Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Microstructural Insights into Performance Loss of High-Voltage Spinel Cathodes for Lithium-ion Batteries

Spinel-structured LiNi x Mn 2-x O 4 (LNMO), with low-cost earth-abundant constituents, is a promising high-voltage cathode material for lithium-ion batteries. Even though extensive electrochemical investigations have been conducted on these materials, few studies have explored correlations between their loss in performance and associated changes in microstructure. Here, down to the atomic scale, the structural evolution of these materials is investigated upon the progressive cycling of lithium-ion cells. Transgranular cracking is revealed to be a key feature during cycling; this cracking is initiated at the particle surface and leads to the penetration of electrolytes along the crack path, thereby increasing particle exposure to the electrolyte. The lattice structure on the crack surface shows spatial variances, featuring a top layer of rock-salt, a sublayer of a Mn 3 O 4 -like arrangement, and then a mixed-cation region adjacent to the bulk lattice. The transgranular cracking, along with the emergence of local lattice distortion, becomes more evident with extended cycling. Further, phase transformation at primary particle surfaces and void formation through vacancy condensation is found in the cycled samples. All these features collectively contribute to the performance degradation of the battery cells during electrochemical cycling.

25 ENERGY STORAGE↗

Active Lithium Injection for a Real Time Control of the Divertor Heat Flux for Fusion Devices

When the local heat flux exceeds specified flux limit, tungsten PFC surfaces can be damaged, which is not acceptable for a reliable reactor operations. The divertor PFCs are typically designed for a specific heat flux limit usually assuming an average steady-state heat flux which is typically 5–10 MW/m 2 . However, in addition to steady-state heat flux, fusion reactor divertor PFCs could experience transient heat fluxes such as ELMs and/or other magnetic reconnection events which can deposit large transient heat fluxes onto the divertor PFCs. The transient divertor heat flux could be significantly larger than the steady-state heat flux which could damage the solid PFC surfaces. The divertor heat flux can be subjected to additional complications such as the uncertainties in the the divertor strike point heat flux projection. Moreover, there are additional experimental observations of non-axisymmetric power flux which can occur under non-axisymmetric magnetic perturbations. The liquid lithium (LL) PFCs is more resilient against such transient heat fluxes as they could evaporate LL as needed and the lost LL can be then replenished afterward. In this paper, we analyze a case for a transient divertor heat pulse of 1 MJ in 10 ms for a ITER-size reactor. This is a small perturbation (~ 0.1%) to the expected plasma stored energy compared to the previously analyzed case of 20 MJ heat pulse. Even with this relatively modest heat pulse, the LL surface undergoes ~ 100 °C temperature rise. However, the resulting LL surface heating without rapid cooldown mechanism could lead to excessive LL evaporation continuing well after the transient heat flux resulting in a significant Li injection of ~ 0.6 mol in about a 200 ms period. This amount of Li injection could cause plasma dilution and performance degradation. On the other hand, an active Li injection capability if optimized could prevent the LL surface temperature rise and thus reducing subsequent Li evaporation into the plasma by a factor of 7 compared to the passive LL PFC case. A crucial tool of active Li injection is a rapid response pellet injector which could inject light impurity pellets before the excessive heat flux could reach the divertor plate causing serious damage. A simple pellet ablation model suggests a favorable pellet deposition profile for smaller ~ 0.1 mm radius pellet with ~ 10–20 m/s velocity. Moreover, if it is possible to inject from the private flux region, the pellet injection efficiency into the high heat flux strike point region can be as high as 80% compared to ~ 50% for the injection from outer radius region. The pellet deposition efficiency can be further improved by designing a shell-pellet which can burst when a certain ablation fraction is reached. Finally, a possible implementation technique using an inductive pellet injector with a rapid time response of a few msec is proposed here which can be tested in NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review on Low-Temperature Electrolytes for Lithium-Ion and Lithium Metal Batteries

Abstract Among various rechargeable batteries, the lithium-ion battery (LIB) stands out due to its high energy density, long cycling life, in addition to other outstanding properties. However, the capacity of LIB drops dramatically at low temperatures (LTs) below 0 °C, thus restricting its applications as a reliable power source for electric vehicles in cold climates and equipment used in the aerospace. The electrolyte engineering has proved to be one of the most effective approaches to mitigate LIB performance degradation at LTs. In this review, we summarize the important factors contributing to the deterioration in Li + transport and capacity utilization at LTs while systematically categorize the solvents, salts and additives reported in the literature. Strategies to improve the Li + transport kinetics, in the bulk electrolyte and across the interphases, are discussed. In particular, the formation mechanism of solid electrolyte interphase and its functionality for LT electrolytes are analyzed. Perspectives on the future evolution of this area are also provided. Graphical abstract

