Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Characterization of Disruption Halo Currents in the National Spherical Torus Experiment

This paper describes the general characteristics of disruptions halo currents in the National Spherical Torus Experiment [M. Ono, et al. Nuclear Fusion 40, 557 (2000)]. The commonly observed types of vertical motion and resulting halo current patterns are described, and it is shown that plasma discharges developing between components can facilitate halo current flow. The halo current fractions and toroidal peaking factors at various locations in the device are presented. The maximum product of these two metrics for localized halo current measurements is always significantly less than the worst-case expectations from conventional aspect ratio tokamaks (which are typically written in terms of the total halo current). The halo current fraction and impulse is often largest in cases with the fastest plasma current quenches and highest quench rates. The effective duration of the halo current pulse is comparable to or shorter than the plasma current quench time. The largest halo currents have tended to occur in lower β and lower elongation plasmas. The sign of the poloidal halo current is reversed when the toroidal field direction is reversed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

IBEX OBSERVATIONS OF SECONDARY INTERSTELLAR HELIUM AND OXYGEN DISTRIBUTIONS

In this study, we investigate the directional distributions of the secondary interstellar neutral (ISN) He and O populations at Earth's orbit. The secondary populations are created by charge exchange between ISN atoms and interstellar ions in the outer heliosheath. Using the IBEX -Lo He and O observations during the winter–spring seasons (early December to early June) in 2009–2011, we produced all-sky maps for He and O atoms with sputtering corrections. These sky maps include the directional distributions of the primary ISN gas and secondary populations. Our investigations reveal that the secondary He and O populations are observed in the ecliptic longitude range 160°–210°. The peak longitudes of the secondary He and O appear to be 14°–34° and 38°–43° away from the peak longitude of the primary interstellar gas flow, respectively. These results indicate that the secondary populations have lower bulk speeds relative to the Sun and their flow directions deviate from the primary gas flow. These results may indicate that one side of the outer heliosheath is thicker than the other side relative to the flow direction of the primary interstellar gas flow.

79 ASTRONOMY AND ASTROPHYSICS↗

Vacuum ultraviolet radiation/atomic oxygen synergism in fluorinated ethylene propylene Teflon erosion

A micrographic investigation is reported of samples of the fluorinated ethylene propylene (FEP) Teflon thermal-blanketing materials recovered from the Long-Duration Exposure Facility (LDEF) satellite. The samples are taken from the trailing edge and row 8 which correspond to exposures to vacuum UV (VUV) and VUV + atomic O, respectively. Data are taken from SEM and IR-spectra observations, and the LDEF leading-edge FEP shows a high degree of erosion, roughening, and sharp peaks angled in the direction of the flow of atomic O. The trailing edge sample influenced primarily by VUV shows a hard brittle layer and some cracked mosaic patterns. Comparisons to a reference sample suggest that the brittle layer is related to exposure to VUV and is removed by atomic-O impingement. Polymers that are stable to VUV radiation appear to be more stable in terms of atomic oxygen.

Stiegman, A. E.↗

Short-bearing approximation for full journal bearings

A short-bearing approximation of pressure distribution in the oil film is presented which is an extension of the pressure-distribution function of Michell and Cardullo and includes end-leakage effects. Equations giving applied load, attitude angle, location and magnitude of peak film pressure, friction, and required oil flow rate as functions of the eccentricity ratio are also given. The capacity number, a basic non dimensional quantity resulting from this analysis is the product of the Sommerfeld number and the square of the length-diameter ratio. Curves determined by this analysis are compared with previously published experimental data and theoretical curves of Sommerfeld and Cameron and Wood. Conclusions reached indicate that this approximation is of practical value for analysis of short bearings.

