Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Multiplexable intrinsic Fabry–Perot interferometric fiber sensors for multipoint hydrogen gas monitoring

This Letter presents an approach to produce multiplexable optical fiber chemical sensor using an intrinsic Fabry–Perot interferometer (IFPI) array via the femtosecond laser direct writing technique. Using the hydrogen-sensitive palladium (Pd) alloy as a functional sensory material, Pd alloy coated IFPI devices can reproducibly and reversibly measure hydrogen concentrations with a detection limit of 0.25% at room temperature. Seven IFPI sensors were fabricated in one fiber and performed simultaneous temperature and hydrogen measurements at seven different locations. This Letter demonstrates a simple yet effective approach to fabricate multiplexable fiber optical chemical sensors for use in harsh environments.

Cao, Rongtao↗

Molecularly Imprinted Polymer Sensor Empowered by Bound States in the Continuum for Selective Trace-Detection of TGF-beta

The integration of advanced materials and photonic nanostructures can lead to enhanced biodetection capabilities, crucial in clinical scenarios and point-of-care diagnostics, where simplified strategies are essential. Herein, a molecularly imprinted polymer (MIP) photonic nanostructure is demonstrated, which selectively binding to transforming growth factor-beta (TGF-β), in which the sensing transduction is enhanced by bound states in the continuum (BICs). The MIP operating as a synthetic antibody matrix and coupled with BIC resonance, enhances the optical response to TGF-β at imprinted sites, leading to an augmented detection capability, thoroughly evaluated through spectral shift and optical lever analogue readout. The validation underscores the MIP-BIC sensor capability to detect TGF-β in spiked saliva, achieving a limit of detection of 10 fM and a resolution of 0.5 pM at physiological concentrations, with a precision of two orders of magnitude above discrimination threshold in patients. The MIP tailored selectivity is highlighted by an imprinting factor of 52, showcasing the sensor resistance to interference from other analytes. The MIP-BIC sensor architecture streamlines the detection process eliminating the need for complex sandwich immunoassays and demonstrates the potential for high-precision quantification. This positions the system as a robust tool for biomarker detection, especially in real-world diagnostic scenarios.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

(Paper) TRIPWIRE: Multi-modal Distributed Sensing For Repository Verification

Underground geological repositories for storing used nuclear fuel are being planned and developed around the world. Research is being performed to understand technical aspects of sealing entombed materials and underground repositories to ensure the radiological and nuclear materials remain contained. To support safeguards verification for these facilities research at Idaho National Laboratory (INL) is underway to develop and demonstrate a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. Tamper-indicating self-diagnostic assessments will be done using optical and electronic time domain reflectometry in the SFBs and PCCs, respectively. The result will be a long, kilometer-scale multi-modal SFB-PCC system. Simulation and modeling are being used to inform the work and a demonstration of the system's utility is planned at a nuclear storage facility in the future.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Data-driven acoustic measurement of moisture content in flowing biomass

Measuring the moisture content in flowing biomass is critical to processes such as liquid biofuel conversion, such as biogasoline, biodiesel, bio jet kerosene, etc. However, biomass tends to flow in aggregates, which results in significant inhomogeneities in the amount of biomass flowing in front of a sensor at a given time, and there can be significant overlap in the material properties of dry vs wet biomass, leading to poor signal-to-noise ratio. We present a technique for identifying biomass moisture content using a series of acoustic pitch-catch measurements to quantify the sound speed and acoustic amplitude through the biomass, in conjunction with classical machine learning techniques, including Naive Bayes, Random Forest, and K-Nearest Neighbors classification. We amplify the differences between the acoustic measurements in different moisture levels by collecting a series of pulse-echo measurements, which we sort in order of ascending sound speed. We test the accuracy of the technique on experimentally-prepared batches of corn stover biomass with specified moisture levels and measure the average error in the estimated moisture level as a function of the number of pitch-catch measurements used. We observe average estimation errors as low as 6.7% by increasing the number of measurements and optimizing the hyperparameters. This work presents a novel method determining moisture content in flowing biomass with inhomogeneous flow. Additionally, this technique has application in optimizing biomass conversion processes, as well as other fields including, paper production, natural fiber processing, and mineral extraction.

