Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Design of Atomically Precise Nanoscale Negative Differential Resistance Devices

Downscaling device dimensions to the nanometer range raises significant challenges to traditional device design, due to potential current leakage across nanoscale dimensions and the need to maintain reproducibility while dealing with atomic–scale components. Here, negative differential resistance (NDR) devices based on atomically precise graphene nanoribbons are investigated. The computational evaluation of the traditional double–barrier resonant–tunneling diode NDR structure uncovers important issues at the atomic scale, concerning the need to minimize the tunneling current between the leads while achieving high peak current. A new device structure consisting of multiple short segments that enables high current by the alignment of electronic levels across the segments while enlarging the tunneling distance between the leads is proposed. The proposed structure can be built with atomic precision using a scanning tunneling microscope (STM) tip during an intermediate stage in the synthesis of an armchair nanoribbon. An experimental evaluation of the band alignment at the interfaces and an STM image of the fabricated active part of the device are also presented. In conclusion, this combined theoretical–experimental approach opens a new avenue for the design of nanoscale devices with atomic precision.

42 ENGINEERING↗

Pit rim decomposition into multiple quantum dots on surfaces of epitaxial thin films grown on pit-patterned substrates

Here, we report results of dynamical simulations according to an experimentally validated surface morphological evolution model on the formation of regular arrays of quantum dot molecules (QDMs) consisting of 1D arrays of smaller interacting quantum dots (QDs). These QD arrays form along the sides of each pit rim on the surface of a coherently strained thin film epitaxially deposited on a semiconductor substrate, the surface of which consists of a periodic pattern of inverted prismatic pits with rectangular pit openings. We find that this complex QDM pattern results from the decomposition of the pit rim from a “quantum fortress” with four elongated QDs into four 1D arrays of multiple smaller QDs arranged along each side of the pit rim. Systematic parametric analysis indicates that varying the pit opening dimensions and the pit wall inclination directly impacts the number of QDs in the resulting QDM pattern, while varying the pit depth only affects the dimensions of the QDs in the nanostructure pattern. Therefore, the number, arrangement, and sizes of QDs in the resulting pattern of QDMs on the film surface can be engineered precisely by proper tuning of the pit design parameters. Our simulation results are supported by predictions of morphological stability analysis, which explains the pit rim decomposition into multiple QDs as the outcome of a tip-splitting instability and provides a fundamental characterization of the post-instability nanostructure pattern. Our theoretical findings can play a vital role in designing optimal semiconductor surface patterns toward enabling future nanofabrication technologies.

36 MATERIALS SCIENCE↗

Measurement of particle production and inclusive differential cross sections in pp collisions at {radical}(s)=1.96 TeV

We report a set of measurements of particle production in inelastic pp collisions collected with a minimum-bias trigger at the Tevatron Collider with the CDF II experiment. The inclusive charged particle transverse momentum differential cross section is measured, with improved precision, over a range about ten times wider than in previous measurements. The former modeling of the spectrum appears to be incompatible with the high particle momenta observed. The dependence of the charged particle transverse momentum on the event particle multiplicity is analyzed to study the various components of hadron interactions. This is one of the observable variables most poorly reproduced by the available Monte Carlo generators. A first measurement of the event transverse energy sum differential cross section is also reported. A comparison with a pythia prediction at the hadron level is performed. The inclusive charged-particle differential production cross section is fairly well reproduced only in the transverse momentum range available from previous measurements. At higher momentum the agreement is poor. The transverse energy sum is poorly reproduced over the whole spectrum. The dependence of the charged particle transverse momentum on the particle multiplicity needs the introduction of more sophisticated particle production mechanisms, such as multiple parton interactions, in order to be better explained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Blinding multiprobe cosmological experiments

