Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Radio frequency performance of DSS 14 64-meter antenna at X-band using an improved subreflector

The performance of the Deep Space Station (DSS) 14 64-meter antenna X-band gain determined using the X- and K-band Radar feedcone is discussed. Tests prior to, and following the installation of an improved subreflector, proved the unit largely (if not totally) restored initial performance levels at that station. The X-band peak gain with the subreflector is +17.8dBi(area efficiency of 47.3 percent); an increase of +0.47 dB due to the unit installation. The test further showed a significant shift in the axial focus required (function of elevation angle) which, if not implemented operationally, will cause a serious degradation. An historical summary of all documented X-band gain measurements at DSS 14 is included and reviewed. The initial performance is traced through various major configuration changes such as the installation of the X-band dual hybrid mode horn within the operational XRO feedcone. Finally, based on the summary and recent data, a peak X-band antenna gain of +72.1 dBi (area efficiency of 50.8 percent) is projected for the operational feedcone.

Freiley, A. J.↗

Laser velocimetry technique applied to the Langley 0.3 meter transonic cryogenic tunnel

A low power laser velocimeter operating in the forward scatter mode was used to measure free stream mean velocities in the Langley 0.3 Meter Transonic Cryogenic Tunnel. Velocity ranging from 51 to 235 m/s was measured. Measurements were obtained for a variety of nominal tunnel conditions: Mach numbers from 0.20 to 0.77, total temperatures from 100 to 250 K, and pressures from 101 to 152 kPa. Particles were not injected to augment the existing Mie scattering materials. Liquid nitrogen droplets were the existing liqht scattering material. Tunnel vibrations and thermal effects had no detrimental effects on the optical system.

Gartrell, L. R.↗

The 34-meter antenna drive control system

Detailed definitions of the baseline antenna drive and control/instrumentation equipment for 34 meter antennas included in Network Consolidation Program of the Deep Space Network are presented. The overall antenna control and monitor system and its interfaces with other higher level control and monitor equipment is described. Explicit descriptions of the antenna axis drive motors and motor controllers, the axis angle encoding systems, and miscellaneous antenna located components are presented, and related to system functional and performance requirements. Some potential alternates to the baseline system configuration are described and discussed.

Source record↗

NASA 3-Meter Infrared Telescope Facility at Mauna Kea

The demonstrated pointing, tracking and offsetting characteristics of the NASA 3-meter infrared telescope are reviewed. Other special features of the telescope such as low thermal background and versatile chopping secondary are also discussed. Experience is presented as to why these design features are important when making infrared observations of astronomical objects.

Becklin, E. E.↗

The Calculated and Measured Performance Characteristics of a Heated-Wire Liquid-Water-Content Meter for Measuring Icing Severity

Ground tests have been made of an instrument which, when assembled in a more compact form for flight installation, could be used to obtain statistical flight data on the liquid-water content of icing clouds and to provide an indication of icing severity. The sensing element of the instrument consists of an electrically heated wire which is mounted in the air stream. The degree of cooling of the wire resulting from evaporation of the impinging water droplets is a measure. of the liquid-water content of the cloud. Determination of the value of the liquid-water content from the wire temperature at any instant requires a knowledge of the airspeed, altitude, and air temperature. An analysis was made of the temperature response of a heated wire exposed to an air stream containing water drops. Comparisons were made of the liquid-water content as measured with several heated wires and absorbent cylinders in an artificially produced cloud. For one of the wires, comparative tests were made with a rotating-disk icing-rate meter in an icing wind tunnel. From the test results, it was shown that an instrument for measuring the concentration of liquid water in an air stream can be built using an electrically heated wire of known temperatureresistance characteristics, and that the performance of such a device can be predicted using appropriate theory. Although an instrument in a form suitable for gathering statistical data in flight was not built, the practicability of constructing such an instrument was illustrated. The ground-test results indicated that a flight heated-wire instrument would be simple and durable, would respond rapidly to variations in liquid-water content, and could be used for the measurement of water content in clouds which are above freezing temperature, as well as in icing clouds.

Neel, Carr B.↗

Comparison of Three Multicylinder Icing Meters and Critique of Multicylinder Method

Three multicylinder cloud meters, fundamentally similar but differing in important details, were compared in use at the Mount Washington Observatory. Determinations of liquid water content were found to agree within the limits of the probable error, but the two instruments designed by the National Advisory Committee for Aeronautics indicated larger drop sizes than did the Observatory's instrument, apparently because of spurious ice catch on the rather rough surface of the larger cylinders. Comparisons of drop-size distribution were largely indeterminate., In a critique of the method, the probable error of determination of liquid water content was found to be +/-8 percent; of drop size, +/-6 percent; and of drop-size distribution, about +/-0.7 unit of the modulus of distribution. Of the systematic errors, run-off of unfrozen water is most important, blow-off and erosion seldom being hampering. Revision of collection-efficiency computations for cylinders in clouds with distributed drop sizes was found necessary and also revision of one of the correction-factor graphs heretofore used. The assumption of constant ice density in deriving cylinder size was found to be permissible for cylinders 1 inch or more in diameter.

Howell, Wallace E.↗

Device Stores and Discharges Metered Fluid

Hand-held container accepts measured amount of liquid from pressurized supply. Supply pressure drives spring-loaded piston that stores enough mechanical energy to discharge measured liquid into another container. Original application of container was to rehydrate sterilized pre-packaged food in zerogravity environment of space vehicles. Possible terrestrial applicatios include dispensing of toxic fluids or metering of fluids for household, commercial or laboratory uses.

