Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Controller for Driving a Piezoelectric Actuator at Resonance

A digital control system based partly on an extremum-seeking control algorithm tracks the changing resonance frequency of a piezoelectric actuator or an electrically similar electromechanical device that is driven by a sinusoidal excitation signal and is required to be maintained at or near resonance in the presence of uncertain, changing external loads and disturbances. Somewhat more specifically, on the basis of measurements of the performance of the actuator, this system repeatedly estimates the resonance frequency and alters the excitation frequency as needed to keep it at or near the resonance frequency. In the original application for which this controller was developed, the piezoelectric actuator is part of an ultrasonic/sonic drill/corer. Going beyond this application, the underlying principles of design and operation are generally applicable to tracking changing resonance frequencies of heavily perturbed harmonic oscillators. Resonance-frequency-tracking analog electronic circuits are commercially available, but are not adequate for the present purpose for several reasons: The input/output characteristics of analog circuits tend to drift, often necessitating recalibration, especially whenever the same controller is used in driving a different resonator. In the case of an actuator in a system that has multiple modes characterized by different resonance frequencies, an analog controller can tune erroneously to one of the higher-frequency modes. The lack of programmability of analog controllers is problematic when faults occur, and is especially problematic for preventing tuning to a higher-frequency mode. In contrast, a digital controller can be programmed to restrict itself to a specified frequency range and to maintain stability even when the affected resonator is driven at high power and subjected to uncertain disturbances and variable loads. The present digital control system (see figure) is implemented by means of an algorithm that comprises three main subalgorithms: a hill-climbing control algorithm, an estimation-based extremum-seeking control (ESC) algorithm, and a supervisory algorithm. The hill-climbing algorithm is useful for coarse tracking to find and remain within the vicinity of the resonance. The ESC algorithm is not capable of coarse resonance tracking, but is capable of fine resonance tracking once the estimates of parameters generated by the hill-climbing algorithm have converged sufficiently. On the basis of the parameter-estimation errors, the supervisory algorithm switches operation to whichever of the other two algorithms performs best at a given time.

Aldrich, Jack↗

Propulsion Health Monitoring of a Turbine Engine Disk Using Spin Test Data

This paper considers data collected from an experimental study using high frequency capacitive sensor technology to capture blade tip clearance and tip timing measurements in a rotating turbine engine-like-disk-to predict the disk faults and assess its structural integrity. The experimental results collected at a range of rotational speeds from tests conducted at the NASA Glenn Research Center s Rotordynamics Laboratory are evaluated using multiple data-driven anomaly detection techniques to identify abnormalities in the disk. Further, this study presents a select evaluation of an online health monitoring scheme of a rotating disk using high caliber sensors and test the capability of the in-house spin system.

Abdul-Aziz, Ali↗

Toward resilient high performance applications through real time reliability metric generaion and autonomous failure correction

One predominant barrier encountered in furthering research and development efforts aimed at facilitating resilient HPC applications is a substantial lack of existing reliability and performance data originating from extreme-scale computing distributions. In order to develop an understanding of how and why highly scaled HPC applications are encountering increasingly frequent performance interruptions, one must conduct extensive trending and analysis on contemporary machines and their associated programs. However, existing HPC application log files are labyrinthine documents that, even with the assistance of intelligent data mining algorithms, translate poorly to human discern. In addition, conventional log filtering, processes are limited to execution within a post-mortem, reactive time period, as the enormous size of these documents prevents efficient real time interaction. Thus, there exists a strong need within the HPC field for the provision of accurate-yet-concise real time application information. Moreover, the means of reporting this data must be sufficiently lightweight and non-intrusive, as to successfully-yet-discretely attach itself to the multiple processes running on multiple cores within tens (or in some cases, hundreds) of thousands of compute nodes. Furthermore, this information should in turn be used to facilitate the autonomous correction of application-threatening faults, suspensions, and interruptions. This paper describes a dynamic application instrumentation module (utilizing a combination of Open/SpeedShop software and custom scripting) aimed at successfully achieving these goals.

