Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hot spring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Field Testing of an Unvented Roof with Fibrous Insulation, Tiles and Vapor Diffusion Venting

This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates

BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates - Bolingbrook, IL 60440 BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates - Friendswood, TX 77546 To understand the long-term moisture performance of unvented roof assemblies with fibrous insulation, the U.S. Department of Energy's Building America team Building Science Corporation built and monitored test roofs in two climates: a cold-climate test house in Bolingbrook, Illinois (Chicago area; zone 5A), and a hot-humid test house in Friendswood, Texas (Houston area, zone 2A). The Chicago-area test bed had seven parallel experimental rafter bays. The assemblies included a control vented compact (cathedral) roof, a dense-pack cellulose unvented roof, and an unvented roof with a "diffusion vent" (a strip of vapor-permeable gypsum sheathing at the ridge to allow drying). The interior finish was gypsum wallboard (GWB) with latex paint. The other four bays were top vent roof assemblies, which have a polypropylene breather mesh between the roof sheathing and the asphalt shingles to allow ventilation drying of the assembly from underneath the vapor-impermeable shingles. Two of the four "top vent" roofs were fiberglass batt and two were dense-pack cellulose roofs with either interior GWB or open to the interior. Wintertime moisture-related failure was accelerated by providing interior humidification (22.2 degree C [72 degree F]/50% relative humidity [RH]), which is known to be an extreme interior loading). Data were captured over 8 months, including a winter and the following spring and early summer.

Array↗

Oregon Cascades Play Fairway Analysis: Maps

The maps in this submission include: heat flow, alkalinity, Cl, Mg, SiO2, Quaternary volcanic rocks, faults, and land ownership. All of the Oregon Cascade region. The work was done by John Trimble, in 2015, at Oregon State University.

15 GEOTHERMAL ENERGY↗

Atlas V Launch Incorporated NASA Glenn Thermal Barrier

In the Spring of 2002, Aerojet experienced a major failure during a qualification test of the solid rocket motor that they were developing for the Atlas V Enhanced Expendable Launch Vehicle. In that test, hot combustion gas reached the O-rings in the nozzle-to-case joint and caused a structural failure that resulted in loss of the nozzle and aft dome sections of the motor. To improve the design of this joint, Aerojet decided to incorporate three braided carbon-fiber thermal barriers developed at the NASA Glenn Research Center. The thermal barriers were used to block the searing-hot 5500 F pressurized gases from reaching the temperature-sensitive O-rings that seal the joint. Glenn originally developed the thermal barriers for the nozzle joints of the space shuttle solid rocket motors, and Aerojet decided to use them on the basis of the results of several successful ground tests of the thermal barriers in the shuttle rockets. Aerojet undertook an aggressive schedule to redesign the rocket nozzle-to-case joint with the thermal barriers and to qualify it in time for a launch planned for the middle of 2003. They performed two successful qualification tests (Oct. and Dec. 2002) in which the Glenn thermal barriers effectively protected the O-rings. These qualification tests saved hundreds of thousands of dollars in development costs and put the Lockheed-Martin/Aerojet team back on schedule. On July 17, 2003, the first flight of an Atlas V boosted with solid rocket motors successfully launched a commercial satellite into orbit from Cape Canaveral Air Force Station. Aero-jet's two 67-ft solid rocket boosters performed flawlessly, with each providing thrust in excess of 250,000 lbf. Both motors incorporated three Glenn-developed thermal barriers in their nozzle-to-case joints. The Cablevision satellite launched on this mission will be used to provide direct-to-home satellite television programming for the U.S. market starting in late 2003. The Atlas V is a product of the military's Enhanced Expendable Launch Vehicle program designed to provide assured military access to space. It can lift payloads up to 19,100 lb to geosynchronous transfer orbit and was designed to meet Department of Defense, commercial, and NASA needs. The Atlas V and Delta IV are two launch systems being considered by NASA to launch the Orbital Space Plane/Crew Exploration Vehicle. The launch and rocket costs of this mission are valued at $250 million. Successful application of the Glenn thermal barrier to the Atlas V program was an enormous breakthrough for the program's technical and schedule success.