FRICTION AND LUBRICATION - HYDRODYNAMIC THEORY↗

Charge-induced secondary atomization in diffusion flames of electrostatic sprays

The combustion of electrostatic sprays of heptane in laminar counterflow diffusion flames was experimentally studied by measuring droplet size and velocity distributions, as well as the gas-phase temperature. A detailed examination of the evolution of droplet size distribution as droplets approach the flame shows that, if substantial evaporation occurs before droplets interact with the flame, an initially monodisperse size distribution becomes bimodal. A secondary sharp peak in the size histogram develops in correspondence of diameters about one order of magnitude smaller than the mean. No evaporation mechanism can account for the development of such bimodality, that can be explained only in terms of a disintegration of droplets into finer fragments of size much smaller than that of the parent. Other evidence in support of this interpretation is offered by the measurements of droplet size-velocity correlation and velocity component distributions, showing that, as a consequence of the ejection process, the droplets responsible for the secondary peak have velocities uncorrelated with the mean flow. The fission is induced by the electric charge. When a droplet evaporates, in fact, the electric charge density on the droplet surface increases while the droplet shrinks, until the so-called Rayleigh limit is reached at which point the repulsion of electric charges overcomes the surface tension cohesive force, ultimately leading to a disintegraton into finer fragments. We report on the first observation of such fissions in combustion environments. If, on the other hand, insufficient evaporation has occurred before droplets enter the high temperature region, there appears to be no significant evidence of bimodality in their size distribution. In this case, in fact, the concentration of flame chemi-ions or, in the case of positively charged droplets, electrons may be sufficient for them to neutralize the charge on the droplets and to prevent disruption.

Gomez, Alessandro↗

The NO Vibrational Fundamental Band: O2-Broadening Coefficients

Rovibrational spectra of the vibrational fundamental of nitric oxide at 1875 cm-1 have been recorded under O2-broadening conditions at 296 K and 0.0056 cm-1 resolution using the Solar Nemeth FTS at the Kitt Peak National Observatory. The use of a flow system, which maintains the NO2 at trace levels, has enabled the first measurement of these broadening coefficients. The broadening of the trace contaminant, N2O, allowed checks of the measured pressures. The least-squares analysis of the spectra includes the nuclear hyperfine structure in addition to (lambda) doubling. We observed differential broadening between the e and f (lambda) components of 2II 1/2 transitions as well as larger differences in broadening observed between 2II3/2 transitions.

Freedman, R. S.↗

On Heatshield Shapes for Mars Entry Capsules

The 70deg sphere-cone - the standard geometry for all US Mars entry missions - is thoroughly examined via flow field simulations at a select few peak heating points along candidate flight trajectories. Emphasis is placed on turbulent heating based on the Baldwin- Lomax turbulence model. It is shown that increased leeward turbulent heating for a 70 sphere-cone flying at angle of attack is primarily due to the discontinuity in curvature between the spherical nose cap and the conical frustum - the attachment of the sonic line at this sphere-cone junction leads to a supersonic edge Mach number over the leeward acreage. In an attempt to mitigate this problem of elevated turbulent heating, alternate geometries, without any curvature discontinuities in the acreage, are developed. Two approaches, one based on nonlinear optimization with constraints, and one based on the use of non-uniform rational B-splines, are considered. All configurations examined remain axisymmetric. The aerothermal performance of alternate geometries is shown to be superior to that of the 70 sphere-cone.

Prabhu, DInesh K.↗

Multiphysics Modeling of an Annular Linear Induction Pump With Applications to Space Nuclear Power Systems

An annular linear induction pump (ALIP) that could be used for circulating liquid-metal coolant in a fission surface power reactor system is modeled in the present work using the computational COMSOL Multiphysics package. The pump is modeled using a two-dimensional, axisymmetric geometry and solved under conditions similar to those used during experimental pump testing. Real, nonlinear, temperature-dependent material properties can be incorporated into the model for both the electrically-conducting working fluid in the pump (NaK-78) and structural components of the pump. The intricate three-phase coil configuration of the pump is implemented in the model to produce an axially-traveling magnetic wave that is qualitatively similar to the measured magnetic wave. The model qualitatively captures the expected feature of a peak in efficiency as a function of flow rate.

Kilbane, J.↗

Characterization of Specimens Exposed in a Li Loop

A monometallic V-4Cr-4Ti thermal convection loop was run for 2,350 h with a peak temperature of 700 C and Li flow rate of 2-3 cm/s. Specimens of V-4Cr-4Ti exposed in the hot and cold leg were tensile tested in vacuum at 500 C showing an increase in the 0.2% yield and ultimate tensile strengths and a decrease in the serration amplitude with decreasing exposure temperature in the loop. However, only minor changes in ductility were measured. With the higher temperature exposures, there was a decrease in Vickers hardness measured but little change in the grain size. Characterization of the microstructure after exposure at 627 C in the loop showed an increase in the density of Ti- and N-rich grain boundary and matrix precipitates near the specimen surface after exposure corresponding to an increase in the hardness in the near-surface region. Two-layer V/Y2O3 coatings on V-4Cr-4Ti substrates also were exposed in the loop and initial room temperature characterization has been conducted.

