Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

FIRST RESULTS FROM Pan-STARRS1: FAINT, HIGH PROPER MOTION WHITE DWARFS IN THE MEDIUM-DEEP FIELDS

The Pan-STARRS1 survey has obtained multi-epoch imaging in five bands (Pan-STARRS1 g{sub P1}, r{sub P1}, i{sub P1}, z{sub P1}, and y{sub P1}) on 12 'Medium-Deep fields', each of which spans a 3.{sup 0}3 circle. For the period between 2009 April and 2011 April these fields were observed 50-200 times. Using a reduced proper motion diagram, we have extracted a list of 47 white dwarf (WD) candidates whose Pan-STARRS1 astrometry indicates a non-zero proper motion at the 6{sigma} level, with a typical 1{sigma} proper motion uncertainty of 10 mas yr{sup -1}. We also used astrometry from the Sloan Digital Sky Survey (when available) and USNO-B to assess our proper motion fits. None of the WD candidates exhibits evidence of statistically significant parallaxes, with a typical 1{sigma} uncertainty of 8 mas. Twelve of these candidates are known WDs, including the high proper motion (1.''7 yr{sup -1}) WD LHS 291. We confirm seven more objects as WDs through optical spectroscopy. Based on the Pan-STARRS1 colors, ten of the stars are likely to be cool WDs with 4170 K <T{sub eff} < 5000 K and cooling ages Almost-Equal-To 8 Gyr. Based on their kinematics, these objects are likely thick disk WDs, but a subset may belong to the halo. Our current sample represents only a small fraction of the Pan-STARRS1 data. With continued coverage from the Medium-Deep Field Survey and the 3{pi} survey, Pan-STARRS1 should find many more high proper motion WDs that are part of the old thick disk and halo.

79 ASTRONOMY AND ASTROPHYSICS↗

THIRD-EPOCH MAGELLANIC CLOUD PROPER MOTIONS. I. HUBBLE SPACE TELESCOPE/WFC3 DATA AND ORBIT IMPLICATIONS

We present proper motions for the Large and Small Magellanic Clouds (LMC and SMC) based on three epochs of Hubble Space Telescope data, spanning a {approx}7 yr baseline, and centered on fields with background QSOs. The first two epochs, the subject of past analyses, were obtained with ACS/HRC, and have been reanalyzed here. The new third epoch with WFC3/UVIS increases the time baseline and provides better control of systematics. The three-epoch data yield proper-motion random errors of only 1%-2% per field. For the LMC this is sufficient to constrain the internal proper-motion dynamics, as will be discussed in a separate paper. Here we focus on the implied center-of-mass proper motions: {mu} {sub W,LMC} = -1.910 {+-} 0.020 mas yr{sup -1}, {mu} {sub N,LMC} = 0.229 {+-} 0.047 mas yr{sup -1}, and {mu} {sub W,SMC} = -0.772 {+-} 0.063 mas yr{sup -1}, {mu} {sub N,SMC} = -1.117 {+-} 0.061 mas yr{sup -1}. We combine the results with a revised understanding of the solar motion in the Milky Way to derive Galactocentric velocities: v {sub tot,LMC} = 321 {+-} 24 km s{sup -1} and v {sub tot,SMC} = 217 {+-} 26 km s{sup -1}. Our proper-motion uncertainties are now dominated by limitations in our understanding of the internal kinematics and geometry of the Clouds, and our velocity uncertainties are dominated by distance errors. Orbit calculations for the Clouds around the Milky Way allow a range of orbital periods, depending on the uncertain masses of the Milky Way and LMC. Periods {approx}< 4 Gyr are ruled out, which poses a challenge for traditional Magellanic Stream models. First-infall orbits are preferred (as supported by other arguments as well) if one imposes the requirement that the LMC and SMC must have been a bound pair for at least several Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Beam Motion on Observed Image at Imaging Station C

