Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lighting quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

Trend Quality Ozone from NPP OMPS: The Version 2 Processing

A version 2 processing of data from two ozone monitoring instruments on Suomi NPP, the OMPS nadir ozone mapper and the OMPS nadir ozone profiler, has now been completed. The previously released data were useful for many purposes but were not suitable for use in ozone trend analysis. In this processing, instrument artifacts have been identified and corrected, an improved scattered light correction and wavelength registration have been applied, and soft calibration techniques were implemented to produce a calibration consistent with data from the series of SBUV/2 instruments. The result is a high-quality ozone time series suitable for trend analysis. Total column ozone data from the OMPS nadir mapper now agree with data from the SBUV/2 instrument on NOAA 19 with a zonal average bias of −0.2 % over the 60° S to 60° N latitude zone. Differences are somewhat larger between OMPS nadir profiler and N19 total column ozone, with an average difference of −1.1 % over the 60° S to 60° N latitude zone and a residual seasonal variation of about 2 % at latitudes higher than about 50°. For the profile retrieval, zonal average ozone in the upper stratosphere (between 2.5 and 4 hPa) agrees with that from NOAA 19 within ±3 % and an average bias of −1.1 %. In the lower stratosphere (between 25 and 40 hPa) agreement is within ±3 % with an average bias of +1.1 %. Tropospheric ozone produced by subtracting stratospheric ozone measured by the OMPS limb profiler from total column ozone measured by the nadir mapper is consistent with tropospheric ozone produced by subtracting stratospheric ozone from MLS from total ozone from the OMI instrument on Aura. The agreement of tropospheric ozone is within 10 % in most locations.

OMPS nadir ozone mapper↗

Improving the Optical Quality Factor of the WGM Resonator

Resonators usually are characterized with two partially dependent values: finesse (F) and quality factor (Q). The finesse of an empty Fabry-Perot (FP) resonator is defined solely by the quality of its mirrors and is calculated as F=piR(exp 1/2)/(1-R). The maximum up-to-date value of reflectivity R approximately equal to 1 - 1.6 x 10(exp -6) is achieved with dielectric mirrors. An FP resonator made with the mirrors has finesse F=1.9 x 10(exp 6). Further practical increase of the finesse of FP resonators is problematic because of the absorption and the scattering of light in the mirror material through fundamental limit on the reflection losses given by the internal material losses and by thermodynamic density fluctuations on the order of parts in 109. The quality factor of a resonator depends on both its finesse and its geometrical size. A one-dimensional FP resonator has Q=2 F L/lambda, where L is the distance between the mirrors and lambda is the wavelength. It is easy to see that the quality factor of the resonator is unlimited because L is unlimited. F and Q are equally important. In some cases, finesse is technically more valuable than the quality factor. For instance, buildup of the optical power inside the resonator, as well as the Purcell factor, is proportional to finesse. Sometimes, however, the quality factor is more valuable. For example, inverse threshold power of intracavity hyperparametric oscillation is proportional to Q(exp 2) and efficiency of parametric frequency mixing is proportional to Q(exp 3). Therefore, it is important to know both the maximally achievable finesse and quality factor values of a resonator. Whispering gallery mode (WGM) resonators are capable of achieving larger finesse compared to FP resonators. For instance, fused silica resonators with finesse 2.3 x 10(exp 6) and 2.8 x 10(exp 6) have been demonstrated. Crystalline WGM resonators reveal even larger finesse values, F=6.3 x 10(exp 6), because of low attenuation of light in the transparent optical crystals. The larger values of F and Q result in the enhancement of various nonlinear processes. Low-threshold Raman lasing, optomechanical oscillations, frequency doubling, and hyperparametric oscillations based on these resonators have been recently demonstrated. Theory predicts a possibility of nearly 10(exp 14) room-temperature optical Q-factors of optical crystalline WGM resonators, which correspond to finesse levels higher than 10(exp 9). Experiments have shown numbers a thousand times lower than that. The difference occurs due to media imperfections. To substantially reduce the optical losses caused by the imperfections, a specific, multi-step, asymptotic processing of the resonator is implemented. The technique has been initially developed to reduce microwave absorption in dielectric resonators. One step of the process consists of mechanical polishing performed after high temperature annealing. Several steps repeat one after another to lead to significant reduction in optical attenuation and, as a result, to the increase of Q-factor as well as finesse of the resonator which demonstrates a CaF2 WGM resonator with F greater than 10(exp 7) and Q greater than 10(exp 11).

