Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Field Evaluation of Highly Insulating Windows in the Lab Homes: Winter Experiment

This field evaluation of highly insulating windows was undertaken in a matched pair of 'Lab Homes' located on the Pacific Northwest National Laboratory (PNNL) campus during the 2012 winter heating season. Improving the insulation and solar heat gain characteristics of a home's windows has the potential to significantly improve the home's building envelope and overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high quality installation and/or window retrofit will also minimize or reduce air leakage through the window cavity and thus also contribute to reduced heat loss in the winter and cooling loss in the summer. These improvements all contribute to decreasing overall annual home energy use. Occupant comfort (non-quantifiable) can also be increased by minimizing or eliminating the cold 'draft' (temperature) many residents experience at or near window surfaces that are at a noticeably lower temperature than the room air temperature. Lastly, although not measured in this experiment, highly insulating windows (triple-pane in this experiment) also have the potential to significantly reduce the noise transmittance through windows compared to standard double-pane windows. The metered data taken in the Lab Homes and data analysis presented here represent 70 days of data taken during the 2012 heating season. As such, the savings from highly insulating windows in the experimental home (Lab Home B) compared to the standard double-pane clear glass windows in the baseline home (Lab Home A) are only a portion of the energy savings expected from a year-long experiment that would include a cooling season. The cooling season experiment will take place in the homes in the summer of 2012, and results of that experiment will be reported in a subsequent report available to all stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of the Manufactured Home Energy Audit (MHEA)

The Manufactured Home Energy Audit (MHEA) is an energy audit tool designed specifically to identify recommended weatherization measures for mobile homes as part of the U.S. Department of Energy's (DOE's) Weatherization Assistance Program. A field validation of MHEA was performed using billing/delivery data collected on 86 mobile homes heated primarily by electricity, natural gas, or propane to assess the audit's accuracy and the validity of its recommendations. The validation found that MHEA overpredicts the annual space-heating energy savings of weatherization measures to be installed in mobile homes, which leads to low realization rates, primarily because of its large overprediction of annual pre-weatherization space-heating energy consumption. However, MHEA's annual space-heating energy savings estimates and realization rates can be improved considerably using MHEA's built-in billing adjustment feature. In order to improve the accuracy of MHEA's annual space-heating energy savings estimates and realization rate, the cause of MHEA's overprediction of annual pre-weatherization space-heating energy consumption needs to be further investigated and corrected. Although MHEA's billing adjustment feature improved MHEA's annual space-heating energy savings estimates, alternative methods of making the correction that may provide improved performance should be investigated. In the interim period before permanent improvements to MHEA can be made, the following recommendations should be followed: (a) do not enter into MHEA insulation thicknesses of 1 in. or less and especially zero (0 in.) unless such low levels have been verified through visual inspection of several parts of the envelope area in question; (b) use MHEA's billing adjustment feature to develop a list of recommended measures based on adjusted energy savings if possible, especially in mobile homes that have several major energy deficiencies; and (c) do not use MHEA's "evaluate duct sealing" option at this time (although certainly seal all duct leaks and use diagnostics as appropriate to find leakage sites and quantify improvements).

03 NATURAL GAS↗

Validating Savings Claims of Cold Climate Zero Energy Ready Homes

This study was intended to validate actual performance of three ZERHs in the Northeast to energy models created in REM/Rate v14.5 (one of the certified software programs used to generate a HERS Index) and the National Renewable Energy Laboratory’s Building Energy Optimization (BEopt™) v2.3 E+ (a more sophisticated hourly energy simulation software). This report details the validation methods used to analyze energy consumption at each home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Healthy Efficient New Gas Homes (HENGH) Pilot Test Results

The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The other home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Model Development for Retrofit Homes