Imaging Station C on the DARHT II accelerator is used to measure beam spot sizes. Solenoid scans are used to measure the spot sizes as a function of the solenoid current and infer the beam emittance. Beam motion is observed during the measurement window and can contribute to the measured spot size. The effect of beam motion on the observed images at Station C is examined in this note. The variation in the beam position during the kicked beam pulse contributes to the beam spot size as measured at Station C. The beam motion is primarily in the vertical plane and is due to the kicker voltage rise time prior to the solenoid magnet. The effect of beam motion on the spot size is studied using LAMDA. From the measured beam position at BPM28 and BPM29 we determine the beam position and angle at the start of the LAMDA simulation. We then calculate the beam motion at Station C as a function of the S4 solenoid magnet current. The shot-to-shot variation in the beam motion is very small.

43 PARTICLE ACCELERATORS↗

THE ALLWISE MOTION SURVEY, PART 2

We use the AllWISE Data Release to continue our search for Wide-field Infrared Survey Explorer ( WISE )-detected motions. In this paper, we publish another 27,846 motion objects, bringing the total number to 48,000 when objects found during our original AllWISE motion survey are included. We use this list, along with the lists of confirmed WISE -based motion objects from the recent papers by Luhman and by Schneider et al., and candidate motion objects from the recent paper by Gagné et al., to search for widely separated, common-proper-motion systems. We identify 1039 such candidate systems. All 48,000 objects are further analyzed using color–color and color–mag plots to provide possible characterizations prior to spectroscopic follow-up. We present spectra of 172 of these, supplemented with new spectra of 23 comparison objects from the literature, and provide classifications and physical interpretations of interesting sources. Highlights include: (1) the identification of three G/K dwarfs that can be used as standard candles to study clumpiness and grain size in nearby molecular clouds because these objects are currently moving behind the clouds, (2) the confirmation/discovery of several M, L, and T dwarfs and one white dwarf whose spectrophotometric distance estimates place them 5–20 pc from the Sun, (3) the suggestion that the Na i “D” line be used as a diagnostic tool for interpreting and classifying metal-poor late-M and L dwarfs, (4) the recognition of a triple system including a carbon dwarf and late-M subdwarf, for which model fits of the late-M subdwarf (giving [Fe/H] ≈ −1.0) provide a measured metallicity for the carbon star, and (5) a possible 24 pc distant K5 dwarf + peculiar red L5 system with an apparent physical separation of 0.1 pc.

79 ASTRONOMY AND ASTROPHYSICS↗

Revised and New Proper Motions for Confirmed and Candidate Milky Way Dwarf Galaxies

A new derivation of systemic proper motions of Milky Way satellites is presented and applied to 59 confirmed or candidate dwarf galaxy satellites using Gaia Data Release 2. This constitutes all known Milky Way dwarf galaxies (and likely candidates) as of 2020 May, except for the Magellanic Clouds, the Canis Major and Hydra 1 stellar overdensities, and the tidally disrupting Bootes III and Sagittarius dwarf galaxies. We derive systemic proper motions for the first time for Indus 1, DES J0225+0304, Cetus 2, Pictor 2, and Leo T, but note that the latter three rely on photometry that is of poorer quality than that of the rest of the sample. We cannot resolve a signal for Bootes 4, Cetus 3, Indus 2, Pegasus 3, or Virgo 1. Our method is inspired by the maximum likelihood approach of Pace & Li and examines simultaneously the spatial, color–magnitude, and proper motion distribution of sources. Systemic proper motions are derived without the need to identify confirmed radial velocity members, although the proper motions of these stars, where available, are incorporated into the analysis through a prior on the model. The associated uncertainties on the systemic proper motions are on average a factor of ∼1.4 smaller than existing literature values. Analysis of the implied membership distribution of the satellites suggests that we accurately identify member stars with a contamination rate lower than 1 in 20.

