Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A High-Resolution Measurement of Ball IR Black Paint's Low-Temperature Emissivity

High-emissivity paints are commonly used on thermal control system components. The total hemispheric emissivity values of such paints are typically high (nearly 1) at temperatures above about 100 Kelvin, but they drop off steeply at lower temperatures. A precise knowledge of this temperature-dependence is critical to designing passively-cooled components with low operating temperatures. Notable examples are the coatings on thermal radiators used to cool space-flight instruments to temperatures below 40 Kelvin. Past measurements of low-temperature paint emissivity have been challenging, often requiring large thermal chambers and typically producing data with high uncertainties below about 100 Kelvin. We describe a relatively inexpensive method of performing high-resolution emissivity measurements in a small cryostat. We present the results of such a measurement on Ball InfraRed BlackTM(BIRBTM), a proprietary surface coating produced by Ball Aerospace and Technologies Corp (BATC), which is used in spaceflight applications. We also describe a thermal model used in the error analysis.

Tuttle, Jim↗

High resolution Cerenkov and range detectors for balloon-borne cosmic-ray experiment

A combination of an active Cerenkov detector and passive range detectors is proposed for the high resolution measurement of isotopic composition in the neighborhood of iron in the galactic cosmic rays. A large area (4,300 sq cm) Cerenkov counter and passive range detectors were tested. Tests with heavy ions (2.1 GeV/amu C-12, 289 MeV/amu Ar-40, and 594 MeV/amu Ne-20) revealed the spatial uniformity of response of the Cerenkov counter to be better than 1% peak-to-peak. Light collection efficiency is independent of projectile energy and incidence angle to within at least 0.5%. Passive Lexan track recorders to measure range in the presence of the nuclear interaction background which results from stopping particles through 0.9 interaction lengths of matter were also tested. It was found that nuclear interactions produce an effective range straggling distribution only approximately 75% wider than that expected from range straggling alone. The combination of these tested techniques makes possible high mass resolution in the neighborhood of iron.

Ahlen, S. P.↗

Revisiting the Effectiveness Of HCHO/NO2 Ratios for Inferring Ozone Sensitivity to Its Precursors Using High Resolution Airborne Remote Sensing Observations in A High Ozone Episode During the KORUS-AQ Campaign

The nonlinear chemical processes involved in ozone production (P(O3)) have necessitated using proxy indicators to convey information about the primary dependence of P(O3) on volatile organic compounds (VOCs) or nitrogen oxides (NOx). In particular, the ratio of remotely sensed columns of formaldehyde (HCHO) to nitrogen dioxide (NO2) has been widely used for studying O3 sensitivity. Previous studies found that the errors in retrievals and the incoherent relationship between the column and the near-surface concentrations are a barrier in applying the ratio in a robust way. In addition to these obstacles, we provide calculational-observational evidence, using an ensemble of 0-D photochemical box models constrained by DC-8 aircraft measurements on an ozone event during the Korea-United States Air Quality (KORUS-AQ) campaign over Seoul, to demonstrate the chemical feedback of NO2 on the formation of HCHO is a controlling factor for the transition line between NOx-sensitive and NOx-saturated regimes. A fixed value (~2.7) of the ratio of the chemical loss of NOx (LNOx) to the chemical loss of HO2+RO2 (LROx) perceptibly differentiates the regimes. Following this value, data points with a ratio of HCHO/NO2 less than 1 can be safely classified as NOx-saturated regime, whereas points with ratios between 1 and 4 fall into one or the other regime. We attribute this mainly to the HCHO-NO2 chemical relationship causing the transition line to occur at larger (smaller) HCHO/NO2 ratios in VOC-rich (VOC-poor) environments. We then redefine the transition line to LNOx/LROx~2.7 that accounts for the HCHO-NO2 chemical relationship leading to HCHO = 3.7 × (NO2 – 1.14 × 1016 molec.cm-2). Although the revised formula is locally calibrated (i.e., requires for readjustment for other regions), its mathematical format removes the need for having a wide range of thresholds used in HCHO/NO2 ratios that is a result of the chemical feedback. Therefore, to be able to properly take the chemical feedback into consideration, the use of HCHO = a × (NO2 – b) formula should be preferred to the ratio in future works. We then use the Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) airborne instrument to study O3 sensitivity in Seoul. The unprecedented spatial (250 × 250 m2) and temporal (~every 2 h) resolutions of HCHO and NO2 observations form the sensor enhance our understanding of P(O3) in Seoul; rather than providing a crude label for the entire city, more in-depth variabilities in chemical regimes are observed that should be able to inform mitigation strategies correspondingly.