Dunlap, Patrick H., Jr.↗

River stage influences on uranium transport in a hydrologically dynamic groundwater-surface water transition zone

In this study, a well-field within a uranium (U) plume in the groundwater-surface water transition zone was monitored for a 3 year period for water table elevation and dissolved solutes. The plume discharges to the Columbia River, which displays a dramatic spring stage surge resulting from snowmelt. Groundwater exhibits a low hydrologic gradient and chemical differences with river water. River water intrudes the site in spring. Specific aims were to assess the impacts of river intrusion on dissolved uranium (U aq ), specific conductance (SpC), and other solutes, and to discriminate between transport, geochemical, and source term heterogeneity effects. Time series trends for U aq and SpC were complex and displayed large temporal and well-to-well variability as a result of water table elevation fluctuations, river water intrusion, and changes in groundwater flow directions. The wells were clustered into subsets exhibiting common behaviors resulting from the intrusion dynamics of river water and the location of source terms. Hot-spots in U aq varied in location with increasing water table elevation through the combined effects of advection and source term location. Heuristic reactive transport modeling with PFLOTRAN demonstrated that mobilized U aq was transported between wells and source terms in complex trajectories, and was diluted as river water entered and exited the groundwater system. While U aq time-series concentration trends varied significantly from year-to-year as a result of climate-caused differences in the spring hydrograph, common and partly predictable response patterns were observed that were driven by water table elevation, and the extent and duration of river water intrusion.

54 ENVIRONMENTAL SCIENCES↗

THE LUPUS TRANSIT SURVEY FOR HOT JUPITERS: RESULTS AND LESSONS

We present the results of a deep, wide-field transit survey targeting 'Hot Jupiter' planets in the Lupus region of the Galactic plane conducted over 53 nights concentrated in two epochs separated by a year. Using the Australian National University 40-inch telescope at Siding Spring Observatory (SSO), the survey covered a 0.66 deg{sup 2} region close to the Galactic plane (b = 11{sup 0}) and monitored a total of 110,372 stars (15.0 {<=} V {<=} 22.0). Using difference imaging photometry, 16,134 light curves with a photometric precision of {sigma} < 0.025 mag were obtained. These light curves were searched for transits, and four candidates were detected that displayed low-amplitude variability consistent with a transiting giant planet. Further investigations, including spectral typing and radial velocity measurements for some candidates, revealed that of the four, one is a true planetary companion (Lupus-TR-3), two are blended systems (Lupus-TR-1 and 4), and one is a binary (Lupus-TR-2). The results of this successful survey are instructive for optimizing the observational strategy and follow-up procedure for deep searches for transiting planets, including an upcoming survey using the SkyMapper telescope at SSO.

79 ASTRONOMY AND ASTROPHYSICS↗

Shallow snowpack inhibits soil respiration in sagebrush steppe through multiple biotic and abiotic mechanisms

Abstract In sagebrush steppe, snowpack may govern soil respiration through its effect on multiple abiotic and biotic factors. Across the Intermountain West of the United States, snowpack has been declining for decades and is projected to decline further over the next century, making the response of soil respiration to snowpack a potentially important factor in the ecosystem carbon cycle. In this study, we evaluated the direct and indirect roles of the snowpack in driving soil respiration in sagebrush steppe ecosystems by taking advantage of highway snowfences in Wyoming to manipulate snowpack. An important contribution of this study is the use of Bayesian modeling to quantify the effects of soil moisture and temperature on soil respiration across a wide range of conditions from frozen to hot and dry, while simultaneously accounting for biotic factors (e.g., vegetation cover, root density, and microbial biomass and substrate‐use diversity) affected by snowpack. Elevated snow depth increased soil temperature (in the winter) and moisture (winter and spring), and was associated with reduced vegetation cover and microbial biomass carbon. Soil respiration showed an exponential increase with temperature, with a temperature sensitivity that decreased with increasing seasonal temperature ( Q 10 = 4.3 [winter], 2.3 [spring], and 1.7 [summer]); frozen soils were associated with unrealistic Q 10 ≈ 7989 due to the liquid‐to‐ice transition of soil water. Soil respiration was sensitive to soil water content; predicted respiration under very dry conditions was less than 10% of respiration under moist conditions. While higher vegetation cover increased soil respiration, this was not due to increased root density, and may reflect differences in litter inputs. Microbial substrate‐use diversity was negatively related to reference respiration (i.e., respiration rate at a reference temperature and optimal soil moisture), although the mechanism remains unclear. This study indicates that soil respiration is inhibited by shallow snowpack through multiple mechanisms; thus, future decreases in snowpack across the sagebrush steppe have the potential to reduce losses of soil C, potentially affecting regional carbon balance.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling Climate-Biosphere Interactions in the Boreal Forest