79 ASTRONOMY AND ASTROPHYSICS↗

Radio measurements of the stellar proper motions in the core of the orion nebula cluster

Using multi-epoch Very Large Array observations, covering a time baseline of 29.1 years, we have measured the proper motions of 88 young stars with compact radio emission in the core of the Orion Nebula Cluster (ONC) and the neighboring BN/KL region. Our work increases the number of young stars with measured proper motion at radio frequencies by a factor of 2.5 and enables us to perform a better statistical analysis of the kinematics of the region than was previously possible. Most stars (79 out of 88) have proper motions consistent with a Gaussian distribution centered on (μ{sub α}cos δ)-bar =1.07±0.09 mas yr{sup −1}, and (μ{sub δ})-bar =−0.84±0.16 mas yr{sup −1}, with velocity dispersions of σ{sub α}=1.08±0.07 mas yr{sup −1}, σ{sub δ}=1.27±0.15 mas yr{sup −1}. We looked for organized movements of these stars but found no clear indication of radial expansion/contraction or rotation. The remaining nine stars in our sample show peculiar proper motions that differ from the mean proper motions of the ONC by more than 3σ. One of these stars, V 1326 Ori, could have been expelled from the Orion Trapezium 7000 years ago. Two could be related to the multi-stellar disintegration in the BN/KL region, in addition to the previously known sources BN, I and n. The others either have high uncertainties (so their anomalous proper motions are not firmly established) or could be foreground objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatial scale of motion segmentation from speed cues

For the accurate perception of multiple, potentially overlapping, surfaces or objects, the visual system must distinguish different local motion vectors and selectively integrate similar motion vectors over space to segment the retinal image properly. We recently showed that large differences in speed are required to yield a percept of motion transparency. In the present study, to investigate the spatial scale of motion segmentation from speed cues alone, we measured the speed-segmentation threshold (the minimum speed difference required for 75% performance accuracy) for 'corrugated' random-dot patterns, i.e. patterns in which dots with two different speeds were alternately placed in adjacent bars of variable width. In a first experiment, we found that, at large bar widths, a smaller speed difference was required to segment and perceive the corrugated pattern of moving dots, while at small bar-widths, a larger speed difference was required to segment the two speeds and perceive two transparent surfaces of moving dots. Both the perceptual and segmentation performance transitions occurred at a bar width of around 0.4 degrees. In a second experiment, speed-segmentation thresholds were found to increase sharply when dots with different speeds were paired within a local pooling area. The critical pairing distance was about 0.2 degrees in the fovea and increased linearly with stimulus eccentricity. However, across the range of eccentricities tested (up to 15 degrees ), the critical pairing distance did not change much and remained close to the receptive field size of neurons within the primate primary visual cortex. In a third experiment, increasing dot density changed the relationship between speed-segmentation thresholds and bar width. Thresholds decreased for large bar widths, but increased for small bar widths. All of these results are well fit by a simple stochastic model, which estimates the probabilities of having identical or different motion vectors within a local pooling area whose size is the same as that of primate V1 neurons. Altogether, these results demonstrate that speed-based segmentation can function well, even at small spatial scales (i.e. high-spatial frequencies of spatial corrugation) and thereby emphasizes the critical role of a local pooling process early in the cortical motion-processing pathway.

NASA Discipline Neuroscience↗

Spacelab experiments on space motion sickness

Recent research results from ground and flight experiments on motion sickness and space sickness conducted by the Man Vehicle Laboratory are reviewed. New tools developed include a mathematical model for motion sickness, a method for quantitative measurements of skin pallor and blush in ambulatory subjects, and a magnitude estimation technique for ratio scaling of nausea or discomfort. These have been used to experimentally study the time course of skin pallor and subjective symptoms in laboratory motion sickness. In prolonged sickness, subjects become hypersensitive to nauseogenic stimuli. Results of a Spacelab-1 flight experiment are described in which four observers documented the stimulus factors for and the symptoms/signs of space sickness. The clinical character of space sickness differs somewhat from acute laboratory motion sickness. However SL-1 findings support the view that space sickness is fundamentally a motion sickness. Symptoms were subjectively alleviated by head movement restriction, maintenance of a familiar orientation with respect to the visual environment, and wedging between or strapping onto surfaces which provided broad contact cues confirming the absence of body motion.

