Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image classification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Relationship of myocardial hibernation, scar, and angiographic collateral flow in ischemic cardiomyopathy with coronary chronic total occlusion

Background: The relationship between myocardial viability and angiographic collateral flow is not fully elucidated in ischemic cardiomyopathy (ICM) with coronary artery chronic total occlusion (CTO). We aimed to clarify the relationship between myocardial hibernation, myocardial scar, and angiographic collateral flow in these patients. Methods and Results: Seventy-one consecutive ICM patients with 122 CTOs and 652 dysfunctional segments within CTO territories were retrospectively analyzed. Myocardial hibernation (perfusion-metabolism mismatch) and the extent of {sup 18}F-fluorodeoxyglucose (FDG) abnormalities were assessed using {sup 99m}Tc-sestamibi and {sup 18}F–FDG imaging. Myocardial scar was evaluated by late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging. Collateral flow observed on coronary angiography was assessed using Rentrop classification. In these patients, neither the extent nor frequency of myocardial hibernation or scar was related to the status of collateral flow. Moreover, the matching rate in determining myocardial viability was poor between any 2 imaging indices. The extent of {sup 18}F-FDG abnormalities was linearly related to the extent of LGE rather than myocardial hibernation. Of note, nearly one-third (30.4%) of segments with transmural scar still had hibernating tissue. Hibernation and non-transmural scar had higher sensitivity (63.0% and 66.7%) than collateral flow (37.0%) in predicting global functional improvement. Conclusions: Angiographic collateral cannot accurately predict myocardial viability, and has lower sensitivity in prediction of functional improvement in CTO territories in ICM patients. Hence, assessment of myocardial viability with non-invasive imaging modalities is of importance. Moreover, due to the lack of correlation between myocardial hibernation and scar, these two indices are complementary but not interchangeable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion-Weighted MRI Assessment of Adjacent Disc Degeneration After Thoracolumbar Vertebral Fractures

ObjectiveThe purpose of this study was to assess, by the mean apparent diffusion coefficient (ADC), if a relationship exists between disc ADC and MR findings of adjacent disc degeneration after thoracolumbar fractures treated by anatomic reduction using vertebral augmentation (VAP).Materials and MethodsTwenty non-consecutive patients (mean age 50.7 years; range 45–56) treated because of vertebral fractures, were included in this study. There were 10 A3.1 and 10 A1.2 fractures (AO classification). Surgical treatment using VAP was applied in 14 cases, and conservative in 6 patients. MRI T2-weighted images and mapping of apparent diffusion coefficient (ADC) of the intervertebral disc adjacent to the fractured segment were performed after a mean follow-up of 32 months. A total of 60 discs, 3 per patient, were analysed: infra-adjacent, supra-adjacent and a control disc one level above the supra-adjacent.ResultsNo differences between patients surgically treated and those following a conservative protocol regarding the average ADC values obtained in the 20 control discs analysed were found. Considering all discs, average ADC in the supra-adjacent level was lower than in the infra-adjacent (1.35 ± 0.12 vs. 1.53 ± 0.06; p < 0.001). Average ADC values of the discs used as a control were similar to those of the infra-adjacent level (1.54 ± 0.06). Compared to surgically treated patients, discs at the supra-adjacent fracture level showed statistically significant lower values in cases treated conservatively (p < 0.001). The variation in the delay of surgery had no influence on the average values of ADC at any of the measured levels.ConclusionsADC measurements of the supra-adjacent discs after a mean follow-up of 32 months following thoracolumbar fractures, showed that restoration of the vertebral collapse by minimally invasive VAP prevents posttraumatic disc degeneration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep Learning for Automated Identification of Eels in Sonar Data