25 ENERGY STORAGE↗

Using discrete Bayesian networks for diagnosing and isolating cross-level faults in HVAC systems

Fault detection and diagnosis (FDD) technologies are critical to ensure satisfactory building performance, such as reducing energy wastes and negative impacts on occupant comfort and productivity. Existing FDD technologies mainly focus on component-level FDD solutions, which could lead to mis-diagnosis of cross-level faults in heating, ventilating, and air-conditioning (HVAC) systems. Cross-level faults are those faults that occur in one component or subsystem, but cause operational abnormalities in other components or subsystems, and result in a building level performance degradation. How to effectively diagnose the root cause of a cross-level fault is the focus of this study. Here, this paper presents a novel discrete Bayesian Network (DisBN)-based method for diagnosing cross-level faults in an HVAC system commonly used in commercial buildings. A two-level DisBN structure model is developed in this study. The parameters used in the DisBN model are obtained either from expert knowledge or through machine-learning strategies from normal system operation data. Meanwhile, the probability parameters are discretized to incorporate the uncertainties associated with typical expert knowledge. Thus, the developed DisBN method addresses the challenges many other BN based FDD methods face, i.e., the lack of fault data for BN parameter training. The developed DisBN represents causal relationships between a fault and its cross-level system impacts (i.e., fault symptoms or fault indicators) by considering how fault impacts propagate across different levels in an HVAC system. A weather and schedule information-based Pattern Matching (WPM) method is employed to automatically create WPM baseline data sets for each incoming real time snapshot data from the building systems. Consequently, BN inference and real-time diagnostics are achieved by comparing incoming snapshot data and the WPM baseline data set. The proposed method is evaluated using experimental fault data collected in a campus building. Fault diagnosis results demonstrate that the WPM-DisBN method is effective at locating the root causes of cross-level faults in an HVAC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗

CH 4 combustion over a commercial Pd/CeO 2 -ZrO 2 three-way catalyst: Impact of thermal aging and sulfur exposure

Thermal aging and sulfur poisoning are major problems influencing the efficiency and lifetime of natural gas three-way catalysts (TWCs) during real-world operation. In the present study, thermal aging and sulfur-induced deactivations on CH 4 combustion were investigated over commercial monolithic honeycombs, i.e., Pd/CexZr 1-x O 2 (CZ)-based TWCs that are thermally aged in the bench (HTA), followed by being operated behind the stoichiometric natural gas engine in high sulfur fuel (HTA + S). In this work, both HTA and HTA + S samples show degraded performance in CH 4 combustion relative to the fresh one, which are caused by the reconstruction of Pd species induced by thermal aging and the decreased reducibility of the support. The 18 O 2 labelling experiments show that in all cases CH 4 combustion proceeds via a MvK mechanism in which lattice O (OL) plays a key role. The sulfation aging (HTA + S sample) promotes the activation of CH 4 and O 2 by forming Pd δ+ -(SO$_4^{2-}$) δ- and Ce 3+ -VO couples at the interface as compared to HTA sample. However, such a promotion effect could be compromised by the blocking effect of sulfate on the exchange of O L from the bulk to the surface and across the surface. The fundamental understanding of thermal and S deactivation mechanisms from this study could help to predict a real-world lifetime use curve of natural gas TWCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing the dark-state bistability and thermal stability of zinc dynamic windows with nitrile electrolytes

Reversible metal electrodeposition (RME) for dynamic windows is a promising alternative to traditional electrochromics. We explore the reasons behind the bistability of practical RME dynamic windows under a wide temperature range, i.e., how well they maintain their dark state without external power. While Zn dynamic windows with dimethyl sulfoxide electrolytes exhibit adequate bistability at room temperature, their performance degrades at elevated temperatures due to the presence of small amounts of water. Here, to overcome this problem, we developed a set of Zn nitrile electrolytes. The integrated devices can maintain dark-state bistability over at least 1 month at 85°C with 0.1% transmission using a propionitrile (PrCN) electrolyte. Additionally, the PrCN-based Zn dynamic windows possess high optical contrast, color-neutral switching, and promising cyclability, making Zn RME in nitrile electrolytes a promising solution for achieving robust dynamic windows.

