Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Propeller-Design Problems of High-Speed Airplanes, Special Report

It is shown that on the basis of existing high-speed airfoil data, propeller efficiencies appreciably in excess of 40% do not appear possible at speeds above 500 miles per hour at 20,000 feet. The assumption that present propeller-blade thicknesses cannot be reduced radically, is implied. Until the reliability and applicability of the airfoil data are established, this conclusion must not be regarded as infallible. Dive tests with airplanes equipped with thrust meters and torque meters are proposed to provide an urgently needed check. The design of high-speed propellers is dictated wholly by compressibility considerations. The blade width, thickness, and pitch distribution; also the airfoil sections, the lift coefficient, the propeller diameter, and rpm must all be adjusted if reasonable efficiencies are to be maintained at airplane speeds that are now being approached. Research is urgently needed on: 1) airfoils at subsonic, sonic, and supersonic speeds; 2) propellers at high forward speeds in wind tunnels; 3)propellers in free flight at high speeds; and 4) jet propulsion and related devices. The breakdown of propeller efficiency indicated by airfoil data, should serve as an incentive for accelerated research on jet propulsion. This device may extend the attainable speed of current airplanes to the neighborhood of 550 miles per hour at 20,000 feet.

Dickinson, H. B.↗

Aerodynamic Models for the Low Density Supersonic Declerator (LDSD) Supersonic Flight Dynamics Test (SFDT)

An overview of pre-flight aerodynamic models for the Low Density Supersonic Decelerator (LDSD) Supersonic Flight Dynamics Test (SFDT) campaign is presented, with comparisons to reconstructed flight data and discussion of model updates. The SFDT campaign objective is to test Supersonic Inflatable Aerodynamic Decelerator (SIAD) and large supersonic parachute technologies at high altitude Earth conditions relevant to entry, descent, and landing (EDL) at Mars. Nominal SIAD test conditions are attained by lifting a test vehicle (TV) to 36 km altitude with a large helium balloon, then accelerating the TV to Mach 4 and and 53 km altitude with a solid rocket motor. The first flight test (SFDT-1) delivered a 6 meter diameter robotic mission class decelerator (SIAD-R) to several seconds of flight on June 28, 2014, and was successful in demonstrating the SFDT flight system concept and SIAD-R. The trajectory was off-nominal, however, lofting to over 8 km higher than predicted in flight simulations. Comparisons between reconstructed flight data and aerodynamic models show that SIAD-R aerodynamic performance was in good agreement with pre-flight predictions. Similar comparisons of powered ascent phase aerodynamics show that the pre-flight model overpredicted TV pitch stability, leading to underprediction of trajectory peak altitude. Comparisons between pre-flight aerodynamic models and reconstructed flight data are shown, and changes to aerodynamic models using improved fidelity and knowledge gained from SFDT-1 are discussed.

Van Norman, John W.↗

High-Frequency Density Oscillations from a Plasma Source Used for Simulating Low-Earth Orbit Plasma Environment

We present data from ground-based, vacuum-chamber tests demonstrating the ability to modulate the output of a plasma source capable of producing a low-Earth orbit (LEO) type plasma. We obtained plasma oscillations up to 2.5 kHz impingent on stationary test equipment, which corresponds to meter-level ionospheric structures in LEO. This plasma source is, therefore, suitable for developing scientific instruments that measure the LEO plasma environment, in situ, with meter-level spatial resolution. Measurements were made using a fixed-bias collector and an electrometer sampling at 40 kHz. A mechanical aperture was established at the output of the plasma source via two concentric grids. The outer grid was free to rotate in the azimuthal direction with respect to the fixed inner grid. An identical, alternating hole pattern in the two grids resulted in a variable aperture that cycles through 90 open/close cycles per revolution. The frequency of the plasma oscillations is limited by the mechanism used to spin the grids and the bearing assembly on which the grids rotate. Higher frequencies are obtainable by upgrading the drive mechanism, allowing the possibility of centimeter-level spatial resolution.