09 BIOMASS FUELS↗

Templating Functional Materials Using Self-Assembled Block Copolymer Thin-Film for Nanodevices

The nanomorphologies and nanoarchitectures that can be synthesized using block copolymer (BCP) thin-film self-assembly have inspired a variety of new applications, which offer various advantages, such as, small device footprint, low operational power and enhanced device performance. Imperative for these applications, however, is the ability to transform these small polymeric patterns into useful inorganic structures. BCP-templated inorganic nanostructures have shown the potential for use as active materials in various electronic device applications, including, field-effect transistors, photodetectors, gas sensors and many more. This article reviews various strategies that have been implemented in the past decade to fabricate devices at nanoscale using block copolymer thin films.

Subramanian, Ashwanth↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves the resistance measurement of a thin film of niobium. During coating, the change in resistance reflects the conversion of the film to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the thickness, allowing for increased precision in future depositions.

Howard, K. [Unlisted] (ORCID:0000000325613308)↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves a four-point resistance measurement of a thin film of niobium, inside the coating region. During coating, the change in resistance reflects the conversion of the film from Nb to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the Nb3Sn film thickness, allowing for increased precision in future depositions for cavity applications.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Sensor Placement Optimization Study for the Built Environment: Operational Use Cases

Systems of fixed-position radiation sensors can provide information that assists emergency responders following nuclear and radiological incidents. State, local, tribal, and territorial (SLTT) government agencies that implement systems of fixed-position sensors are faced with numerous decisions regarding sensor selection, quantity, and placement. To develop guidance on implementation of radiation detection systems, we simulated the release of radioactive material in an urban environment using a combination of three models: the Weather Research Forecasting (WRF), Quick Urban and Industrial Complex (QUIC), and Monte Carlo N-Particle (MCNP) models. We then evaluated the performance of several hypothetical sensor systems. The small number of simulations we conducted are not sufficient to generate definitive design guidance for radiation sensor systems, but we did identify trends that would be of interest to emergency planners. For a scenario that releases 1000 curies of Cs-137, radiation detectors were needed at 500-meter intervals to have a high likelihood of event detection and to estimate source location and plume detection. We also noted that optimal detector altitude varied with distance to the source. We recommend additional research in this area be conducted to support developing sensor placement guidelines that expand on a range of locations, isotopes, activity levels, and different weather conditions. Original simulation strategies included a range of environments, additional radioisotopes (Am241 and AmBe), and a larger selection of sensor types. These types of expansions would support SLTT guidance on sensor system recommendations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Functional stimuli-responsive polymers on micro- and nano-patterned interfaces

Micro- and nano-patterned surfaces offer precise control over morphology and chemical composition, enhancing the stability, durability, and functionality of coating materials. When combined with stimuli-responsive polymers, these surfaces gain dynamic adaptability, enabling reversible binding, reusable sensing, and selective molecular capture. Furthermore, while recent review articles have explored various aspects of stimuli-responsive materials, from hydrogel patterns for bioanalytical applications to shape-morphing hydrogels for soft robotics and sensors, a comprehensive review focused on the integration of smart polymers with micro- or nano-patterned interfaces remains absent. This review addresses key surface patterning techniques, including soft lithography, colloidal lithography, and polymer brush photolithography, as well as advances in surface-initiated polymerization methods, such as surface-initiated controlled radical polymerization (SI-CRP). In addition, we discuss recent progress in integrating stimuli-responsive polymers with patterned surfaces to create advanced, functional materials.

Colloidal lithography↗

Effects of blended cements and carbonation on chloride-induced corrosion propagation

Highlights: • Corrosion propagation of blended cements was investigated for 1 year. • Carbonated and non‑carbonated mortars were evaluated. • Galvanostatic pulse and ER sensors were used to monitor corrosion. • Mortar properties were correlated with corrosion rates and corrosion damage. • Relationships between mortar properties and corrosion behaviour were established. Supplementary cementitious materials are known to refine the pore structure of concrete and accelerate the carbonation progress. The combination of the two processes can have both beneficial and disadvantageous effects on corrosion, especially when chlorides are also involved. In this study the corrosion properties of multiple blended cements were evaluated in carbonated and non‑carbonated states, with chlorides introduced through cyclic ponding. The examination involved monitoring the propagation phase, determining the microstructural properties of cements, and assessing the final corrosion damage. The results showed that the steel in the blended cements initially had a relatively high corrosion activity, which later decreased compared to the OPC. This stabilisation was presumably due to the beneficial changes to the pore structure. Carbonation had a significant impact on the corrosion, with carbonated mortars revealing shallower damage over a larger surface area. This effect was more pronounced for blended cements that exhibited greater susceptibility to carbonation.

