Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A Fourier transform spectrometer without a beam splitter for the vacuum ultraviolet range: From the optical design to the first UV spectrum

We describe a Fourier transform (FT) spectrometer designed to operate down to 60 nm (20 eV) on a synchrotron radiation beamline for high resolution absorption spectrometry. As far as we know, such an instrument is not available below 140 nm mainly because manufacturing accurate and efficient beam splitters remains a major problem at these wavelengths, especially if a wide bandwidth operation is desired. In order to overcome this difficulty, we developed an interferometer based on wave front division instead of amplitude division. It relies on a modified Fresnel bimirror configuration that requires only flat mirrors. The instrument provides path difference scanning through the translation of one reflector. During the scanning, the moving reflector is controlled by an optical system that keeps its direction constant within a tolerable value and provides an accurate interferometric measurement of the path difference variation. Therefore, a regular interferogram sampling is obtained, producing a nominal spectral impulse response and an accurate spectral calibration. The first results presented in this paper show a measured spectral resolution of {delta}{sigma}=0.33 cm{sup -1} (interval between spectral samples). This was obtained with a sampling interval of 29 nm (path difference) and 512 K samples from a one-sided interferogram using a cosine FT. Such a sampling interval should allow the recording of large bandwidth spectra down to {lambda}=58 nm with an ultimate resolving power of 500 000 at this wavelength. In order to check the instrument performances, we first recorded an interferogram from a He-Ne stabilized laser. This provided the actual spectral impulse function, which was found to be fully satisfactory. The determination of the impulse response distortion and of the noise on the vacuum ultraviolet (VUV) spectral range provided accurate information in the sampling error profile over a typical scan. Finally, the instrument has been moved to the SU5 undulator-based synchrotron radiation beamline (Super-ACO facility, LURE, Orsay, France). A high resolution spectrum of O{sub 2} (the Schumann-Runge absorption bands, 185-200 nm) was computed from recorded interferograms using the beamline monochromator at the zeroth order to feed the instrument with an 11% relative bandwidth ''white'' beam (2003). These UV measurements are very close to those found in the literature, showing nominal performances of the FT spectrometer that should translate into an unprecedented resolving power at shortest VUV wavelengths. A recent upgrade (2007) and future developments will be discussed in light of the current installation of the upgraded FT spectrometer as a permanent endstation for ultrahigh resolution absorption spectrometry on the VUV beamline DESIRS at SOLEIL, the new French third generation synchrotron facility.

43 PARTICLE ACCELERATORS↗

Solution NMR studies provide structural basis for endotoxin pattern recognition by the innate immune receptor CD14

CD14 functions as a key pattern recognition receptor for a diverse array of Gram-negative and Gram-positive cell-wall components in the host innate immune response by binding to pathogen-associated molecular patterns (PAMPs) at partially overlapping binding site(s). To determine the potential contribution of CD14 residues in this pattern recognition, we have examined using solution NMR spectroscopy, the binding of three different endotoxin ligands, lipopolysaccharide, lipoteichoic acid, and a PGN-derived compound, muramyl dipeptide to a {sup 15}N isotopically labeled 152-residue N-terminal fragment of sCD14 expressed in Pichia pastoris. Mapping of NMR spectral changes upon addition of ligands revealed that the pattern of residues affected by binding of each ligand is partially similar and partially different. This first direct structural observation of the ability of specific residue combinations of CD14 to differentially affect endotoxin binding may help explain the broad specificity of CD14 in ligand recognition and provide a structural basis for pattern recognition. Another interesting finding from the observed spectral changes is that the mode of binding may be dynamically modulated and could provide a mechanism for binding endotoxins with structural diversity through a common binding site.