Unocic, Kinga A↗

Structural characteristics and hydration kinetics of modified steel slag

This study investigates the structural characteristics and hydration kinetics of modified basic oxygen furnace steel slag. The basic oxygen furnace steel slag (BOFS) was mixed with electric arc furnace steel slag (EAFS) in appropriate ratios and heated again at high temperature in the laboratory. The mineralogical and structural characteristics of both BOFS and modified steel slag (MSS) were characterized by X-ray diffraction, optical microscopy, scanning electron microscopy, Raman and Fourier transform infrared spectroscopies. The results show that modification increases alite content in MSS and decreases alite crystal size with the formation of C{sub 6}AF{sub 2}. One more obvious heat evolution peak appears in MSS's heat-flow rate curves in comparison to BOFS, becoming similar to that of typical Portland cement paste. As a result, its cementitious activity is much improved.

36 MATERIALS SCIENCE↗

THE HYDROLYSIS AND OXIDATION BEHAVIOR OF LITHIUM BOROHYDRIDE AND MAGNESIUM HYDRIDE DETERMINED BY CALORIMETRY

Lithium borohydride, magnesium hydride and the 2:1 'destabilized' ball milled mixtures (2LiBH{sub 4}:MgH{sub 2}) underwent liquid phase hydrolysis, gas phase hydrolysis and air oxidation reactions monitored by isothermal calorimetry. The experimentally determined heats of reaction and resulting products were compared with those theoretically predicted using thermodynamic databases. Results showed a discrepancy between the predicted and observed hydrolysis and oxidation products due to both kinetic limitations and to the significant amorphous character of observed reaction products. Gas phase and liquid phase hydrolysis were the dominant reactions in 2LiBH{sub 4}:MgH{sub 2} with approximately the same total energy release and reaction products; liquid phase hydrolysis displayed the maximum heat flow for likely environmental exposure with a peak energy release of 6 (mW/mg).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Peak-Seeking Optimization of Trim for Reduced Fuel Consumption: Architecture and Performance Predictions

A peak-seeking control approach for real-time trim configuration optimization for reduced fuel consumption has been developed by researchers at the National Aeronautics and Space Administration (NASA) Dryden Flight Research Center to address the goals of the NASA Environmentally Responsible Aviation project to reduce fuel burn and emissions. The peak-seeking control approach is based on a steepest-descent algorithm using a time-varying Kalman filter to estimate the gradient of a performance function of fuel flow versus control surface positions. In real-time operation, deflections of symmetric ailerons, trailing-edge flaps, and leading-edge flaps of an F/A-18 airplane (McDonnell Douglas, now The Boeing Company, Chicago, Illinois) are controlled for optimization of fuel flow. This paper presents the design and integration of this peak-seeking controller on a modified NASA F/A-18 airplane with research flight control computers. A research flight was performed to collect data to build a realistic model of the performance function and characterize measurement noise. This model was then implemented into a nonlinear six-degree-of-freedom F/A-18 simulation along with the peak-seeking control algorithm. With the goal of eventual flight tests, the algorithm was first evaluated in the improved simulation environment. Results from the simulation predict good convergence on minimum fuel flow with a 2.5-percent reduction in fuel flow relative to the baseline trim of the aircraft.

performance optimization↗

Splitting supersonic nozzle flow into separate jets by overexpansion into a multilobed divergent nozzle

Air flowing from a convergent nozzle at pressure ratios greater than 2.5 has been split into eight separate jets by overexpansion of the flow into a divergent, eight-lobed passage. The splitting of the flow is accompanied by a decrease in the nozzle axial centerline Mach number. This in part is due to the radial inflow of secondary air between the lobes toward the nozzle centerline. Each of the smaller jets is partially split after it leaves the end of the divergent lobed section of the nozzle, thus creating a velocity profile having 16 peaks. At a pressure ratio of 3.5 the flow decelerates to Mach 1 in three convergent nozzle throat diameters. Convergent nozzle flow normally requires 12 diameters to reach Mach 1. The nozzle has a sound attenuation of 12 decibels with a thrust loss of 9 percent for the best configuration tested.