RME↗

Investigating the durability of a direct methanol fuel cell equipped with commercial Platinum Group Metal-free cathodic electro-catalysts

For the first time a long-term (500 h) durability study in direct methanol fuel cells (DMFCs) is carried out on a Platinum Group Metal-free (PGM-free) cathodic electro-catalyst commercially available on market. The electro-catalyst is tested for 500 h at a fixed cell voltage (0.3 V), recording the polarization curves during the operation. A drastic decrease in performance is observed after the first 100 h (from 220 to 75 mA cm –2 ); afterwards, the decrease is flatter, passing from 75 to 25 mA cm –2 (at 500 h). The causes of this performance degradation are investigated by postmortem physicochemical analyzes, such as X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) with X-ray energy dispersive analysis (EDX). Finally, possible reasons of degradation are indicated to be PGM-free catalyst aggregation, carbon and nitrogen species decrease, Ruthenium dissolution and migration from the anode to the cathode, poisoning both membrane and cathode catalyst.

25 ENERGY STORAGE↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning assisted bayesian inference of mix and hot-spot conditions in NIF implosions

Experiments on the National Ignition Facility (NIF) have provided clear evidence of ablator material mixing into the Hot-Spot, leading to degraded performance. However, inferring the amount of mix and Hot-Spot conditions from typical experimental observations (e.g. x-ray spectra and images) is highly challenging. Here, we have developed an analysis method that utilizes machine learning assisted Bayesian inference to find the probability distributions of the Hot-Spot and mix conditions. This approach uses a neural network, trained on an idealized 2-dimensional representation of the Hot-Spot and mix distribution, and Bayesian inference to find the statistical distributions of Hot-Spot conditions that provide a match with observations. We have tested this method with synthetic data from simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-objective optimization of low-GWP mixture composition and heat exchanger circuitry configuration for improved system performance and reduced refrigerant flammability

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acceleration of Pd-V intermetallic diffusion by hydrogen

Vanadium-based membranes have great potential for hydrogen purification due to their perfect selectivity, high permeability, and relatively low cost. With appropriate surface cleaning, V efficiently permeates hydrogen at elevated temperature, but performance declines due to its affinity to absorb impurities. Here, the application of palladium thin films maintains a clean surface that catalyzes hydrogen dissociation and recombination. Hydrogen permeation in Pd-V-Pd membranes initially reach theoretical permeability, but declines due to Pd-V interdiffusion. The objective of this work was to quantify the intermetallic diffusion process as a function of temperature and ambient. Pd-V composites were subjected to various annealing treatments and characterized using Auger electron spectroscopy, X-ray diffraction, and energy dispersive X-ray spectroscopy, as well as correlated to measurements of membrane permeability. In an inert environment Pd-V interdiffusion was observable as low as 300 °C, and the diffusion coefficient had an activation energy of 44 kJ/mol. Furthermore, the presence of hydrogen at partial pressures > 10 kPa accelerated interdiffusion six-fold at T = 400 °C. Membrane performance degraded with an activation energy 75 kJ/mol, suggesting that intermetallic diffusion leads to both a loss of catalytic activity and as well as degradation of bulk permeability. These findings provide a baseline for evaluating hydrogen permeable interdiffusion barriers to overcome these challenges.

08 HYDROGEN↗

GaAs solar cells grown on intentionally contaminated GaAs substrates

III-V materials such as GaAs and GaInP have some of the best electronic and optical properties of any semiconductor materials, but deposition of these materials relies on high-quality single crystal GaAs substrates for their superior performance. Unfortunately, the cost of these substrates makes these high-efficiency devices only accessible in high-value or niche markets. In this study, we explore the effect of growing bulk GaAs crystals with lower purity input materials in order to reduce their cost. We observe that intentional impurities added to the melt before the crystal growth occurs segregate to the top of the boule. Single junction GaAs solar cells grown on substrates made from contaminated boules showed no performance degradation compared to a high-purity control substrate. These results suggest that lower purity Ga and As source materials can be used during crystal growth to reduce the cost of substrates.

36 MATERIALS SCIENCE↗

Understanding failure in austenitic steels: Key considerations for molten salt storage in CSP applications

Owing to their excellent properties, austenitic stainless steels are extensively used in boilers, furnaces, molten salt tanks, and other applications that are subjected to extreme mechanical loads and high-temperature conditions. Their high corrosion and creep resistance make them suitable for high-temperature operating environments. Additionally, good fatigue resistance and favorable mechanical and visual properties are essential. However, the premature failure of several components at elevated temperatures has been previously reported. Although the failure analysis of components in service is complex, processes such as cold work and welding have been identified as contributing factors to the performance degradation of these steels. This study aims to analyze the various documented failure modes and mechanisms in austenitic steels, including creep, cracking, stress relaxation cracking, and fatigue, to better understand the multi-objective design requirements for these alloys as structural materials for high-temperature molten salt tanks in Concentrating Solar Power (CSP) plants. Stabilized austenitic grades, such as AISI 347H, demonstrate superior resistance to creep and corrosion-related degradation when compared to non-stabilized grades like AISI 316L at temperatures relevant to concentrated solar power (CSP) applications. In contrast, nickel-based alloys offer enhanced corrosion resistance, albeit at a higher cost. This review underscores that creep, stress relaxation cracking, and thermo-mechanical fatigue are the predominant long-term failure risks in CSP hot tanks.