60 APPLIED LIFE SCIENCES↗

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A TEST OF THICK-TARGET NONUNIFORM IONIZATION AS AN EXPLANATION FOR BREAKS IN SOLAR FLARE HARD X-RAY SPECTRA

Solar nonthermal hard X-ray (HXR) flare spectra often cannot be fitted by a single power law, but rather require a downward break in the photon spectrum. A possible explanation for this spectral break is nonuniform ionization in the emission region. We have developed a computer code to calculate the photon spectrum from electrons with a power-law distribution injected into a thick target in which the ionization decreases linearly from 100% to zero. We use the bremsstrahlung cross section from Haug, which closely approximates the full relativistic Bethe-Heitler cross section, and compare photon spectra computed from this model with those obtained by Kontar et al., who used a step-function ionization model and the Kramers approximation to the cross section. We find that for HXR spectra from a target with nonuniform ionization, the difference (DELTAgamma) between the power-law indexes above and below the break has an upper limit between approx0.2 and 0.7 that depends on the power-law index delta of the injected electron distribution. A broken power-law spectrum with a higher value of DELTAgamma cannot result from nonuniform ionization alone. The model is applied to spectra obtained around the peak times of 20 flares observed by the Ramaty High-Energy Solar Spectroscopic Imager from 2002 to 2004 to determine whether thick-target nonuniform ionization can explain the measured spectral breaks. A Monte Carlo method is used to determine the uncertainties of the best-fit parameters, especially on DELTAgamma. We find that 15 of the 20 flare spectra require a downward spectral break and that at least six of these could not be explained by nonuniform ionization alone because they had values of DELTAgamma with less than a 2.5% probability of being consistent with the computed upper limits from the model. The remaining nine flare spectra, based on this criterion, are consistent with the nonuniform ionization model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dependence of Yb-169 absorbed dose energy correction factors on self-attenuation in source material and photon buildup in water

Purpose: Absorbed dose energy correction factors, used to convert the absorbed dose deposited in a LiF thermoluminescent dosimeter (TLD) into the clinically relevant absorbed dose to water, were obtained for both spherical volumetric sources and for the model 4140 HDR Yb-169 source. These correction factors have a strong energy dependence below 200 keV; therefore, spectral changes were quantified as Yb-169 photons traveled through both source material (Yb{sub 2}O{sub 3}) and water with the corresponding absorbed dose energy correction factors, f(r,{theta}), calculated as a function of location in a phantom. Methods: Using the MCNP5 Monte Carlo radiation transport simulation program, the Yb-169 spectrum emerging from spherical Yb{sub 2}O{sub 3} sources (density 6.9 g/cm{sup 3}) with radii between 0.2 and 0.9 mm were analyzed and their behavior compared against those for a point-source. The absorbed dose deposited to both LiF and H{sub 2}O materials was analyzed at phantom depths of 0.1-10 cm for each source radius and the absorbed dose energy correction factor calculated as the ratio of the absorbed dose to water to that of LiF. Absorbed dose energy correction factors for the Model 4140 Yb-169 HDR brachytherapy source similarly were obtained and compared against those calculated for the Model M-19 Ir-192 HDR source. Results: The Yb-169 average spectral energy, emerging from Yb{sub 2}O{sub 3} spherical sources 0.2-0.9 mm in radius, was observed to harden from 7% to 29%; as these photons traveled through the water phantom, the photon average energy softened by as much as 28% at a depth of 10 cm. Spectral softening was dependent on the measurement depth in the phantom. Energy correction factors were found to vary both as a function of source radius and phantom depth by as much as 10% for spherical Yb{sub 2}O{sub 3} sources. The Model 4140 Yb-169 energy correction factors depended on both phantom depth and reference angle and were found to vary by more than 10% between depths of 1 and 10 cm and angles of 0 deg. and 180 deg. This was in contrast to that of the Model M-19 Ir-192 source which exhibited approximately 3.5%-4.4% variation in its energy correction factors from phantom depths of 0.5-10 cm. The absorbed dose energy correction factor for the Ir-192 source, on the other hand, was independent of angle to within 1%. Conclusions: The application of a single energy correction factor for Yb-169 TLD based dosimetry would introduce a high degree of measurement uncertainty that may not be reasonable for the clinical characterization of a brachytherapy source; rather, an absorbed dose energy correction function will need to be developed for these sources. This correction function should be specific to each source model, type of TLD used, and to the experimental setup to obtain accurate and precise dosimetric measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evidence for multiple modes of uranium immobilization by an anaerobic bacterium

