Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A Conceptual Framework to Describe Energy Efficiency and Demand Response Interactions

Energy efficiency (EE) and demand response (DR) resources provide important utility systems and ratepayer benefits. At the same time, the rapid change in the amount and type of variable renewable energy, like solar and wind, is reshaping the role and economic value of EE and DR, and will likely affect the time-dependent valuation of EE and DR measures. Utilities are increasingly interested in integrating EE and DR measures as a strategic approach to improve their collective cost-effectiveness and performance. We develop a framework to identify the EE and DR attributes, system conditions, and technological factors that are likely to drive interactions between EE and DR. We apply the framework to example measures with different technology specifics in the context of different utility system conditions. We find that EE and DR interactions are likely driven by changes in discretionary load, the addition of controls or other capabilities to shift loads, and the coincidence of savings with system peak or load building periods. Our analysis suggests increasing complexity in evaluating EE and DR interactions when moving from standalone equipment to integrated systems. The framework can be applied to research on integrated building systems by grouping measures into portfolios with different likely implications for EE and DR interactions.

Satchwell, Andrew J. (ORCID:0000000244053599)↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

Effect of nickel on the kinematic stability of retained austenite in carburized bearing steels – In-situ neutron diffraction and crystal plasticity modeling of uniaxial tension tests in AISI 8620, 4320 and 3310 steels

The presence of kinematically metastable retained austenite in the microstructure of bearing components can significantly affect the macro and micro-mechanical material response. In the present work, the influence of Ni on the stability of the retained austenite within three different grades of high carbon bearing steel using in-situ neutron diffraction is investigated. For the first time, the results show that presence of Ni increases the stability of the austenite in the elastic regime whereas the transformation rate remains unaffected. Crystal plasticity finite element (CPFE) modeling was used to study the deformation in these three steels and shows that the predominant factor causing the difference in mechanical behavior of these steels is the austenite stability. Finally, the elastic and plastic response of the matrix martensite was found to be identical among all specimens while the austenite demonstrates similar elastic behavior but remarkably different stabilities under monotonic loading.

36 MATERIALS SCIENCE↗

Concerted Proton–Electron Transfer Minimizes Substituent Effects on Adsorbed Phthalocyanine Electrocatalysis

Molecularly modified electrodes (MMEs) are potent electrocatalysts, but few principles exist for their rational design. Electrocatalysis by soluble molecules depends strongly on substituents that tune the catalyst redox potential (E 1/2 ), but it is unclear if this parameter similarly impacts MME catalysis. Herein, we employ the hydrogen evolution reaction (HER) as a test case for comparing carbon-adsorbed cobalt phthalocyanine (CoPc/C) and cobalt hexadecafluoro-phthalocyanine (CoFPc/C). By correlating HER activity and voltammetric data to total Co surface concentration across a wide range of catalyst loadings, we find that only 5–25% of adsorbed Co sites contribute to the Co(II/I) redox wave and that this subpopulation poorly correlates with catalytic activity. Instead, in the low-loading limit, catalytic activity correlates linearly with the majority Co(II/I)-silent Co population, revealing per-site turnover frequency (TOF) values for HER. Despite a 230 mV difference in Co(II/I) redox potentials, CoPc/C and CoFPc/C display TOF values differing by less than a factor of 3 when compared over a wide potential range. Mechanistic studies point to an inner-sphere concerted proton–electron transfer step as rate-determining, suggesting that the Co–H bond dissociation free energy (BDFE) rather than the Co(II/I) E 1/2 is thermodynamically relevant. Computational studies indicate that the fluoro-substituents lead to compensatory changes in Co(II/I) E 1/2 and Co(I) basicity, leaving the Co–H BDFE largely unchanged between CoPc and CoFPc and thereby manifesting in similar catalytic rates. Furthermore, these results highlight the limited effect of E 1/2 -tuning on MME catalytic activity and motivate the development of methods to directly alter active site–substrate BDFE.

Catalysts↗

FPDeep: Scalable Acceleration of CNN Training on Deeply-Pipelined FPGA Clusters

In this paper, we propose a framework called FPDeep, which uses a hybrid of model and layer paral- lelism to configure distributed reconfigurable clusters to train DNNs. This approach has numerous benefits. First, the design does not suffer from batch size growth. Second, novel workload and weight partitioning leads to balanced loads of both among nodes. And third, the entire system is fine-grained pipeline. This leads to high parallelism and utilization and also minimizes the time features need to be cached while waiting for back-propagation.

