Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “physics of failure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Fault-tolerant quantum computation with probabilistic two-qubit gates

A scheme for fault-tolerant quantum computation (FTQC) with probabilistic two-qubit gates is proposed. The error thresholds for FTQC are estimated by numerical simulations, where the conditional error probability (the error probability under the condition of 'success') is taken into account in addition to the failure probability. As a result, it turns out that FTQC is possible even if the failure probability is as high as 10% (5%) under the condition that the conditional error probability is lower than about 0.03% (0.3%). These results mean that the present scheme has a great advantage in using probabilistic two-qubit gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for New Physics in a Final State with Same-Sign Dileptons, Jets, and Missing Transverse Energy at 7 TeV Center of Mass Energy

We report on a search for new physics in a final state with two same sign leptons, missing transverse energy, and significant hadronic activity at a center of mass energy $\sqrt{s}$ = 7 TeV. The data were collected with the CMS detector at the CERN LHC and correspond to an integrated luminosity of 0.98 $\mathrm{fb}^{-1}$. Data--driven methods are developed to estimate the dominant Standard Model backgrounds. No evidence for new physics is observed. The dominant background to the analysis comes from failures of lepton identification in Standard Model $t\bar{t}$ events. The $t\bar{t}$ production cross section in the dilepton final state is measured using 3.1 $\mathrm{fb}^{-1}$ of data. The cross section is measured to be 194 $\pm$ 72 (stat) $\pm$ 24 (syst) $\pm$ 21 (lumi) pb. An algorithm is developed that uses tracking information to improve the reconstruction of missing transverse energy. The reconstruction of missing transverse energy is commissioned using the first collisio ns recorded at 0.9, 2.36 and 7 TeV data. Events with abnormally large values of missing transverse energy are identified as arising from anomalous signals in the calorimeters. Tools are developed to identify and remove these anomalous signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Methods for the Safe Storage, Handling, and Disposal of Pyrophoric Liquids and Solids in the Laboratory

Due to the inherent nature of pyrophoric substances to ignite spontaneously upon exposure to air, special precautions must be taken to ensure their safe handling and use. Pyrophoric gases (such as diborane, dichloroborane, phosphine, etc.) are typically the easiest class of pyrophoric substances to handle since the gas can be plumbed directly to the application and used remotely. Pyrophoric solids and liquids, however, require the user to physically manipulate them when transferring them from one container to another. Failure to follow proper safety precautions could result in serious injury or unintended consequences to laboratory personnel.12 Because of this danger, pyrophorics should be handled only by experienced personnel. Users with limited experience must be trained on how to handle pyrophoric reagents and consult with a knowledgeable staff member prior to performing the experimental task. The purpose of this article is three fold: 1) to provide guidelines and general safety precautions to avoid accidents, 2) describe proper techniques on how to successfully handle, store, and dispose of pyrophoric liquids and solids, and 3) illustrate best practices for working with this class of reactants in a laboratory environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inverse Relationship Between Biochemical Outcome and Acute Toxicity After Image-Guided Radiotherapy for Prostate Cancer