Savchenkov, Anatoliy↗

Single thermodynamic transition at 2 K in superconducting UTe 2 single crystals

UTe 2 is a newly-discovered unconventional superconductor wherein multicomponent topological superconductivity is anticipated based on the presence of two superconducting transitions and time-reversal symmetry breaking in the superconducting state. The observation of two superconducting transitions, however, remains controversial. Here we demonstrate that UTe 2 single crystals displaying an optimal superconducting transition temperature at 2 K exhibit a single transition and remarkably high quality supported by their large residual resistance ratio and small residual heat capacity in the superconducting state. Our results shed light on the intrinsic superconducting properties of UTe 2 and bring into question whether UTe 2 is a multicomponent superconductor at ambient pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of crystalline quality of traveling heater method (THM) grown Cd0.9Zn0.1Te0.98Se0.02 crystals

Because of its excellent opto-electronic properties, CdZnTe (CZT) has been the material of choice for x- and gamma-ray detectors operable at room temperature. CZT is the leading commercially available room-temperature radiation detector material today. Although much progress has been made over the past three decades, today's CZT crystals still face certain challenges, especially the presence of the performance-limiting materials defects and the associated relatively high production cost. In this regard, CdxZn1−xTeySe1−y (CZTS) is emerging as a next-generation compound semiconductor, which overcomes some of the limitations of CZT technology for the stated applications. Here, we conducted a study to evaluate the crystalline quality of the traveling heater method grown CZTS with an optimized alloy composition, i.e., Cd0.9Zn0.1Te0.98Se0.02. The as-grown samples were evaluated by low-temperature photoluminescence (PL) spectroscopy and high-resolution x-ray diffraction using the synchrotron light source at Brookhaven National Laboratory. The full width at half maximum of both the PL and x-ray rocking curves was observed to be broadened due to the lattice disorder of the quaternary compound, eventually degrading the crystalline quality. This was consistent with density functional theory calculations.

Roy, U. N. (ORCID:0000000282089680)↗

Excitation functions of proton-induced nuclear reactions on $$^{86}$$Sr, with particular emphasis on the formation of isomeric states in $$^{86}$$Y and $$^{85}$$Y

Abstract Cross sections of proton-induced nuclear reactions on enriched $$^{\mathrm {86}}$$ 86 Sr target were measured by the activation technique up to proton energies of 44 MeV. The isomeric cross-section ratios for $$^{\mathrm {86m,g}}$$ 86 m , g Y and $$^{\mathrm {85m,g}}$$ 85 m , g Y as a function of projectile energy were deduced from their measured data. The present experimental data for the nuclear reaction products, namely $$^{\mathrm {86m}}$$ 86 m Y, $$^{\mathrm {86g+xm}}$$ 86 g + xm Y, $$^{\mathrm {85m}}$$ 85 m Y, $$^{\mathrm {85g}}$$ 85 g Y, $$^{\mathrm {84}}$$ 84 Rb and $$^{\mathrm {83}}$$ 83 Rb were compared with the results of nuclear model calculations using the code TALYS, which combines the statistical, precompound, and direct interactions. In general, the experimental cross-section data as well as the isomeric cross-section ratios are reproduced well by the model calculations, provided the input model parameters are properly chosen and the level structure of the product nucleus is thoughtfully considered. The quality of the agreement between experimental data and model calculations was numerically quantified. For products formed via emission of a light complex particle as well as multi-nucleons (e.g., $$\alpha $$ α and 2p2n), the contribution of the latter process starts increasing when its energy threshold is crossed.

Uddin, M. S.↗

Three-dimensional imaging of proton in basis light-front quantization

Here, we employ an effective Hamiltonian that includes the transverse and longitudinal confinement and the one-gluon exchange interaction with fixed coupling constant. By solving the eigenvalue equation in basis light-front quantization (BLFQ), we generate the light-front wavefunctions (LFWFs) for the nucleon in the valence quark Fock space. Fitting the model parameters, we obtain high quality descriptions of electromagnetic form factors and radius for proton while the results deviate somewhat from experimental data for neutron.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Opto-electronic properties of cells made from various silicon forms

Opto-electronic properties of the various silicon forms were obtained from the solar cell performance. Performance parameters included the photovoltaic characteristics, minority carrier diffusion length, spectral response and small light spot scanning. Self consistent results were obtained from the various measurement techniques, which can provide useful information on sheet quality, as a potential for low cost terrestrial applications, and areas where the sheet formation methods can be improved.

