Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

V-grooved silicon solar cells

Silicon solar cells with macroscopic V-shaped grooves and microscopically texturized surfaces were made by preferential etching techniques. Various conditions for potassium hydroxide and hydrazine hydrate etching were investigated. Optical reflection losses from these surface were reduced. The reduced reflection occurred at all wavelengths and resulted in improved short circuit current and spectral response. Improved collection efficiency is also expected from this structure due to generation of carriers closer to the cell junction. Microscopic point measurements of collected current using a scanning electron microscope showed that current collected at the peaks of the texturized surface were only 80 percent of those collected in the valleys.

Baraona, C. R.↗

Plasma instability modes related to the earth's bow shock

The present work examines the status of physical interpretations of some of the microscopic phenomena occurring in bow shock structures. A categorization of microscopic phenomena is given, and it is examined how various modes may or may not be invoked in explaining spacecraft measurements on bow structure. The macroscopic and observational context of the bow shock as presently understood is first defined, and then some of the microscopic plasma physical phenomena which might be expected to be found associated with certain macroscopic structures are outlined. Some problems in the use of the bow shock to test plasma shock theory are then discussed.

Greenstadt, W. W.↗

V-grooved silicon solar cells

Silicon solar cells with macroscopic V-shaped grooves and microscopically texturized surfaces have been made by preferential etching techniques. Various conditions for potassium hydroxide and hydrazine hydrate etching were investigated. Optical reflection losses from these surface were reduced. The reduced reflection occurred at all wavelengths and resulted in improved short circuit current and spectral response. Improved collection efficiency is also expected from this structure due to generation of carriers closer to the cell junction. Microscopic point measurements of collected current using a scanning electron microscope showed that current collected at the peaks of the texturized surface were only 80% of those collected in the valleys.

Baraona, C. R.↗

Microstructural characterization of the HRSI thermal protection system for space shuttle

Components of the space shuttle high temperature reusable surface insulation (HRSI) system were microscopically characterized, both separately and as a system, to obtain information needed for stress analysis models of the thermal protection system. A tension specimen of the HRSI system was loaded in steps and was microscopically observed at each load condition to demonstrate the tension failure mode associated with strain isolation pad (SIP) behavior. A local failure occurred which should be associated with transfer of load through transverse fibers in the SIP. Stress concentrations attributed to the SIP behavior necessitated strengthening of the HRSI by densification of the RSI at the bondline. An HRSI tile was microscopically characterized after the densification process. The densified surface layer blended into the RSI which caused a gradual change in density. The gradation in density does not appear to represent a sharp discontinuity in elastic modulus between the densified layer and the parent material.

Ransone, P. O.↗

Digital image processing of bone - Problems and potentials

The development of a digital image processing system for bone histomorphometry and fluorescent marker monitoring is discussed. The system in question is capable of making measurements of UV or light microscope features on a video screen with either video or computer-generated images, and comprises a microscope, low-light-level video camera, video digitizer and display terminal, color monitor, and PDP 11/34 computer. Capabilities demonstrated in the analysis of an undecalcified rat tibia include the measurement of perimeter and total bone area, and the generation of microscope images, false color images, digitized images and contoured images for further analysis. Software development will be based on an existing software library, specifically the mini-VICAR system developed at JPL. It is noted that the potentials of the system in terms of speed and reliability far exceed any problems associated with hardware and software development.

Morey, E. R.↗

Effect of matrix resin on the impact fracture characteristics of graphite-epoxy laminates

The effect of resin chemistry on basic impact energy absorbent mechanisms exibited by graphite-epoxy composites was investigated. Impact fracture modes and microscopic resin deformation characteristics were examined for 26 NASA-impacted graphite epoxy laminates with different resin chemistries. Discrete specimen fracture modes were identified through cross sectional examination after impact, and subsequently compared with measured glass transition temperatures, cure cycles, and residual impact capabilities. Microscopic resin deformation mechanisms and their overall relationship to impact loading conditions, voids, and resin content were also characterized through scanning electron microscopic examination of separated fracture surfaces.

Hertzberg, P. E.↗

Asymmetric electroosmotic flow and mobility measurements at nonstationary positions in the rectangular chamber

The electrophoretic mobility of a cell in solution is defined by its velocity divided by the electric field strength it experiences. An obvious way to measure the mobility of cells is to apply a constant electric field to a suspension of cells in a glass chamber and clock the velocities of individual cells through a microscope. This microscope method is the classic technique in cell electrophoresis and it has been used for the bulk of research in this field. Two aspects of the microscope method can critically affect the accuracy and consistency of its cell mobility measurements: (1) the electroosmotic fluctuations in the chamber from measurement to measurement; and (2) the number of cells which can be practically measured for statistically meaningful results. A new method of analyzing microelectrophoretic data using a computer program has been developed which addresses both of these aspects. It makes possible the mobility measurements of individual cells as positions throughout the rectangular chamber depth during asymmetric electroosmotic flow.