ABSTRACT The goal of blinding is to hide an experiment’s critical results – here the inferred cosmological parameters – until all decisions affecting its analysis have been finalized. This is especially important in the current era of precision cosmology, when the results of any new experiment are closely scrutinized for consistency or tension with previous results. In analyses that combine multiple observational probes, like the combination of galaxy clustering and weak lensing in the Dark Energy Survey (DES), it is challenging to blind the results while retaining the ability to check for (in)consistency between different parts of the data. We propose a simple new blinding transformation, which works by modifying the summary statistics that are input to parameter estimation, such as two-point correlation functions. The transformation shifts the measured statistics to new values that are consistent with (blindly) shifted cosmological parameters while preserving internal (in)consistency. We apply the blinding transformation to simulated data for the projected DES Year 3 galaxy clustering and weak lensing analysis, demonstrating that practical blinding is achieved without significant perturbation of internal-consistency checks, as measured here by degradation of the χ2 between the data and best-fitting model. Our blinding method’s performance is expected to improve as experiments evolve to higher precision and accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A priori precision estimation for neutron triples counting

The nondestructive assay of Plutonium bearing items for criticality, safety, security, safeguards, inventory balance, process control, waste management and compliance is often undertaken using correlated neutron counting. In particular Multiplicity Shift Register analysis allows one to extract autocorrelation parameters from the pulse train which can, within the framework of a simple interpretational model, be related to the effective {sup 240}Pu spontaneous fission mass present. The effective {sup 240}Pu mass is a weighted sum of the {sup 238}Pu, {sup 240}Pu and {sup 242}Pu masses so if the relative isotopic composition of the Pu can be established from the measured {sup 240}Pu effective mass one can estimate the total Pu mass and also the masses of the individual isotopes, example the fissile species {sup 239}Pu and {sup 241}Pu. In multiplicity counting three counting rates are obtained. These are the Singles, Doubles and Triples rates. The Singles rate is just the gross, totals or trigger rate. The Doubles and Triples rates are calculated from factorial moments of the observed signal triggered neutron multiplicity distributions following spontaneous fission in the item and can be thought of as the rate of observed coincident pairs and coincident triplets on the pulse train. Coincident events come about because the spontaneous fission and induced fission chains taking place in the item result in bursts of neutrons. These remain time correlated during the detection process and so retain information, through the burst size distribution, about the Pu content. In designing and assessing the performance of a detector system to meet a given goal it is necessary to make a priori estimates of the counting precision for all three kinds of rates. This is non-trivial because the counting does not obey the familiar rules of a Poissonian counting experiment because the pulse train has time correlated events on it and the train is sampled by event triggered gates that may overlap. For Singles and Doubles simple approximate analytical empirical rules for how to estimate the variance have been developed guided by theory and refined by experiment. However, for Triples no equivalent rules have been put forward and tested until now. In this work we propose an analytical expression, the CSH relation, for the variance on the Triples count and exercise it against experimental data gathered for Pu items measured in the Los Alamos National Laboratory's Epithermal Neutron Multiplicity Counter (ENMC). Preliminary results are encouraging and reasonable agreement with observation, considered fit for scoping studies, is obtained. We have also looked at the behavior using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rethinking radiation effects in materials science using the plasma-focused ion beam

This work demonstrates the viability of using a plasma-focused ion beam (PFIB) as a new platform to carry out radiation effects studies in solids. While materials subjected to irradiation in either nuclear reactors or energetic particle accelerators experience limitations with respect to inaccuracies in both flux measurements and lack of precise control of irradiation areas, we demonstrate a new irradiation technique that allows the exposure of a single specimen in multiple areas, at multiple doses, and in site-specific dependencies - all with flux variations on the order of only 1%. This versatile technique also allows materials to be exposed to significantly higher irradiation dose rates than conventional accelerators. To validate the new methodology, we selected the classical example of ion-beam-induced amorphization of pure single-crystal Si. By pioneering the use of the PFIB for radiation effects studies in materials science, we were able to exploit, in both micro- and nanometer-sized detail, the differences in electron image contrast arising from crystalline versus amorphous solid-state phases in classical semiconductors subjected to irradiation, thus providing new insights on amorphization mechanisms. This methodology opens new research frontiers at the fringe of materials science with promising applications beyond the scope of materials at extremes such as in nanopatterning, nanodevices and nanoarchitectonics.