Yoo, H.↗

Fluorescent Gage Indication

Transfer of dye shows quality of contact between two mating parts. Mating parts checked for fit by spreading fluorescent dye on one, making brief light contact with other, and looking (under UV light) for transferred dye. Dye offers greater visibility under ultraviolet illumination, allowing better indication of how precisely parts match and what areas interfere.

Barns, C. E.↗

Management and display of four-dimensional environmental data sets using McIDAS

Over the past four years, great strides have been made in the areas of data management and display of 4-D meteorological data sets. A survey was conducted of available and planned 4-D meteorological data sources. The data types were evaluated for their impact on the data management and display system. The requirements were analyzed for data base management generated by the 4-D data display system. The suitability of the existing data base management procedures and file structure were evaluated in light of the new requirements. Where needed, new data base management tools and file procedures were designed and implemented. The quality of the basic 4-D data sets was assured. The interpolation and extrapolation techniques of the 4-D data were investigated. The 4-D data from various sources were combined to make a uniform and consistent data set for display purposes. Data display software was designed to create abstract line graphic 3-D displays. Realistic shaded 3-D displays were created. Animation routines for these displays were developed in order to produce a dynamic 4-D presentation. A prototype dynamic color stereo workstation was implemented. A computer functional design specification was produced based on interactive studies and user feedback.

Hibbard, William L.↗

Vision Systems Illuminate Industrial Processes

When NASA designs a spacecraft to undertake a new mission, innovation does not stop after the design phase. In many cases, these spacecraft are firsts of their kind, requiring not only remarkable imagination and expertise in their conception but new technologies and methods for their manufacture. In the realm of manufacturing, NASA has from necessity worked on the cutting-edge, seeking new techniques and materials for creating unprecedented structures, as well as capabilities for reducing the cost and increasing the efficiency of existing manufacturing technologies. From friction stir welding enhancements (Spinoff 2009) to thermoset composites (Spinoff 2011), NASA s innovations in manufacturing have often transferred to the public in ways that enable the expansion of the Nation s industrial productivity. NASA has long pursued ways of improving upon and ensuring quality results from manufacturing processes ranging from arc welding to thermal coating applications. But many of these processes generate blinding light (hence the need for special eyewear during welding) that obscures the process while it is happening, making it difficult to monitor and evaluate. In the 1980s, NASA partnered with a company to develop technology to address this issue. Today, that collaboration has spawned multiple commercial products that not only support effective manufacturing for private industry but also may support NASA in the use of an exciting, rapidly growing field of manufacturing ideal for long-duration space missions.

Source record↗

Discovery and Vetting of Exoplanets. I. Benchmarking K2 Vetting Tools

We have adapted the algorithmic tools developed during the Kepler mission to vet the quality of transit-like signals for use on the K2 mission data. Using the four sets of publicly available light curves at MAST, we produced a uniformly vetted catalog of 772 transiting planet candidates from K2 as listed at the NASA Exoplanet Archive in the K2 Table of Candidates. Our analysis marks 676 of these as planet candidates and 96 as false positives. All confirmed planets pass our vetting tests. Sixty of our false positives are new identifications, effectively doubling the overall number of astrophysical signals mimicking planetary transits in K2 data. Most of the targets listed as false positives in our catalog show either prominent secondary eclipses, transit depths suggesting a stellar companion instead of a planet, or significant photocenter shifts during transit. We packaged our tools into the open-source, automated vetting pipeline Discovery and Vetting of Exoplanets (DAVE), designed to streamline follow-up efforts by reducing the time and resources wasted observing targets that are likely false positives. DAVE will also be a valuable tool for analyzing planet candidates from NASA's TESS mission, where several guest-investigator programs will provide independent light-curve sets—and likely many more from the community. We are currently testing DAVE on recently released TESS planet candidates and will present our results in a follow-up paper.

