Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “harmonic oscillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Fluctuation–dissipation relation for a quantum Brownian oscillator in a parametrically squeezed thermal field

In this paper we study the nonequilibrium evolution of a quantum Brownian oscillator, modeling the internal degree of freedom of a harmonic atom or an Unruh–DeWitt detector, coupled to a nonequilibrium and nonstationary quantum field bath and inquire whether a fluctuation–dissipation relation (FDR) can exist after/if it approaches equilibration. This is a nontrivial issue because a squeezed field bath cannot reach equilibration and yet, as this work shows, the system oscillator indeed can, which is a necessary condition for FDRs. We discuss three different settings: (A) The bath field essentially remains in a squeezed thermal state throughout, whose squeeze parameter is a mode- and time-independent constant. This situation is often encountered in quantum optics and quantum thermodynamics. (B) The bath field is initially in a thermal state, but is subjected to a parametric process leading to mode- and time-dependent squeezing. This scenario is encountered in cosmology and dynamical Casimir effects. The squeezing in the bath in both types of processes will affect the oscillator’s nonequilibrium evolution. We show that at late times it approaches equilibration and this stationarity condition warrants the existence of a FDR. The trait of squeezing is marked by the oscillator’s effective equilibrium temperature, and the proportionality factor in the FDR is only related to the stationary component of the noise kernel of the bath field. Setting (C) is more subtle: A finite system–bath coupling strength can set the oscillator in a squeezed state even though the bath field is stationary and does not engage in any parametric process. The squeezing of the system in this case is in general time-dependent but becomes constant when the internal dynamics is fully relaxed. We begin with comments on the broad range of physical processes involving squeezed thermal baths and end with some remarks on the significance of FDRs in capturing the essence of quantum backreaction in nonequilibrium and stochastic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stabilization of electron streams in type 3 solar radio bursts

It is shown that the electron streams that give rise to Type 3 solar radio bursts are stable and will not be decelerated while propagating out of the solar corona. The stabilization mechanism depends on the parametric oscillating two stream instability. Radiation is produced near the fundamental and second harmonic of the local electron plasma frequency. Estimates of the emission at the second harmonic indicate that the wave spectra created by the oscillating two stream instability can account for the observed intensities of Type 3 bursts.

Papadopoulos, K.↗

Modified Virtual Oscillator-Based Operation of Grid-Forming Converters with Single Voltage Sensor: Preprint

This paper proposes a virtual oscillator-based control architecture for a grid-forming converter with an inner current control loop. In general, the virtual oscillator is based on a Lienard type of oscillator equation with a cubic nonlinearity. A virtual oscillator alone cannot accommodate unbalanced or harmonic mitigation while operating converters in grid-forming mode. Therefore, to accomplish better tracking performance, incorporating the provision for nonlinear and/or unbalanced loads, an inner current control loop is utilized that is based on the Lyapunov energy function type control architecture. To reduce the overall cost of implementation and ensure proper phase difference in the generated voltages, the implemented virtual oscillator operates with only one voltage feedback from the point of common coupling. To verify the effectiveness of the proposed approach, the overall system has been modeled in MATTLAB/Simulink and PLECS domain. This paper also presents case studies showing the successful production of low harmonic load voltages under nonideal loading conditions, along with other important results.

dual second order generalized integrator↗

Stabilization of electron streams in type III solar radio bursts

We show that the electron streams that give rise to type III solar radio bursts are stable and will not be decelerated while propagating out of the solar corona. The stabilization mechanism depends on the parametric oscillating two-stream instability. Radiation is produced near the fundamental and second harmonic of the local electron plasma frequency. Estimates of the emission at the second harmonic indicate that the wave spectra created by the oscillating two-stream instability can account for the observed intensities of type III bursts.