36 MATERIALS SCIENCE↗

Assessment of Flow-Enhanced Sensors for Actinide Quantification in MSRs

This report serves as the deliverable for Milestone M2RS-22AN0401062 that is part of Work Package RS-22AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone is to assess the capabilities of flow-enhanced electrochemical sensors (FEES) to quantify actinides in molten salt reactors. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits in order to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. To support this work, Argonne constructed a molten salt flow system to serve as a testbed for the development of safeguards and process monitoring-relevant sensors in challenging molten salt flow conditions. Through extensive flow testing using UCl3-bearing salts, Argonne has been able to show that the FEES are able to make good measurements of salt composition. Concentration measurements with a mean absolute error of 0.09 wt% have been achieved for representative fuel salt mixtures across a range of UCl3 loadings. Repeatability was also good, with the relative standard deviation from repeated measurements being less than 1.0%. These sensors have also been shown to be able to measure the flow rate of the salt within the flow system’s transfer line. Although the accuracy of the sensors has been good, the sensors have thus far not been able to achieve performance good enough to satisfy the nuclear material accountancy requirements in 10 CFR 74. To do so, accuracy levels of 0.1% must be achieved; the FEES when operated in Argonne’s flow system have so far only been able to achieve relative errors of approximately 5.0%. Much of the error that has been observed at this stage is due to challenges in maintaining a stable salt composition in the molten salt flow system, and it is not believed that there are any inherent flaws in the sensor design. Nonetheless, the high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will likely be needed to push the measurement accuracy to the needed level.

Moore, Colin E.↗

Use of Sensors and Machine Learning for Signal Discovery in a Solvent Extraction Process – 23280

Reprocessing is an important step in the nuclear fuel cycle where usable nuclear materials are extracted from spent fuel for recycling. The extraction of materials for reuse simultaneously reduces not only the volume of nuclear waste, but its decay time to radioactivity levels similar to that of the originating uranium ore. As part of an initiative to steward research, development, and innovation into the nuclear fuel cycle, Idaho National Laboratory is designing and constructing a solvent extraction testbed named Beartooth. Beartooth will allow researchers to refine extraction processes, test innovative extraction processes, and give early career scientists opportunities to gain skills in performing separations chemistry that uses centrifugal contactors. In addition, the Beartooth testbed is being uniquely designed to enable novel technologies including machine learning capabilities for the characterization of chemical process operations in near real-time. To aid in the design of Beartooth, a team of researchers are installing a variety of atypical sensors into a system of contactors for signal discovery. The team will implement machine learning methods on sensor data to determine signal features with the goal of providing a process operator with a deeper understanding of the chemical process and equipment usage. This work will summarize sensors utilized and preliminary results from an infrared camera.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High speed ultraviolet digital image correlation (UV-DIC) for dynamic strains at extreme temperatures

Digital Image Correlation (DIC) is a camera-based method of measuring full-field displacements and strains from the surface of a deforming object. It can be applied at any length scale (determined by the lenses) and any time scale (determined by the camera), and because it is non-contacting, it can also be used at temperatures much higher than can be withstood by bonded strain gauges. At extreme temperatures, materials emit light in the form of blackbody radiation, which can saturate the camera sensor. It has previously been shown that the emitted light can be effectively screened by using ultraviolet (UV) cameras, lenses, and filters; however, commercially available UV cameras are relatively slow, which limits the speed of combined UV-DIC measurements. In this study, a UV intensifier was paired with a high-speed camera, and its ability to perform UV-DIC at high temperature and high speed was investigated. The system was compared over three different experiments: (A) a quasi-static thermal expansion test at high temperature, (B) a vibration test at room temperature, and (C) the same vibration test repeated at high temperature. The system successfully performed DIC up to at least 1600 °C at frame rates of 5000 fps, which is more than 100 times faster than other examples of UV-DIC in the literature. In all cases, measurements made using the UV intensifier were much noisier than those made without the intensifier, but the intensifier enabled measurements at temperatures well above those which an unfiltered high-speed camera otherwise saturates.