Based on previous research conducted by Pacific Northwest National Laboratory and Florida Solar Energy Center providing technical assistance to implement 23 deep energy retrofits across the nation, six homes were selected in Florida and Texas for detailed post-retrofit energy modeling to assess realized energy savings (Chandra et al, 2012). Of these homes, three homes in San Antonio were selected for detailed analysis of post-retrofit energy use and realized energy savings. The actual savings achieved in these homes post-retrofit, as determined by a utility bill comparison, is presented. For the three metered homes in Florida, no pre-retrofit utility bills are available, so a utility bill comparison to determine realized savings is not possible. Assessing realized savings can be difficult for some homes where pre-retrofit occupancy and energy performance are unknown. Initially, savings had been estimated using a HERS Index comparison for these homes. However, this does not account for confounding factors such as occupancy and weather. This research also addresses a method to more reliably assess energy savings achieved in deep energy retrofits for which pre-retrofit utility bills or occupancy information is not available.

energy efficiency↗

Low-E Storm Windows Gain Acceptance as a Home Weatherization Measure

This article for Home Energy Magazine describes work by the U.S. Department of Energy to develop low-emissivity storm windows as an energy efficiency-retrofit option for existing homes. The article describes the low-emissivity invisible silver metal coatings on the glass, which reflect heat back into the home in winter or back outside in summer and the benefits of low-e storm windows including insulation, air sealing, noise blocking, protection of antique windows, etc. The article also describes Pacific Northwest National Laboratory's efforts on behalf of DOE to overcome market barriers to adoption of the technology, including performance validation studies in the PNNL Lab Homes, cost effectiveness analysis, production of reports, brochures, how-to guides on low-e storm window installation for the Building America Solution Center, and a video posted on YouTube. PNNL's efforts were reviewed by the Pacific Northwest Regional Technical Forum (RTF), which serves as the advisory board to the Pacific Northwest Electric Power Planning Council and Bonneville Power Administration. In late July 2015, the RTF approved the low-e storm window measure’s savings and specifications, a critical step in integrating low-e storm windows into energy-efficiency planning and utility weatherization and incentive programs. PNNL estimates that more than 90 million homes in the United States with single-pane or low-performing double-pane windows would benefit from the technology. Low-e storm windows are suitable not only for private residences but also for small commercial buildings, historic properties, and facilities that house residents, such as nursing homes, dormitories, and in-patient facilities. To further assist in the market transformation of low-e storm windows and other high-efficiency window attachments, DOE helped found the window Attachment Energy Rating Council (AERC) in 2015. AERC is an independent, public interest, non-profit organization whose mission is to rate, label, and certify the performance of window attachments.

Building Technologies Office↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration and Performance Monitoring of Foundation Heat Exchangers (FHX) in Ultra-High Energy Efficient Research Homes

The more widespread use of Ground Source Heat Pump (GSHP) systems has been hindered by their high first cost, which is mainly driven by the cost of the drilling and excavation for installation of ground heat exchangers (GHXs). A new foundation heat exchanger (FHX) technology was proposed to reduce first cost by placing the heat exchanger into the excavations made during the course of construction (e.g., the overcut for the basement and/or foundation and run-outs for water supply and the septic field). Since they reduce or eliminate the need for additional drilling or excavation, foundation heat exchangers have the potential to significantly reduce or eliminate the first cost premium associated with GSHPs. Since December 2009, this FHX technology has been demonstrated in two ultra-high energy efficient new research houses in the Tennessee Valley, and the performance data has been closely monitored as well. This paper introduces the FHX technology with the design, construction and demonstration of the FHX and presents performance monitoring results of the FHX after one year of monitoring. The performance monitoring includes hourly maximum and minimum entering water temperature (EWT) in the FHX compared with the typical design range, temperature difference (i.e., T) across the FHX, and hourly heat transfer rate to/from the surrounding soil.

