Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Optical properties of ion beam textured metals

Copper, silicon, aluminum, titanium and 316 stainless steel were textured by 1000 eV xenon ions from an 8-cm diameter electron bombardment ion source. Copper, silicon, and aluminum developed a cone structure with an average peak-to-peak distance ranging from 1 micron for silicon to 6 microns for aluminum. Titanium and 316 stainless steel developed a serpentine ridge structure. The average peak-to-peak distance for both of these materials was 0.5 micron. Total reflectance for air mass 0 and 2, solar absorptance, and total emittance, normalized for a 425 K black body were calculated from the reflectance measurements. All materials had solar absorptances between 0.93 (stainless steel) and 0.97 (silicon and aluminum). Total emittance values of 0.75, 0.80, and 0.85 for Si, Al, and Cu, respectively, resulted in a solar absorptance/total emittance ratio of approximately 1.2. Titanium and 316 stainless steel had values of 2.6 and 2.9, respectively, for this ratio.

Hudson, W. R.↗

A feasibility study of ion implantation techniques for mass spectrometer calibration

An experimental study was undertaken to examine the feasibility of using ion-implanted filaments doped with either an alkali metal or noble gas for in situ recalibration of onboard mass spectrometers during extended space missions. Implants of rubidium and krypton in rhenium ribbon filaments were subsequently tested in a bakeable 60 deg sector mass spectrometer operating in the static mode. Surface ionization and electron impact ion sources were both used, each yielding satisfactory results. The metallic implant with subsequent ionization provided a means of mass scale calibration and determination of system operating parameters, whereas the noble gas thermally desorbed into the system was more suited for partial pressure and sensitivity determinations.

Koslin, M. E.↗

A technique for mass spectrometer measurements of atomic and molecular oxygen in the lower thermosphere

A neutral mass spectrometer with a quasi-open ion source was flown on each of the Atmosphere Explorer (AE) C, D, and E satellites. The three instruments provided an opportunity to study the effects of different source insert materials on the source surface chemistry. It was found that, after a period of conditioning in space, the recombination coefficient of atomic oxygen on gold appears to be substantially lower than it is on Nichrome V. The lower recombination coefficient on gold allows the spectrometer to directly measure a significant fraction of the incident atomic oxygen, making it possible to distinguish between ambient O and O2. Equations are developed to calculate the atomic and molecular oxygen densities. Preliminary measurements of molecular oxygen densities obtained by this technique agree well with measurements taken in the fly-through mode of operation.

Kayser, D. C.↗

Diffusion and phase change characterization by mass spectrometry

The high temperature diffusion of trace elements in metals and alloys was investigated. Measurements were made by high sensitivity mass spectrometry in which individual atoms were detected, and quantitative data was obtained for zircaloy-2, 304 stainless steel, and tantalum. Additionally, a mass spectrometer was also an analytical tool for determining an allotropic phase change for stainless steel at 955 C, and a phase transition region between 772 C and 1072 C existing for zircaloy-2. Diffusion rates were measured in thin (0.001" (0.0025 cm) and 0.0005" (0.0013 cm)) ribbons which were designed as high temperature thermal ion sources, with the alkali metals as naturally occurring impurities. In the temperature and pressure regime where diffusion measurements were made, the solute atoms evaporated from the ribbon filaments when the impurities diffused to the surface, with a fraction of these impurity atoms ionized according to the Langmuir-Saha relation. The techniques developed can be applied to many other alloys important to space vehicles and supersonic transports; and, with appropriate modifications, to the diffusion of impurities in composites.

Koslin, M. E.↗

The Addition of EI/CI Capability to the Mattauch-herzog Spectrograph with EOID

A modification was made to the Mattauch-Herzog Spectrograph with an electro-optical ion detector (EOID) previously designed and constructed, so that it would be capable of operating not only in the electron-impact (EI) mode of ionization, but also in the chemical ionization (CI) mode. This modification necessitated an effort in three specific design areas: (1) sample inlet; (2) ion source and analyzer regions; and (3) the pumping system. In addition, an appropriate electronics package had to be designed to control and operate the combined EI/CI source.