Microbial reduction of hexavalent uranium has been studied widely for its potential role in bioremediation and immobilization of soluble U(VI) in contaminated groundwater. More recently, some microorganisms have been examined for their role in immobilization of U(VI) via precipitation of uranyl phosphate minerals mediated by microbial phosphate release, alleviating the requirement for long-term redox control. Here, we investigated the mechanism of U(VI) removal mediated by an environmental isolate, strain UFO1, that is indigenous to the Field Research Center (FRC) in Oak Ridge, TN and has been detected in U(VI)-contaminated sediments. Changes in U(VI) speciation were examined in the presence and absence of the electron-shuttling moiety, anthraquinone-2,6-disulfonate (AQDS). Cell suspensions were capable of nearly complete removal of 100 μM U(VI) from solution within 48 hours; U(VI) removal was not dependent on the presence of an exogenous electron donor or AQDS, although AQDS increased the rate of U(VI) removal. X-ray Absorption Near Edge Structure (XANES) spectroscopic measurements indicated that U(IV) was the predominant oxidation state of uranium in cell suspensions in both the absence and presence of 100 μM AQDS. However, extended X-ray Absorption Fine Structure spectroscopy (EXAFS) measurements indicated that 17% of the cell-associated precipitates in a U(VI)-treated suspension that lacked AQDS had spectral characteristics consistent with a uranyl phosphate solid phase. The potential involvement of phosphate was consistent with observed increases in soluble phosphate concentrations over time in UFO1 cell suspensions, which suggested phosphate liberation from the cells. TEM-EDS confirmed the presence of uranyl phosphate with a U:P ratio consistent with autunite (1:1). EXAFS analyses further showed that U(IV) was present predominantly as a monomeric complex sorbed to carboxylate functional groups on biomass and also suggested that a fraction of the U(IV) was coordinated to phosphoryl ligands. These results suggest that strain UFO1 has the ability to facilitate U(VI) removal from solution via both reductive and phosphate precipitation mechanisms, and may potentially be useful for the remediation of U-contaminated sediments at the FRC or elsewhere.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spectral and dynamical analysis of a single vortex ring in anisotropic harmonically trapped three-dimensional Bose-Einstein condensates

Here in the present work, motivated by numerous recent experimental developments we revisit the dynamics of a single vortex ring in anisotropic harmonic traps. At the theoretical level, we start from a general Lagrangian dynamically capturing the evolution of a vortex ring and not only consider its spectrum of linearized excitations, but also explore the full nonlinear dynamical evolution of the ring as a vortical filament. The theory predicts that the ring is stable for 1 ≤ λ ≤ 2, where λ = ω z /ω r is the ratio of the trapping frequencies along the z and r axes, i.e., for spherical to slightly oblate condensates. We compare this prediction with direct numerical simulations of the full three-dimensional Gross-Pitaevskii equation (GPE) capturing the linearization spectrum of the ring for different values of the chemical potential and as a function of the anisotropy parameter λ . We identify this result as being only asymptotically valid as the chemical potential μ → ∞, revealing how the stability interval narrows and, in particular, its upper bound decreases for finite μ. Finally, we compare at the dynamical level the results of the GPE with the ones effectively capturing the ring dynamics, revealing the unstable evolution for different values of λ, as well as the good agreement between the two.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mass Spectral Detection of Forward- and Reverse-Hydrogen/Deuterium Exchange Resulting from Residual Solvent Vapors in Electrospray Sources