Wang, Tianqi↗

Modeling suggests SARS-CoV-2 rebound after nirmatrelvir-ritonavir treatment is driven by target cell preservation coupled with incomplete viral clearance

In a subset of SARS-CoV-2-infected individuals treated with the antiviral nirmatrelvir-ritonavir, the virus rebounds following treatment. The mechanisms driving this rebound are not well understood. We used a mathematical model to describe the longitudinal viral load dynamics of 51 individuals treated with nirmatrelvir-ritonavir, 20 of whom rebounded. Target cell preservation, either by a robust innate immune response or initiation of N-R near the time of symptom onset, coupled with incomplete viral clearance, appears to be the main factor leading to viral rebound. Moreover, the occurrence of viral rebound is likely influenced by the time of treatment initiation relative to the progression of the infection, with earlier treatments leading to a higher chance of rebound. A comparison with an untreated cohort suggests that early treatments with nirmatrelvir-ritonavir may be associated with a delay in the onset of an adaptive immune response. Nevertheless, our model demonstrates that extending the course of nirmatrelvir-ritonavir treatment to a 10-day regimen may greatly diminish the chance of rebound in people with mild-to-moderate COVID-19 and who are at high risk of progression to severe disease. Altogether, our results suggest that in some individuals, a standard 5-day course of nirmatrelvir-ritonavir starting around the time of symptom onset may not completely eliminate the virus. Thus, after treatment ends, the virus can rebound if an effective adaptive immune response has not fully developed. These findings on the role of target cell preservation and incomplete viral clearance also offer a possible explanation for viral rebounds following other antiviral treatments for SARS-CoV-2.

60 APPLIED LIFE SCIENCES↗

Critical problems of energy frontier Muon Colliders: optics, magnets and radiation

This White Paper brings together our previous studies on a Muon Collider (MC) and presents a design concept of the 6 TeV MC optics, the superconducting (SC) magnets, and a preliminary analysis of the protection system to reduce magnet radiation loads as well as particle backgrounds in the detector. The SC magnets and detector protection considerations impose strict limitations on the lattice choice, hence the design of the collider optics, magnets and Machine Detector Interface (MDI) are closely intertwined. As a first approximation we use the Interaction Region (IR) design with beta-star=3 mm, whereas for the arcs we re-scale the arc cell design of the 3 TeV MC. Traditional cos-theta coil geometry and Nb3Sn superconductor were used to provide field maps for the analysis and optimization of the arc lattice and IR design, as well as for studies of beam dynamics and magnet protection against radiation. The stress management in the coil will be needed to avoid large degradation or even damage of the brittle SC coils. In the assumed IR designs, the dipoles close to the Interaction Point (IP) and tungsten masks in each IR (to protect magnets) help reducing background particle fluxes in the detector by a substantial factor. The tungsten nozzles in the 6 to 600 cm region from the IP, assisted by the detector solenoid field, trap most of the decay electrons created close to the IP as well as most of the incoherent electron-positron pairs generated in the IP. With sophisticated tungsten, iron, concrete and borated polyethylene shielding in the MDI region, the total reduction of background loads by more than three orders of magnitude can be achieved.

43 PARTICLE ACCELERATORS↗

A conceptual model for how to design for building envelope characteristics. Impact of thermal comfort intervals and thermal mass on commercial buildings in U.S. climates

The paper presents a simplified conceptual model for energy demand calculations based on building envelope characteristics, thermal mass and local climate. It is based on a network model and lumped analysis of the dynamic process. Characteristic parameters for the buildings are suggested; Driving temperature (DT), Driving temperature difference, (DTD), External Load Temperature (ELT), and Thermal Load Resistance (TLR). The Building Envelope Performance ( BEP 0 ), based on a controlled constant indoor temperature is introduced. Solution techniques using stable explicit forward differences based on analytical solutions are derived. The conceptual model has been used for mapping the Driving temperature difference and introduced two performance factors and . The first factor represents the effect of thermal comfort interval and thermal mass on the energy demand. The latter represents the ratio between cooling and heating energy demand. These three parameters and factors have been visualized on U.S. maps and enable a possibility to communicate the demand of energy, and cooling and the coupling to building characteristics, in a concise way.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Test of Functional Balance Theory for Wetland Biomass Allocation in a Global Change Experiment

Abstract Forecasts of root growth and carbon sequestration under global change are compromised by uncertainty in how plants will allocate biomass between above and belowground pools. Here, we develop a simple model to assess whether functional balance theory can explain a complex biomass allocation response observed in a brackish marsh under experimental warming and elevated CO 2 . Our model shows how treatment‐driven changes in nitrogen supply and demand can explain divergent observations of root growth (i.e., maximum responses under intermediate warming and elevated CO 2 ). The model also reveals a surprising interaction between warming and eutrophication, where enhanced N loading to coastal marshes may reduce adverse impacts of warming on root growth. Our findings provide a mechanistic basis for incorporating biomass allocation into forecast models of marsh evolution. They also provide a general example of using ecological theory to decompose complex net responses observed in multi‐factor global change experiments into constituent processes.