Flight Experiment↗

The barberplaid illusion: plaid motion is biased by elongated apertures

The perceived direction of motion of plaids windowed by elongated spatial Gaussians is biased toward the window's long axis. The bias increases as the relative angle between the plaid motion and the long axis of the window increases, peaks at a relative angle of approximately 45 deg, and then decreases. The bias increases as the window is made narrower (at fixed height) and decreases as the component spatial frequency increases (at fixed aperture size). We examine several models of human motion processing (cross-correlation, motion-energy, intersection-of-constraints, and vector-sum), and show that none of these standard models can predict our data. We conclude that spatial integration of motion signals plays a crucial role in plaid motion perception and that current models must be explicitly expanded to include such spatial interactions.

NASA Center ARC↗

1st- and 2nd-order motion and texture resolution in central and peripheral vision

STIMULI. The 1st-order stimuli are moving sine gratings. The 2nd-order stimuli are fields of static visual texture, whose contrasts are modulated by moving sine gratings. Neither the spatial slant (orientation) nor the direction of motion of these 2nd-order (microbalanced) stimuli can be detected by a Fourier analysis; they are invisible to Reichardt and motion-energy detectors. METHOD. For these dynamic stimuli, when presented both centrally and in an annular window extending from 8 to 10 deg in eccentricity, we measured the highest spatial frequency for which discrimination between +/- 45 deg texture slants and discrimination between opposite directions of motion were each possible. RESULTS. For sufficiently low spatial frequencies, slant and direction can be discriminated in both central and peripheral vision, for both 1st- and for 2nd-order stimuli. For both 1st- and 2nd-order stimuli, at both retinal locations, slant discrimination is possible at higher spatial frequencies than direction discrimination. For both 1st- and 2nd-order stimuli, motion resolution decreases 2-3 times more rapidly with eccentricity than does texture resolution. CONCLUSIONS. (1) 1st- and 2nd-order motion scale similarly with eccentricity. (2) 1st- and 2nd-order texture scale similarly with eccentricity. (3) The central/peripheral resolution fall-off is 2-3 times greater for motion than for texture.

Pattern Recognition, Visual/physiology↗

Utilizing Commercial Hardware and Open Source Computer Vision Software to Perform Motion Capture for Reduced Gravity Flight

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts. To perform validation of these models and to support the Advanced Exercise Concepts Project, several candidate devices have been flown onboard NASAs Reduced Gravity Aircraft. In terrestrial laboratories, researchers typically have available to them motion capture systems for the measurement of subject kinematics. Onboard the parabolic flight aircraft it is not practical to utilize the traditional motion capture systems due to the large working volume they require and their relatively high replacement cost if damaged. To support measuring kinematics on board parabolic aircraft, a motion capture system is being developed utilizing open source computer vision code with commercial off the shelf (COTS) video camera hardware. While the systems accuracy is lower than lab setups, it provides a means to produce quantitative comparison motion capture kinematic data. Additionally, data such as required exercise volume for small spaces such as the Orion capsule can be determined. METHODS: OpenCV is an open source computer vision library that provides the ability to perform multi-camera 3 dimensional reconstruction. Utilizing OpenCV, via the Python programming language, a set of tools has been developed to perform motion capture in confined spaces using commercial cameras. Four Sony Video Cameras were intrinsically calibrated prior to flight. Intrinsic calibration provides a set of camera specific parameters to remove geometric distortion of the lens and sensor (specific to each individual camera). A set of high contrast markers were placed on the exercising subject (safety also necessitated that they be soft in case they become detached during parabolic flight); small yarn balls were used. Extrinsic calibration, the determination of camera location and orientation parameters, is performed using fixed landmark markers shared by the camera scenes. Additionally a wand calibration, the sweeping of the camera scenes simultaneously, was also performed. Techniques have been developed to perform intrinsic calibration, extrinsic calibration, isolation of the markers in the scene, calculation of marker 2D centroids, and 3D reconstruction from multiple cameras. These methods have been tested in the laboratory side-by-side comparison to a traditional motion capture system and also on a parabolic flight.