Characterizing glycans is analytically challenging since glycans are heterogeneous, branched polymers with different three-dimensional conformations. Hydrogen/deuterium exchange-mass spectrometry (HDX-MS) has been used to analyze native conformations and dynamics of biomolecules by measuring the mass increase of analytes as labile protons are replaced with deuterium following exposure to deuterated solvents. The rate of exchange is dependent on the chemical functional group, the presence of hydrogen bonds, pH, temperature, charge, and solvent accessibility. HDX-MS of carbohydrates is challenging due to the rapid exchange rate of hydroxyls. Here, we describe an observed HDX reaction associated with residual solvent vapors saturating electrospray sources. When undeuterated melezitose was infused after infusing D{sub 2}O, samples with up to 73% deuterium exchange were detected. This residual solvent HDX was observed for both carbohydrates and peptides in multiple instruments and dependent on sample infusion rate, infusion time, and deuterium content of the solvent. This residual solvent HDX was observed over several minutes of sample analysis and persisted long enough to alter the measured deuterium labeling and possibly change the interpretation of the results. This work illustrates that residual solvent HDX competes with in-solution HDX for rapidly exchanging functional groups. Thus, we propose conditions to minimize this effect, specifically for top-down, in-electrospray ionization, and quench-flow HDX experiments. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High density plasmas and new diagnostics: An overview (invited)

One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including “volume-integrated” X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a “pin-hole camera” has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UHECR ESCAPE MECHANISMS FOR PROTONS AND NEUTRONS FROM GAMMA-RAY BURSTS, AND THE COSMIC-RAY-NEUTRINO CONNECTION

The paradigm that gamma-ray burst fireballs are the sources of the ultra-high energy cosmic rays (UHECRs) is being probed by neutrino observations. Very stringent bounds can be obtained from the cosmic-ray (proton)-neutrino connection, assuming that the UHECRs escape as neutrons. In this study, we identify three different regimes as a function of the fireball parameters: the standard ''one neutrino per cosmic ray'' case, the optically thick (to neutron escape) case, and the case where leakage of protons from the boundaries of the shells (direct escape) dominates. In the optically thick regime, the photomeson production is very efficient, and more neutrinos will be emitted per cosmic ray than in the standard case, whereas in the direct escape-dominated regime, more cosmic rays than neutrinos will be emitted. We demonstrate that, for efficient proton acceleration, which is required to describe the observed UHECR spectrum, the standard case only applies to a very narrow region of the fireball parameter space. We illustrate with several observed examples that conclusions on the cosmic-ray-neutrino connection will depend on the actual burst parameters. We also show that the definition of the pion production efficiency currently used by the IceCube collaboration underestimates the neutrino production in the optically thick case. Finally, we point out that the direct escape component leads to a spectral break in the cosmic-ray spectrum emitted from a single source. The resulting ''two-component model'' can be used to even more strongly pronounce the spectral features of the observed UHECR spectrum than the dip model.

79 ASTRONOMY AND ASTROPHYSICS↗

Robotic reconnaissance platform. I. Spectroscopic instruments with rangefinders

In this paper, basic principles of the design and implementation of a portable, multi-functional scientific instrument, operating from a robotic reconnaissance mobile platform are discussed. The current version of the instrument includes a multi-gas laser sensor, multi-functional spectrometer, isotopes identifier, cameras, and rangefinder. An additional set of sensors monitors temperature, pressure, humidity, and background radiation. All components are installed on a mini-robotic platform, which provides data acquisition, processing, and transmittance. The design focuses on the development of calibration-free, reliable, low power-consumption devices. To create a highly survivable, accurate, and reliable instrument, a concept of an inhomogeneous sensory network has been developed. Such a network combines non-identical sensors and provides cross-use of information received from different sensors to describe environmental conditions, to choose appropriate algorithms of data processing, and to achieve high accuracy gas-concentration measurements. The system uses the same lasers to operate different optical devices such as sensors, rangefinders, spectrometers, and isotopes identifiers. Among the innovative elements described in this paper, are a calibration-free, laser multi-gas sensor with range-finding option; a high signal/noise ratio transmittance spectrometer; a single-frequency laser with nano-selector; and low repetition-rate femtosecond fiber lasers operating in near- and middle- infrared spectral ranges. New detailed analyses of absorption spectroscopy theoretical approximations made it possible to achieve high-accuracy gas-concentration measurements with miniature optical sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient thermal stress wave and vibrational analyses of a thin diamond crystal for X-ray free-electron lasers under high-repetition-rate operation