The overall goal of this BOREAS Program was to develop, test, and apply a model of the carbon balance of boreal forest sites with a significant groundcover component (moss or lichen). The basic question addressed with this model was: What is the sensitivity of the boreal forest carbon balance to weather variability? More specifically: What are the differences in the sensitivities of carbon gains (photosynthesis) and carbon losses (respiration) of the various components of the ecosystem? Are there different seasonalities to their sensitivities (e.g., warmer springs will have one effect, warmer summers a different effect)? What are the effects of different patterns of successive weather years (wet/dry, warm/cool)? What, for example, would be the difference in effects of two "warmer than normal" months-one with each day warmer than normal, and the other with three normal weeks and one very hot week? Due to weather variability, how "noisy" will any carbon flux or carbon pool signal be that we might use to try to detect change? The project resulted in the development of a new boreal forest ecosystem model. This model was the first model in the BOREAS project to look closely at the role of mosses in the ecosystem carbon balance, and also was the first model in the BOREAS project to look closely at interannual variability in carbon fluxes. Along with the work of many other groups, TE-19 modeling analysis pointed to the need for a second, longer field season in 1996, with particular focus on the spring and fall transitions and on ground vegetation. BOREAS groups TE-19 (Frolking), TGB-1 (Crill) & TGB-3 (Moore & Roulet) analyzed BOREAS data and other published and unpublished data to develop a relationship between peatland ecosystem productivity and incoming radiation, which is quite distinct from the upland ecosystem relationships observed in other studies.

Frolking, Steve↗

Shape memory alloy heat engines and energy harvesting systems

A heat engine includes a first rotatable pulley and a second rotatable pulled spaced from the first rotatable pulley. A shape memory alloy (SMA) element is disposed about respective portions of the pulleys at an SMA pulley ratio. The SMA element includes first spring coil and a first fiber core within the first spring coil. A timing cable is disposed about disposed about respective portions of the pulleys at a timing pulley ratio, which is different than the SMA pulley ratio. The SMA element converts a thermal energy gradient between the hot region and the cold region into mechanical energy.

42 ENGINEERING↗

Building America Case Study: Solar Water Heating in Multifamily Buildings

Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2.) Because of better scale, SDHW systems in multifamily buildings cost significantly less per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support form the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.

Building America↗

A new approach to modeling temperature-related mortality: Non-linear autoregressive models with exogenous input

Highlights: • NARX models are established in other environmental research, but are unused in temperature-related mortality research. • NARX models do not assume any particular shape to the temperature-mortality association. • NARX models are cross-validated and are easily modified to take on real-time, multi-step-ahead predictions and hindcasts. • Year-round, daily mortality in 41 different US cities was modeled using an ensemble of NARX models in each location. • Models show skill everywhere. Results vary spatially and seasonally, improving upon a persistence model by 17% points. • When compared with distributed lag non-linear models, the output time series are largely similar Temperature-mortality relationships are nonlinear, time-lagged, and can vary depending on the time of year and geographic location, all of which limits the applicability of simple regression models in describing these associations. This research demonstrates the utility of an alternative method for modeling such complex relationships that has gained recent traction in other environmental fields: nonlinear autoregressive models with exogenous input (NARX models). All-cause mortality data and multiple temperature-based data sets were gathered from 41 different US cities, for the period 1975–2010, and subjected to ensemble NARX modeling. Models generally performed better in larger cities and during the winter season. Across the US, median absolute percentage errors were 10% (ranging from 4% to 15% in various cities), the average improvement in the r-squared over that of a simple persistence model was 17% (6–24%), and the hit rate for modeling spike days in mortality (>80th percentile) was 54% (34–71%). Mortality responded acutely to hot summer days, peaking at 0–2 days of lag before dropping precipitously, and there was an extended mortality response to cold winter days, peaking at 2–4 days of lag and dropping slowly and continuing for multiple weeks. Spring and autumn showed both of the aforementioned temperature-mortality relationships, but generally to a lesser magnitude than what was seen in summer or winter. When compared to distributed lag nonlinear models, NARX model output was nearly identical. These results highlight the applicability of NARX models for use in modeling complex and time-dependent relationships for various applications in epidemiology and environmental sciences.

