Intracycle RPM control for vertical axis wind turbines

The wind energy market is currently dominated by horizontal axis wind turbines (HAWTs); however, vertical axis wind turbines (VAWTs) are emerging as a design alternative, especially for deep-water offshore siting due to their low center of gravity, ease of access to drivetrain components, and overall simplicity. Due to the absence of a pitch mechanism in large-scale Darrieus VAWTs, stall control has often been used to manage power and loads. Introducing a pitching mechanism in H-type VAWTs has been studied, but this diminishes the mechanical simplicity advantage, and the use of a pitching mechanism in a large-scale Darrieus-type VAWT is not practical. This work examines an innovative, alternative method to control the rotor dynamics of a large-scale 5 MW VAWT to maximize power while constraining loads without introducing any new or complex mechanical elements. This control strategy is termed intracycle revolution per minute (RPM) control, where the rotational speed of the turbine is allowed to vary in an optimal fashion with the azimuthal location of blades as opposed to typical constant RPM operation. An optimization framework is formulated for an open-loop optimal control problem and solved to maximize power subject to constraints on aerodynamic design loads. Results are presented to demonstrate the benefits and the performance limits of intracycle RPM control for large-scale 5 MW Darrieus VAWTs, namely, (1) power production (quantified in terms of AEP) that can be increased subject to baseline load limits and (2) opportunities to significantly increase AEP or decrease loads via intracycle RPM control that are examined for both two-bladed and three-bladed VAWTs.

17 WIND ENERGY↗

Load Disaggregation (Modeling Individual Appliance Power Generation & Consumption in Real-Time)

We developed a machine learning-based load disaggregation method to estimate the real-time output of individual appliances from the whole-house measurements. We first learn the important features associated with each type of appliances using the ground truth consumption data of individual appliances potentially available for a small set of houses equipped with submeters. The learned features are then be used to estimate the power generation/consumption of the appliances from the whole-house consumption. This developed load disaggregation software includes two steps. The first step is to identify the on/off status of different appliances using a classification method, and the second step is to estimate the appliance output using a regression method.

Hao, Jun↗

High Powered Tests of Dielectric Loaded High Pressure RF Cavities for Use in Muon Cooling Channels

Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. Alumina of purities ranging from 96 to 99.8% was tested in a high pressure RF test cell at the MuCool Test Area at Fermilab. The results of breakdown studies with pure nitrogen gas, and oxygen-doped nitrogen gas indicate the peak surface electric field on the alumina ranges between 10 and 15 MV/m. How these results affect the design of a prototype cooling channel cavity will be discussed.

43 PARTICLE ACCELERATORS↗

Advanced Light-Duty Spark Ignition Engine Research: Co-Optimization of Fuels and Engines and Partnership to Advance Combustion Engines (FY2020 Annual Progress Report)

This report covers recent progress on research tasks that support both the Co-Optimization of Fuels and Engines (Co-Optima) initiative and the Partnership to Advance Combustion Engines (PACE) consortium. The Co-Optima tasks further the science-base needed by industry stakeholders to co-evolve the next generation of highly efficient direct injection spark ignition (DISI) engines and new gasoline-type fuels. The research emphasis is on fuel effects on multimode spark ignition (SI) engine operation, which uses traditional non-dilute stoichiometric operation for peak load and power but reverts to lean operation at lower loads to provide higher fuel economy. This work focuses on determining desirable fuel specifications in terms of well-established metrics like research octane number (RON) and motor octane number, but it also involves the assessment of new fuel metrics, including fuel sooting propensity and phi-sensitivity. The PACE task supports the development of predictive computational fluid dynamics (CFD) modeling, which promises to unlock new strategies for high-efficiency combustion while minimizing tailpipe emissions. Here, the primary fuel is a regular E10 gasoline (i.e., a regular gasoline blend containing 10% ethanol), and focus is on fuel-spray dynamics and soot emissions. Soot-formation pathways are studied to determine how the pathways change with injection strategies and the thermal state of the engine (i.e., cold-starting vs. fully warmed-up operation). This PACE task also contributed to the development of an optimal E10 gasoline surrogate fuel, as reported in detail elsewhere

33 ADVANCED PROPULSION SYSTEMS↗

Low-power ring counter drives high-level loads

Ring counter dissipates very low power in standby conditions, yet drives high-current loads on a low duty-factor basis. Complementary transistors are used so that in one selected stage both transistors are conducting while the transistors of the other stage are cut off.