Kostov, Veselin B.↗

Airborne Remote Sensing Measurements of Particles in Different Parts of the World

Around the globe, atmospheric aerosols pose a significant yet uncertain impact on the Earth's climate, environmental air quality and human health. Suborbital sunphotometer measurements of Aerosol Optical Depth (AOD) (i.e., the amount of direct-beam solar light attenuated by aerosols within the atmospheric column) are used to validate satellite aerosol retrievals and are valuable when studying aerosol-solar radiation and/ or aerosol-cloud interactions. Since 1985, NASA Ames Research Center (ARC) has been using airborne sun-tracking sunphotometers to measure atmospheric constituents such as aerosols, clouds, and gases. The NASA Ames Airborne Tracking Sunphotometer (AATS-6) and then (AATS-14) operate by tracking the sun and measuring the transmission of solar radiation in 6 to 14 discrete spectral channels (Russell et al., 1986). The AATS systems were followed by the more advanced hyperspectral 4STAR instrument (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research; Dunagan et al., 2013), which combines the airborne sun-tracking capability of the AATS-14 with a sky scanning feature similar to the ground-based Aerosol Robotic Network Sun/sky photometers (AERONET). We present a comprehensive analysis of ~30 airborne campaigns undertaken by NASA and DoE based on a new database of airborne sunphotometer measurements. Using this database, we present a clear picture of airborne AODs over the range of historical campaigns and the aerosol sizes per region, especially over the ocean where AERONET data is limited. With this database, we can investigate systematic differences in AOD such as those observed over different land and ocean surfaces in specific geographical regions. Finally, we will briefly show comparisons with satellite aerosol retrievals from MODIS and/or VIIRS. Russell, P. B., T. Matsumoto, V. J. Banta, J. M. Livingston, C. Mina, D. S. Colburn, and R. F. Pueschel (1986), Measurements with an airborne, autotracking, external-head sunphotometer, Preprint Volume, Sixth Conference on Atmospheric Radiation, May 13–16, 1986, Amer. Meteor.Soc., Boston, MA, 55–58. Dunagan, Stephen E., et al. "Spectrometer for sky-scanning sun-tracking atmospheric research (4STAR): Instrument technology." Remote Sensing 5.8 (2013): 3872-3895

Brendan Stover Cornelison↗

Feasibility and preliminary efficacy for morning bright light therapy to improve sleep and plasma biomarkers in US Veterans with TBI. A prospective, open-label, single-arm trial

Mild traumatic brain injury (TBI) is associated with persistent sleep-wake dysfunction, including insomnia and circadian rhythm disruption, which can exacerbate functional outcomes including mood, pain, and quality of life. Present therapies to treat sleep-wake disturbances in those with TBI (e.g., cognitive behavioral therapy for insomnia) are limited by marginal efficacy, poor patient acceptability, and/or high patient/provider burden. Thus, this study aimed to assess the feasibility and preliminary efficacy of morning bright light therapy, to improve sleep in Veterans with TBI (NCT03578003). Thirty-three Veterans with history of TBI were prospectively enrolled in a single-arm, open-label intervention using a lightbox (~10,000 lux at the eye) for 60-minutes every morning for 4-weeks. Pre- and post-intervention outcomes included questionnaires related to sleep, mood, TBI, post-traumatic stress disorder (PTSD), and pain; wrist actigraphy as a proxy for objective sleep; and blood-based biomarkers related to TBI/sleep. The protocol was rated favorably by ~75% of participants, with adherence to the lightbox and actigraphy being ~87% and 97%, respectively. Post-intervention improvements were observed in self-reported symptoms related to insomnia, mood, and pain; actigraphy-derived measures of sleep; and blood-based biomarkers related to peripheral inflammatory balance. The severity of comorbid PTSD was a significant positive predictor of response to treatment. Morning bright light therapy is a feasible and acceptable intervention that shows preliminary efficacy to treat disrupted sleep in Veterans with TBI. A full-scale randomized, placebo-controlled study with longitudinal follow-up is warranted to assess the efficacy of morning bright light therapy to improve sleep, biomarkers, and other TBI related symptoms.