Freshwater eels, such as the American eel (Anguilla rostrata) present numerous challenges related to safe downstream fish passage at hydroelectric facilities. One of those challenges is effective monitoring of their abundance, movements, and behavior to facilitate design and operation of eel protection and passage facilities. A previous EPRI study documented the ability of human analysts to reliably identify American eels in data obtained with a 1100/1800 kHz, multibeam sonar. This report describes a project to develop deep learning (a subset of artificial intelligence) tools to automate the time-consuming, subjective process of eel identification in multibeam sonar data. The project exploited new data collected in the laboratory and the existing data from the prior EPRI field study to develop and test deep learning and other data analytic tools, including wavelet filtering, differencing for static object removal, and convolutional neural network analysis. The analysis of the laboratory data demonstrated feasibility of the approach, revealed object characteristics observed with the sonar that distinguish eels from similarly sized and shaped acoustic targets, and provided additional data for algorithm selection and training. Deep learning algorithms trained and tested on the laboratory data alone achieved accuracy rates of greater than 98% when classifying acoustic images of eels and similar-sized neutrally buoyant sticks. The algorithm trained and tested on the pre-existing field data alone, and yielded classification accuracy of 9.3% false positives and 13.3% false negatives when distinguishing between eels and sticks/PVC pipes based on video clips (i.e., multiple, consecutive images). This performance is comparable to the classification accuracy achieved by human analysts in the prior study. The deep learning algorithm trained on a combination of video clips obtained in the laboratory and the field and tested on video clips from the field, was able to distinguish eels from sticks and PVC pipes (a river debris analog) of similar size with 100% accuracy. Outreach to the hardware, software, and end-user communities early in the project helped to identify needs and specify the application space. Outreach to those communities at the end of the project communicated project results and opportunities for further development. The project achieved proof of concept for automated identification of eel in multibeam sonar data. Future work should focus on acquisition of additional data for more robust algorithm training and testing; modification of the software tools to accommodate multiple acoustic targets in the acoustic field at a given time; identification of additional object classes; incorporation of motion in the object identification and classification algorithms; operationalizing the software tools, including integration with other existing sonar data analysis tools; and partnering with hardware and software providers for distribution of the software tools with their commercial products.

13 HYDRO ENERGY↗

Detection of Modified Matrix Encoding Using Machine Learning and Compressed Sensing

In recent years, driven by the development of steganalysis methods, steganographic algorithms have been evolved rapidly with the ultimate goal of an unbreakable embedding procedure, resulting in recent steganographic algorithms with minimum distortions, exemplified by the recent family of Modified Matrix Encoding (MME) algorithms, which has shown to be most difficult to be detected. In this paper we propose a compressed sensing based on approach for intrinsic steganalysis to detect MME stego messages. Compressed sensing is a recently proposed mathematical framework to represent an image (in general, a signal) using a sparse representation relative to an overcomplete dictionary by minimizing the l1-norm of resulting coefficients. Here we first learn a dictionary from a training set so that the performance will be optimized using the KSVD algorithm; since JPEG images are processed by 8x8 blocks, the training examples are 8x8 patches, rather than the entire images and this increases the generalization of compressed sensing. For each 8x8 block, we compute its sparse representation using OMP (orthogonal matching pursuit) algorithm. Using computed sparse representations, we train a support vector machine (SVM) to classify 8x8 blocks into stego and non-stego classes. Then given an input image, we first divide it into 8x8 blocks. For each 8x8 block, we compute its sparse representation and classify it using the trained SVM. After all the 8x8 blocks are classified, the entire image is classified based on the majority rule of 8x8 block classification results. This allows us to achieve a robust decision even when 8x8 blocks can be classified only with relatively low accuracy. We have tested the proposed algorithm on two datasets (Corel-1000 dataset and a remote sensing image dataset) and have achieved 100% accuracy on classifying images, even though the accuracy of classifying 8x8 blocks is only 80.89%. Key Words Compressed Sensing, Sparcity, Data Dictionary, Steganography, steganalysis

Allen, Josef D↗

Quality Improvement Guidelines for Imaging Detection and Treatment of Endoleaks following Endovascular Aneurysm Repair (EVAR)

Major concerns after aortic aneurysm repair are caused by the presence of endoleaks, which are defined as persistent perigraft flow within the aortic aneurysm sac. Diagnosis of endoleaks can be performed with various imaging modalities, and indications for treatment are based on further subclassifications. Early detection and correct classification of endoleaks are crucial for planning patient management. The vast majority of endoleaks can be treated successfully by interventional means. Guidelines for Imaging Detection and Treatment of endoleaks are described in this article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE PHOTOMETRIC CLASSIFICATION SERVER FOR Pan-STARRS1

