Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Advances in the growth of alkaline-earth halide single crystals for scintillator detectors

Alkaline-earth scintillators such as strontium iodide and other alkaline-earth halides activated with divalent europium represent some of the most efficient and highest energy resolution scintillators for use as gamma-ray detectors in a wide range of applications. These applications include the areas of nuclear nonproliferation, homeland security, the detection of undeclared nuclear material, nuclear physics and materials science, medical diagnostics, space physics, high energy physics, and radiation monitoring systems for first responders, police, and fire/rescue personnel. Recent advances in the growth of large single crystals of these scintillator materials hold the promise of higher crystal yields and significantly lower detector production costs. In the present work, we describe new processing protocols that, when combined with our molten salt filtration methods, have led to advances in achieving a significant reduction of cracking effects during the growth of single crystals of SrI2:Eu2+. In particular, we have found that extended pumping on the molten crystal-growth charge under vacuum for time periods extending up to 48 hours is generally beneficial in compensating for variations in the alkaline-earth halide purity and stoichiometry of the materials as initially supplied by commercial sources. These melt-pumping and processing techniques are now being applied to the purification of CaI2:Eu2+ and some mixed-anion europium-doped alkaline-earth halides prior to single-crystal growth by means of the vertical Bridgman technique. The results of initial studies of the effects of aliovalent doping of SrI2:Eu2+ on the scintillation characteristics of this material are also described.

energy resolution↗

An Overview of Emerging Nuclear Sensor Technologies: Challenges, Advancements and Applications

Nuclear sensors are essential for detecting and measuring nuclear radiation in various applications, including nuclear power plants, medical imaging, and environmental monitoring. Traditional nuclear sensors have served these fields for decades, but recent advancements in emerging sensor technologies offer novel improvements in accuracy, sensitivity, and reliability. This review presents an up-to-date overview of recent progress in the advancements of nuclear sensor technologies, their diverse applications, challenges in implementation, and opportunities for future research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Group Transport Methods for High-Resolution Neutron Activation Analysis

The accurate and efficient simulation of coupled neutron-photon problems is necessary for various radiation detection applications. Examples include the detection of nuclear threats concealed in cargo containers and prompt gamma neutron activation analysis for nondestructive determination of elemental composition of unknown samples. In these applications, high-resolution gamma-ray spectrometers are used to preserve as much information as possible about the emitted photon flux, which consists of both continuum and characteristic gamma rays with discrete energies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DE-EXCITATION NUCLEAR GAMMA-RAY LINE EMISSION FROM LOW-ENERGY COSMIC RAYS IN THE INNER GALAXY

Recent observations of high ionization rates of molecular hydrogen in diffuse interstellar clouds point to a distinct low-energy cosmic-ray component. Supposing that this component is made of nuclei, two models for the origin of such particles are explored and low-energy cosmic-ray spectra are calculated, which, added to the standard cosmic-ray spectra, produce the observed ionization rates. The clearest evidence of the presence of such low-energy nuclei between a few MeV nucleon{sup -1} and several hundred MeV nucleon{sup -1} in the interstellar medium would be a detection of nuclear {gamma}-ray line emission in the range E {sub {gamma}} {approx} 0.1-10 MeV, which is strongly produced in their collisions with the interstellar gas and dust. Using a recent {gamma}-ray cross section compilation for nuclear collisions, {gamma}-ray line emission spectra are calculated alongside the high-energy {gamma}-ray emission due to {pi}{sup 0} decay, the latter providing normalization of the absolute fluxes by comparison with Fermi-LAT observations of the diffuse emission above E {sub {gamma}} = 0.1 GeV. Our predicted fluxes of strong nuclear {gamma}-ray lines from the inner Galaxy are well below the detection sensitivities of the International Gamma-Ray Astrophysics Laboratory, but a detection, especially of the 4.4 MeV line, seems possible with new-generation {gamma}-ray telescopes based on available technology. We also predict strong {gamma}-ray continuum emission in the 1-8 MeV range, which, in a large part of our model space for low-energy cosmic rays, considerably exceeds the estimated instrument sensitivities of future telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of Argon-37 Background Concentrations in the Atmosphere