Source record↗

Observations of a monotectic solidification interface morphology

For detailed studies of the region around a solidification interface on a microscopic scale, a very thin (essentially two-dimensional) test cell may be translated across two temperature-controlled heating/cooling blocks and viewed with a microscope. Such a device is sometimes referred to as a temperature gradient microscope stage (TGS). Of particular interest in this study is the behavior of a monotectic type solution during solidification. Succinonitrile based model systems for metallic monotectic alloys, when solidified on a TGS, form an unusual 'worm-like' micromorphology. These interfaces are observable in situ under high optical magnification during growth.

Kaukler, W. F.↗

Time-dependent fracture strength of oriented polymers

A statistical consideration based upon a theory of microscopic molecular kinetics is developed to describe the time-dependent fracture process for oriented polymers. The interrelation between the macroscopic fracture strength and the microscopic behaviors is formulated with the aid of a double Fourier series expansion. The microscopic behavior in the vicinity of a point is expressed in the form of a spherical function which can be expanded into a series of symmetric tensorial terms. Subsequently, the fracture strength of polymers is evaluated in terms of both time and molecular orientation. By taking account of the individual values of the directional fraction of integrity, the time to fracture and the most probable direction of fracture within any volume element in a medium are predicted.

Mun, M. S.↗

Plasma sprayed Fe(76)Nd(16)B(8) permanent magnets

Thin coatings (0.16 mm) and thick coatings (0.50 mm) of Fe(76)Nd(16)B(8) were deposited on stainless-steel substrates by low pressure plasma spraying. Microscopic examination of the coatings in a light microscope revealed excessive porosity, but good bonding to the substrate. Fracture cross sections examined in a scanning electron microscope showed the grains to be equiaxed and approximately 1 micron or less in diameter in the as-sprayed condition. The intrinsic coercivities of the as-sprayed coatings varied from 5.8 to 10.9 kOe. The effects of postspray heat treatments on the intrinsic coercivity are also given.

Overfelt, R. A.↗

Chemical interactions between the present-day Martian atmosphere and surface minerals

Thermochemical and photochemical reactions between surface minerals and present-day atmospheric constituents are predicted to produce microscopic effects on the surfaces of mineral grains. Relevant reactions hypothesized in the literature include conversions of silicates and volcanic glasses to clay minerals, conversion of ferrous to ferric compounds, and formation of carbonates, nitrates, and sulfates. These types of surface-atmosphere interactions are important for addressing issues such as chemical weathering of minerals, biological potential of the surface environment, and atmospheric stability in both present and past Martian epochs. It is emphasized that the product of these reactions will be observable and interpretable on the microscopic surface layers of Martian surface rocks using modern techniques with obvious implications for sample return from Mars. Macroscopic products of chemical weathering reactions in past Martian epochs are also expected in Martian surface material. These products are expected not only as a result of reactions similar to those proceeding today but also due to aqueous reactions in past epochs in which liquid water was putatively present. It may prove very difficult or impossible however to determine definitively from the relic macroscopic product alone either the exact weathering process which led to its formation or the identity of its weathered parent mineral. The enormous advantages of studying Martian chemical weathering by investigating the microscopic products of present-day chemical reactions on sample surfaces are very apparent.

Prinn, Ronald↗

Chemical interactions between the present-day Martian atmosphere and surface minerals: Implications for sample return

Thermochemical and photochemical reactions between surface minerals and present-day atmospheric constituents are predicted to produce microscopic effects on the surface of mineral grains. Relevant reactions hypothesized in the literature include conversions of silicates and volcanic glasses to clay minerals, conversion of ferrous to ferric compounds, and formation of carbonates, nitrates, and sulfates. These types of surface-atmosphere weathering of minerals, biological potential of the surface environment, and atmospheric stability in both present and past Martian epochs. It is emphasized that the product of these reactions will be observable and interpretable on the microscopic surface layers of Martian surface rocks using modern techniques with obvious implications for sample return from Mars. Macroscopic products of chemical weathering reactions in past Martian epochs are also expected in Martian surface materials. These products are expected not only as a result of reactions similar to those proceeding today but also due to aqueous reactions in past epochs in which liquid water was putatively present. It may prove very difficult or impossible, however, to determine definitively from the relic macroscopic product alone either the exact weathering process which led to its formation of the identity of its weathering parent mineral. The enormous advantages of studying the Martian chemical weathering by investigating the microscopic products of present-day chemical reactions on sample surfaces are very apparent.

Prinn, Ronald↗

Vacuum Chuck Holds Filter Pad For Counting Particles

Microscope-stage holder keeps filter pad flat to keep it in focus. Specimen holder is special vacuum chuck that applies suction through flat screen. Suction keeps filter pad flat against specimen holder while microscope stage moving to scan areas denoted by grid. In microscope system equipped with video camera, image-analyzing/particle-counting computer, and automatic focus, use of stage speeds count considerably by eliminating need to stop frequently for manual refocusing. Technician free to perform other tasks while computer controls translation of stage and takes count automatically.