The Pan-STARRS1 survey is obtaining multi-epoch imaging in five bands (g{sub P1} r{sub P1} i{sub P1} z{sub P1} y{sub P1}) over the entire sky north of declination -30 deg. We describe here the implementation of the Photometric Classification Server (PCS) for Pan-STARRS1. PCS will allow the automatic classification of objects into star/galaxy/quasar classes based on colors and the measurement of photometric redshifts for extragalactic objects, and will constrain stellar parameters for stellar objects, working at the catalog level. We present tests of the system based on high signal-to-noise photometry derived from the Medium-Deep Fields of Pan-STARRS1, using available spectroscopic surveys as training and/or verification sets. We show that the Pan-STARRS1 photometry delivers classifications and photometric redshifts as good as the Sloan Digital Sky Survey (SDSS) photometry to the same magnitude limits. In particular, our preliminary results, based on this relatively limited data set down to the SDSS spectroscopic limits, and therefore potentially improvable, show that stars are correctly classified as such in 85% of cases, galaxies in 97%, and QSOs in 84%. False positives are less than 1% for galaxies, Almost-Equal-To 19% for stars, and Almost-Equal-To 28% for QSOs. Moreover, photometric redshifts for 1000 luminous red galaxies up to redshift 0.5 are determined to 2.4% precision (defined as 1.48 Multiplication-Sign Median|z{sub phot} - z{sub spec}|/(1 + z)) with just 0.4% catastrophic outliers and small (-0.5%) residual bias. For bluer galaxies up to the same redshift, the residual bias (on average -0.5%) trend, percentage of catastrophic failures (1.2%), and precision (4.2%) are higher, but still interestingly small for many science applications. Good photometric redshifts (to 5%) can be obtained for at most 60% of the QSOs of the sample. PCS will create a value-added catalog with classifications and photometric redshifts for eventually many millions of sources.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-R-05: Multidimensional Imaging Radiomics-Geodesics: A Novel Manifold Learning Based Automatic Feature Extraction Method for Diagnostic Prediction in Multiparametric Imaging

Purpose: Multiparametric radiological imaging is used for diagnosis in patients. Potentially extracting useful features specific to a patient’s pathology would be crucial step towards personalized medicine and assessing treatment options. In order to automatically extract features directly from multiparametric radiological imaging datasets, we developed an advanced unsupervised machine learning algorithm called the multidimensional imaging radiomics-geodesics(MIRaGe). Methods: Seventy-six breast tumor patients underwent 3T MRI breast imaging were used for this study. We tested the MIRaGe algorithm to extract features for classification of breast tumors into benign or malignant. The MRI parameters used were T1-weighted, T2-weighted, dynamic contrast enhanced MR imaging (DCE-MRI) and diffusion weighted imaging(DWI). The MIRaGe algorithm extracted the radiomics-geodesics features (RGFs) from multiparametric MRI datasets. This enable our method to learn the intrinsic manifold representations corresponding to the patients. To determine the informative RGF, a modified Isomap algorithm(t-Isomap) was created for a radiomics-geodesics feature space(tRGFS) to avoid overfitting. Final classification was performed using SVM. The predictive power of the RGFs was tested and validated using k-fold cross validation. Results: The RGFs extracted by the MIRaGe algorithm successfully classified malignant lesions from benign lesions with a sensitivity of 93% and a specificity of 91%. The top 50 RGFs identified as the most predictive by the t-Isomap procedure were consistent with the radiological parameters known to be associated with breast cancer diagnosis and were categorized as kinetic curve characterizing RGFs, wash-in rate characterizing RGFs, wash-out rate characterizing RGFs and morphology characterizing RGFs. Conclusion: In this paper, we developed a novel feature extraction algorithm for multiparametric radiological imaging. The results demonstrated the power of the MIRaGe algorithm at automatically discovering useful feature representations directly from the raw multiparametric MRI data. In conclusion, the MIRaGe informatics model provides a powerful tool with applicability in cancer diagnosis and a possibility of extension to other kinds of pathologies. NIH (P50CA103175, 5P30CA006973 (IRAT), R01CA190299, U01CA140204), Siemens Medical Systems (JHU-2012-MR-86-01) and Nivida Graphics Corporation.