60 APPLIED LIFE SCIENCES↗

Uncertainty Quantification of a Light Water Pulsed-Neutron Die-Away Experiment to Thermal Neutron Scattering Laws

Thermal neutron scattering laws are important nuclear data for many nuclear science and engineering applications. Validation helps to ensure that a thermal neutron scattering law has a high quality and often employs critical benchmarks as integral experiments. Recently, pulsed-neutron die-away benchmarks have been used as an experiment to validate thermal neutron scattering laws. Herein, we evidence how this alternative integral experiment has a high sensitivity to these nuclear data by performing an uncertainty quantification analysis. The analysis randomly sampled the nuclear model parameters associated with hydrogen bound in light water thermal neutron scattering law and sampled other nuclear data that influenced the experiment’s integral parameter (e.g., elastic scattering, absorption in hydrogen and oxygen) from their respective covariance matrices. The thermal neutron scattering law caused an uncertainty in the integral parameter that reached 2.67%, which exceeds by an order of magnitude the uncertainties induced in commonly used thermal solution critical benchmarks. The validation performed here, although limited due to a poor description of the historical experiment, indicated that the ENDF/B-VIII.0 thermal neutron scattering law well predicted the integral parameter. These results motivate further benchmark and validation efforts using pulsed-neutron die-away experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging

Two-photon excitation fluorescence (2PEF) allows imaging of tissue up to about one millimeter in thickness. Typically, reducing fluorescence excitation exposure reduces the quality of the image. However, using deep learning super resolution techniques, these low-resolution images can be converted to high-resolution images. This work explores improving human tissue imaging by applying deep learning to maximize image quality while reducing fluorescence excitation exposure. We analyze two methods: a method based on U-Net, and a patch-based regression method. Both methods are evaluated on a skin dataset and an eye dataset. The eye dataset includes 1200 paired high power and low power images of retinal organoids. The skin dataset contains multiple frames of each sample of human skin. High-resolution images were formed by averaging 70 frames for each sample and low-resolution images were formed by averaging the first 7 and 15 frames for each sample. The skin dataset includes 550 images for each of the resolution levels. We track two measures of performance for the two methods: mean squared error (MSE) and structural similarity index measure (SSIM). For the eye dataset, the patches method achieves an average MSE of 27,611 compared to 146,855 for the U-Net method, and an average SSIM of 0.636 compared to 0.607 for the U-Net method. For the skin dataset, the patches method achieves an average MSE of 3.768 compared to 4.032 for the U-Net method, and an average SSIM of 0.824 compared to 0.783 for the U-Net method. Despite better performance on image quality, the patches method is worse than the U-Net method when comparing the speed of prediction, taking 303 seconds to predict one image compared to less than one second for the U-Net method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tidally Excited Modes and δ Scuti Pulsations in the Eclipsing Triple Star IM Persei

IM Per is a triple star system whose eclipsing pair masses and radii are accurate to within 1%. The Transiting Exoplanet Survey Satellite (TESS) light curve of the program target exhibits partial eclipses and multiple oscillations with millimagnitude-level amplitudes. It is found that the oscillations affect eclipse timing measurements. Binary modeling of the high-quality TESS data indicates that the eclipsing components of the triple system are twin dwarfs with parameters of M {sub 2}/M {sub 1} = 0.995, R {sub 2}/R {sub 1} = 0.901, and Δ(T{sub eff,1}–T{sub eff,2}) = 12 K in an eccentric (e = 0.049), detached configuration. The third light of l {sub 3} = 0.054 may mostly come from a G-type tertiary companion. Our predicted parallax of 1.52 ± 0.09 mas is concurrent with the Gaia measurement of 1.52 ± 0.05 mas. Multifrequency analysis of the outside-eclipse residuals reveals 22 significant pulsation signals: 4 in the gravity-mode region (0.03−2.22 day{sup −1}) and 18 in the pressure-mode region (9.19−25.12 day{sup −1}). Of the low frequencies, f {sub 11} and f {sub 14} are orbital harmonics that can be identified as tidally excited modes. The pulsation periods and constants for the high frequencies, and the position in the Cepheid instability strip demonstrate that the pulsating component of IM Per is a δ Sct variable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quality Data Essential for Modeling Water Cycles Effectively

The experimental and observational data is the backbone of effective modeling of all aspects of water cycles. As the computer technology used for these data gathering efforts has improved dramatically in the recent decades, the environmental conditions these instruments are subjected to remain pretty much the same. These measuring instruments are exposed to the sun light, wind, rain, snow and ice; and they are immersed in dirt, water and mud. All of these are damaging to the electronics components used for data gathering, storage, and transmission, which creates many different kinds of data quality issues that affect the quality and reliability of modeling and prediction efforts.

54 ENVIRONMENTAL SCIENCES↗