Preparation and analysis of particulate metal deposits

Small particles and clusters of palladium were grown by deposition from the vapor phase under ultrahigh vacuum conditions. Amorphous and crystalline support films of Al2O3 and ultrathin amorphous carbon films were used as substrate materials. The growth of the metal deposit was monitored in situ by scanning transmission diffraction of energy-filtered 100 kV electrons and high resolution transmission electron microscopy (TEM) analysis was performed in a separate instrument. It was established by in situ TEM, however, that the transfer of specimens in this case did not unduly affect the size and distribution of deposit particles. It was found that the cleanness, stoichiometry, crystallinity and structural perfection of the support surface play an essential role in determining the crystalline perfection and structure of the particles. The smallest palladium clusters reproducibly prepared contained not more than six atoms but size determinations below 1 nm average particle diameter are very problematic with conventional TEM. Palladium particles grown on carbon supports feature an impurity-stabilized mosaic structure.

Poppa, H.↗

Interpretation of satellite-measured bidirectional reflectance from Cirrus cloudy atmospheres

The interpretation of the observed bidirectional reflectance from cirrus cloudy atmospheres is presented. A theoretical model was developed for the computation of the transfer of solar radiation in an anisotropic medium with particular applications to oriented ice crystals in cirrus clouds. In this model, the adding principle for radiative transfer was used with modifications to account for the anisotropy of scattering particles and the associated scattering phase matrix. The single-scattering properties, including the phase function, single-scattering albedo, and extinction cross sections, were used for randomly and horizontally oriented hexagonal ice crystals in radiative transfer computations. The radiative transfer model developed for the cirrus clouds was modified to account for the scattering contributions from the atmosphere and the surface. In order to test the relevance and significance of the ice crystal model for the interpretation of observed bidirectional reflectance from satellites, visible radiances collected on the half hour by the GOES series were selected. The data are calibrated and corrected with the proper filter functions, then navigated to match selected landmark data. A number of clear and cloudy cases during the cirrus IFO of the Fire experiment were chosen for theoretical analyses. The cloud particle shape and size distributions that were taken during satellite overpasses are used in radiative transfer calculations. The sensitivities of the shape, orientation, and size distribution of ice crystals on the reflected intensities at the top of the atmosphere are investigated. Finally, the relative importance of these cloud microphysical properties in the interpretation of satellite bidirectional reflectance are assessed and presented.

Takano, Y.↗

The ATLAS Fast TracKer system

The ATLAS Fast TracKer (FTK) was designed to provide full tracking for the ATLAS high-level trigger by using pattern recognition based on Associative Memory (AM) chips and fitting in high-speed field programmable gate arrays. The tracks found by the FTK are based on inputs from all modules of the pixel and silicon microstrip trackers. The as-built FTK system and components are described, as is the online software used to control them while running in the ATLAS data acquisition system. Also described is the simulation of the FTK hardware and the optimization of the AM pattern banks. An optimization for long-lived particles with large impact parameter values is included. A test of the FTK system with the data playback facility that allowed the FTK to be commissioned during the shutdown between Run 2 and Run 3 of the LHC is reported. The resulting tracks from part of the FTK system covering a limited $\eta$-$\phi$ region of the detector are compared with the output from the FTK simulation. It is shown that FTK performance is in good agreement with the simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Filtration of Hanford Tank 241-AN-107 Supernatant at 16 °C