54 ENVIRONMENTAL SCIENCES↗

High-Temperature Knitted Spring Tubes Improved for Structural Seal Applications

To meet the needs of current and future space vehicles, the NASA Glenn Research Center is developing advanced control surface seals. These seals are used to fill the gaps surrounding actuated structures, such as rudders and body flaps, to shield underlying lower temperature structures, such as mechanical actuators, from the hot gases encountered during atmospheric reentry. During previous testing, the current baseline seal design, which is used on the space shuttle as a thermal barrier and was selected as the rudder-fin seal on the X-38 crew return vehicle, exhibited significant permanent set following compression at 1900 F (see the following photograph). Decreased resiliency (springback) could prevent the seal from contacting both of the opposing sealing surfaces and allow the ingestion of damaging hot gases during reentry, which could have detrimental effects on vehicle subsystems.

Dunlap, Patrick H.↗

Thermal, water, and land cover factors led to contrasting urban and rural vegetation resilience to extreme hot months

Abstract With continuing global warming and urbanization, it is increasingly important to understand the resilience of urban vegetation to extreme high temperatures, but few studies have examined urban vegetation at large scale or both concurrent and delayed responses. In this study, we performed an urban–rural comparison using the Enhanced Vegetation Index and months that exceed the historical 90th percentile in mean temperature (referred to as “hot months”) across 85 major cities in the contiguous United States. We found that hot months initially enhanced vegetation greenness but could cause a decline afterwards, especially for persistent (≥4 months) and intense (≥+2 °C) episodes in summer. The urban responses were more positive than rural in the western United States or in winter, but more negative during spring–autumn in the eastern United States. The east–west difference can be attributed to the higher optimal growth temperatures and lower water stress levels of the western urban vegetation than the rural. The urban responses also had smaller magnitudes than the rural responses, especially in deciduous forest biomes, and least in evergreen forest biomes. Within each biome, analysis at 1 km pixel level showed that impervious fraction and vegetation cover, local urban heat island intensity, and water stress were the key drivers of urban–rural differences. These findings advance our understanding of how prolonged exposure to warm extremes, particularly within urban environments, affects vegetation greenness and vitality. Urban planners and ecosystem managers should prioritize the long and intense events and the key drivers in fostering urban vegetation resilience to heat waves.

54 ENVIRONMENTAL SCIENCES↗

Advanced Control Surface Seal Development for Future Space Vehicles

NASA s Glenn Research Center (GRC) has been developing advanced high temperature structural seals since the late 1980's and is currently developing seals for future space vehicles as part of the Next Generation Launch Technology (NGLT) program. This includes control surface seals that seal the edges and hinge lines of movable flaps and elevons on future reentry vehicles. In these applications, the seals must operate at temperatures above 2000 F in an oxidizing environment, limit hot gas leakage to protect underlying structures, endure high temperature scrubbing against rough surfaces, and remain flexible and resilient enough to stay in contact with sealing surfaces for multiple heating and loading cycles. For this study, three seal designs were compared against the baseline spring tube seal through a series of compression tests at room temperature and 2000 F and flow tests at room temperature. In addition, canted coil springs were tested as preloaders behind the seals at room temperature to assess their potential for improving resiliency. Addition of these preloader elements resulted in significant increases in resiliency compared to the seals by themselves and surpassed the performance of the baseline seal at room temperature. Flow tests demonstrated that the seal candidates with engineered cores had lower leakage rates than the baseline spring tube design. However, when the seals were placed on the preloader elements, the flow rates were higher as the seals were not compressed as much and therefore were not able to fill the groove as well. High temperature tests were also conducted to asses the compatibility of seal fabrics against ceramic matrix composite (CMC) panels anticipated for use in next generation launch vehicles. These evaluations demonstrated potential bonding issues between the Nextel fabrics and CMC candidates.