15 GEOTHERMAL ENERGY↗

Mind the Gap: Summary of Window Residential Retrofit Solutions

Improving the insulation, solar heat gain, and infiltration characteristics of windows in a home has the potential to significantly improve the overall thermal performance by reducing heat transfer through the window and also by decreasing infiltration of outdoor air into the home. As approximately 43% of existing homes still have single-pane clear windows (~50 million houses) and millions of other homes have only double-pane clear windows (Cort 2013), improving window performance also presents a significant opportunity for energy savings in the residential sector. Today, various energy-saving window retrofit opportunities are available to homeowners, ranging from window coverings and storm panels to highly-insulating triple-pane R-5 window replacements. Many of these technologies have been evaluated in the field, in the “Lab Homes” at Pacific Northwest National Laboratory, and through modeling to prove their cost-effectiveness and performance in different climate regions. Recently, the Pacific Northwest’s Regional Technical Forum approved a utility measure for low- emissivity storm windows based on such data. This action represents a watershed moment for increasing the variety and prevalence of fenestration options in utility programs, especially for the low-income demographic. This paper will review various window retrofit options, the most recent field test and modeling data regarding their performance and cost-effectiveness, and discuss future rating efforts. This information is useful for utilities and energy-efficiency program managers to help effectively implement incentive measures for these technologies.

HVAC↗

Smart Homes and Buildings Research at the Energy Systems Integration Facility

Watch how NREL researchers are using the unique capabilities of the Energy Systems Integration Facility (ESIF) to develop technologies that will help the “smart” homes and buildings of the future perform efficiently and communicate effectively with the electricity grid while enhancing occupants' comfort and convenience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DOE Zero Energy Ready Home Case Study: Greenhill Contracting, Inc., Hickory Ridge

Greenhill Contracting built this 3,912-ft2 house in Gardiner, New York, to the high-performance criteria of the DOE Zero Energy Ready Home (ZERH) program. A highly efficient air-source heat pump heats and cools the home’s interior, while the roof-mounted photovoltaic system offsets electricity usage to cut energy bills to nearly zero. Many months the home owners see a credit on their utility bill.

2017 Housing Innovation Award↗

Comfort and HVAC Performance for a New Construction Occupied Test House in Roseville, California

K. Hovnanian® Homes constructed a 2,253-ft2 single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ductless Mini-Split Heat Pump Comfort Evaluation

Field tests were conducted in two homes in Austin, TX, to evaluate the comfort performance of ductless minisplit heat pumps (DMSHPs), measuring temperature and relative humidity measurements in four rooms in each home before and after retrofitting a central HVAC system with DMSHPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Performance of R-1234yf Heat Pump Water Heaters

Heat pump water heaters (HPWH) provide a resource for increasing water heating efficiency in U.S. residences. Electric HPWHs have traditionally utilized R-134a as the refrigerant in the vapor-compression cycle; however, this refrigerant is undesirable long-term due to its high global warming potential. For HPWHs, low global warming potential refrigerants such as R-1234yf may offer comparable performance, but the evaluation of these systems has been limited to laboratory settings. This study provides field evaluations of off-the-shelf HPWHs that had their factory R-134a refrigerant replaced with an optimized charge of R-1234yf. The field evaluation consisted of R-1234yf HPWHs at two occupied field sites and two unoccupied, simulated lab homes. At the two residential field sites with occupants, the R-1234yf HPWHs operated issue-free for the 18-month field trial, and the home occupants perceived no change in HPWH performance relative to their prior R-134a HPWHs. At the lab homes, under simulated hot water draws, the average daily operating efficiency of the R-1234yf HPWH was within 2% of the baseline R-134a HPWHs.

42 ENGINEERING↗

Testing of a Whole Home Energy Management System (Cooperative Research and Development Final Report)

NREL and B&B Technology Solutions Inc. will perform verification testing to demonstrate the effectiveness of our whole home energy management system. This energy management system will allow the electrification of various styles of homes reducing the emissions of CO2 by replacing existing fossil fuel-based home systems. CRADA benefit to DOE, Participant, and US Taxpayer: assists laboratory in achieving programmatic scope, and/or uses the laboratory's core competencies, and/or enhances U.S. competitiveness by utilizing DOE developed intellectual property and/or capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