Purpose: Prostate cancer patients exhibit variability in normal tissue reactions and biochemical failure. With the use of image-guided radiotherapy (IGRT), there is a greater likelihood that the differences in normal tissue and tumor response are due to biological rather than physical factors. We tested the hypothesis that prospectively scored acute toxicity is associated with biochemical failure-free rate (BFFR) in prostate cancer patients treated with IGRT. Methods and Materials: We retrospectively analyzed BFFR in 362 patients with localized prostate cancer treated with IGRT. We compared BFFR with prospectively collected Radiation Therapy Oncology Group (RTOG) maximum acute gastrointestinal (GI) and genitourinary (GU) toxicity scores. Median follow-up for all patients was 58.3 months after total radiotherapy doses of 75.6-79.8 Gy. Results: Patients reporting RTOG acute GU or GI toxicity scores of {>=}2 were considered 'sensitive' (n = 141, 39%) and patients reporting scores <2 were considered 'nonsensitive' (n = 221, 61%). When calculating biochemical failure (BF) using the American Society for Therapeutic Radiology and Oncology definition at 5 years, 76% (CI 70-82%) of the 'nonsensitive' patients were failure free, compared with only 53% (CI 43-62%) of the 'sensitive' patients (log-rank test, p < 0.0001). This difference was also observed using the Phoenix definition; 'nonsensitive' 5-year BFFR was 81% (CI 74-86%) vs. 'sensitive' BFFR was 68% (CI 58-76%; log-rank test p = 0.0012). The difference in BF between cohorts remained significant when controlled for radiation dose (75.6 vs. 79.8 Gy), prognostic stratification (T category, prostate-specific antigen, and Gleason score), and prostate volume. Conclusions: This study unexpectedly shows that prostate cancer patients who develop {>=}Grade 2 RTOG acute toxicity during radiotherapy are less likely to remain BFF at 5 years. These results deserve further study and, if validated in other large IGRT cohorts, additional models would be required to study interaction between normal tissue and tumor biology in prostate cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the Insoluble Solids of the 241-17F and 241-49H Pump house Water Sample

Six different water samples from 241-17F and 241-49H pump house were analyzed for chemical and physical characteristics as part of efforts to understand recent mechanical seal failures associated with four new cooling water pumps. A focus of this work was characterization of any “as found” insoluble solids. The insoluble material found in the FCRW (F-Area caustic water treated with sodium chromate at 241-17F) sample are mostly magnetite (Fe3O4 or possibly equipment rust) and silica. It was found that 26% of measured FCRW particles have at least one dimension larger than 15 microns. The insoluble particles found in the source water, domestic water (FDW), are mostly kaolin (aluminosilicate) and some iron oxide. All found FDW particles were larger than 15 microns. The insoluble particles of the other source water, FArea well water (FWW), were mostly iron oxide with some trapped cations like calcium. Only 8% of found FWW particles were bigger than 15 microns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Cyber-Physical False Data Attack Detection in Smart Grids Using Neural Networks

Attacks on cyber-physical systems have recently increased in frequency, impact, and publicity. In this paper, a cyber-physical false data attack detection mechanism is proposed to protect the operation of power transmission and distribution systems by automatically inferring underlying physical relationships using cross-sensor analytics in order to detect sensor failures, replay attacks, and other data integrity issues in real-time. We investigate a neural network based mechanism acting on voltage and current readings resulting from a wide variety of load conditions on the IEEE 30-bus power system standard and compare its performance with a support vector machine based mechanism. Experiments showed that 99% detection accuracy of replay attacks was achieved using the proposed neural network mechanism. More importantly, we showed that the best approach was to not create physics-based features using what we knew about the system, but rather to use a neural network to automatically learn the laws, and then use the outputs of that to build a classifier to identify whether and where data spoofing occurs. Thus, it is preferable to infer and exploit the physics using a single machine learning solution

Ferragut, Erik M.↗

Wind Turbine Drivetrain Reliability Research - Gearbox Bearing Axial Cracking Failure Mode Example

The U.S. Department of Energy's National Renewable Energy Laboratory and Argonne National Laboratory have been conducting wind turbine drivetrain (formerly gearbox) reliability research for many years. Although the drivetrain focus has not changed, detailed projects are adjusted every few years based on dynamic needs seen in the field across the wind industry. This webinar will walk through the research methodology by using wind turbine gearbox bearing axial cracking failure mode as an example. The detailed steps include: 1) top failure mode identification based on actual failure data collected from project partners, 2) bench-top testing to identify possible contributing factors and formulate a damage metric, 3) physics domain modeling and validation through testing, 4) reliability assessment and prognosis based on the physics domain model and data domain inputs, and further enhancement through machine learning algorithms, using actual wind plant operational and failure event data. Hopefully, the presented work is of interest to the IISE community, and some members can apply their expertise to wind turbine and plant applications, helping enhance wind power generation technology advancement and its broader deployment.

axial cracking↗

Cyber-Informed Engineering Principles: What’s in it for me?