Fergusson, G. J.↗

Pioneer Venus large probe neutral mass spectrometer

The Pioneer Venus large probe neutral mass spectrometer (LNMS) uses a single focusing magnetic sector field mass analyzer with mass range of 1-208 amu, resolution sufficient to separate the mercury isotopes, and sensitivity sufficient to detect minor constituents in the 1 ppm range relative to the CO2 in the Venus atmosphere. A combination of ion and chemical pumping is used to maintain a vacuum in the mass analyzer and to remove the atmosphere gases which enter the ion source chamber through a special leak. A microprocessor controls the operation of the instrument through a highly efficient peak stepping and data compression program, permitting acquisition of a complete mass spectrum roughly once each minute.

Hoffman, J. H.↗

An experimental and theoretical study of the mean diurnal variation of O/+/, NO/+/, O2/+/, and N2/+/ ions in the mid-latitude F1 layer of the ionosphere

A theoretical model of the diurnal variations in the compositions of the ions O(+), NO(+), O2(+) and N2(+) in the midlatitude F1 layer is presented and compared with measurements made by AE-C. The theoretical model includes the rate coefficients and branching ratios for the dissociative recombination of NO(+), O2(+) and N2(+) with electrons and the ion-atom interchanges of O(+) with N2 and N2(+) with O. Input parameters to the model comprise measurements of ion and electron temperatures, neutral atmosphere composition, the solar EUV flux and the photoelectron spectrum. In general, model calculations are found to agree with satellite measurements, confirming the major ion sources and sinks of the photochemical model, which has an accuracy of + or - 60%.

Torr, D. G.↗

Experimental study of low-energy charge transfer in nitrogen

Total charge transfer cross sections were obtained for the N2(+)-N2 system with relative translational ion energies between 9 and 441 eV. Data were obtained to examine the dependence of total cross section on ion energy. The effect of ion excitation on the cross sections was studied by varying the electron ionization energy in the mass spectrometer ion source over an electron energy range between 14.5 and 32.1 eV. The dependence of total cross section on the neutralization chamber gas pressure was examined by obtaining data at pressure values from 9.9 to 0.000199 torr. Cross section values obtained were compared with experimental and theoretical results of other investigations.

Smith, A.↗

Modification of the electrical and optical properties of polymers

An electron bombardment argon ion source is used to form textured surfaces on polymide and fluorinated ethylene propylene polymers. This treatment improves the optical and electrical properties so that these polymers may be used in industrial and space applications.

Mirtich, M. J.↗

The screen hole plasma sheath of an ion accelerator system

Results of the first probing of the screen hole sheath of an ion accelerator system are presented. The screen hole sheath, represented as a set of equipotential contours, extends over a large distance within the discharge plasma. Under no conditions examined does the sheath enter the screen hole. Edge hole defocusing of multiaperture accelerator systems is due primarily to local plasma density variations rather than adjacent screen hole sheath interactions. The sheath boundary is independent of screen-to-accelerator grid spacing when the grid set is operated at the minimum ion beam divergence condition. Significant ion focusing effects occur in the sheath adjacent to the screen grid webbing leading to increased ion source beam current efficiency with decreasing screen-to-accelerator grid separation and/or screen grid thickness.

Aston, G.↗

Atomic nitrogen in the upper atmosphere of Venus

Atomic nitrogen has been detected in the upper atmosphere of Venus by the Pioneer-Venus Orbiter Neutral Mass Spectrometer (ONMS). Surface recombination of atomic nitrogen with atomic oxygen to form nitric oxide in the ion source allows it to be detected at mass 30. The scale height temperature of the mass 30 peak agrees with the scale height temperatures of the other species if it is assumed to be derived from atomic nitrogen. The diurnal variation of atomic nitrogen is approximately proportional to that of atomic oxygen with an estimated N/O ratio of 1.5% at 150 km.

Kasprzak, W. T.↗

Pioneer Venus Orbiter neutral gas mass spectrometer experiment

The Pioneer Venus Orbiter Neutral Mass Spectrometer (ONMS) is designed to measure the vertical and horizontal density variations of the major neutral constituents in the upper atmosphere of Venus. The mass spectrometer sensor includes a retarding potential ion source, hyperbolic quadrupole rod analyzer, and electron multiplier detector. The supporting electronic system consists of hybrid integrated circuits to reduce weight and power. The ONMS instrument was launched aboard the Pioneer Venus Orbiter on May 20, 1978, and turned on in orbit around Venus on December 4, 1978. It has operated flawlessly for over a Venus year (243 earth days) and has returned data of the composition of the major constituents in the Venus atmosphere between the altitudes of 150 and 350 km.