McTernan, Jesse K.↗

Front Range Wildland Fires: Evaluating the Efficacy of Remote Sensing Imagery in Monitoring Forest Fuels Treatment Methods

Over the last several decades, wildfire frequency and severity in forested areas along Colorado’s Front Range have increased due to a buildup of fuels. This has led to an increase in forest treatments, as well as an increased need to evaluate the success of these treatments. Remote sensing products offer an efficient and cost-effective way to monitor forest treatments; however, not all remote sensing products and analysis techniques have been explored by Coloradan land managers. Specifically, project partners at the Colorado State Forest Service (CSFS) and the Colorado Forest Restoration Institute (CFRI) were interested in using an effective and streamlined method of mapping canopy cover to better monitor forest treatment success. To support their needs, the NASA DEVELOP Front Range Wildland Fires team explored National Agricultural Imagery Program (NAIP) imagery at different spatial resolutions and numbers of training points with NASA’s Shuttle Radar Topography Mission (SRTM) Data Elevation Model (DEM) as a predictor in addition to NAIP imagery spectral predictors. From this analysis, we created classified canopy cover rasters, and compared accuracy metrics across model iterations. We also determined that the best performing model, with an overall accuracy of 0.900 uses 2021 NAIP imagery at 2-meter resolution, 800 training points, 200 testing points, does not use topographic predictors, and reclassifies shadow pixels via a pre-selected NDVI threshold.

Remote Sensing↗

Validation and Development of a Fast-Running CFD Model for the No-Vent Fill of Liquid Propellant Tank

Cryogenic fluids, while offering higher energy density than storable propellants, present several handling challenges, including gradual boil-off and tank self-pressurization. Transferring these propellants between tanks can be problematic, as the receiving tank's temperature and pressure often lead to flashing and rapid boil-off upon injection. The No-Vent Fill (NVF) technique mitigates these risks by preventing liquid fuel from being expelled overboard. By controlling tank pressure and ensuring appropriate condensation in the ullage region, the NVF process avoids exceeding vent pressure limits. In this study, Loci/STREAM-VOF simulations were compared with data from NASA K-site test runs on a 2.1 cubic meter tank with a bottom orifice under various no-vent fill conditions, including different wall temperatures, flow rates, and inlet liquid temperatures. The effort demonstrated that Loci/STREAM-VOF is capable of quantitatively capturing the important physics of NVF with submerged jets: (1) validation of the liquid-vapor interface turbulence velocity using previous experimental data showed good agreement at different fill levels; (2) validation of the CFD Stanton number for mass transfer provided an adequate mass transfer coefficient range; (3) consistent pressure agreements were found in the pressure history for both cold and warm conditions; and (4) the variations of final pressure with flow rate and inlet liquid temperature were well predicted by the CFD simulation. The application of NVF for low-gravity conditions will be studied in future work.

CFD↗

Validation and Development of a Fast-Running CFD Model for the No-Vent Fill of Liquid Propellant Tank

Cryogenic fluids, while offering higher energy density than storable propellants, present several handling challenges, including gradual boil-off and tank self-pressurization. Transferring these propellants between tanks can be problematic, as the receiving tank's temperature and pressure often lead to flashing and rapid boil-off upon injection. The No-Vent Fill (NVF) technique mitigates these risks by preventing liquid fuel from being expelled overboard. By controlling tank pressure and ensuring appropriate condensation in the ullage region, the NVF process avoids exceeding vent pressure limits. In this study, Loci/STREAM-VOF simulations were compared with data from NASA K-site test runs on a 2.1 cubic meter tank with a bottom orifice under various no-vent fill conditions, including different wall temperatures, flow rates, and inlet liquid temperatures. The effort demonstrated that Loci/STREAM-VOF is capable of quantitatively capturing the important physics of NVF with submerged jets: (1) validation of the liquid-vapor interface turbulence velocity using previous experimental data showed good agreement at different fill levels; (2) validation of the CFD Stanton number for mass transfer provided an adequate mass transfer coefficient range; (3) consistent pressure agreements were found in the pressure history for both cold and warm conditions; and (4) the variations of final pressure with flow rate and inlet liquid temperature were well predicted by the CFD simulation. The application of NVF for low-gravity conditions will be studied in future work.