Hooper, S. L.↗

Rehabilitation of 64-meter-antenna radial bearing

The performances of the radial bearings on three 64-meter antennas are presented. Explanations for the distortion of the bearing at DSS 14 are made and the repairs are described. Recommendations for future tests and action are given.

Mcginness, H.↗

Ion Drift Meter for Dynamics Explorer

The ion drift meter for Dynamics Explorer B is discussed. It measures two mutually perpendicular angles of arrival of thermal ions with respect to the sensor look directions. These angles lie in the vertical and horizontal planes and may be thought of as pitch and yaw in the conventional aerodynamic sense. The components of the ion drift velocity along vertical and horizontal axes through the spacecraft body are derived to first order from knowledge of the spacecraft velocity vector and more accurately with additional knowledge of the component of ion drift along the sensor look direction.

Heelis, R. A.↗

Flow visualization in the Langley 0.3-meter Transonic Cryogenic Tunnel and preliminary plans for the National Transonic Facility

Design problems associated with the integration of flow visualization in cryogenic facilities are discussed. The possible effects from the cryogenic environment (i.e., window distortion due to thermal contraction both in the mounts and in the window material itself and turbulence in the flow due to injected LN2) are examined. The flow visualization techniques studied are schlieren, shadowgraph, moire deflectometry, and holographic interferometry. The test beds for this work are a Langley in-house cryogenic test chamber and the 0.3-Meter Transonic Cryogenic Tunnel.

Rhodes, D. B.↗

Seeing through flows in Langley's 0.3-meter Transonic Cryogenic Tunnel

Viewing problems associated with the measurement of model deformation in cryogenic wind tunnels are discussed. Tests were conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel to assess viewing capabilities thru the flow field. The effects of condensation and turbulent boundary layers are discussed and a modelling procedure for image degradation is described.

Snow, W. L.↗

Applications of a laser velocimeter in the Langley 4- by 7-meter tunnel

Applications of a laser velocimeter in the Langley 4 by 7 meter wind tunnel are discussed. The system configuration is described. The data acquisition, the laser velocimeter traversing, and the particle generating systems are discussed. Flow distribution and rotor wake applications are discussed.

Sellers, W. L.↗

Laser Doppler velocimetry application in the Langley 0.3-meter Transonic Cryogenic Tunnel

The problems and the potential use of a nonintrusive flow velocity measuring technique in the Langley 0.3 meter transonic cryogenic tunnel (TCT) were investigated. A laser velocimeter (LV) was used. It was concluded that free-stream velocity measurements can be successfully made in the Langley 0.3-m TCT using a low-power (15-mW) LV system. The measured and calculated mean velocities typically agreed within one percent. The overall normalized standard deviation was less than one percent. Tunnel vibration and temperature had no detrimental effects on the optical system. It is recommended that the LV work should be further investigated for future use in the Langley 0.3-m TCT.

Gartrell, L. R.↗

Positional characteristics of meter-decameter wavelength bursts associated with hard X-ray bursts

Isolated and grouped type III bursts have been observed in temporal association with impulsive hard X-ray bursts in the 26-154 keV range, down to frequencies as low as 30 MHz and out to a distance of 3.1 solar radii from the disk center. The bursts occurred in regions whose electron density may have been as much as 20 times higher than that of the Newkirk-Saito model. The present observations indicate that electron acceleration/injection occurs over a region covering a wide range of magnetic field lines. It is noted that, of the two gradual hard X-ray bursts observed in association with type IV bursts, one was accompanied by a type II event, while the other was not, although both exhibited the same characteristics. It is suggested that the gradual burst associated with a type IV only involved electrons which are trapped in the plasmoid which produces the meter-decameter emission, while another fraction of the population is trapped in the low-lying loops which produce the hard X-ray and centimeter radiation.

Kundu, M. R.↗

Metering Baffle for Turbine-Blade Cooling

Mixing losses due to excessive film cooling reduced. Turbine blade or vane cooled by gas or liquid flowing through holes to exterior airfoil surface. Metering baffle inside airfoil controls flow to each row of cooling holes. Resulting surface-film flow keeps airfoil cool enough to operate in high-heat, high pressure turbines.

Moore, R.↗

Transformer and Meter Tester

Numerically-controlled 5-axis machine tool uses transformer and meter to determine and indicate whether tool is in home position, but lacks built-in test mode to check them. Tester makes possible test, and repair of components at machine rather then replace them when operation seems suspect.

Stoms, R. M.↗

Characterization of particles in the Langley 0.3 meter transonic cryogenic tunnel using hot wire anemometry

Hot wire anemometry was used to identify the nature of particles reportedly observed during free stream velocity measurements in the Langley 0.3-meter transonic cryogenic tunnel using a Laser Doppler Velocimeter. Since the heat-transfer process from the hot wire depends on the thermal conductivity and sticking capability of the particles, it was anticipated that the hot wire anemometer response would be affected differently upon impaction by liquid droplets and solid aerosols in the test gas stream. Based on the measured time response of the hot-wire anemometer in the cryogenic tunnel operated in the 0.3-0.8 Mach number range, it is concluded that the particles impacting the hot wire are liquid in nature rather than solid aerosols. It is further surmised that the liquid aerosols are unevaporated liquid nitrogen droplets used for cooling the tunnel test gas.

Singh, J. J.↗

A rocket-borne electric field meter for the middle atmosphere

The design and construction of a rocket-borne electric field meter for determining the atmosphere's electric field and the conductivity in the middle atmosphere are considered. The operating characteristics of the instrument are discussed and a proposed flight configuration is given. The testing of the prototype is described and suggestions are advanced for further improvements.

Dettro, G. J.↗