Source record↗

Wind and structural loads data measured on parabolic trough solar collectors at an operational power plant

Abstract Wind loading is a primary contributor to structural design costs of concentrating solar-thermal power collectors, such as heliostats and parabolic troughs. These structures must resist the mechanical forces generated by turbulent wind, while the reflector surfaces must maintain optimal optical performance. Studying wind-driven loads at a full-scale, operational concentrating solar-thermal power plant provides insights into the wind impact on the solar collector field beyond the capabilities of wind tunnel tests or state-of-the-art simulations. We conducted comprehensive field measurements of the atmospheric turbulent wind conditions and the resulting structural wind loads on parabolic troughs at the Nevada Solar One plant over a two-year period. The measurement setup included meteorological masts and structural load sensors on four trough rows. Additionally, a lidar scanned the horizontal plane above the trough field. In this study, we describe the high-resolution dataset characterizing the complex flow field and resulting structural loads. This first-of-its-kind dataset will enhance the understanding of wind loading on collector structures and will help in designing the next-generation solar collectors and photovoltaic trackers.

14 SOLAR ENERGY↗

Thermal Management and Power Packaging for Spacecraft of the Next Millennium

Power Distribution; Cabling, fault protection and switches to turn power on/off to spacecraft loads; Isolate loads from bus noise and regulate power to load against disturbances from the load and the bus; Protect the power distribution system from load failures.

X2000 Thermal management Power Packaging Next Mill↗

The Evaluation of the Heat Loading from Steady, Transient, and Off-Normal Conditions in ARIES Power Plants

The heat loading on plasma facing components (PFCs) provides a critical limitation for design and operation of the first wall, divertor, and other special components. Power plants will have high power entering the scrape-off layer and transporting to the first wall and divertor. Although the design for steady heat loads is understood, the approach for transient and offnormal loading is not. The characterization of heat loads developed for ITER1 can be applied to power plants to better develop the operating space of viable solutions and point to research focus areas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sizing Considerations for EV Dynamic Wireless Charging Systems with Integrated Energy Storage

Roadways with dynamic wireless charging systems (DWCS) enable charge-sustaining in-motion EV charging, which can reduce charging idle time while increasing range capabilities. Spatially distributed transmitter coils are controlled in response to traffic load that varies significantly minute to minute with high power levels, very short charging time, and low system utilization like wind turbine power. Traffic load estimation and localized analysis may guide effective sizing and topology adoption for feasible and scalable DWCS deployment. DWCS traffic load approximation is reviewed with measured Automated Traffic Recorder (ATR) data and statistical distributions being used to create a synthetic load analyzed using proposed metrics quantifying system utilization over time. Lumped coil section segmentation is compared between second-based distance and spatial density analysis methods, offering 17-27% greater system utilization. A peak load shifting method is proposed for traffic redirection across two tracks with optional BESS integration increasing system utilization by 50-60% depending on time-based and power reserve-based sizing and control.

Lewis, Donovin D.↗

Convex Relaxations of Maximal Load Delivery for Multi-Contingency Analysis of Joint Electric Power and Natural Gas Transmission Networks

Recent increases in gas-fired power generation have engendered increased interdependencies between natural gas and power transmission systems. These interdependencies have amplified existing vulnerabilities in gas and power grids, where disruptions can require the curtailment of load in one or both systems. Although typically operated independently, coordination of these systems during severe disruptions can allow for targeted delivery to lifeline services, including gas delivery for residential heating and power delivery for critical facilities. To address the challenge of estimating maximum joint network capacities under such disruptions, we consider the task of determining feasible steady-state operating points for severely damaged systems while ensuring the maximal delivery of gas and power loads simultaneously, represented mathematically as the nonconvex joint Maximal Load Delivery (MLD) problem. To increase its tractability, we present a mixed-integer convex relaxation of the MLD problem. Then, to demonstrate the relaxation’s effectiveness in determining bounds on network capacities, exact and relaxed MLD formulations are compared across various multi-contingency scenarios on nine joint networks ranging in size from 25 to 1191 nodes. The relaxation-based methodology is observed to accurately and efficiently estimate the impacts of severe joint network disruptions, often converging to the relaxed MLD problem’s globally optimal solution within ten seconds.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