Biodynamics↗

Modified Autogenic Feedback Training Produces Effect on Motion Sickness

Motion sickness is a common physiological reaction to provocative motion and is characterized by a constellation of symptoms, including stomach awareness, nausea, emesis, pallor, sweating, hypersalivation, and fatigue. The emergence of these symptoms can pose a significant threat to safety, particularly in the context of aviation. Given its prevalence among aviators and its detrimental impact on performance, researchers have endeavored to identify effective countermeasures for motion sickness. Currently, many of the existing interventions are pharmacological in nature and while effective, they present a problem due to their associated adverse side effects. A modified two-hour version of Autogenic Feedback Training Exercise (AFTE) could be an effective countermeasure to motion sickness without adverse side effects. AFTE combines principles of autogenic therapy, biofeedback, and learning to teach individuals to control their own internal physiological reactions through a series of relaxation and arousal exercises. AFTE was administered over six days. On the first day, participants were exposed to provocative motion via a rotating chair test to collect baseline physiological data. AFTE sessions were conducted on four consecutive days and lasted approximately 30 minutes each session. Participants were exposed to the rotating chair again on the 6th day. Results: Participants (n = 16) were evaluated on the number of rotations experienced and cumulative minutes spun in the chair. Participants tended to ride longer (M = 21.0 min, SD = 16.56) and tolerated more rotations (M = 244.8 rotations, SD = 310.62) on their second rotating chair test compared to baseline (M = 14.0 min, SD = 9.35; M = 125.8 rotations, SD = 124.08; t(15) = 2.21, p = .02). A moderate effect size was recorded (Hedges’s g = 0.44). A modified two-hour version of the AFTE is effective at increasing tolerance of symptoms associated with motion sickness.

motion sickness↗

Characteristics of Vertical Ground Motions and Their Effect on the Seismic Response of Bridges in the Near-Field: A State-of-the-Art Review

Despite the evidence from past earthquakes and several numerical investigations demonstrating the detrimental impact of vertical ground motions (VGMs) on the integrity of bridge structures, incorporating their effects into seismic assessment and design procedures has traditionally been given limited consideration. Current codes utilize rather simplistic approaches to account for the concurrent effects of vertical and horizontal motions in structural performance evaluations, potentially leading to unconservative estimates of structural demands. This paper reviews the main features of VGMs and their effect on the seismic response of bridges. The methods and empirical models available to estimate vertical motions for design purposes are discussed, and research gaps and related research needs are identified. Finally, the emerging role of physics-based ground-motion simulations, as well as their limitations, in supporting future research and informing the development of simplified design procedures is examined. The main areas of interest for future research are identified in the need to carry out systematic sensitivity studies to gain insight into the main earthquake parameters that influence key VGMs features, understand the influence of soil nonlinearities on VGMs amplitude and frequency content, inform the development of empirical models that cover a range of site conditions and source-to-site distances where current models are poorly constrained, generate arrays of motions to update coherency models to properly inform the analysis of distributed infrastructure, investigate the impulsive character of VGMs, and assess the approximations made in estimating VGMs with 1D site response analyses. Furthermore, specific focus is laid on large-magnitude earthquakes in the near-field.

Asynchronous ground motion↗

Vortex motion on surfaces of small curvature

We consider a single Abelian Higgs vortex on a surface Σ whose Gaussian curvature K is small relative to the size of the vortex, and analyse vortex motion by using geodesics on the moduli space of static solutions. The moduli space is Σ with a modified metric, and we propose that this metric has a universal expansion, in terms of K and its derivatives, around the initial metric on Σ. Using an integral expression for the Kähler potential on the moduli space, we calculate the leading coefficients of this expansion numerically, and find some evidence for their universality. The expansion agrees to first order with the metric resulting from the Ricci flow starting from the initial metric on Σ, but differs at higher order. We compare the vortex motion with the motion of a point particle along geodesics of Σ. Relative to a particle geodesic, the vortex experiences an additional force, which to leading order is proportional to the gradient of K. This force is analogous to the self-force on bodies of finite size that occurs in gravitational motion. -- Highlights: •We study an Abelian Higgs vortex on a surface with small curvature. •A universal expansion for the moduli space metric is proposed. •We numerically check the universality at low orders. •Vortex motion differs from point particle motion because a vortex has a finite size. •Moduli space geometry has similarities with the geometry arising from Ricci flow.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of Antiflatulent Dietary Advice on Intrafraction Motion for Prostate Cancer Radiotherapy