14 SOLAR ENERGY↗

Inhomogeneous distribution of lithium and electrolyte in aged Li-ion cylindrical cells

Carbonate-based electrolytes in Li-ion batteries exhibit long range order in a frozen state, which enables their non-destructive analysis by diffraction methods. In the current study the spatial distribution of lithium and electrolyte inside the graphite anode was determined in cycled Li-ion cells using monochromatic spatially-resolved neutron diffraction measurements at 150 K. The results indicate a loss of lithium and electrolyte and their non-uniform distribution in the graphite anode in aged Li-ion cells. The observed lithium and electrolyte losses are directly correlated with two electrochemical performance degradation mechanisms, which are responsible for the cell capacity fade.

18650-type↗

Modulating electrode utilization in lithium-ion cells with silicon-bearing anodes

The stability of silicon-containing anodes can, in principle, be extended by constraining these electrodes to limited states of lithiation. Partial utilization of the anode lessens the volume changes experienced by silicon particles during cycling, which can mitigate mechanisms of performance degradation. In full-cells, anode utilization can be modulated by adjusting the relative capacities of the negative and positive electrodes - the N/P ratio. Here, we examine how the N/P ratio affects the long-term stability of Si-based full-cells, and investigate how this parameter would impact the cost and energy of realistic Li-ion cells. Here, we show that, for some configurations, cell failure due to rapid anode degradation can only by avoided at higher N/P ratios. The price of this enhanced stability is accelerated impedance rise at the cathode. Surprisingly, when electrode expansion is taken into account, increasing N/P ratio can actually increase the specific energy and energy density of silicon-rich Li-ion cells.

25 ENERGY STORAGE↗

Computational modeling of coupled mechanical damage and electrochemistry in ternary oxide composite electrodes

Performance degradation of ternary layered oxide cathodes largely originates from their loss of structural integrity in cyclic usage. Mechanical damage, such as intergranular fracture of the active particles, is not only a mechanical cleavage process but also interferes with electrochemical kinetics such as infiltration of liquid electrolyte, surface corrosion of the constituent primary particles, and may eventually isolate the primary grains from the electron conducting network. Here, in this work, we develop a computational framework that integrates electrochemistry of a LiNi x Mn y Co 1−x−y O 2 (NMC) composite cathode with mechanical damage of the active particles. To fully examine the intricate chemomechanical behavior of the electrode, we evaluate the effects of the anisotropic material properties, the influence of mechanical potential on Li transport, and the concurrent intergranular fracture and electrolyte penetration along the grain boundaries upon multiple cycles. Electrolyte infiltration benefits capacity retention but aggravates further mechanical damage by corrosion. Structural failure mostly occurs in the first charging due to the anisotropic mechanical strain between the primary grains, while the resulting damage remains stable in the later few cycles. The results are consistent with experimental observations and the integration of electrochemistry and mechanical failure enables a step further understanding of the complex mechanism of battery degradation.

Battery degradation↗

Robust dynamic operation of high temperature electrolysis solid oxide cells

Here, this study evaluates the durability of Ni/YSZ-supported SOECs under dynamic operating conditions relevant to real-world applications. Systematic tests were conducted to assess cell performance under steam cycling (3 to 75% humidified H 2 ), mode cycling between SOFC and SOEC operation, thermal cycling (150 to 750 °C at OCV, and 600 to 800 °C at 1.3V), and redox cycling (between 50% humidified H 2 and 50% humidified N 2 ). Steam cycling, mode cycling, and thermal cycling at OCV do not significantly accelerate performance degradation. Thermal cycling at 1.3V caused minimal damage within 600 to 800 °C. Full redox cycling (multi-hour oxidation holds) induced cell structural failure, while partial redox cycling (0.5 h holds) was tolerated. Extensive characterization revealed some material evolution, namely Sr and Co secondary phase formation, within the oxygen electrode due to La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ instability, especially for steam cycling and mode cycling. Minimal changes were identified within the Ni-YSZ fuel electrodes. These findings provide critical insights into SOEC reliability under dynamic conditions, supporting their application in dynamic or intermittent energy systems.

08 HYDROGEN↗