Niemann, H. B.↗

Pioneer Venus Sounder Probe Neutral Gas Mass Spectrometer

A neutral gas mass spectrometer was flown to Venus as part of the Pioneer Venus Multiprobe to measure the composition of its lower atmosphere. The instrument, mounted in the Sounder Probe, was activated after the probe entered the top of the atmosphere, and it obtained data during the descent from 62 km to the surface. Atmospheric gases were sampled through a pair of microleaks, the effluent from which was pumped by a combination of ion and getter pumping. A pneumatically operated valve, controlled by the ambient atmospheric pressure, maintained the ion source pressure at a nearly constant value during descent while the atmospheric pressure varied by three orders of magnitude. A single focusing magnetic sector field mass spectrometer with mass resolution sufficient to reasonably separate argon from C3H4 at 40 amu provided the mass analysis and relative abundance measurements. A microprocessor controlled the operation of the mass spectrometer through a highly efficient peak-tip stepping routine and data compression algorithm that effected a scan of the mass spectrum from 1 to 208 amu in 64 sec while requiring an information rate of only 40 bits/sec to return the data to earth. A subscale height altitude resolution was thus obtained. Weight, size, and power requirements were minimized to be consistent with interplanetary flight contraints.

Hoffman, J. H.↗

High sensitivity pulse-counting mass spectrometer system for noble gas analysis

A pulse-counting mass spectrometer is described which is comprised of a new ion source of cylindrical geometry, with exceptional optical properties (the Baur source), a dual focal plane externally adjustable collector slits, and a 17-stage Allen-type electron multiplier, all housed in a metal 21 cm radius, 90 deg magnetic sector flight tube. Mass discrimination of the instrument is less than 1 per mil per mass unit; the optical transmission is more than 90%; the source sensitivity (Faraday collection) is 4 ma/torr at 250 micron emission; and the abundance sensitivity is 30,000.

Hohenberg, C. M.↗

Ion beam applications research. A summary of Lewis Research Center Programs

A summary of the ion beam applications research (IBAR) program organized to enable the development of materials, products, and processes through the nonpropulsive application of ion thruster technology is given. Specific application efforts utilizing ion beam sputter etching, deposition, and texturing are discussed as well as ion source and component technology applications.

Banks, B. A.↗

Adherence of ion beam sputter deposited metal films on H-13 steel

An electron bombardment argon ion source sputter deposited 17 metals and metal oxides on H-13 steel. The films ranged 1 to 8 micrometers in thickness and their adherence was generally greater than the capacity of the measuring device; adherence quality depended on proper precleaning of the substrate before deposition. N2 or air was introduced for correct stoichiometry in metallic compounds. Au, Ag, MgO, and Ta5Si3 films 8 microns thick have bond strength equal to 1 micron coatings; the bond strength of pure metallic films up to 5 microns thick was greater than the epoxy to film bond (8000 psi). The results of exposures of coated material to temperatures up to 700 C are presented.

Mirtich, M. J.↗

The Jupiter hot plasma torus - Observed electron temperature and energy flows

The detection of the optical emission /O I/ 6300 A (8 + or - 4 R) and /S III/ 6312 A (48 + or - 5 R) is reported. It is noted that these emissions are indicators of the ion source morphology and the plasma physical state and that the S III emitters have a kinetic temperature of approximately 10 to the 6th K. When combined with observations of UV lines from the same species, the optical measurements separately imply effective electron temperatures for radiative processes that are mutually consistent (approximately 50,000 K).

Brown, R. A.↗

Ion beam applications research - A 1981 summary of Lewis Research Center programs

In 1975 the NASA's Lewis Research Center initiated a technology specific spinoff program to more broadly utilize benefits resulting from ion thruster technology. An Ion Beam Applications Research (IBAR) program was organized to enable the development of new or improved materials, products, and processes through the nonpropulsive application of ion thruster technology. Focused efforts to identify, evaluate, develop and transfer applications to the user community were conducted. A summary of the NASA Lewis Research Center's in-house, grant, and contract projects involving IBAR is given. Specific application efforts utilizing ion beam sputter etching, deposition, and texturing are discussed as well as ion source and component technology applications.

Banks, B. A.↗