KORUS-AQ; formaldehyde; NOx; VOC; OMI; GeoTASO; oz↗

The AXAF high resolution camera (HRC) and its use for observations of distant clusters of galaxies

The High Resolution Camera being developed for AXAF is briefly described, comparing it with its predecessor, the Einstein HRI, and providing preliminary performance data. The HRC is a 10 cm x 10 cm detector with CsI coated microchannel plates providing a large field of view device with high X-ray quantum efficiency. The overall sensitivity of the HRC on AXAF is about 50 times that of the Einstein HRI. An example of the power of this instrument is discussed in the context of studies of distant clusters of galaxies. The HRC can detect individual galaxies in a cluster of redshift 1, if they are similar to the early-type galaxies in nearby clusters that have been observed by the Einstein instruments. The HRC will be used to measure the luminosity function for clusters of galaxies as a function of their distance up to a redshift of 1. This will allow observation of evolutionary effects in clusters as a whole, while the detection of individual galaxies will permit studies of galaxy evolution in a cluster environment.

Murray, S. S.↗

High-resolution submillimeter-wave radiometry of supersonic flow

The recent development of a high-resolution submillimeter-wave heterodyne radiometer has made possible the first measurements of H2O molecule rotational line excitation temperatures and detailed profiles in supersonic flow. Absorption signals were measured across the flow for the 2/11/ from 2//02/ (752 GHz) para-H2O rotational transition against a hot background. These signals decrease downstream owing to the volume expansion of the gas away from the sonic nozle exit in the high-vacuum chamber. Radiative transfer calculations based on the large-velocity-gradient approximation and multilevel statistical equilibrium agree with these results and with the measured spectral line shapes. The data reveal nearly isentropic gas expansion and cooling. These studies have shown that submillimeter-wave heterodyne radiometry can be useful for remote sensing of supersonic flow with low mass flux, provided the signal transmission is through a dry or thin atmosphere.

Dionne, G. F.↗

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors↗

Quantification of several atmospheric gases from high resolution infrared solar spectra obtained at the South Pole in 1980 and 1986

High-resolution solar absorption spectra recorded at the Amundsen-Scott South Pole Station were analyzed to obtain total column amounts of O3, N2O, HNO3, CO2, CH4, and CF2Cl2, and to investigate the differences in the values obtained in December 1980 with those obtained in December 1986. In addition, vertical column amounts for HCl, NO, NO2, and C2H6 were derived for December 1986. One interesting feature of these results is that the total column amounts of HCl measured for several days at the South Pole (/6.4 + or - 0.8/ x 10 to the 15th molecules/sq cm) were high compared with the HCl column amounts reported for lower latitudes.

Goldman, Aaron↗

High Resolution VLBA Observations of NGC 4261

The VLBA's high angular resolution at 22 and 43 GHz allows the nuclei of nearby radio galaxies to be imaged with very high linear resolution (a few hundred Schwarzschild radii or less for central black hole masses of about 10(exp 8) - 10(exp 9) solar mass). This is the scale on which absorption by the dense ionized inner regions of nuclear accretion disk should be detected. We present 8, 22, and 43 GHz VLBA images of the two-sided radio jets in NGC 4261 (2C370) with sub-parsec resolution, and derive constraints on the physical properties of the inner accretion disk. In addition, preliminary results from multi-epoch VLBA observations to detect proper motions in the jet and counterjet, and thus determine the orientation of the radio axis to our line of sight, may be available. Our multi-frequency images show apparent absorption by a nearly edge-on disk at 8 GHz, but not evidence for absorption at 22 or 43 GHz. Assuming that this is due to a lower optical depth for free-free absorption at 22 and 43 GHz, we find an upper limit for the electron density of approximately 10(exp 8)* Square root of(0.1/L)/cubic cm, where L is the path length through the disk in pc. The disk inclination, and therefore the likely path length, will be better determined by the ongoing VLBA proper motions measurements. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with the National Aeronautics and Space Administration.

Jones, D. L.↗

High Resolution VLBA Observations of NGC 4261

The VLBA's high angular resolution at 22 and 43 GHz allows the nuclei of nearby radio galaxies to be imaged with very high linear resolution. This is the scale on which absorption by the dense ionized inner regions of nuclear accretion disk should be detected.