60 APPLIED LIFE SCIENCES↗

Seed classification with random forest models

Premise: To improve forest conservation monitoring, we developed a protocol to automatically count and identify the seeds of plant species with minimal resource requirements, making the process more efficient and less dependent on human operators. Methods and Results: Seeds from six North American conifer tree species were separated from leaf litter and imaged on a flatbed scanner. In the most successful species-classification approach, an ImageJ macro automatically extracted measurements for random forest classification in the software R. The method allows for good classification accuracy, and the same process can be used to train the model on other species. Conclusions: This protocol is an adaptable tool for efficient and consistent identification of seed species or potentially other objects. Automated seed classification is efficient and inexpensive, making it a practical solution that enhances the feasibility of large-scale monitoring projects in conservation biology.

59 BASIC BIOLOGICAL SCIENCES↗

Automated Morphological and Morphometric Analysis of Mass Spectrometry Imaging Data: Application to Biomarker Discovery

Mass spectrometry imaging datasets are mostly analyzed in terms of average intensity in regions of interest. However, biological tissues have different morphologies with several sizes, shapes, and structures. The important biological information, contained in this highly heterogeneous cellular organization, could be hidden by analyzing the average intensities. Finding an analytical process of morphology would help to find such information, describe tissue model, and support identification of biomarkers. This study describes an informatics approach for the extraction and identification of mass spectrometry image features and its application to sample analysis and modeling. For the proof of concept, two different tissue types (healthy kidney and CT-26 xenograft tumor tissues) were imaged and analyzed. A mouse kidney model and tumor model were generated using morphometric – number of objects and total surface – information. The morphometric information was used to identify m/z that have a heterogeneous distribution. It seems to be a worthwhile pursuit as clonal heterogeneity in a tumor is of clinical relevance. This study provides a new approach to find biomarker or support tissue classification with more information. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SDSS IV MaNGA: visual morphological and statistical characterization of the DR15 sample

ABSTRACT We present a detailed visual morphological classification for the 4614 MaNGA galaxies in SDSS Data Release 15, using image mosaics generated from a combination of r band (SDSS and deeper DESI Legacy Surveys) images and their digital post-processing. We distinguish 13 Hubble types and identify the presence of bars and bright tidal debris. After correcting the MaNGA sample for volume completeness, we calculate the morphological fractions, the bi-variate distribution of type and stellar mass M* – where we recognize a morphological transition ‘valley’ around S0a-Sa types – and the variations of the g − i colour and luminosity-weighted age over this distribution. We identified bars in 46.8 per cent of galaxies, present in all Hubble types later than S0. This fraction amounts to a factor ∼2 larger when compared with other works for samples in common. We detected 14 per cent of galaxies with tidal features, with the fraction changing with M* and morphology. For 355 galaxies, the classification was uncertain; they are visually faint, mostly of low/intermediate masses, low concentrations, and discy in nature. Our morphological classification agrees well with other works for samples in common, though some particular differences emerge, showing that our image procedures allow us to identify a wealth of added value information as compared to SDSS-based previous estimates. Based on our classification, we also propose an alternative criteria for the E–S0 separation, in the structural semimajor to semiminor axis versus bulge to total light ratio (b/a − B/T) and concentration versus semimajor to semiminor axis (C − b/a) space.

Vázquez-Mata, J. A. (ORCID:0000000186941204)↗

Characteristics Associated with Pathologic Nodal Burden in Patients Presenting with Clinical Melanoma Nodal Metastasis