High-brightness X-ray free-electron lasers (FELs) are perceived as fourth-generation light sources providing unprecedented capabilities for frontier scientific researches in many fields. Thin crystals are important to generate coherent seeds in the self-seeding configuration, provide precise spectral measurements, and split X-ray FEL pulses, etc . In all of these applications a high-intensity X-ray FEL pulse impinges on the thin crystal and deposits a certain amount of heat load, potentially impairing the performance. In the present paper, transient thermal stress wave and vibrational analyses as well as transient thermal analysis are carried out to address the thermomechanical issues for thin diamond crystals, especially under high-repetition-rate operation of an X-ray FEL. The material properties at elevated temperatures are considered. It is shown that, for a typical FEL pulse depositing tens of microjoules energy over a spot of tens of micrometers in radius, the stress wave emission is completed on the tens of nanoseconds scale. The amount of kinetic energy converted from a FEL pulse can reach up to ~10 nJ depending on the layer thickness. Natural frequencies of a diamond plate are also computed. The potential vibrational amplitude is estimated as a function of frequency. Here, due to the decreasing heat conductivity with increasing temperature, a runaway temperature rise is predicted for high repetition rates where the temperature rises abruptly after ratcheting up to a point of trivial heat damping rate relative to heat deposition rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Packaging Certification program Methodology for Determining Dose Rates for Small Gram Quantities in Shipping Packagings

The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials (RAM), are significantly less hazardous than large amounts of the same materials. This paper describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package compliant with 10 CFR Part 71 external radiation level limits regulations. These regulations require packaging for the shipment of radioactive materials, under both normal and accident conditions, to perform the essential functions of material containment, subcriticality, and maintain external radiation levels within the specified limits. By placing the contents in a helium leak-tight containment vessel, and limiting the mass to ensure subcriticality, the first two essential functions are readily met. Some isotopes emit sufficiently strong photon radiation that small amounts of material can yield a large dose rate outside the package. Quantifying the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. The Packaging Certification Program (PCP) Methodology for Determining Dose Rate for Small Gram Quantities in Shipping Packagings provides bounding shielding calculations that define mass limits compliant with 10 CFR 71.47 for a set of proposed SGQ isotopes. The approach is based on energy superposition with dose response calculated for a set of spectral groups for a baseline physical packaging configuration. The methodology includes using the MCNP radiation transport code to evaluate a family of neutron and photon spectral groups using the 9977 shipping package and its associated shielded containers as the base case. This results in a set of multipliers for 'dose per particle' for each spectral group. For a given isotope, the source spectrum is folded with the response for each group. The summed contribution from all isotopes determines the total dose from the RAM in the container.

42 ENGINEERING↗

SCExAO/MEC and CHARIS Discovery of a Low-mass, 6 au Separation Companion to HIP 109427 Using Stochastic Speckle Discrimination and High-contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the Microwave Kinetic Inductance Detector Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star point spread function (PSF) subtraction yield 1.1–2.4 μm spectra. MEC reveals the companion in Y and J band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up L {sub p} photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4–M5.5, 3000–3200 K, and log{sub 10}(L/L{sub ⊙})=−2.28{sub −0.04}{sup +0.04}, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia–Hipparcos absolute astrometry of the primary favor a semimajor axis of 6.55{sup +3.0} {sub −0.48} au, an eccentricity of 0.54{sub −0.15}{sup +0.28}, an inclination of 66.7{sub −14}{sup +8.5} degrees, and a dynamical mass of 0.280{sub −0.059}{sup +0.18} M {sub ⊙}. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely used postprocessing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Replica symmetry breaking for the integrable two-site Sachdev–Ye–Kitaev model