97 MATHEMATICS AND COMPUTING↗

Distributed Energy Communications & Controls, Lab Activities - Summary

The purpose is to develop controls for inverter-based renewable and non-renewable distributed energy systems to provide local voltage, power and power quality support for loads and the power grid. The objectives are to (1) develop adaptive controls for inverter-based distributed energy (DE) systems when there are multiple inverters on the same feeder and (2) determine the impact of high penetration high seasonal energy efficiency ratio (SEER) air conditioning (A/C) units on power systems during sub-transmission faults which can result in an A/C compressor motor stall and assess how inverter-based DE can help to mitigate the stall event. The Distributed Energy Communications & Controls Laboratory (DECC) is a unique facility for studying dynamic voltage, active power (P), non-active power (Q) and power factor control from inverter-based renewable distributed energy (DE) resources. Conventionally, inverter-based DE systems have been designed to provide constant, close to unity power factor and thus not provide any voltage support. The DECC Lab interfaces with the ORNL campus distribution system to provide actual power system testing of the controls approach. Using mathematical software tools and the DECC Lab environment, we are developing and testing local, autonomous and adaptive controls for local voltage control and P & Q control for inverter-based DE. We successfully tested our active and non-active power (P,Q) controls at the DECC laboratory along with voltage regulation controls. The new PQ control along with current limiter controls has been tested on our existing inverter test system. We have tested both non-adaptive and adaptive control modes for the PQ control. We have completed several technical papers on the approaches and results. Electric power distribution systems are experiencing outages due to a phenomenon known as fault induced delayed voltage recovery (FIDVR) due to air conditioning (A/C) compressor motor stall. Local voltage collapse from FIDVR is occurring in part because modern air-conditioner and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip than older motors. These motors can stall in less than three cycles (0.05 s) when a fault, for example, on the sub-transmission system, causes voltage on the distribution system to sag to 70% or less of nominal. We completed a new test system for A/C compressor motor stall testing at the DECC Lab. The A/C Stall test system is being used to characterize when and how compressor motors stall under low voltage and high compressor pressure conditions. However, instead of using air conditioners, we are using high efficiency heat pumps. We have gathered A/C stall characterization data for both sustained and momentary voltage sags of the test heat pump. At low enough voltage, the heat pump stalls (compressor motor stops and draws 5-6 times normal current in trying to restart) due to low inertia and low torque of the motor. For the momentary sag, we are using a fast acting contactor/switch to quickly switch from nominal to the sagged voltage in cycles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extensions to the Parallel Real-Time Artificial Intelligence System (PRAIS) for fault-tolerant heterogeneous cycle-stealing reasoning

Extensions to an architecture for real-time, distributed (parallel) knowledge-based systems called the Parallel Real-time Artificial Intelligence System (PRAIS) are discussed. PRAIS strives for transparently parallelizing production (rule-based) systems, even under real-time constraints. PRAIS accomplished these goals (presented at the first annual C Language Integrated Production System (CLIPS) conference) by incorporating a dynamic task scheduler, operating system extensions for fact handling, and message-passing among multiple copies of CLIPS executing on a virtual blackboard. This distributed knowledge-based system tool uses the portability of CLIPS and common message-passing protocols to operate over a heterogeneous network of processors. Results using the original PRAIS architecture over a network of Sun 3's, Sun 4's and VAX's are presented. Mechanisms using the producer-consumer model to extend the architecture for fault-tolerance and distributed truth maintenance initiation are also discussed.

Goldstein, David↗

Operator-in-the-Loop Study for a Computerized Operator Support System (COSS) – Cross-System and System-Independent Evaluations

The Computerized Operator Support System (COSS) is an operator assistive technology funded by the U.S. Department of Energy Office of Nuclear Energy and developed at Idaho National Laboratory. The project works in collaboration with an advanced prognostics system called PRO-AID developed at Argonne National Laboratory. The COSS provides a human-machine interface to help operators maintain situation awareness and detect faults earlier than would be possible using conventional control room technologies at nuclear power plants. This report represents a status report outlining third-year efforts to develop and validate the COSS. The COSS has now been implemented as a prototype system, with multiple interaction design concepts on multiple plant systems in the simulator from a commercial nuclear power plant. Two studies involving three licensed reactor crews were conducted to evaluate the COSS. This report captures insights into the development of COSS as well as operator feedback and future development guidance derived from the operator-in-the-loop simulator studies.

99 GENERAL AND MISCELLANEOUS↗

Precursory Locking Precedes Slip Events on Laboratory Fault

Earthquakes occur through repeated cycles of locking and slip. What is the relationship between transiently locked patches and the size, location, and timing of the subsequent slip events? Here we use an experimental fault made of transparent rubber to image the slip history of over 18,000 events. The soft elastic system allows for contained ruptures and thus a natural evolution of stress heterogeneity over multiple earthquake cycles. We observe a precursory locking phase preceding slip nucleation for events of all sizes. The integrated locking distance increases linearly with the moment of the eventual event. The most intense (largest slip deficit) locking events are spatially and temporally correlated with the hypocenters of the largest rupture events. These results show that the transient locking is statistically, but not deterministically, predictive of the location, timing, and size of the eventual slip event.