Background: Nodal observation is safe for patients with microscopic melanoma metastasis in a sentinel lymph node (LN). Complete LN dissection (CLND) remains the standard of care for patients with clinically evident LN (cLN) metastases, even though about 40% have only one pathologic LN (pLN). We sought to identify clinical features associated with having one pLN among patients with cLNs. Methods: Patients at three melanoma centers who underwent CLND for cLNs were identified. Clinicopathologic and imaging characteristics associated with one pLN were determined by multivariable logistic regression and classification tree analysis. Results: Of 190 patients, 90 (47.4%) had one pLN and 100 (52.6%) had more than one pLN. By multivariable logistic regression, extremity versus truncal primary (odds ratio [OR] 2.15, p = 0.012), axillary versus superficial inguinal location (OR 3.89, p = 0.009), and preoperative cross-sectional imaging demonstrating more than one versus one cLN (OR 17.1, p < 0.001) were associated with more than one pLN. The negative predictive value for additional pathologic nodal disease of preoperative imaging was 70.9%, increasing to 74.4% for positron emission tomography/computed tomography. In the subgroup of patients with one cLN, the classification tree identified two groups with < 10% risk of additional pLNs: (1) Breslow thickness > 6.55 mm (n = 17); and (2) if unknown primary or Breslow thickness ≤ 6.55 mm, then LN diameter > 1.8 cm in the inguinal location (n = 22). Conclusion: The majority of patients with one cLN from melanoma by preoperative imaging will harbor no additional pathologic nodes on CLND. Safety of nodal observation after clinical nodal excision in these patients, particularly in an era of effective adjuvant therapies, deserves prospective evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Herbig-haro objects and mid-infrared outflows in the VELA C molecular cloud

We have performed a deep [S II] λλ6717/6731 wide field Herbig-Haro (HH) object survey toward the Vela C molecular cloud with a sky coverage of about 2 deg{sup 2}. In total, 18 new HH objects, HH 1090-1107, are discovered and the two previously known HH objects, HH 73-74, are also detected in our [S II] images. We also present an investigation of mid-infrared outflows in the Vela C molecular cloud using the Wide-field Infrared Survey Explorer images taken from AllWISE data release. Using the method suggested by Zhang and Wang, 11 extended green objects (EGOs) are identified to be the mid-infrared outflows, including 6 new mid-infrared outflows that have not been detected previously at other wavelengths and 5 mid-infrared counterparts of the HH objects detected in this work. Using the AllWISE Source Catalog and the source classification scheme suggested by Koenig et al., we have identified 56 young stellar object (YSO) candidates in the Vela C molecular cloud. The possible driving sources of the HH objects and EGOs are discussed based on the morphology of HH objects and EGOs and the locations of HH objects, EGOs and YSO candidates. Finally we associate 12 HH objects and 5 EGOs with 10 YSOs and YSO candidates. The median length of the outflows in Vela C is 0.35 pc and the outflows seem to be oriented randomly.

79 ASTRONOMY AND ASTROPHYSICS↗

Unmixing hyperspectral images using Markov random fields

This paper proposes a new spectral unmixing strategy based on the normal compositional model that exploits the spatial correlations between the image pixels. The pure materials (referred to as endmembers) contained in the image are assumed to be available (they can be obtained by using an appropriate endmember extraction algorithm), while the corresponding fractions (referred to as abundances) are estimated by the proposed algorithm. Due to physical constraints, the abundances have to satisfy positivity and sum-to-one constraints. The image is divided into homogeneous distinct regions having the same statistical properties for the abundance coefficients. The spatial dependencies within each class are modeled thanks to Potts-Markov random fields. Within a Bayesian framework, prior distributions for the abundances and the associated hyperparameters are introduced. A reparametrization of the abundance coefficients is proposed to handle the physical constraints (positivity and sum-to-one) inherent to hyperspectral imagery. The parameters (abundances), hyperparameters (abundance mean and variance for each class) and the classification map indicating the classes of all pixels in the image are inferred from the resulting joint posterior distribution. To overcome the complexity of the joint posterior distribution, Markov chain Monte Carlo methods are used to generate samples asymptotically distributed according to the joint posterior of interest. Simulations conducted on synthetic and real data are presented to illustrate the performance of the proposed algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RINGFINDER: Automated detection of galaxy-scale gravitational lenses in ground-based multi-filter imaging data