DeMange, J. J.↗

Advanced Control Surface Seal Development for Future Space Vehicles

NASA's Glenn Research Center (GRC) has been developing advanced high temperature structural seals since the late 1980s and is currently developing seals for future space vehicles as part of the Next Generation Launch Technology (NGLT) program. This includes control surface seals that seal the edges and hinge lines of movable flaps and elevons on future reentry vehicles. In these applications, the seals must operate at temperatures above 2000 F in an oxidizing environment, limit hot gas leakage to protect underlying structures, endure high temperature scrubbing against rough surfaces, and remain flexible and resilient enough to stay in contact with sealing surfaces for multiple heating and loading cycles. For this study, three seal designs were compared against the baseline spring tube seal through a series of compression tests at room temperature and 2000 F and flow tests at room temperature. In addition, canted coil springs were tested as preloaders behind the seals at room temperature to assess their potential for improving resiliency. Addition of these preloader elements resulted in significant increases in resiliency compared to seals by themselves and surpassed the performance of the baseline seal at room temperature. Flow tests demonstrated that the seal candidates with engineered cores had lower leakage rates than the baseline spring tube design. However, then the seals were placed on the preloader elements, the flow rates were higher as the seals were not compressed as much and therefore were not able to fill the groove as well. High temperature tests were also conducted to assess the compatability of seal fabrics against cermaic matrix composite (CMC) panels anticipated for use in next generation launch vehicles. These evaluations demonstrated potential bonding issues between the Nextel fabrics and CMC candidates.

DeMange, Jeffrey J.↗

Building America Case Study: Solar Water Heating in Multifamily Buildings, Greenfield, Massachusetts

Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2) Because of better scale, SDHW systems in multifamily buildings cost significantly less per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temperature and pressure determinations in the Venus atmosphere by means of high-resolution spectra from 1 to 2.5 microns

Twenty-one bands of CO2 and the 2-0 band of CO were analyzed for best temperature and pressure fits from Venus spectra obtained with the 'Connes' interferometer at the Steward Observatory 2.25-m telescope during the spring of 1971. An average temperature of 241 plus or minus 7 K, an effective pressure of 0.12 plus or minus 0.06 atm, and an average two-way transmission abundance of 3 km-amagat were determined. No difference in temperature or pressure between hot bands, a double hot band, and regular bands was found. The results indicate that, most likely, spectroscopic line formation occurs in a relatively clear space above a scattering cloud layer with a reasonably well-defined upper boundary.

Dierenfeldt, K. E.↗

Linear thermomagnetic energy harvester for low-grade thermal energy harvesting

Low-grade thermal energy, either from waste heat or from natural resources, constitutes an enormous energy reserve that remains to be fully harvested. Harvesting low-grade heat is challenging because of the low Carnot efficiency. Among various thermal energy harvesting mechanisms available for capturing low-grade heat (temperature less than 100 degrees C), the thermomagnetic effect has been found to be quite promising. In this study, we demonstrate a scalable thermomagnetic energy harvester architecture that exhibits 140% higher power density compared to the previously published spring-mass designs. The alternating force required to oscillate the thermomagnetic mass is generated through the interaction between two magnetic forces in opposite directions. We employed numerical modeling to illustrate the behavior of a thermomagnetic device under different operating conditions and to obtain the optimal hot-side and cold-side temperatures for continuous mode operations. A miniaturized thermomagnetic harvester was fabricated and experiments were conducted to systematically evaluate the performance. The prototype was found to exhibit an oscillation frequency of 0.33 Hz, a work output of 0.6 J/kg/cycle, and a power density of 0.2 W/kg of gadolinium under the temperature difference of 60 K.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