36 MATERIALS SCIENCE↗

Retrosynthesis of multi–component metal-organic frameworks

Crystal engineering of metal–organic frameworks (MOFs) has allowed the construction of complex structures at atomic precision, but has yet to reach the same level of sophistication as organic synthesis. The synthesis of complex MOFs with multiple organic and/or inorganic components is ultimately limited by the lack of control over framework assembly in one-pot reactions. Herein, we demonstrate that multi-component MOFs with unprecedented complexity can be constructed in a predictable and stepwise manner under simple kinetic guidance, which conceptually mimics the retrosynthetic approach utilized to construct complicated organic molecules. Four multi-component MOFs were synthesized by the subsequent incorporation of organic linkers and inorganic clusters into the cavity of a mesoporous MOF, each composed of up to three different metals and two different linkers. Furthermore, we demonstrated the utility of such a retrosynthetic design through the construction of a cooperative bimetallic catalytic system with two collaborative metal sites for three-component Strecker reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resonant scattering of matter-wave gap solitons by optical lattice defects

The physical mechanism underlying scattering properties of matter-wave gap solitons (GSs) by linear-optical-lattice defects is investigated. The occurrence of repeated reflection, transmission, and trapping regions for increasing strengths of an optical-lattice defect are shown to be due to resonances with impurity modes inside the defect potential with chemical potentials and numbers of atoms matching corresponding quantities of the incoming GSs. For small amplitude GSs the number of these resonances coincides with the number of bound states existing in the defect potential for the given defect strength. The dependence of the positions and widths of the transmission resonant peaks on incoming velocities is investigated by means of defect-mode analysis and effective-mass theory. The comparisons with direct integrations of the Gross-Pitaevskii equation provide good agreement confirming the correctness of our approach. Multiple resonant transmissions through arrays of optical lattice defects are also investigated and the possibility of using them for very precise GS dynamical filters is also suggested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis of Cold Antihydrogen in a Cusp Trap

We report here the first successful synthesis of cold antihydrogen atoms employing a cusp trap, which consists of a superconducting anti-Helmholtz coil and a stack of multiple ring electrodes. This success opens a new path to make a stringent test of the CPT symmetry via high precision microwave spectroscopy of ground-state hyperfine transitions of antihydrogen atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-365: Estimation of Neutron Ambient Dose Equivalents for Radioprotection Exposed Workers in Radiotherapy Facilities Based On Characterization Patient Risk Estimation

Purpose: Previous measurements with Bonner spheres{sup 1} showed that normalized neutron spectra are equal for the majority of the existing linacs{sup 2}. This information, in addition to thermal neutron fluences obtained in the characterization procedure{sup 3}3, would allow to estimate neutron doses accidentally received by exposed workers, without the need of an extra experimental measurement. Methods: Monte Carlo (MC) simulations demonstrated that the thermal neutron fluence distribution inside the bunker is quite uniform, as a consequence of multiple scatter in the walls{sup 4}. Although inverse square law is approximately valid for the fast component, a more precise calculation could be obtained with a generic fast fluence distribution map around the linac, from MC simulations{sup 4}. Thus, measurements of thermal neutron fluences performed during the characterization procedure{sup 3}, together with a generic unitary spectra{sup 2}, would allow to estimate the total neutron fluences and H*(10) at any point{sup 5}. As an example, we compared estimations with Bonner sphere measurements{sup 1}, for two points in five facilities: 3 Siemens (15–23 MV), Elekta (15 MV) and Varian (15 MV). Results: Thermal neutron fluences obtained from characterization, are within (0.2–1.6×10{sup 6}) cm−{sup 2}•Gy{sup −1} for the five studied facilities. This implies ambient equivalent doses ranging from (0.27–2.01) mSv/Gy 50 cm far from the isocenter and (0.03–0.26) mSv/Gy at detector location with an average deviation of ±12.1% respect to Bonner measurements. Conclusion: The good results obtained demonstrate that neutron fluence and H*(10) can be estimated based on: (a) characterization procedure established for patient risk estimation in each facility, (b) generic unitary neutron spectrum and (c) generic MC map distribution of the fast component. [1] Radiat. Meas (2010) 45: 1391 – 1397; [2] Phys. Med. Biol (2012) 5 7:6167–6191; [3] Med. Phys (2015) 42:276 - 281. [4] IFMBE (2012) 39: 1245–1248. [5] ICRU Report 57 (1998)