CIE is an emerging method to integrate cybersecurity considerations into the conception, design, development, and operation of any physical system that has digital connectivity, monitoring, or control. CIE complements—but does not replace—the application of cybersecurity standards or practices currently in place within an organization. Rather, it expands cybersecurity decisions into the engineering space, not by asking engineers to become cyber experts, but by calling on engineers to apply engineering tools and make engineering decisions that improve cybersecurity outcomes. CIE examines the engineering consequences that a sophisticated cyber attacker could achieve, and drives engineering changes that may provide deterministic mitigations to limit or eliminate those consequences. Engineers and technicians that design critical energy infrastructure installations can integrate the 12 principles of CIE into each phase of the engineering lifecycle, from concept to retirement. These principles are aimed at system or design engineers, operators, and technicians, rather than software engineers or operational cybersecurity practitioners, because the engineers who design, build, operate, and maintain the physical infrastructure are best positioned to leverage a system’s engineering design to diminish the severity of cyber attacks or digital technology failures. This approach creates new opportunities for engineering teams—and not just cybersecurity teams—to secure the system using the physics and mechanics of engineering controls—not just digital monitoring and controls.

99 GENERAL AND MISCELLANEOUS↗

DWPF Melter Off-Gas Chemistry Model for the Nitric-Glycolic Acid Flowsheet

The Defense Waste Processing Facility (DWPF) melter off-gas flammability model for the current nitric- formic acid (NFA) flowsheet was revised in Revision 0 to reflect the upcoming reductant change from formic to glycolic acid. The necessary data for the model revision was obtained during Phase 2 of the Cold-cap Evaluation Furnace (CEF) test, which was completed on March 21, 2014 after 24 days of round-the-clock feeding and pouring, including a total downtime of ~20 hours due to equipment failures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Security Analysis of Smart Grid Cyber Physical Infrastructures Using Modeling and Game Theoretic Simulation

Cyber physical computing infrastructures typically consist of a number of sites are interconnected. Its operation critically depends both on cyber components and physical components. Both types of components are subject to attacks of different kinds and frequencies, which must be accounted for the initial provisioning and subsequent operation of the infrastructure via information security analysis. Information security analysis can be performed using game theory implemented in dynamic Agent Based Game Theoretic (ABGT) simulations. Such simulations can be verified with the results from game theory analysis and further used to explore larger scale, real world scenarios involving multiple attackers, defenders, and information assets. We concentrated our analysis on the electric sector failure scenarios and impact analyses by the NESCOR Working Group Study, From the Section 5 electric sector representative failure scenarios; we extracted the four generic failure scenarios and grouped them into three specific threat categories (confidentiality, integrity, and availability) to the system. These specific failure scenarios serve as a demonstration of our simulation. The analysis using our ABGT simulation demonstrates how to model the electric sector functional domain using a set of rationalized game theoretic rules decomposed from the failure scenarios in terms of how those scenarios might impact the cyber physical infrastructure network with respect to CIA.

Availability↗

Distribution of blackouts in the power grid and the Motter and Lai model

Carreras, Dobson, and colleagues have studied empirical data on the sizes of the blackouts in real grids and modeled them with computer simulations using the direct current approximation. They have found that the resulting blackout sizes are distributed as a power law and suggested that this is because the grids are driven to the self-organized critical state. In contrast, more recent studies found that the distribution of cascades is bimodal resulting in either a very small blackout or a very large blackout, engulfing a finite fraction of the system. Here we reconcile the two approaches and investigate how the distribution of the blackouts changes with model parameters, including the tolerance criteria and the dynamic rules of failure of the overloaded lines during the cascade. Finally, we study the same problem for the Motter and Lai model and find similar results, suggesting that the physical laws of flow on the network are not as important as network topology, overload conditions, and dynamic rules of failure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient high-temperature reverse osmosis desalination membranes