We analyze a two-body non-Hermitian two-site Sachdev–Ye–Kitaev (SYK) model with the couplings of one site complex conjugated to the other site. This model, with no explicit coupling between the sites, shows an infinite number of second-order phase transitions, which is a consequence of the factorization of the partition function into a product over Matsubara frequencies. We calculate the quenched free energy in two different ways: first in terms of the single-particle energies and second by solving the Schwinger–Dyson equations of the two-site model. The first calculation can be done entirely in terms of a one-site model. The conjugate replica enters due to non-analyticities when Matsubara frequencies enter the spectral support of the coupling matrix. The second calculation is based on the replica trick of the two-site partition function. Both methods give the same result. The free-fermion partition function can also be rephrased as a matrix model for the coupling matrix. Up to minor details, this model is the random matrix model that describes the chiral phase transition of QCD, and the order parameter of the two-body model corresponds to the chiral condensate of QCD. Comparing to the corresponding four-body model, we are able to determine which features of the free energy are due to the chaotic nature of the four-body model. The high-temperature phase of both models is entropy dominated, and in both cases, the free energy is determined by the spectral density. The chaotic four-body SYK model has a low-temperature phase whose free energy is almost temperature-independent, signaling an effective gap of the theory even though the actual spectrum does not exhibit a gap. On the other hand, the low-temperature free energy of the two-body SYK model is not flat; in fact, it oscillates to arbitrarily low temperature. This indicates a less desirable feature that the entropy of the two-body model is not always positive in the low-temperature phase, which most likely is a consequence of the non-hermiticity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvements to the three-color optical CCD-based pyrometer system

We put forward an improved three-color measurement scheme with a color CCD sensor using the combination of effective wavelengths and blackbody calibrations. The process of effective wavelengths realizes the separation of the emissivity function from the measurement integral equation. This improved method not only effectively avoids errors arising from the traditional process adopting the basic wavelengths, but also simplifies the complex integral calculations. For a blackbody or graybody, the measurement performance of the pyrometer was experimentally investigated from the point of the temperature sensitivity. The results show that narrowing the spectrum bandwidth with different bandpass spectral filters may improve the temperature sensitivities. The spectrum adjustment not only makes the linear emissivity more suitable in the narrower waveband, but also reduces the numerical uncertainty of the effective wavelengths. For nongray objects, the effects of the numerical uncertainty of the effective wavelengths to measurements were quantificationally evaluated at different measurement conditions (different temperatures, emissivities, and spectrums). The results indicate that the reference values of 584, 555, and 511nm or 607, 560, and 506nm of the effective wavelengths are reasonable for the present system with the modified spectral response using Filter 1 or Filter 2. The maximum calculation errors arising from the reference effective wavelengths are less than 1.6%. In this paper, the technical realization steps of the improved method are also described. The measurement experiments of a metal sample in hot environments were carried out to further verify the applicability of this improved CCD-based pyrometer. The results agreed well with the spectrometer-based results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A calibration of NICMOS Camera 2 for low count rates

NICMOS 2 observations are crucial for constraining distances to most of the existing sample of z>1 SNe Ia. Unlike conventional calibration programs, these observations involve long exposure times and low count rates. Reciprocity failure is known to exist in HgCdTe devices and a correction for this effect has already been implemented for high and medium count rates. However, observations at faint count rates rely on extrapolations. Here instead, we provide a new zero-point calibration directly applicable to faint sources. This is obtained via inter-calibration of NIC2 F110W/F160W with the Wide Field Camera 3 (WFC3) in the low count-rate regime using z∼1 elliptical galaxies as tertiary calibrators. These objects have relatively simple near-IR spectral energy distributions, uniform colors, and their extended nature gives a superior signal-to-noise ratio at the same count rate than would stars. The use of extended objects also allows greater tolerances on point-spread function profiles. We find space telescope magnitude zero points (after the installation of the NICMOS cooling system, NCS) of 25.296 ±0.022 for F110W and 25.803 ±0.023 for F160W, both in agreement with the calibration extrapolated from count rates ≳1000 times larger (25.262 and 25.799). Before the installation of the NCS, we find 24.843 ±0.025 for F110W and 25.498 ±0.021 for F160W, also in agreement with the high-count-rate calibration (24.815 and 25.470). We also check the standard bandpasses of WFC3 and NICMOS 2 using a range of stars and galaxies at different colors and find mild tension for WFC3, limiting the accuracy of the zero points. To avoid human bias, our cross-calibration was “blinded” in that the fitted zero-point differences were hidden until the analysis was finalized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