Radioisotopes of noble gases, primarily xenon and argon, are important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133 Xe, 135 Xe, 131 mXe and 133 mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37 Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010). Therefore, inclusion of 37 Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations could improve the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37 Ar to evaluate the range of background concentrations. The range of 37 Ar concentrations measured in atmospheric air samples was relatively narrow ranging between less than 1 mBq/m 3 to greater than 2 mBq/m 3 . The average atmospheric concentration of all samples was 0.98 mBq/m 3 , with a standard deviation of 0.5 mBq/m 3 . This is consistent with previous published results. The results presented here demonstrate the capability to detect background concentrations of 37 Ar in atmospheric air.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cosmic Ray Muon Tomography

This presentation discusses muons and their application in detectors, imaging and simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

235 U Determination using In-Beam Delayed Neutron Counting Technique at the NRU Reactor

This paper describes a collaborative effort that saw the Royal Military College of Canada (RMC)’s delayed neutron and gamma counting apparatus transported to Canadian Nuclear Laboratories (CNL) for use in the neutron beamline at the National Research Universal (NRU) reactor. Samples containing mg quantities of fissile material were re-interrogated, and their delayed neutron emissions measured. This collaboration offers significant advantages to previous delayed neutron research at both CNL and RMC. This paper details the determination of 235 U content in enriched uranium via the assay of in-beam delayed neutron magnitudes and temporal behavior. 235 U mass was determined with an average absolute error of ± 2.7 %. This error is lower than that obtained at RMCC for the assay of 235 U content in aqueous solutions (3.6 %) using delayed neutron counting. Delayed neutron counting has been demonstrated to be a rapid, accurate, and precise method for special nuclear material detection and identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microelectronics used for Semiconductor Imaging Detectors

Semiconductor crystal technology, microelectronics developments and nuclear particle detection have been in a relation of symbiosis, all the way from the beginning. The increase of complexity in electronics chips can now be applied to obtain much more information on the incident nuclear radiation. Some basic technologies are described, in order to acquire insight in possibilities and limitations for the most recent detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNM neutron detection using a time-gated synthetic aperture hybrid approach

This work focuses on using forward and adjoint transport in a hybrid application of 3-D deterministic (PENTRAN) and Monte Carlo (MCNP5) codes to model a series of neutron detector blocks. These blocks, or 'channels, ' contain a unique set of moderators with 4 atm He-3 detectors tuned to detect and profile a gross energy spectrum of a passing neutron (SNM) source. Ganging the units together as a large area system enables one to apply time gating the source-detector response to maximize signal to noise responses from a passing source with minimal background; multiple units may be positioned as a collective synthetic aperture detector array to be used as a way of performing real time neutron spectroscopy for detecting special nuclear materials in moving vehicles. The initial design, detector response coupling, confirmation of initial design functionality using adjoint transport calculations, and realistic simulation using PENTRAN and MCNP5 are presented. Future work will include optimization and application to realistic scenarios and additional sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of an In-Field Validation Exercise in Support of Wide-Area Environmental Sampling

The National Nuclear Security Administration’s (NNSA) Office of Nonproliferation and Arms Control (NA-24) is evaluating Wide-Area Environmental Sampling (WAES) as an additional safeguards verification tool for the International Atomic Energy Agency to detect undeclared nuclear activities. The NNSA is evaluating strategies for conducting a generic WAES campaign, the cost of a WAES campaign, and the effect of technological advancements that have occurred since the last major WAES review in 1999. Until now, the NNSA effort has focused on tabletop exercises (TTXs) in which high-performance computing allows for advanced modeling and simulation efforts to be applied to the WAES question. Although the modeling and simulations used in the TTXs are extremely valuable, field campaigns are still needed to validate the assumptions that underpin the models and the modeling process itself. During a 7 week period beginning in May 2023 and ending in June 2023, which included 4 weeks of active field collections, a multilaboratory team conducted its first in-field validation exercise. Prior to the in-field exercise, abbreviated TTXs were conducted to estimate the performance of all collection systems to be used during the field test. These TTXs guided the selection of materials to be released and the placement of the collection system. Based on these determinations, materials were procured to use in the field test, and an injection/release system was designed, built, and installed at the test facility. Background samples were collected during weeks one and four, and environmental collections against active releases were conducted during weeks two and three. The goals of this validation exercise included a demonstration of (1) the ability to provide controlled releases of particulates of surrogate materials, (2) the fielding and operation of collection systems (including deposition and active air collectors), and (3) the flexibility to revise equipment and campaign plans in the field. This paper presents the results and preliminary conclusions for this initial validation test. Based on these results, subsequent field campaigns are anticipated and will include the addition of other released materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental feature in the primary-proton flux at energies above 10 TeV according to the results of searches for primary particles in nuclear emulsions exposed in the stratosphere (RUNJOB Experiment)