CFD↗

Examination of a Standardized Test for Evaluating the Degree of Cure of EVA Encapsulation: Preprint

The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of the standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.

14 SOLAR ENERGY↗

Examination of a Standardized Test for Evaluating the Degree of Cure of EVA Encapsulation (Presentation)

The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of the standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.

14 SOLAR ENERGY↗

Toward large-scale building detection with convolutional neural network using remote sensing images

Establishing up-to-date nationwide building maps is essential to understand urban dynamics, such as estimating population and urban planning and many other applications. However, an efficient and effective solution is yet to be developed. In this paper, for the first time we evaluate three state-of-the-art CNNs for detecting buildings across entire United States using aerial images. The three CNN architectures, fully convolutional neural network, conditional random field as recurrent neural network, and SegNet, support semantic pixel-wise labeling and focus on capturing textural information at multi-scale. We use 1-meter resolution NAIP images as the test data set, and compare the detection results across the three methods. In addition, we propose to combine signed distance function labels with SegNet, which is the preferred CNN architecture identified by our extensive evaluations. The results are further improved in terms of precision, recall rate and the number of building detected. On average, model inference on test images is less than one minute for an area of size $\sim56$ $km^2$. With these promising results and the time required to process images, the framework offers great potential toward country scale building mapping with remote sensing imagery.

Yang, Lexie↗

Solar-Powered Air Stripping at the Rocky Flats Site, Colorado - 12361

The U.S. Department of Energy's Rocky Flats Site (the Site), near Denver, Colorado, is a former nuclear weapons facility that was constructed beginning in 1951. With the end of the Cold War, the Site was cleaned up and closed in 2005. Four gravity-driven groundwater treatment systems were installed during cleanup, and their continued operation was incorporated into the final remedy for the Site. All utilities, including electrical power, were removed as part of this closure, so all Site electrical power needs are now met with small solar-powered systems. The Mound Site Plume Treatment System (MSPTS) was installed in 1998 as an innovative system based on zero-valent iron (ZVI). Groundwater flow from the Mound source area containing elevated concentrations of volatile organic compounds (VOCs), primarily in the tetrachloroethene (PCE)-trichloroethene (TCE) family of chlorinated solvents, is intercepted by a collection trench and routed to twin ZVI treatment cells. Later, in 2005, remediation of VOC-contaminated soils at a second up-gradient source area included adding an electron donor to the backfill to help stimulate biodegradation. This reduced concentrations of primary constituents but caused down-gradient groundwater to contain elevated levels of recalcitrant degradation byproducts, particularly cis-1,2-dichloroethene and vinyl chloride. A gravel drain installed as part of the 2005 remediation directs contaminated groundwater from this second source area to the MSPTS for treatment. This additional contaminant load, coupled with correspondingly reduced residence time within the ZVI media due to the increased flow rate, resulted in reduced treatment effectiveness. Elevated concentrations of VOCs were then detected in MSPTS effluent, as well as in surface water at the downstream performance monitoring location for the MSPTS. Subsequent consultations with the Site regulators led to the decision to add a polishing component to reduce residual VOCs in MSPTS effluent. Initially, several alternatives such as commercial air strippers and cascade aerators were evaluated; resulting cost estimates exceeded $100,000. After several simpler alternatives were considered and prototype testing was conducted, the existing effluent metering manhole was converted to house a spray-nozzle based, solar-powered air stripper, at a cost of approximately $20,000. About two-thirds of this cost was for the solar power system, which was initially designed to only provide power for 12 hours per day. Performance data are being collected and adjustments made to optimize the design, determine maintenance requirements, and establish power needs for continuous operation. Analytical data confirm the air stripper is sharply reducing concentrations of residual contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2013 Caliban and Prospero experiments for the study of the behavior of radiation protection instrumentations in case of a criticality accident - 14346