60 APPLIED LIFE SCIENCES↗

Stastically determined experimental uncertainties in photon Doppler velocimetry (PDV) measurements

Shock-ramp experiments place high demands on the precision, accuracy, and temporal resolution of transformed velocimetry signals. To minimize uncertainty after total propagation of a shockramp experiment, ideally multiple PDV traces are used. However, each trace has some uncertainty that is a function of the PDV system and analysis of the velocimetry data. In order to determine a reasonable experimental estimate of minimum uncertainty, we calculate observed uncertainties in as-fielded PDV systems using multiple channels to sample the velocity on each shot. We also calculate the uncertainty’s sensitivity to choice of analysis methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous Switching of Multiple GaN Transistors in a High-Speed Switch

broadband travelling wave kicker operating with 80 MHz repetition rates is required for the new PIP-II accelerator at Fermilab. We present a technique to drive simultaneously four series-connected enhancement mode GaN-on-silicon power transistors by means of microwave photonics techniques. These four transistors are arranged into a high voltage and high repetition rate switch. Using multiple transistors in series is required to share switching losses. Using a photonic signal distribution system is required to achieve precise synchronization between transistors. We demonstrate 600 V arbitrary pulse generation into a 200 Ohm load with 2 ns rise/fall time. The arbitrary pulse widths can be adjusted from 4 ns to essentially DC.

Frolov, Daniil↗

The Application of MCNP6.2 Unstructured Mesh Geometry Capabilities to the Study of Heavy Ion Single Event Effect on Microelectronic Devices and the Reactor Physics Analysis - 25691

Unstructured meshes allow irregular or complex geometries to be modeled precisely in Monte Carlo radiation transport codes. Through this capability, it is possible to share an unstructured mesh model between multiple codes that use unstructured mesh geometry and thus improving coupled multi-physics simulations. In this work, unstructured meshes are used to model energy deposition from heavy ion strikes for single event effects on microelectronic devices as well as neutron flux mapping of nuclear reactor configurations. In each case, MCNP6.2's unstructured mesh functionality and applicability to the problem is demonstrated and analyzed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of a proton gantry equipped with dual x-ray imagers and a robotic patient positioner, and evaluation of the accuracy of single-beam image registration for this system