Berry, Anthony↗

Data reduction of digitized images processed from calibrated photographic and spectroscopic films obtained from terrestial, rocket and space shuttle telescopic instruments

The Microvax 2 computer, the basic software in VMS, and the Mitsubishi High Speed Disk were received and installed. The digital scanning tunneling microscope is fully installed and operational. A new technique was developed for pseudocolor analysis of the line plot images of a scanning tunneling microscope. Computer studies and mathematical modeling of the empirical data associated with many of the film calibration studies were presented. A gas can follow-up experiment which will be launched in September, on the Space Shuttle STS-50, was prepared and loaded. Papers were presented on the structure of the human hair strand using scanning electron microscopy and x ray analysis and updated research on the annual rings produced by the surf clam of the ocean estuaries of Maryland. Scanning electron microscopic work was conducted by the research team for the study of the Mossbauer and Magnetic Susceptibility Studies on NmNi(4.25)Fe(.85) and its Hydride.

Hammond, Ernest C., Jr.↗

Particulate impacts on the UHCRE cosmic ray experiment teflon covers: The ESA programme

The optical scanning equipment at the University of Kent Unit for Space Science consists of a 102.5 by 42.5 cm computer controlled motorized stage which has a reproduction accuracy of 30 microns over the entire area. This is used with an optical microscope connected to two charge coupled device video cameras which can be used to obtain stereo color images of any features found. A coordinate system can be defined on each cover by means of two or more reference marks which allow a feature to be located using different equipment such as a scanning electron microscope, providing two known marks can be found. By using back illumination, penetrating features can be found automatically, and their sizes, circularity, and positions logged for later revisiting either on the optical system or using a scanning electron microscope.

Mcdonnell, J. A. M.↗

A densitometric analysis of commercial 35mm films

IIaO films have been subjected to various sensitometric tests. The have included thermal and aging effects and reciprocity failure studies. In order to compare the special IIaO film with popular brands of 35 mm films and their possible use in astrophotography, Agfa, Fuji and Kodak print and slide formats, as well as black and white and color formats, were subjected to sensitometric, as well as densitometric analysis. A scanning electron microscope was used to analyze grain structure size, and shape as a function of both speed and brand. Preliminary analysis of the grain structure using an ISI-SS40 scanning electron microscope indicates that the grain sizes for darker densities are much larger than the grain size for lighter densities. Researchers analyze the scanning electron microscope findings of the various grains versus densities as well as enhancement of the grains, using the IP-8500 Digital Image Processor.

Hammond, Ernest C., Jr.↗

Electron microscopy study of the iron meteorite Santa Catharina

A characterization of the microstructural features of Santa Catharina (SC) from the millimeter to submicron scale is presented. The same specimen was examined using an optical microscope, a scanning electron microscope, an electron probe microanalyzer, and an analytical electron microscope. Findings include the fact that SC metal nodules may have different bulk Ni values, leading to different microstructures upon cooling; that SC USNM 6293 is the less corroded sample, as tetrataenite exists as less than 10 nm ordered domains throughout the entire fcc matrix (it is noted that this structure is the same as that of the Twin City meteorite and identical to clear taenite II in the retained taenite regions of the octahedrites); that SC USNM 3043 has a more complicated microstructure due to corrosion; and that the low Ni phase of the cloudy zone was selectively corroded in some areas and formed the dark regions, indicating that the SC meteorite corrosion process was electrochemical in nature and may involve Cl-containing akaganeite.

Zhang, J.↗

Visualization of DNA molecules in time during electrophoresis

For several years individual DNA molecules have been observed and photographed during agarose gel electrophoresis. The DNA molecule is clearly the largest molecule known. Nevertheless, the largest molecule is still too small to be seen using a microscope. A technique developed by Morikawa and Yanagida has made it possible to visualize individual DNA molecules. When these long molecules are labeled with appropriate fluorescence dyes and observed under a fluorescence microscope, although it is not possible to directly visualize the local ultrastructure of the molecules, yet because they are long light emitting chains, their microscopic dynamical behavior can be observed. This visualization works in the same principle that enables one to observe a star through a telescope because it emits light against a dark background. The dynamics of individual DNA molecules migrating through agarose matrix during electrophoresis have been described by Smith et al. (1989), Schwartz and Koval (1989), and Bustamante et al. (1990). DNA molecules during agarose gel electrophoresis advance lengthwise thorough the gel in an extended configuration. They display an extension-contraction motion and tend to bunch up in their leading ends as the 'heads' find new pores through the gel. From time to time they get hooked on obstacles in the gel to form U-shaped configurations before they resume their linear configuration.

Lubega, Seth↗