earthquakes↗

Elimination of trench defects and V-pits from InGaN/GaN structures

The microstructural evolution of InGaN/GaN multiple quantum wells grown by metalorganic chemical vapor phase epitaxy was studied as a function of the growth temperature of the GaN quantum barriers (QBs). We observed the formation of basal stacking faults (BSFs) in GaN QBs grown at low temperature. The presence of BSFs terminated by stacking mismatch boundaries (SMBs) leads to the opening of the structure at the surface into a V-shaped trench loop. This trench may form above an SMB, thereby terminating the BSF, or above a junction between the SMB and a subsequent BSF. Fewer BSFs and thus fewer trench defects were observed in GaN QBs grown at temperatures higher than 830 °C. Further increase in the growth temperature of the GaN QBs led to the suppression of the threading dislocation opening into V-pits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Cryogenic Muon Tagging System Integrated with a Superconducting Qubit Device for Radiation-Induced Error Mitigation

Superconducting qubits are highly sensitive to ionizing radiation, which can induce correlated errors and limit scalable fault-tolerant quantum computing. In particular, cosmic-ray muons can deposit energy in the substrate, generating phonon bursts that break Cooper pairs and produce quasiparticles, leading to correlated decoherence events across multiple qubits. We present the development of a cryogenic muon tagging system based on Kinetic Inductance Detectors (KIDs) and its integration with superconducting quantum hardware. Originally developed within the ACE-SuperQ project and validated as a standalone detector, the system demonstrated a muon tagging efficiency of approximately 90% and excellent agreement with Monte Carlo simulations. Building on this validation, the tagging system has been integrated with a multi-qubit superconducting chip operated in a dilution refrigerator. The detector configuration consists of a multi-layer KID stack arranged above and below the quantum device, enabling time-coincident identification of muon-induced events within the same cryogenic environment. The integrated setup has been successfully commissioned, enabling simultaneous operation of the qubit chip and the muon tagging system. A first measurement campaign has been carried out, and preliminary data show time-correlated events between the muon tagging detectors and the qubit readout. A quantitative analysis of radiation-induced effects on qubit performance is currently ongoing. This work represents a step toward the implementation of event-level radiation tagging as a tool for characterizing and potentially mitigating correlated errors in superconducting quantum processors, while establishing a modular platform for future studies at the interface between particle physics and quantum information science.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

A Case Study on the Challenges and Opportunities for the Deployment of PHM Capabilities in Existing Engineering Systems

The field of Prognostics and Health Management (PHM) of engineering systems has experienced considerable growth over the last decade. From benefits associated with faster and more powerful hardware in the form of wireless sensors, edge devices, and general computing capabilities (GPU’s and cloud computing), to development of powerful algorithms for anomaly detection and remaining useful life (RUL) estimation, the number of engineering systems featuring advanced diagnostics and prognostics capabilities continues to grow at an increasingly faster pace. However, the deployment of PHM capabilities as part of the upgrade of existing engineering systems presents multiple challenges to the PHM practitioner charged with retrofitting such systems. Issues include a lack of specific instrumentation needed to capture the signals of interest; insufficient data and sampling rates required for fault detection and diagnosis, and for detection of failure/degradation indicators; and difficulties in the identification of a system’s nominal behavior as a result of age induced degradation. Today’s PHM practitioner must be able to quickly identify and assess these types of issues to effectively evaluate and select the optimal PHM strategies required to achieve the desired results. This paper presents results from the preliminary evaluation of the High-Pressure Gas Facility (HPGF) infrastructure at NASA’s Stennis Space Center in Hancock County, Mississippi. This evaluation is part of a feasibility study conducted prior to the deployment of prognostics and diagnostics capabilities in the pumps skids of the liquid nitrogen (LN2) system of the HPGF.

Condition Based Maintenance↗

Non-destructive observation of in-grown stacking faults in 4H-SiC epitaxial layer using mirror electron microscope

Mirror electron microscope (MEM) observation has been conducted for a 4-{mu}m-thick n-doped 4H-SiC epitaxial layer. If the sample is simultaneously illuminated with ultraviolet (UV) light of a slightly greater energy than the bandgap energy of 4H-SiC, in-grown stacking faults (IGSFs) can be clearly observed in MEM images. These observations were performed non-destructively, as almost all irradiated electrons returned without impinging the sample surface due to the negative voltage applied to the sample. High spatial resolution observation via MEM showed that multiple IGSFs were stacked up. The phenomenon in which the contrast of the IGSFs vanished in the absence of UV illumination and under UV illumination with a lower energy than the bandgap energy revealed that the origin of the contrast was the negative charging of IGSFs trapping electrons excited by UV light.