Purpose: To check the accuracy of a gantry equipped with dual x-ray imagers and a robotic patient positioner for proton radiotherapy, and to evaluate the accuracy and feasibility of single-beam registration using the robotic positioner. Methods: One of the proton treatment rooms at their institution was upgraded to include a robotic patient positioner (couch) with 6 degrees of freedom and dual orthogonal kilovoltage x-ray imaging panels. The wander of the proton beam central axis, the wander of the beamline, and the orthogonal image panel crosswires from the gantry isocenter were measured for different gantry angles. The couch movement accuracy and couch wander from the gantry isocenter were measured for couch loadings of 50–300 lb with couch rotations from 0° to ±90°. The combined accuracy of the gantry, couch, and imagers was checked using a custom-made 30 × 30 × 30 cm{sup 3} Styrofoam phantom with beekleys embedded in it. A treatment in this room can be set up and registered at a setup field location, then moved precisely to any other treatment location without requiring additional image registration. The accuracy of the single-beam registration strategy was checked for treatments containing multiple beams with different combinations of gantry angles, couch yaws, and beam locations. Results: The proton beam central axis wander from the gantry isocenter was within 0.5 mm with gantry rotations in both clockwise (CW) and counterclockwise (CCW) directions. The maximum wander of the beamline and orthogonal imager crosswire centers from the gantry isocenter were within 0.5 and 0.8 mm, respectively, with the gantry rotations in CW and CCW directions. Vertical and horizontal couch wanders from the gantry isocenter were within 0.4 and 1.3 mm, respectively, for couch yaw from 0° to ±90°. For a treatment with multiple beams with different gantry angles, couch yaws, and beam locations, the measured displacements of treatment beam locations from the one based on the initial setup beam registered at the gantry at 0°/180° and couch yaw at 0° were within 1.5 mm in three translations and 0.5° in three rotations for a 200 lb couch loading. Conclusions: Results demonstrate that the gantry equipped with a robotic patient positioner and dual imaging panels satisfies treatment requirements for proton radiotherapy. The combined accuracy of the gantry, couch, and imagers allows a patient to be registered at one setup position and then moved precisely to another treatment position by commanding the robotic patient positioner and delivering treatment without requiring additional image registration.

07 ISOTOPE AND RADIATION SOURCES↗

Precise Synthesis of Complex Si–Si Molecular Frameworks

In this Perspective, we highlight the emergence of target-oriented syntheses of complex molecules composed of Si–Si (oligosilanes) rather than C–C bonds. Saturated oligosilanes structurally resemble alkanes with respect to a tetrahedral geometry, a preference for a staggered conformation in linear chains, the ability to form stable small rings, and tetrahedral stereochemistry at asymmetrically functionalized Si centers. There are also critical differences, for example, differences in multiple bonding and the ability to form penta- and hexacoordinated structures, that mean that chemical reactivity and, in particular, rules for stereoselective synthesis do not cleanly translate from carbon to silicon. This Perspective will discuss recent achievements in the precise, controlled synthesis of complex molecules comprised mainly of Si–Si bonds and highlight the mechanistic insights enabling increased molecular complexity. New tools, such as electrochemical and catalytic reactions, will be discussed as well as the problem of controlling relative configuration in molecules containing multiple stereogenic-at-silicon centers. Furthermore, these synthetic achievements facilitate the discovery of new properties, including insight into light absorption, conformation, and mechanical properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alignment of Short Reads: A Crucial Step for Application of Next-Generation Sequencing Data in Precision Medicine

Precision medicine or personalized medicine has been proposed as a modernized and promising medical strategy. Genetic variants of patients are the key information for implementation of precision medicine. Next-generation sequencing (NGS) is an emerging technology for deciphering genetic variants. Alignment of raw reads to a reference genome is one of the key steps in NGS data analysis. Many algorithms have been developed for alignment of short read sequences since 2008. Users have to make a decision on which alignment algorithm to use in their studies. Selection of the right alignment algorithm determines not only the alignment algorithm but also the set of suitable parameters to be used by the algorithm. Understanding these algorithms helps in selecting the appropriate alignment algorithm for different applications in precision medicine. Here, we review current available algorithms and their major strategies such as seed-and-extend and q-gram filter. We also discuss the challenges in current alignment algorithms, including alignment in multiple repeated regions, long reads alignment and alignment facilitated with known genetic variants.

59 BASIC BIOLOGICAL SCIENCES↗

A microfluidic platform for precision small-volume sample processing and its use to size separate biological particles with an acoustic microdevice [Precision size separation of biological particles in small-volume samples by an acoustic microfluidic system]

Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection, system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.

42 ENGINEERING↗