Huff, R. G.↗

Aerodynamic performance of axial-flow fan stage operated at nine inlet guide vane angles

The overall performance of a fan stage with nine inlet guide vane angle settings is presented. These data were obtained over the stable flow range at speeds from 60 to 120 percent of design for vane setting angles from -25 to 42.5 degrees. At design speed and design inlet guide vane angle, the stage has a peak efficiency of 0.892 at a pressure ratio of 1.322 and a flow of 25.31 kg/s. The stall margin based on peak efficiency and stall was 20 percent. Based on an operating line passing through the peak efficiency point at the design setting angle, the useful operating range of the stage at design speed is limited by stall at the positive setting angles and by choke at the negative angles. At design the calculated static thrust along the operating line varied from 68 to 114 percent of that obtained at design setting angle.

Moore, R. D.↗

Energetic Potential for Demand Response in Detached Single Family Homes in Austin, TX

This study builds a generalized tool to quantify the maximum peak load reduction achievable with residential demand response and distributed energy resources (DERs). The tool is demonstrated by using empirical energy usage data from detached single family households within the service territory of Austin Energy - the local municipal utility in Austin, TX. The demand response optimization algorithm shifts energy usage of four controllable, high-consumption residential devices to off-peak hours: HVAC (heating, ventilation, and air conditioning) systems, electric water heaters, electric vehicles, and pool pumps. In addition, rooftop solar generation on individual residences is considered to reduce net load to the utility, and an energy storage system optimization model performing energy arbitrage further reduces peak demand. Results from the aggregate demand response and battery optimization study indicate that peak demand for the 2017 summer peak in Austin Energy could have been reduced by 26 MW or 2.9%. Here, by considering the combined effect of controllable consumer loads, solar generation, and energy storage systems, this study highlights the potential of strategic demand response and energy arbitrage to reduce peak demand at the distribution level.

14 SOLAR ENERGY↗

High Performance Hydrogen/Bromine Redox Flow Battery for Grid-Scale Energy Storage

The electrochemical behavior of a promising hydrogen/bromine redox flow battery is investigated for grid-scale energy-storage application with some of the best redox-flow-battery performance results to date, including a peak power of 1.4 W/cm(2) and a 91% voltaic efficiency at 0.4 W/cm(2) constant-power operation. The kinetics of bromine on various materials is discussed, with both rotating-disk-electrode and cell studies demonstrating that a carbon porous electrode for the bromine reaction can conduct platinum-comparable performance as long as sufficient surface area is realized. The effect of flow-cell designs and operating temperature is examined, and ohmic and mass-transfer losses are decreased by utilizing a flow-through electrode design and increasing cell temperature. Charge/discharge and discharge-rate tests also reveal that this system has highly reversible behavior and good rate capability. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.018211jes] All rights reserved.

Cho, KT↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Characteristics of Axial Power Shape and Flow Field at Low Flow Condition

The representative event which experiences the low flow condition is SLB (Steam Line Break) event. During the SLB event with LOOP (Loss of Offsite Power), the reactor core is tripped and all RCPs (Reactor Coolant Pump) are stopped. The biggest worth control rod also stuck out. As a result, the flow rate and pressure in reactor core decrease and the peaking factor is relatively high compared to a nominal operating condition. In this paper, we study the tendency of the core axial power distribution and flow field with respect to the core average power at the SLB accident condition. Generally, the condition has been analyzed using the neutronics code with one dimensional flow result of the assemblies. However, if the core average power increases, the coolant density in the hot channel decreases and mass flux increases. The assumption that the mass flux is constant at the one dimensional analysis is incorrect. Hence, it is needed to couple the neutronics code and the subchannel analysis code in order to give feedback to neutronics code with the 3-D flow information. In this study, we coupled the nuclear design code and the subchannel analysis code and showed the characteristics of the axial power distribution and the flow field at the low flow condition. Since there is no experimental data at the condition, the characteristics of the power distribution and flow field were analyzed to understand the physical phenomena. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