Conventional thin-film composite (TFC) reverse osmosis (RO) membranes experience irreversible performance loss at high temperatures, restricting their use in industries with high-temperature streams, including oil and gas, pharmaceuticals, electronics, power generation, food production, and hybrid desalination plants. However, the mechanisms driving the performance decline of TFC membranes at high temperatures remain poorly understood. Herein, we combine controlled experiments, molecular dynamics simulations, and micromechanical modeling to elucidate TFC failure mechanisms and to evaluate thermally resilient thin-film cross-linked (TFX) composite membrane. Upon exposure to elevated temperatures (>60°C), salt rejection of TFC dropped from ~99 to <90%, with irreversible structural damage in the polysulfone layer, confirmed by scanning electron microscopy. In contrast, the TFX membrane maintained ~99% salt rejection and showed no signs of physical degradation up to 80°C. Our combined analyses revealed that TFC membrane failure arises from irreversible pore expansion in the thermoplastic polysulfone support, leading to polyamide film rupture and delamination. TFX membranes resist thermal deformation, enabling ultrahigh-temperature RO desalination and water reuse.

Wu, Jishan [Rice Univ., Houston, TX (United States↗

Memory Circuit Fault Simulator

Spacecraft are known to experience significant memory part-related failures and problems, both pre- and postlaunch. These memory parts include both static and dynamic memories (SRAM and DRAM). These failures manifest themselves in a variety of ways, such as pattern-sensitive failures, timingsensitive failures, etc. Because of the mission critical nature memory devices play in spacecraft architecture and operation, understanding their failure modes is vital to successful mission operation. To support this need, a generic simulation tool that can model different data patterns in conjunction with variable write and read conditions was developed. This tool is a mathematical and graphical way to embed pattern, electrical, and physical information to perform what-if analysis as part of a root cause failure analysis effort.

Sheldon, Douglas J.↗

Methodology for the Incorporation of Passive Component Aging Modeling into the RAVEN/ RELAP-7 Environment

Passive system, structure and components (SSCs) will degrade over their operation life and this degradation may cause to reduction in the safety margins of a nuclear power plant. In traditional probabilistic risk assessment (PRA) using the event-tree/fault-tree methodology, passive SSC failure rates are generally based on generic plant failure data and the true state of a specific plant is not reflected realistically. To address aging effects of passive SSCs in the traditional PRA methodology [1] does consider physics based models that account for the operating conditions in the plant, however, [1] does not include effects of surveillance/inspection. This paper represents an overall methodology for the incorporation of aging modeling of passive components into the RAVEN/RELAP-7 environment which provides a framework for performing dynamic PRA. Dynamic PRA allows consideration of both epistemic and aleatory uncertainties (including those associated with maintenance activities) in a consistent phenomenological and probabilistic framework and is often needed when there is complex process/hardware/software/firmware/ human interaction [2]. Dynamic PRA has gained attention recently due to difficulties in the traditional PRA modeling of aging effects of passive components using physics based models and also in the modeling of digital instrumentation and control systems. RAVEN (Reactor Analysis and Virtual control Environment) [3] is a software package under development at the Idaho National Laboratory (INL) as an online control logic driver and post-processing tool. It is coupled to the plant transient code RELAP-7 (Reactor Excursion and Leak Analysis Program) also currently under development at INL [3], as well as RELAP 5 [4]. The overall methodology aims to: • Address multiple aging mechanisms involving large number of components in a computational feasible manner where sequencing of events is conditioned on the physical conditions predicted in a simulation environment such as RELAP-7. • Identify the risk-significant passive components, their failure modes and anticipated rates of degradation • Incorporate surveillance and maintenance activities and their effects into the plant state and into component aging progress. • Asses aging affects in a dynamic simulation environment 1. C. L. SMITH, V. N. SHAH, T. KAO, G. APOSTOLAKIS, “Incorporating Ageing Effects into Probabilistic Risk Assessment –A Feasibility Study Utilizing Reliability Physics Models,” NUREG/CR-5632, USNRC, (2001). 2. T. ALDEMIR, “A Survey of Dynamic Methodologies for Probabilistic Safety Assessment of Nuclear Power Plants, Annals of Nuclear Energy, 52, 113-124, (2013). 3. C. RABITI, A. ALFONSI, J. COGLIATI, D. MANDELLI and R. KINOSHITA “Reactor Analysis and Virtual Control Environment (RAVEN) FY12 Report,” INL/EXT-12-27351, (2012). 4. D. ANDERS et.al, "RELAP-7 Level 2 Milestone Report: Demonstration of a Steady State Single Phase PWR Simulation with RELAP-7," INL/EXT-12-25924, (2012).