54 ENVIRONMENTAL SCIENCES↗

Heuristic predictions of RMP configurations for ELM suppression in ITER burning plasmas and their impact on divertor performance

Abstract A subspace of resonant magnetic perturbation (RMP) configurations for edge localized mode (ELM) suppression is predicted for H-mode burning plasmas at 15 MA current and 5.3 T magnetic field in ITER. Perturbations to the core plasma can be reduced by a factor of 2 for equivalent edge stability proxies, while the perturbed plasma boundary geometry remains mostly resilient. The striated domain of perturbed field lines connecting from the main plasma (normalized poloidal flux < 1 ) to the divertor targets is found to be significantly larger than the expected heat load width in the absence of RMPs. This facilitates heat load spreading with peak values at an acceptable level below 10 MW m − 2 on the outer target already at moderate gas fueling and low Ne seeding for additional radiative dissipation of the 100 MW of power into the scrape-off layer (SOL). On the inner target, however, re-attachment is predicted away from the equilibrium strike point due to increased upstream heat flux, higher downstream temperature and less efficient impurity radiation.

3D plasma boundary modeling↗

Structural dynamics modeling of spent nuclear fuel during hypothetical package drop events

The response of spent nuclear fuel (SNF) to hypothetical package drop events is of particular interest in the scope of spent fuel storage and transportation because of the mechanical shock encountered in such scenarios. Previous testing and modeling by the U.S. Department of Energy has demonstrated that the shock and vibration environment of normal shipping and handling conditions (excluding package drop events) is relatively benign and does not challenge the integrity of spent nuclear fuel. Cask drop events are worth considering because SNF packages are required to withstand free drops onto unyielding surfaces as part of their licensing basis. The acceleration experienced during drop events can be orders of magnitude higher, and thus more advanced models are needed to encompass potential nonlinear behavior of the fuel, such as spacer grid buckling and rod-to-rod impact. This work describes a number of finite element models developed to calculate the response of spent nuclear fuel to various hypothetical drop events that have been validated by package and fuel assembly drop tests conducted in the last decade. Sensitivity of the model response to factors such as package drop orientation, secondary impacts, and irradiated material properties as well as their potential impacts to fuel cladding integrity, was also investigated. Cask drops are not expected as a regular occurrence during SNF transportation, but this work helps raise the understanding of SNF mechanical loads to the point of consistency with the package design requirements.

Kadooka, Kevin↗

Temperature Effect of Cesium Exchange onto Crystalline Silicotitanate in AP-107 and AP-105 Hanford Tank Wastes and Two Simulants

Washington River Protection Solutions, LLC (WRPS) is charged with the development of the Tank Side Cesium Removal (TSCR) system to process Hanford tank waste supernates in preparation for vitrification. In addition to a filtration step, TSCR will remove cesium (Cs) using ion exchange columns filled with crystalline silicotitanate (CST) ion exchange media. CST is produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for the TSCR system limits a single column loading to 141,600 Ci 137 Cs. Given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of 596 L (157.5 gal) in a TSCR column, this equates to 0.10 mmole Cs per g CST (Cs distribution coefficient, K d , 1400 mL/g). Factors that influence Cs uptake by CST include (but are not limited to) (1) CST production (lot-to-lot variations), (2) contact temperature, (3) contact duration, (4) competitors in the tank waste feed, (5) anionic composition of the tank waste feed, and (6) the 137 Cs isotopic mass fraction (differs slightly among tank wastes and decreases with time).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A One-dimensional Heat Transfer Model for a Cooled Airfoil in a Direct-fired Supercritical CO 2 Turbine

A one-dimensional (1-D) heat transfer model was developed to predict the performance of a cooled airfoil for a supercritical carbon dioxide (sCO 2 ) turbine. The model included the effects of film cooling effectiveness, thermal barrier coating thickness, and internal Nusselt number augmentation. Trends for overall cooling effectiveness versus heat load parameter were obtained for over twelve unique thermal management schemes. The study found that adding a thermal barrier coating was the most effective scheme for increasing the airfoil overall cooling effectiveness. Internal cooling technologies have diminishing returns as the heat transfer coefficient augmentation increases past a factor of five, however the sensitivity of overall cooling effectiveness to heat transfer augmentation scales by a factor of 1.3 when a thermal barrier coating is introduced. Film cooling is seen as a long-term research area which will be inevitably explored as direct sCO 2 systems develop a market presence. However, the model indicates that realizable film cooling effectiveness levels yield a smaller improvement in overall cooling effectiveness than a thermal barrier coating.