Approximately 9 liters of supernatant from Hanford waste tank 241-AN-107 was delivered by Washington River Protection Solutions to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory. The thirty-six AN-107 sample bottles consisted of six sets of six samples, with each set pulled from a unique tank sampling level. Prior to testing, samples from each level were composited to provide nominally level-independent feed for dead end filtration and ion exchange testing. The composited 241-AN-107 supernatant was chilled to 16 °C for 1 week prior to testing. Filtration testing was then conducted using a backpulse dead-end filter (BDEF) system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the RPL. The purpose of this testing is to a) demonstrate dead-end filtration (DEF) of AN-107 feed at reduced temperature to obtain prototypic tank side cesium removal (TSCR) flux rates and identify issues that may impact filtration after dilution to 5.5M Na, and b) provide feed for a follow on ion exchange unit operation. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 . During filtration the differential pressure required to effect filtration at 0.065 gpm/ft 2 was slow to increase for most of the filtration campaign. After all the feed bottles had been pumped into the slurry reservoir, the bottoms of the bottles were added to the reservoir and transmembrane pressure (TMP) reached 2.0 psid (the TSCR action limit). The prototypic filter cleaning process was unable to effectively restore filter performance, and cleaning with oxalic acid was required before flow through the filter could be restored. This indicates that the Media Grade 5 filter may require an alternative cleaning protocol when processing AN-107 supernatant. After completing filtration of the AN-107 feed, the filter was cleaned. Solids concentrated from the backpulse solutions were composed of natrophosphate, Mn-Fe phases, and fluoro-natrophosphate that occurred as particle agglomerates. The individual particles were in some cases 100s of micrometers across which is consistent with prior observations from AN-107 supernate waste characterizations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Satellite stratospheric aerosol measurement validation

The validity of the stratospheric aerosol measurements made by the satellite sensors SAM II and SAGE was tested by comparing their results with each other and with results obtained by other techniques (lider, dustsonde, filter, and impactor). The latter type of comparison required the development of special techniques that convert the quantity measured by the correlative sensor (e.g. particle backscatter, number, or mass) to that measured by the satellite sensor (extinction) and quantitatively estimate the uncertainty in the conversion process. The results of both types of comparisons show agreement within the measurement and conversion uncertainties. Moreover, the satellite uncertainty is small compared to aerosol natural variability (caused by seasonal changes, volcanoes, sudden warmings, and vortex structure). It was concluded that the satellite measurements are valid.

Russell, P. B.↗

Satellite stratospheric aerosol measurement validation

The validity of the stratospheric aerosol measurements made by the satellite sensors SAM II and SAGE was tested by comparing their results with each other and with results obtained by other techniques (lider, dustsonde, filter, and impactor). The latter type of comparison required the development of special techniques that convert the quantity measured by the correlative sensor (e.g., particle backscatter, number, or mass) to that measured by the satellite sensor (extinction) and quantitatively estimate the uncertainty in the conversion process. The results of both types of comparisons show agreement within the measurement and conversion uncertainties. Moreover, the satellite uncertainty is small compared to aerosol natural variability (caused by seasonal changes, volcanoes, sudden warmings, and vortex structure). It was concluded that the satellite measurements are valid.

Russell, P. B.↗

Airborne Dust in Space Vehicles and Habitats

Airborne dust, suspended inside a space vehicle or in future celestial habitats, can present a serious threat to crew health if it is not controlled. During the Apollo missions to the moon, lunar dust brought inside the capsule caused eye irritation and breathing difficulty to the crew when they launched from the moon and re-acquired "microgravity." During Shuttle flights reactive and toxic dusts such as lithium hydroxide have created a risk to crew health, and fine particles from combustion events can be especially worrisome. Under nominal spaceflight conditions, airborne dusts and particles tend to be larger than on earth because of the absence of gravity settling. Aboard the ISS, dusts are effectively managed by HEPA filters, although floating dust in newly-arrived modules can be a nuisance. Future missions to the moon and to Mars will present additional challenges because of the possibility that external dust will enter the breathing atmosphere of the habitat and reach the crew's respiratory system. Testing with simulated lunar and Martian dust has shown that these materials are toxic when placed into the lungs of test animals. Defining and evaluating the physical and chemical properties of Martian dusts through robotic missions will challenge our ability to prepare better dust simulants and to determine the risk to crew health from exposure to such dusts.

James, John↗

I Love My Attitude Problem

This viewgraph presentation provides a survey of modern methods for attitude estimation. Two algorithms are discussed: Kalman Filters and Wahba's Problem. Several spacecraft Attitude Determination And Control Subsystem (ADACS) are discussed including: Solar Maximum Mission (SMM), Solar, Anomalous, and Magnetospheric Particle Explorer (SAMPEX), Hubble Space Telescope (HST), Tropical Rainfall Measuring Mission (TRMM), and Wilkinson Microwave Anisotropy Probe (WMAP). Also included is a discussion about Zero Gyro Sunpoint (ZGSP), and the WMAP Attitude Anomaly.

