical stereotactic body radiation therapy plans for 9 liver patients treated with 30–60 Gy using coplanar VMAT (cVMAT) were re-planned using non-coplanar VMAT (nVMAT) with 3 arcs and 4 π with 20 intensity-modulated non-coplanar fields. All plans were optimized to deliver 100% of the prescribed dose to 95% of the planning target volume (PTV), and nVMAT and 4π plans were tailored to match the maximum and mean PTV dose from the clinical plan. The conformality index (CI), 50% dose spillage volume (R50), normal liver volume receiving >15 Gy (VL>15), and doses to organs at risk (OARs) were compared for all three treatment plans. Results: Compared to cVMAT, the nVMAT and 4π plans reduced VL>15 by an average of 30.6 cm3 and 96.3 cm3, respectively. The average CI was also reduced from 1.22 (cVMAT) to 1.17 (nVMAT) and 1.14 (4π), indicating higher conformality in the same order. Similarly, R50 was reduced from 3.87 (cVMAT) to 3.58 (nVMAT) and 2.74 (4π). With the exception of the mean right kidney dose, which increased by an average of only 0.6 Gy for nVMAT, the dose differences to OARs were not statistically significant between the two VMAT plans. 4π plans either significantly decreased or maintained OAR doses. Conclusion: While the manual selection of intuitive non-coplanar arcs does show some improvement over coplanar VMAT, the automated beam selection for 4π still results in superior plan quality. This project is supported in part by Varian Medical Systems and NIH R43 CA183390.

60 APPLIED LIFE SCIENCES↗