Experiments using the CALIBAN and PROSPERO reactors were performed in 2013 in the framework of a collaboration between IRSN and CEA. The objective was to provide data about the possibility to use information given by radiation protection instrumentations (RPI) in the case of a criticality accident. In that purpose, the behavior of RPI was studied for various kinetics of the reactors which simulated different starts of a criticality accident. The article presents the safety issues associated with these experiments, i.e. the possible use of information given by the RPI for the emergency response of a criticality accident (detection of the accident, triage of the personnel, follow-up of the accident and reentry). Then, one paragraph is dedicated to the presentation of the tested material. In addition, the CALIBAN and PROSPERO reactors are briefly described, followed by the performed experiments. The RPI are neither designed nor dedicated to be used in case of a criticality accident. However, the preliminary conclusion of the experiments performed in 2013 is that the tested RPI have a correct behavior for slow kinetic experiments performed with the PROSPERO reactor, but might give less reliable and accurate information for pulse experiments performed with the CALIBAN reactor. In the last case, they can nevertheless provide information that can be helpful for the emergency response and the limitation of the consequences of the criticality accident. However, if the RPI are included in the emergency response of a criticality accident (detection, triage, follow-up, reentry), emergency procedures should be adapted. Other experiments might be performed in order to confirm results and to extend the number of tested materials, in particular portable survey meters or contamination area monitors. (authors)

42 ENGINEERING↗

Ground-based time-guidance algorithm for control of airplanes in a time-metered air traffic control environment: A piloted simulation study

The rapidly increasing costs of flight operations and the requirement for increased fuel conservation have made it necessary to develop more efficient ways to operate airplanes and to control air traffic for arrivals and departures to the terminal area. One concept of controlling arrival traffic through time metering has been jointly studied and evaluated by NASA and ONERA/CERT in piloted simulation tests. From time errors attained at checkpoints, airspeed and heading commands issued by air traffic control were computed by a time-guidance algorithm for the pilot to follow that would cause the airplane to cross a metering fix at a preassigned time. These tests resulted in the simulated airplane crossing a metering fix with a mean time error of 1.0 sec and a standard deviation of 16.7 sec when the time-metering algorithm was used. With mismodeled winds representing the unknown in wind-aloft forecasts and modeling form, the mean time error attained when crossing the metering fix was increased and the standard deviation remained approximately the same. The subject pilots reported that the airspeed and heading commands computed in the guidance concept were easy to follow and did not increase their work load above normal levels.

Knox, C. E.↗

Development of the 15-meter hoop-column antenna system

The development of the 15-meter hoop/column antenna system is presented. The 15-meter deployable structure is discussed along with the mulitple-beam feed system development and the structures and RF testing planned in 1985. The topics presented are: overview of antenna development activities; development of 15-meter reflector and kinematic deployment tests; preliminary modal survey test results and future structural dynamics tests; and radio frequency subsystems and near field testing.

Campbell, T. G.↗

Optical Testing of the James Webb Space Telescope

The James Webb Space Telescope (JWST) will be a large infrared telescope with a 6.5-meter primary mirror, working to a 2018 launch date. Ground testing for the JWST will occur in two test campaigns, at NASAs Goddard Space Flight Center and Johnson Space Center. The talk describes the JWST and its optical ground testing, highlighting the roles of many of the University of Rochester Institute of Optics' alumni as well as current faculty and students.