97 MATHEMATICS AND COMPUTING↗

Constitutive behavior and progressive mechanical failure of electrodes in lithium-ion batteries

The electrodes of lithium-ion batteries (LIB) are known to be brittle and to fail earlier than the separators during an external crush event. Thus, the understanding of mechanical failure mechanism for LIB electrodes (anode and cathode) is critical for the safety design of LIB cells. In this paper, we present experimental and numerical studies on the constitutive behavior and progression of failure in LIB electrodes. Mechanical tests were designed and conducted to evaluate the constitutive properties of porous electrodes. Constitutive models were developed to describe the stress-strain response of electrodes under uniaxial tensile and compressive loads. The failure criterion and a damage model were introduced to model their unique tensile and compressive failure behavior. The failure mechanism of LIB electrodes was studied using the blunt rod test on dry electrodes, and numerical models were built to simulate progressive failure. The different failure processes were examined and analyzed in detail numerically, and correlated with experimentally observed failure phenomena. Finally, the test results and models improve our understanding of failure behavior in LIB electrodes, and provide constructive insights on future development of physics-based safety design tools for battery structures under mechanical abuse.

25 ENERGY STORAGE↗

TU-FG-201-01: 18-Month Clinical Experience of a Linac Daily Quality Assurance (QA) Solution Using Only EPID and OBI

Purpose: To describe the clinical use of a Linear Accelerator (Linac) DailyQA system with only EPID and OBI. To assess the reliability over an 18-month period and improve the robustness of this system based on QA failure analysis. Methods: A DailyQA solution utilizing an in-house designed phantom, combined EPID and OBI image acquisitions, and a web-based data analysis and reporting system was commissioned and used in our clinic to measure geometric, dosimetry and imaging components of a Varian Truebeam Linac. During an 18-month period (335 working days), the Daily QA results, including the output constancy, beam flatness and symmetry, uniformity, TPR20/10, MV and KV imaging quality, were collected and analyzed. For output constancy measurement, an independent monthly QA system with an ionization chamber (IC) and annual/incidental TG51 measurements with ADCL IC were performed and cross-compared to Daily QA system. Thorough analyses were performed on the recorded QA failures to evaluate the machine performance, optimize the data analysis algorithm, adjust the tolerance setting and improve the training procedure to prevent future failures. Results: A clinical workflow including beam delivery, data analysis, QA report generation and physics approval was established and optimized to suit daily clinical operation. The output tests over the 335 working day period cross-correlated with the monthly QA system within 1.3% and TG51 results within 1%. QA passed with one attempt on 236 days out of 335 days. Based on the QA failures analysis, the Gamma criteria is revised from (1%, 1mm) to (2%, 1mm) considering both QA accuracy and efficiency. Data analysis algorithm is improved to handle multiple entries for a repeating test. Conclusion: We described our 18-month clinical experience on a novel DailyQA system using only EPID and OBI. The long term data presented demonstrated the system is suitable and reliable for Linac daily QA.

60 APPLIED LIFE SCIENCES↗