36 MATERIALS SCIENCE↗

A new presentation of complex voltage data for Goldstone radar astronomy

A presentation method similar to a vector field display or a data-based grid has been used to visualize complex voltage test data taken over multiple subchannels. Unlike simple plots of all data points on the complex plane, the position of the data in the time series is part of the presentation, providing additional information to aid in fault isolation during readiness testing. The 'phase-magnitude' presentation, as it has come to be called, was designed for the demands of real-time data acquisition and processing with remote monitoring over low bandwidth communication links.

Howard, S. D.↗

DYNAMIC PRA OF A MULTI-UNIT PLANT

Dynamic Probabilistic Risk Analysis (PRA) methods couple stochastic methods (e.g., RAVEN, ADAPT, ADS, MCDET) with safety analysis codes (RELAP5-3D, MELCOR, MAAP) to determine risk associated to complex systems such as nuclear plants. Compared to classical PRA methods, which are based on static logic structures (e.g., Event-Trees, Fault-Trees), they can evaluate with higher resolution the safety impact of timing and sequencing of events on the accident progression. Recently, special attention has been given to nuclear plants which consist of multiple units and, in particular, on the safety impact of system dependencies, shared systems and common resources on core damage frequencies. In the literature, while classical PRA methods have been employed to model multi-unit plants, Dynamic PRA methods have never been applied to analyze a full multi-unit model. This paper presents a PRA analysis of a multi-unit plant using Dynamic PRA methods. We employ RAVEN as stochastic method coupled with RELAP5-3D. The plant under consideration consists of the three units and their associated spent fuel pools (SFPs). The studied initiating event is a seismic induced station blackout event. We will describe in detail how the multi-unit plant has been constructed and, in particular, how unit dependencies and shared resources are modeled.

97 MATHEMATICS AND COMPUTING↗

NASA Space Flight Vehicle Fault Isolation Challenges

The Space Launch System (SLS) is the new NASA heavy lift launch vehicle and is scheduled for its first mission in 2017. The goal of the first mission, which will be uncrewed, is to demonstrate the integrated system performance of the SLS rocket and spacecraft before a crewed flight in 2021. SLS has many of the same logistics challenges as any other large scale program. Common logistics concerns for SLS include integration of discrete programs geographically separated, multiple prime contractors with distinct and different goals, schedule pressures and funding constraints. However, SLS also faces unique challenges. The new program is a confluence of new hardware and heritage, with heritage hardware constituting seventy-five percent of the program. This unique approach to design makes logistics concerns such as testability of the integrated flight vehicle especially problematic. The cost of fully automated diagnostics can be completely justified for a large fleet, but not so for a single flight vehicle. Fault detection is mandatory to assure the vehicle is capable of a safe launch, but fault isolation is another issue. SLS has considered various methods for fault isolation which can provide a reasonable balance between adequacy, timeliness and cost. This paper will address the analyses and decisions the NASA Logistics engineers are making to mitigate risk while providing a reasonable testability solution for fault isolation.

Bramon, Christopher↗

Blockchain for Fault-Tolerant Grid Operations Version 2.0

This report explores the potential of distributed ledger technology (DLT) as a transformative tool to enhance fault-tolerant operations in electrical distribution systems. Leveraging DLT's core attributes, including an immutable decentralized ledger, distributed consensus mechanisms, and state replication capabilities, this study focuses on three critical use cases. A central aspect of this research centers on the utilization of a consensus-driven ledger, providing actors within the system, such as distributed resources, with access to a reliable data repository. This empowers these actors to collaborate effectively and make informed decisions, all securely recorded on the blockchain. The first use case concentrates on data configuration, utilizing mathematical criteria---particularly, the chi-squared test for gross error detection---to identify trustworthy sensors for advanced decision-making. Building upon this foundation of trust, the second use case, topology identification, accurately determines circuit breaker states, unveiling the distribution network's topology. Ultimately, the third use case leverages this trust to execute switching actions, reconfiguring feeders and restoring power to disconnected customers after fault events. The concept of trust serves as a cornerstone in this approach, marking a departure from traditional fault location, isolation, and service restoration (FLISR) methods. Additionally, the blockchain-based architecture introduces decentralization, empowering disconnected areas to make autonomous decisions, even when communication with a central control center is disrupted. The primary contributions of this report are twofold: (1) a novel approach for evaluating distribution system voltage areas while preserving data ownership and (2) the implementation of interactions between distribution network areas using the actor model. Unlike the previous sequential approach for evaluating the area connection voltages, which required a radial network topology, this study's area model reduction enables a more versatile approach. The area model reduction addresses issues of prolonged data waiting times and multiple points of failure within the previous approach. Notably, the presented evaluation for the reduced network model area connection reveals a significant increase in the differences in voltage magnitudes. Simulation and evaluation of area agents across four distinct cases elucidate the area-level interaction behavior during a fault event. Simulations demonstrate that the proposed distributed FLISR (DFLISR) approach can successfully restore service to an affected area. Varying message delays and message loss probabilities in each simulation case underscore their impacts on restoration times, ranging from 3 min and 32 s to 6 min and 19 s. In contrast, power is not restored in an area in one of our simulation cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability Model Generator for fault-tolerant systems