Interferometry↗

Three-Dimensional Imaging and Numerical Reconstruction of Graphite/Epoxy Composite Microstructure Based on Ultra-High Resolution X-Ray Computed Tomography

A combined experimental and computational study aimed at high-resolution 3D imaging, visualization, and numerical reconstruction of fiber-reinforced polymer microstructures at the fiber length scale is presented. To this end, a sample of graphite/epoxy composite was imaged at sub-micron resolution using a 3D X-ray computed tomography microscope. Next, a novel segmentation algorithm was developed, based on concepts adopted from computer vision and multi-target tracking, to detect and estimate, with high accuracy, the position of individual fibers in a volume of the imaged composite. In the current implementation, the segmentation algorithm was based on Global Nearest Neighbor data-association architecture, a Kalman filter estimator, and several novel algorithms for virtualfiber stitching, smoothing, and overlap removal. The segmentation algorithm was used on a sub-volume of the imaged composite, detecting 508 individual fibers. The segmentation data were qualitatively compared to the tomographic data, demonstrating high accuracy of the numerical reconstruction. Moreover, the data were used to quantify a) the relative distribution of individual-fiber cross sections within the imaged sub-volume, and b) the local fiber misorientation relative to the global fiber axis. Finally, the segmentation data were converted using commercially available finite element (FE) software to generate a detailed FE mesh of the composite volume. The methodology described herein demonstrates the feasibility of realizing an FE-based, virtual-testing framework for graphite/fiber composites at the constituent level.

Czabaj, M. W.↗

High-resolution spectral measurement of the HNO3 5.9-micron band using a tunable diode laser

High resolution spectra in the region of the v(2) band of nitric acid have been obtained for selected portions of the HNO3 spectrum using tunable diode laser techniques. Continuous spectra are presented from 1718.97/cm to 1729.57/cm, with a spectral resolution not greater than 0.001/cm (30 MHz). Absolute line intensities and line positions are presented. Self- and foreign-gas (N2) broadening coefficients were iteratively calculated from the experimental data and were determined to be alpha(a) = 0.74/cm atm and alpha (f) = 0.13/cm atm, respectively.

Bair, C. H.↗

High-Resolution Subsurface-Interface Radar

Homomorphic deconvolution signal processing enhances information obtained in high-resolution soil-depth measurements by radar. Proposed technique is expected to increase accuracy with which soil-layer depths are gaged. Intended use with subsurface-interface radar sounding, in which subsurface features of soils are mapped.

Steinway, W. J.↗

High-resolution dayglow O I /1304 A/ and O I /989 A/ rocket observations

High-resolution (about 1 A) dayglow observations of the O I(1304) A) and O I(989 A) multiplets were made from an Astrobee-F rocket payload (25.046 CE) launched from White Sands, New Mexico at local noon on June 27, 1980 to an apogee of 260 km. Three components of the O I(1304 A) multiplet were measured at zenith angles of approximately 50 and 140 deg at 1.1 A resolution. Over the entire altitude range of observation, i.e., 100-260 km, the three components were found to be equal to within + or - 15%. The shape of the O I(989 A) multiplet distribution observed on the flight at 1.3 A resolution was indistinguishable from an optically thin source with the energy levels of the excited state populated according to their statistical weights in spite of the large optical depths of the O I(989 A) multiplet at rocket altitudes.

Christensen, A. B.↗

High Resolution Imager (HRI) for the Roentgen Satellite (ROSAT) definition study

The design of the high resolution imager (HRI) on HEAO 2 was modified for use in the instrument complement of the Roentgen Satellite (ROSAT). Mechanical models of the front end assembly, central electronics assembly, and detector assembly were used to accurately represent the HRI envelope for both fit checks and focal plane configuration studies. The mechanical and electrical interfaces were defined and the requirements for electrical ground support equipment were established. A summary description of the ROSAT telescope and mission is included.

Source record↗

High resolution X- and gamma-ray spectroscopy of cosmic X-ray sources

A high resolution X-ray spectrometer and large area phoswich detector were designed and co-aligned in a common elevation mounting in order to measure solar and cosmic X-ray and gamma ray emission in the 13 to 600 KeV energy range from a balloon. The instrument is described and results obtained for the Crab Nebula, the supernova remnant Cas A, and the Sun are discussed and analyzed.

Lin, R. P.↗