Markley, F. Landis↗

Sky-Scanning Sun-Tracking Airborne Radiometer (3STAR): Instrument Design, Flight Testing, and Tracking Performance

The Sky-Scanning, Sun-Tracking Airborne Radiometer (3STAR) adapts commercial radiometer technology developed for the ocean color research community to airborne measurement of spectrally resolved solar irradiance and sky radiance. These atmospheric observations are used to derive aerosol optical depth (AOD), supporting localized AOD inputs for atmospheric correction of satellite and airborne data over terrestrial and aquatic (including optically dark) targets. The ability to regionally “tune” atmospheric correction schemes with relevant spatial AOD supports constraining atmospheric correction of remote sensing reflectance. Very wide dynamic range has been achieved for multi-channel band-pass-filter-radiometers originally designed for deployment into the water column. By actively tracking and directly pointing to the Sun, the light attenuation by aerosol particles in the atmospheric column can be quantified. These measurements improve knowledge of atmospheric constituents and the atmospheric corrections required to improve remote sensing capabilities for interpreting reflectance measurements from the Earth surface. 3STAR incorporates a custom Sun-tracking/sky-scanning pointing head, a Sun-tracking camera, and a commercially available, cylindrical, 19-channel radiometer tube assembly. An accurate and responsive mount and tracking system has been developed and certified to NASA and Naval Air Systems Command (NAVAIR) airworthiness standards for deployment into the aircraft slipstream. Ground and flight testing indicate typical tracking errors of less than 0.1 degrees, well within the field of view of the radiometer as required to minimize measurement uncertainty from alignment error. Preliminary AOD measurements compare to within 0.013 with 15 measurements from an Aerosol Robotic Network (AERONET) Cimel instrument at 500 nm wavelength and low solar angle.

Atmosphere↗

On obtaining the forward phase functions of Saturn ring features from radio occultation observations

It is noted that the near-forward scattering functions of particles in Saturn ring features are related to 3.6 cm radio occultation power spectra by a Fredholm integral equation of the first kind. The equation reduces to an algebraic system of equation whose solution by usual inversion techniques (that is, least mean squares) is ruled out by the near singularity of the forward transformation matrix. A combination of constrained linear inversion and a filtering algorithm based on eigenvector decomposition of the matrix reduces the instabilities; this yields derived phase functions valid over the range of zero to about 12 mrad. It is noted that these functions represent the collective forward diffraction lobe of particles greater than about 1 m in radius. Since multiple scattering of the signal is a significant effect, the measured phase functions must be adjusted to obtain the singly scattered component. This single-scattering correction is examined for two physical models, namely the monolayer and the classical discrete random slab; in addition, the fraction of opacity in submeter particles for each model for particular ring features is estimated.

Zebker, H. A.↗

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Project-2 centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line, a critical system that defines the ideal path for the particle beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40°C. The system utilizes an aluminum 36”x36”x0.5” heat plate powered by a MOSFET-based control circuit, delivering approximately 460 W of thermal energy through a resistor array. Real-time temperature feedback is provided by a PT100 Resistance Temperature Detector (RTD), which interfaces with a Proportional–Integral–Derivative (PID) control algorithm to maintain closed-loop temperature regulation. The control signal actively modulates the gate voltage of an N channel MOSFET, dynamically adjusting power delivery in response to deviations from the temperature setpoint. Simulations and LTspice models validate the functionality and responsiveness of the circuit under varying conditions. The prototype has successfully demonstrated stable thermal control, paving the way for integration into the PIP-II infrastructure. The final design will feature an expanded resistor array, as well as communication with a PLC for continuous data acquisition and diagnostics. This work directly supports Fermilab’s broader mission by contributing to the stability and reliability of core accelerator systems, enhancing the precision of particle beam delivery for future physics experiments.