James Webb Telescope↗

Test and Analysis of an Inflatable Parabolic Dish Antenna

NASA is developing ultra-lightweight structures technology for large communication antennas for application to space missions. With these goals in mind, SRS Technologies has been funded by NASA Glenn Research Center (GRC) to undertake the development of a subscale ultra-thin membrane inflatable antenna for deep-space applications. One of the research goals is to develop approaches for prediction of the radio frequency and structural characteristics of inflatable and rigidizable membrane antenna structures. GRC has teamed with NASA Langley Research Center (LaRC) to evaluate inflatable and rigidizable antenna concepts for potential space missions. GRC has completed tests to evaluate RF performance, while LaRC completed structural tests and analysis to evaluate the static shape and structural dynamic responses of a laboratory model of a 0.3 meter antenna. This paper presents the details of the tests and analysis completed to evaluate the radio frequency and structural characteristics of the antenna.

Gaspar, james L.↗

Data Release Report Source Physics Experiments 5 and 6 (SPE-5 and SPE-6), Nevada National Security Site

The fifth Source Physics Experiment test (SPE-5) was conducted in Nevada on April 26, 2016, at 20:49:00 Coordinated Universal Time (UTC). The explosive source was 4,288.7 kilograms (kg) of polymer-bonded explosive (PBXN) –110, equivalent to 5,035 kg of trinitrotoluene (TNT) detonated at a depth of 76.5 meters (m). The sixth Source Physics Experiment test (SPE-6) was conducted in Nevada on October 12, 2016 at 18:36:00 UTC. The explosive source was 1,982.2 kg of PBXC-141, equivalent to 2,240.2 kg of TNT detonated at the depth of 31.4 m. Both tests were recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers installed at various depths ranging from 4 to 99 m below ground surface in boreholes positioned around the shot, and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and three-component accelerometers at distances of 100 m to 400 kilometers. In addition, both explosions were recorded in a temporary array of 996 geophones arranged in a densely spaced grid pattern (“large N”). This report coincides with the release of these data for analysts and organizations that are not participants in this program. This report describes the fifth and sixth Source Physics Experiment tests and the various types of near-field and far-field data that are available.

58 GEOSCIENCES↗

Wind-tunnel investigation of an externally blown flap STOL transport model including and investigation of wall effects

A wind-tunnel investigation was conducted in the Langley V/STOL tunnel and in a scaled version of the Ames 40- by 80-foot tunnel test section installed as a liner in the Langley V/STOL tunnel to determine the effect of test-section size on aerodynamic characteristics of the model. The model investigated was a swept-wing, jet-powered, externally blown flap (EBF) STOL transport configuration with a leading-edge slat and triple-slotted flaps. The model was an 0.1645-scale model of a 11.58-meter (38.0-ft) span model designed for tests in a 40- by 80-foot tunnel. The data compare the aerodynamic characteristics of the model with and without the tunnel liner installed. Data are presented as a function of thrust coefficient over an angle-of-attack range of 0 deg to 25 deg. A thrust-coefficient range up to approximately 4.0 was simulated, most ot the tests being conducted at a free-stream dynamic pressure of 814 Newtons/sq m (17 lb sq ft). The data are presented with a minimum of analysis.

Gentry, G. L., Jr.↗

Wind tunnel tests on a one-foot diameter SR-7L propfan model

Wind tunnel tests have been conducted on a one-foot diameter model of the SR-7L propfan in the Langley 16-Foot and 4 x 7 Meter Wind Tunnels as part of the Propfan Test Assessment (PTA) Program. The model propfan was sized to be used on a 1/9-scale model of the PTA testbed aircraft. The model propeller was tested in isolation and wing-mounted on the aircraft configuration at various Mach numbers and blade pitch angles. Agreement between data obtained from these tests and data from Hamilton Standard validate that the 1/9-scale propeller accurately simulates the aerodynamics of the SR-7L propfan. Predictions from an analytical computer program are presented and show good agreement with the experimental data.

Aljabri, Abdullah S.↗