We present RINGFINDER, a tool for finding galaxy-scale strong gravitational lenses in multi-band imaging data. By construction, the method is sensitive to configurations involving a massive foreground ETG and a faint, background, blue source. RINGFINDER detects the presence of blue residuals embedded in an otherwise smooth red light distribution by difference imaging in two bands. The method is automated for efficient application to current and future surveys, having originally been designed for the 150 deg{sup 2} Canada-France-Hawaii Telescope Legacy Survey (CFHTLS). We describe each of the steps of RINGFINDER. We then carry out extensive simulations to assess completeness and purity. For sources with magnification μ > 4, RINGFINDER reaches 42% (25%) completeness and 29% (86%) purity before (after) visual inspection. The completeness of RINGFINDER is substantially improved in the particular range of Einstein radii 0.''8 ≤ R {sub Ein} ≤ 2.''0 and lensed images brighter than g = 22.5, where it can be as high as ∼70%. RINGFINDER does not introduce any significant bias in the source or deflector population. We conclude by presenting the final catalog of RINGFINDER CFHTLS galaxy-scale strong lens candidates. Additional information obtained with Hubble Space Telescope and Keck adaptive optics high-resolution imaging, and with Keck and Very Large Telescope spectroscopy, is used to assess the validity of our classification and measure the redshift of the foreground and the background objects. From an initial sample of 640,000 ETGs, RINGFINDER returns 2500 candidates, which we further reduce by visual inspection to 330 candidates. We confirm 33 new gravitational lenses from the main sample of candidates, plus an additional 16 systems taken from earlier versions of RINGFINDER. First applications are presented in the Strong Lensing Legacy Survey galaxy-scale lens sample paper series.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification of Metal Stresses in Arabidopsis thaliana Using Hyperspectral Reflectance Imaging

Industrial accidents, such as the Fukushima and Chernobyl disasters, release harmful chemicals into the environment, covering large geographical areas. Natural flora may serve as biological sensors for detecting metal contamination, such as cesium. Spectral detection of plant stresses typically employs a few select wavelengths and often cannot distinguish between different stress phenotypes. In this study, we apply hyperspectral reflectance imaging in the visible and near-infrared along with multivariate curve resolution (MCR) analysis to identify unique spectral signatures of three stresses in Arabidopsis thaliana : salt, copper, and cesium. While all stress conditions result in common stress physiology, hyperspectral reflectance imaging and MCR analysis produced unique spectral signatures that enabled classification of each stress. As the level of potassium was previously shown to affect cesium stress in plants, the response of A. thaliana to cesium stress under variable levels of potassium was also investigated. Increased levels of potassium reduced the spectral response of A. thaliana to cesium and prevented changes to chloroplast cellular organization. While metal stress mechanisms may vary under different environmental conditions, this study demonstrates that hyperspectral reflectance imaging with MCR analysis can distinguish metal stress phenotypes, providing the potential to detect metal contamination across large geographical areas.

multivariate curve resolution↗

Unsupervised classification for region of interest in X-ray ptychography

X-ray ptychography offers high-resolution imaging of large areas at a high computational cost due to the large volume of data provided. To address the cost issue, we propose a physics-informed unsupervised classification algorithm that is performed prior to reconstruction and removes data outside the region of interest (RoI) based on the multimodal features present in the diffraction patterns. The preprocessing time for the proposed method is inconsequential in contrast to the resource-intensive reconstruction process, leading to an impressive reduction in the data workload to a mere 20% of the initial dataset. This capability consequently reduces computational time dramatically while preserving reconstruction quality. Through further segmentation of the diffraction patterns, our proposed approach can also detect features that are smaller than beam size and correctly classify them as within the RoI.

97 MATHEMATICS AND COMPUTING↗

Weakly supervised classification of aortic valve malformations using unlabeled cardiac MRI sequences

Biomedical repositories such as the UK Biobank provide increasing access to prospectively collected cardiac imaging, however these data are unlabeled, which creates barriers to their use in supervised machine learning. We develop a weakly supervised deep learning model for classification of aortic valve malformations using up to 4,000 unlabeled cardiac MRI sequences. Instead of requiring highly curated training data, weak supervision relies on noisy heuristics defined by domain experts to programmatically generate large-scale, imperfect training labels. For aortic valve classification, models trained with imperfect labels substantially outperform a supervised model trained on hand-labeled MRIs. In an orthogonal validation experiment using health outcomes data, our model identifies individuals with a 1.8-fold increase in risk of a major adverse cardiac event. This work formalizes a deep learning baseline for aortic valve classification and outlines a general strategy for using weak supervision to train machine learning models using unlabeled medical images at scale.

60 APPLIED LIFE SCIENCES↗