42 ENGINEERING↗

AC Power Flow Based DLMP Calculation and Decomposition Method to Smooth Power Fluctuation of Distributed Renewable Energy Sources

As the penetration of renewable energy sources increases, the growing renewable power variability brings ramping issues to power systems. Meanwhile, the development of distributed energy resources (DERs) makes the distribution systems to provide both energy and ancillary services. To incentivise individual resources and customers to alleviate ramping issues on the demand side, a two-stage distribution locational marginal price (DLMP) calculation and decomposition method is developed to formulate the marginal power ramping price for DERs. In the first stage of the proposed method, a distribution system operator market scheduling model based on AC optimal power flow is designed to estimate the optimal operating point of the distribution system. Subsequently, the voltage and power flow constraints are linearised in stage two to calculate DLMP. Finally, based on the Lagrange function and sensitivity factors, DLMP is decomposed to the marginal costs for active/reactive power, voltage management, power loss and power variability. Case studies demonstrate that the proposed model can effectively smooth the power fluctuation and reduce the ramping flexibility requirements of distribution systems.

AC optimal power flow↗

Microgrid Resilience: A Holistic and Context-Aware Resilience Metric

Microgrids present an effective solution for the coordinated deployment of various distributed energy resources and furthermore provide myriad additional benefits such as resilience, decreased carbon footprint, and reliability to energy consumers and the energy system as a whole. Boosting the resilience of distribution systems is another major benefit of microgrids. This is because they can also serve as a backup power source when the utility grid's operations are interrupted due to either high-probability low-impact events like a component failure or low-probability high-impact events - be it a natural disaster or a planned cyberattack. However, the degree to which any particular system can defend, adapt, and restore normal operation depends on various factors including the type and severity of events to which a microgrid is subjected. These factors, in turn, are dependent on the geographical location of the deployed microgrid as well as the cyber risk profile of the site where the microgrid is operating. Therefore, in this work, we attempt to capture this multi-dimensional interplay of various factors in quantifying the ability of the microgrid to be resilient in these varying aspects. This paper, thus, proposes a customized site-specific quantification of the resilience strength for the individual microgrid's capability to absorb, restore, and adapt to the changing circumstances for sustaining the critical load when a low-probability high-impact event occurs - termed as - context-aware resilience metric. We also present a case study to illustrate the key elements of our integrated analytical approach.

microgrid↗

Dry-processed electrodes enabled by polytetrafluoroethylene fibrillation for high-performance lithium-ion batteries

The dry processing technique of polytetrafluoroethylene (PTFE) fibrillation offers significant advancements in cost reduction, environmental impact, and electrochemical performance. Dry processing alone allows for ∼ 20–60% cost reduction and increases of up to 40 mg cm⁻2 of areal loading – it typically comes at a reduction of rate capability. By leveraging the network structure of fibers, this method enhances rate capability and cycling performance, providing a compelling alternative to the conventional and currently predominant wet processing. The review delves into PTFE fibrillation mechanisms and examines critical influencing factors including material properties and processing parameters. It also discusses challenges associated with the electrodes fabricated by PTFE fibrillation, including structural instability due to insufficient PTFE fibrillization, compromised electrical conductivity from an insufficient conductive network, inhomogeneous dispersion resulting from the absence of solvents, restricted ionic transport due to increased electrode thickness, inadequate adhesion to current collector because of low surface energy of PTFE, electrochemical degradation due to low lowest unoccupied molecular orbital (LUMO) level of PTFE, particle damage during processing and environmental concerns related PTFE being a perfluoroalkyl and polyfluoroalkyl substances (PFAS). Recent research innovations aimed at mitigating these issues, their application in beyond-lithium batteries, and future research directions are thoroughly discussed.

Park, Hyunji↗

MHD stability and disruptions in the SPARC tokamak

SPARC is being designed to operate with a normalized beta of $β_N$ = 1.0, a normalized density of $n_G$ = 0.37 and a safety factor of $q_{95}$ ≈ 3.4, providing a comfortable margin to their respective disruption limits. Further, a low beta poloidal $β_p$ = 0.19 at the safety factor $\textit{q}$ = 2 surface reduces the drive for neoclassical tearing modes, which together with a frozen-in classically stable current profile might allow access to a robustly tearing-free operating space. Although the inherent stability is expected to reduce the frequency of disruptions, the disruption loading is comparable to and in some cases higher than that of ITER. The machine is being designed to withstand the predicted unmitigated axisymmetric halo current forces up to 50 MN and similarly large loads from eddy currents forced to flow poloidally in the vacuum vessel. Runaway electron (RE) simulations using GO+CODE show high flattop-to-RE current conversions in the absence of seed losses, although NIMROD modelling predicts losses of ~80 %; self-consistent modelling is ongoing. A passive RE mitigation coil designed to drive stochastic RE losses is being considered and COMSOL modelling predicts peak normalized fields at the plasma of order 10 –2 that rises linearly with a change in the plasma current. Massive material injection is planned to reduce the disruption loading. A data-driven approach to predict an oncoming disruption and trigger mitigation is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