In the RUNJOB experiment, a long-term exposure of x-ray emulsion chambers in the stratosphere from 1995 to 1999 with the aim of studying the composition and spectra of primary cosmic particles in the energy range 10-1000 TeV per nucleon revealed about 50% proton tracks. The remaining events of the proton group did not feature any candidate for a track of a singly charged particle within the search region determined from measurements of the coordinates of background nuclei going close to the sought track. Methodological factors that could explain this experimental observation are considered. A possible physical reason associated with the presence of a neutral component in the flux of primary protons in the energy region above 10 TeV is also analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NAMP Radiochemistry Webinars: The Next Educational Tool for the Next Generation Workforce - 18386

With an aging work force and only a few universities offering programs in radiochemistry, laboratories are increasingly finding it more challenging to hire and retain qualified radiochemists. Further, this challenge is a growing trend being seen worldwide. Expertise in radiochemistry is vital to advance our nation's progress in development of the next generation of nuclear reactor technology, drug discovery, environmental stewardship, and the development of technologies to prevent and respond to nuclear terrorist events. The National Analytical Management Program (NAMP) Education and Training subcommittee was established in response to the challenge of promoting radiochemistry and maintaining a well-educated work force to meet the projected growth in nuclear medicine, nuclear energy, safeguards, and nuclear forensics. The NAMP Education and Training subcommittee has offered radiochemistry webinars to a broad audience and is educating and strengthening the knowledge of participants in applications related to actinide and fission products chemistry, sample preparation, detection, dosimetry, nuclear forensics, nuclear fuel cycle, nuclear forensics, and risk assessment. These webinars are presented by renowned experts in the field of Radiochemistry. Additionally, through the partnering of the Education and Training subcommittee with various universities, the NAMP webinars offer a platform for graduate students, PhD candidates, and postdoctoral students to present their research to a wider audience. Since 2012, NAMP has conducted monthly, live webinars - all of which are recorded and archived as an online educational resource to the public from the NAMP web site (http://www.wipp.energy.gov/namp). With over 50 archived presentations, the NAMP webinars provide a comprehensive and interdisciplinary examination of radiochemistry topics. By partnering with university professors and renowned scientific professionals, the NAMP continues to expand the list of webinar topics, increasing the depth of knowledge in this online resource and rapidly becoming the next educational tool in radiochemistry for the next generation workforce. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

Here, we present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3 He-free radiation portal monitor testing campaign at the European Commission’s Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252 Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group’s system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241 Am. Lastly, both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

3He replacement technology↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Software Requirements Document: Benchmarking Algorithm for RadioNuclide Identification (BARNI)

This document provides the requirements for the Benchmark Algorithm for Radio-Nuclide Identification (BARNI) software, an open-source tool for comparing radionuclide identification algorithm performance. It specifies the requirements for the user interface, maintainability, documentation and testing. In addition, this document outlines the core functionality of the product, which will align with the needs of the Office of Nuclear Smuggling Detection and Deterrence (NSDD). Specifically, these include interoperability with RASE, and compatibility with the FLIR R400.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing a detection system for fissile material in nuclear disarmament verification

In arms control treaties, verification plays a crucial role in detecting non-compliance, deterring future violations, and building trust between state parties. Neutron interrogation that induces fission reactions in fissile isotopes and measures the resulting fission neutrons, could be employed for this purpose. This study aims to develop a system which can determine the presence of fissile material while intrinsically protecting information. In this paper, we focus on optimizing the system for discriminating between an enriched uranium block from a depleted uranium (DU) block. The system was built and we report on benchmark measurements with DU and 16% enriched uranium blocks. Furthermore, the Excalibur (Experiment for Calibration with Uranium) neutron source, a neutron spectrometer (redBubble Technology Industries (BTI) N-Probe), and superheated droplet detectors were used for these measurements. MCNP simulations provided insights into detector responses to fissile materials with varying isotopic compositions, confirming that the system functioned as designed.

Active neutron interrogation↗