Purpose: To evaluate the effect of an antiflatulent dietary advice on the intrafraction prostate motion in patients treated with intensity-modulated radiotherapy (IMRT) for prostate cancer. Methods and Materials: Between February 2002 and December 2009, 977 patients received five-beam IMRT for prostate cancer to a dose of 76 Gy in 35 fractions combined with fiducial markers for position verification. In July 2008, the diet, consisting of dietary guidelines to obtain regular bowel movements and to reduce intestinal gas by avoiding certain foods and air swallowing, was introduced to reduce the prostate motion. The intrafraction prostate movement was determined from the portal images of the first segment of all five beams. Clinically relevant intrafraction motion was defined as {>=}50% of the fractions with an intrafraction motion outside a range of 3 mm. Results: A total of 739 patients were treated without the diet and 105 patients were treated with radiotherapy after introduction of the diet. The median and interquartile range of the average intrafraction motion per patient was 2.53 mm (interquartile range, 2.2-3.0) without the diet and 3.00 mm (interquartile range, 2.4-3.5) with the diet (p < .0001). The percentage of patients with clinically relevant intrafraction motion increased statistically significant from 19.1% without diet to 42.9% with a diet (odds ratio, 3.18; 95% confidence interval, 2.07-4.88; p < .0001). Conclusions: The results of the present study suggest that antiflatulent dietary advice for patients undergoing IMRT for prostate cancer does not reduce the intrafraction movement of the prostate. Therefore, antiflatulent dietary advice is not recommended in clinical practice for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Management of Respiration-Induced Motion With 4-Dimensional Computed Tomography (4DCT) for Pancreas Irradiation

Purpose: The purposes of this study were to quantify respiration-induced organ motions for pancreatic cancer patients and to explore strategies to account for these motions. Methods and Materials: Both 3-dimensional computed tomography (3DCT) and 4-dimensional computed tomography (4DCT) scans were acquired sequentially for 15 pancreatic cancer patients, including 10 randomly selected patients and 5 patients selected from a subgroup of patients with large tumor respiratory motions. 3DCTs were fused with 2 sets of 4DCT data at the end of exhale phase (50%) and the end of inhale phase (0%). The target was delineated on the 50% and 0% phase CT sets, and the organs at risk were drawn on the 3DCT. These contours were populated to the CT sets at other respiratory phases based on deformable image registration. Internal target volumes (ITV) were generated by tracing the target contours of all phases (ITV{sub 10}), 3 phases of 0%, 20% and 50% (ITV{sub 3}), and 2 phases of 0% and 50% (ITV{sub 2}). ITVs generated from phase images were compared using percentage of volume overlap, Dice coefficient, geometric centers, and average surface distance. Results: Volume variations of pancreas, kidneys, and liver as a function of respiratory phases were small (<5%) during respiration. For the 10 randomly selected patients, peak-to-peak amplitudes of liver, left kidney, right kidney, and the target along the superior-inferior (SI) direction were 7.9 ± 3.2 mm, 7.1 ± 3.1 mm, 5.7 ± 3.2 mm, and 5.9 ± 2.8 mm, respectively. The percentage of volume overlap and Dice coefficient were 92% ± 1% and 96% ± 1% between ITV{sub 10} and ITV{sub 2} and 96% ± 1% and 98% ± 1% between ITV{sub 10} and ITV{sub 3}, respectively. The percentage of volume overlap between ITV{sub 10} and ITV{sub 3} was 93.6 ± 1.1 for patients with tumor motion >8 mm. Conclusions: Appropriate motion management strategies are proposed for radiation treatment planning of pancreatic tumors based on magnitudes of tumor respiratory motions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