This paper discusses an analysis tool, the Reliability Model Generator, that reasons from structural and functional system design specifications to generate a reliability model for the system under investigation. The resultant model defines a system state space sufficient to characterize the effects of single and multiple component failures. This model may then be examined by the analyst or used as input to an existing reliability evaluation tool, the Semi-Markov Unreliability Range Evaluator (SURE), to compute numeric bounds for system reliability (i.e., safety, mission success, availability, etc.). In defining the input to the Reliability Model Generator, a separation of the component function from structural specification is proposed to allow easy modification for analysis of alternative architectures. A hierarchical system description paradigm promotes multiple abstractions, thereby enabling analysis at all phases of the design process. The work described in this paper has been supported under NASA contract NAS1-10899, Integrated Airframe/Propulsion Control System Architecture (IAPSA II). IAPSA II promotes a system engineering methodology and supporting analytical tools to evaluate flight control architecture configuration alternatives during early phases of the design cycle when the cost and schedule impact of design revisions is minimal. Emphasis is placed on traceability to ensure that the requirements drive the resulting design.

Catherine M McCann↗

Vectoring into Potential Blind Geothermal Systems in the Granite Springs Valley Area, Western Nevada: Application of the Play Fairway Analysis at Multiple Scales

The Great Basin region of the western USA is capable of generating much greater amounts of geothermal energy than currently produced. Most geothermal resources in this region are blind, and thus the favorable characteristics for geothermal activity must be synthesized and methodologies developed to discover new commercial-grade systems. The geothermal play fairway concept involves integration of multiple parameters indicative of geothermal activity as a means of identifying promising areas for new development. In the Nevada play fairway project, nine geologic, geochemical, and geophysical parameters were initially synthesized to produce a new geothermal potential map of 96,000 km2. Granite Springs Valley in western Nevada is a particularly promising site selected for detailed study. It contains several favorable structural settings, including terminations of major Quaternary normal faults and fault intersections. Geologic, geophysical, and geochemical techniques were employed to define the most likely sites for high permeability and select drilling targets for temperature-gradient holes. Local and intermediate permeability models were revised to reflect results of detailed analyses and generate new detailed play fairway maps of the area. The most promising site lies in the northeastern part of the basin directly east of Adobe Flat, where the horse-tailing termination of a major normal fault (as revealed by new gravity data), opaline sinter deposits, warm shallow wells, and a low-resistivity anomaly are collocated. Geothermometry suggests a blind system with temperatures as high as ~130°C in this area. Four new temperature-gradient holes document temperatures of ~80°C at ~150 m depth. Lessons learned in the detailed studies of this project include: 1) initially identified sites commonly include multiple favorable settings at a finer scale; 2) promising sites in Cenozoic basins cannot be well defined without detailed geophysical surveys; and 3) play fairway analysis is critical at multiple scales, providing a means to select regional prospects as well as vectoring into drilling targets at individual sites.

15 GEOTHERMAL ENERGY↗

A flight expert system (FLES) for on-board fault monitoring and diagnosis

The increasing complexity of modern aircraft creates a need for a larger number of caution and warning devices. But more alerts require more memorization and higher work loads for the pilot and tend to induce a higher probability of errors. Therefore, an architecture for a flight expert system (FLES) to assist pilots in monitoring, diagnosing and recovering from in-flight faults has been developed. A prototype of FLES has been implemented. A sensor simulation model was developed and employed to provide FLES with the airplane status information during the diagnostic process. The simulator is based partly on the Lockheed Advanced Concept System (ACS), a future generation airplane, and partly on the Boeing 737, an existing airplane. A distinction between two types of faults, maladjustments and malfunctions, has led us to take two approaches to fault diagnosis. These approaches are evident in two FLES subsystems: the flight phase monitor and the sensor interrupt handler. The specific problem addressed in these subsystems has been that of integrating information received from multiple sensors with domain knowledge in order to assess abnormal situations during airplane flight. This paper describes the reasons for handling malfunctions and maladjustments separately and the use of domain knowledge in the diagnosis of each.

Ali, M.↗