Mosher, Alexander [Fermilab]↗

Analysis of wear-debris from full-scale bearing fatigue tests using the ferrograph

The ferrograph was used to determine the types and quantities of wear particles generated during full-scale bearing fatigue tests. Deep-groove ball bearings made from AISI 52100 steel were used. A MIL-L-23699 tetraester lubricant was used in a recirculating lubrication system containing a 49 mm absolute filter. Test conditions included a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm, and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the ferrograph was more sensitive (up to 23 hr) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis. Four particle types were observed: normal rubbing wear particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R.↗

Analysis of Mount St. Helens ash from optical photoelectric photometry

The optical properties of suspended dust particles from the eruption of Mt. St. Helens on July 23, 1980 are investigated using photoelectric observations of standard stars obtained on the 0.76-m telescope at the University of Washington 48 hours after the eruption. Measurements were made with five broad-band filters centered at 3910, 5085, 5480, 6330, and 8050 A on stars of varying color and over a wide range of air masses. Anomalous extinction effects due to the volcanic ash were detected, and a significant change in the wavelength-dependent extinction parameter during the course of the observations was established by statistical analysis. Mean particle size (a) and column density (N) are estimated using the Mie theory, assuming a log-normal particle-size distribution: a = 0.18 micron throughout; N = 1.02 x 10 to the 9th/sq cm before 7:00 UT and 2.33 x 10 to the 9th/sq cm after 8:30 UT on July 25, 1980. The extinction is attributed to low-level, slowly migrating ash, possibly combined with products of gas-to-particle conversion and coagulation.

Cardelli, J. A.↗

Analysis of wear debris from full-scale bearing fatigue tests using the Ferrograph

The Ferrograph was used to determine the types of quantities of wear particles generated during full-scale bearing fatigue tests. Deep-groove ball bearings made from AISI 52100 steel were used. A MIL-L-23699 tetraester lubricant was used in a recirculating lubrication system containing a 49-micron absolute filter. Test conditions included a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the Ferrograph was more sensitive (up to 23 h) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis (SOAP). Four particle types were observed: normal rubbing wear particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R., Jr.↗

Enhanced emission of iron nuclei in solar flares

A silica glass window from Apollo 12 CM and a piece of flint glass from the Surveyor 3 camera filter were examined for Fe nuclei tracks. A large difference between observed and predicted track densitites was found. At low rigidity (or energy), the solar particle Fe/He ratio is much higher than the photospheric abundance ratio, but decreases with increasing rigidity until it approaches the photospheric value at a rigidity of about 500 MV. It is felt that the low-energy Fe tracks are of solar origin. The implications that heavy nuclei can be preferentially emitted from a source of energetic particles are discussed. Other conclusions are the following: Rocks exposed on the lunar surface for 10 million yr would accumulate about 6 x 10 to the 12th power tracks/sq cm, and the rate of radiation-induced erosion is about 10 to the -9 cm/yr. The lunar soil should contain heavily irradiated small grains, some with track densities of about 10 to the 12th power/sq cm that have flaked from radiation-damaged rock surfaces and some that were irradiated while at the top of the soil layer.

Price, P. B.↗

Clean Room Apparel

American Hospital Supply Corporation (AHSC), Baxter Healthcare Corporation's predecessor, used the NASA informational base on contamination control technology to improve industrial contamination control technology. When a study determined that microscopic body particles escaping through tiny "windows" in woven garments worn by workers were the greatest source of contamination, AHSC developed TYVEK. This non-woven material filters 99% of all particulate matter larger than half a micron. Baxter Healthcare added a polyimide coating which seals and ties down any loose fibers, providing greater durability. Stress points along seams have been minimized to make the garment almost tearproof. Micro-Clean 212 garments are individually packaged and disposable.

Source record↗

Atmosphere Analyzer

California Measurements, Inc.'s model PC-2 Aerosol Particle Analyzer is produced in both airborne and ground-use versions. Originating from NASA technology, it is a quick and accurate method of detecting minute amounts of mass loadings on a quartz crystal -- offers utility as highly sensitive detector of fine particles suspended in air. When combined with suitable air delivery system, it provides immediate information on the size distribution and mass concentrations of aerosols. William Chiang, obtained a NASA license for multiple crystal oscillator technology, and initially developed a particle analyzer for NASA use with Langley Research Center assistance. Later his company produced the modified PC-2 for commercial applications Brunswick Corporation uses the device for atmospheric research and in studies of smoke particles in Fires. PC-2 is used by pharmaceutical and chemical companies in research on inhalation toxicology and environmental health. Also useful in testing various filters for safety masks and nuclear installations.

Source record↗

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).