47 OTHER INSTRUMENTATION↗

Systematic Characterization on Optical and Phonon Properties of Cs[Pb x Sn 1– x ]I 3 Alloyed Perovskites via First-Principles Modeling

Here, understanding the optical properties and phonon thermodynamic features of materials enables the determination of their viability for optoelectronic applications including optical-based gas sensors. Metal halide perovskites ABX 3 as well as their mixed alloys can be attractive in applications of this kind. In particular, the formation of alloyed perovskites A[B x B’ 1–x ]X 3 modulates the functional characteristics that can overtake the single-halide ABX 3 . To this end, we use the first-principles simulations to model the effect of B-site alloying on the optical and phonon properties of cubic Cs[Pb x Sn 1–x ]I 3 (x = 0.75, 0.50, and 0.25). We identified the systematic shifts of optical properties as a function of alloying concentration, such as dielectric constants, refraction indices, and absorption coefficients. It was also found that a linear correlation exists between the optical constants and the band gaps of these materials, which satisfies the Penn model. Modeling of phonons in Cs[Pb x Sn 1–x ]I 3 showed that dissipating the dynamically unstable phonons can be feasible at a carefully chosen alloying concentration, which are originally present in their single-halide Pb- and Sn-ends. Our findings pave a way to optimize the alloying conditions of the alloyed perovskite systems of interest for tuning their optical and phonon stability characteristics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Embedding of Fiber Optic Sensors in Stainless Steel for Sensing in Harsh Environments

Structural health monitoring is critical for components working in harsh environments to assess their safety and integrity. This can be realized with advanced sensors, such as fiber optic sensors, embedded in these components. Recent studies have used ultrasonic consolidation (UC) and laser-based additive manufacturing (AM) techniques to embed fiber optic sensors in metals. However, sensor embedding using these techniques has been challenging, with gaps and voids around the embedded fiber. Successful embedding of fiber optic sensors requires good contact between the fiber and the matrix to eliminate potential gas/liquid leaks in critical systems such as in nuclear and aerospace services. Defect-free fiber/matrix bond is also essential for accurate measurement of parameters of interest, such as temperature and strain. This study developed a novel fiber embedding technique based on electric field-assisted sintering (EFAS). Sapphire optical fibers with diameters of 125 µm and 250 µm were embedded in stainless steel (SS) 316L using EFAS. The embedding was completed by sintering SS 316L powders at a pressure of 50MPa, hold time of 5 min, and temperatures of 1000°C, 1100°C, and 1200°C. Joule heating mechanism during EFAS enabled rapid sintering of the SS 316L powder with resulting sample densities over 99%. Microscopy analysis performed on the cross-sections revealed a defect-free bond between the embedded fiber and SS 316L. The good integrity of the embedded fiber was evidenced by optical transmittance measurement. Optical attenuation of the fiber before and after embedment was examined in the near-infrared region. Scanning electron microscopy was employed to investigate the grain morphology of SS 316L near the embedded fiber. Hardness distribution in the sintered part was also investigated to study the effect of the embedded fiber on the mechanical properties of the as-fabricated component. The results indicated that EFAS was able to embed fiber in SS with good fiber functionality and part quality.

36 - MATERIALS SCIENCE↗

Atomistic measurement and modeling of intrinsic fracture toughness of two-dimensional materials

Quantifying the intrinsic mechanical properties of two-dimensional (2D) materials is essential to predict the long-term reliability of materials and systems in emerging applications ranging from energy to health to next-generation sensors and electronics. Currently, measurements of fracture toughness and identification of associated atomistic mechanisms remain challenging. Herein, we report an integrated experimental–computational framework in which in-situ high-resolution transmission electron microscopy (HRTEM) measurements of the intrinsic fracture energy of monolayer MoS 2 and MoSe 2 are in good agreement with atomistic model predictions based on an accurately parameterized interatomic potential. Changes in crystalline structures at the crack tip and crack edges, as observed in in-situ HRTEM crack extension tests, are properly predicted. Such a good agreement is the result of including large deformation pathways and phase transitions in the parameterization of the inter-atomic potential. The established framework emerges as a robust approach to determine the predictive capabilities of molecular dynamics models employed in the screening of 2D materials, in the spirit of the materials genome initiative. Moreover, it enables device-level predictions with superior accuracy (e.g., fatigue lifetime predictions of electro- and opto-electronic nanodevices).

Zhang, Xu↗