Papadopoulos, K.↗

Modified Virtual Oscillator Based Operation of Grid Forming Converters with Single Voltage Sensor

Virtual oscillator based control architecture for grid forming converter with inner current control loop for additional objective accomplishments is proposed in this paper. In general, virtual oscillator is based on Lienard type of oscillator equation with a cubic nonlinearity. Virtual oscillator alone cannot accommodate unbalanced or harmonic mitigation while operating converters in grid forming mode. Therefore, to accomplish better tracking performance, incorporating the provision for nonlinear and/or unbalanced loads, an inner current control loop is utilized which is based upon Lyapunov energy function type control architecture due to its advantages. To reduce the overall cost of implementation and ensure proper phase difference in the generated voltages, the implemented virtual oscillator operates with only one voltage feedback from the point of common coupling as presented in this paper. To verify the effectiveness of the proposed approach, the overall system has been modeled in MATTLAB/Simulink and PLECS domain and case studies showing the successful production of low harmonic load voltages under nonideal loading condition along with other important results are presented in this paper.

dual second order generalized integrator↗

Periodic variations in stratospheric-mesospheric temperature from 20-65 km at 80 N to 30 S

Results on large-scale periodic variations of the stratospheric-mesospheric temperature field based on Meteorological Rocket Network (MRN) measurements are reported for a long-term (12-year) mean, the quasi-biennial oscillation (QBO), and the first three harmonics of the annual wave (annual wave, semi-annual wave, and terannual wave or 4-month variation). Station-to-station comparisons are tabulated and charted for amplitude and phase of periodic variations in the temperature field. Masking and biasing factors, such as diurnal tides, solar radiation variations, mean monthly variations, instrument lag, aerodynamic heating, are singled out for attention. Models of the stratosphere will have to account for these oscillations of different periods in the thermal field and related properties of the wind fields, with multilayered horizontal stratification with height taken into account.-

Nastrom, G. D.↗

Eddy Current Shielding of the Magnetic Field Ripple in the EIC Electron Storage Ring Vacuum Chambers

The EIC electron storage ring (ESR) has very tight tolerances for the beam position and size stability at the interaction point. The oscillations at the proton betatron frequency and its harmonics are the most dangerous because, for instance, they could lead to unacceptable proton emittance growth from the oscillating beam-beam kick from the electrons at the amplitude of the positional oscillations as low as 10 -4 of the beam size. Even at much lower frequencies, down to the single Hz range, the position oscillations at a few percent level of the nominal beam size were found to be dangerous. These oscillations could have different causes including magnet power supply ripple, mag net vibration, noise in the main and crab RF systems, and some collective instabilities. To specify the acceptable level of the current ripple and noise of the magnet power supplies we need to accurately account for the eddy current shielding by the vacuum chamber, as well as, potentially, by the laminated magnet yokes (considered elsewhere). With some ap proximations, the chamber shielding can be described analytically. The main objective of this note is to derive these analytical expressions and to document the resulting shielding performance of the ESR chamber.

43 PARTICLE ACCELERATORS↗

Reducing distortion in an fm modulator.

Free-running oscillator incorporating correction circuit to improve linearity of voltage-variable capacitor for reducing second harmonic and intermodulation distortion

FREQUENCY MODULATION↗

A dual-frequency 183/380 GHz receiver for airborne applications

A complete dual-frequency cryogenic heterodyne receiver operating at 183 and 380 GHz is described. The cooled mixers are whisker-contacted GaAs Schottky diodes mounted in reduced-height fundamental-mode waveguide. The local oscillators are Gunn-oscillator-driven multipliers using GaAs varactor diodes as the harmonic generators. Quasi-optical techniques are used extensively for coupling the remote and local oscillator signals into the mixers. The overall system double side-band (DSB) noise temperature is 320 K for the 183-GHz receiver and 650 K for the 380 GHz receiver.

Batelaan, Paul D.↗

Single-mode squeezed-light generation and tomography with an integrated optical parametric oscillator

Quantum optical technologies promise advances in sensing, computing, and communication. A key resource is squeezed light, where quantum noise is redistributed between optical quadratures. We introduce a monolithic, chip-scale platform that exploits the χ (2) nonlinearity of a thin-film lithium niobate (TFLN) resonator device to efficiently generate squeezed states of light. Our system integrates all essential components—except for the laser and two detectors—on a single chip with an area of one square centimeter, reducing the size, operational complexity, and power consumption associated with conventional setups. Using the balanced homodyne measurement subsystem that we implemented on the same chip, we measure a squeezing of 0.55 decibels and an anti-squeezing of 1.55 decibels. We use 20 milliwatts of input power to generate the parametric oscillator pump field by using second harmonic generation on the same chip. Our work represents a step toward compact and efficient quantum optical systems posed to leverage the rapid advances in integrated nonlinear and quantum photonics.

97 MATHEMATICS AND COMPUTING↗

An eastward propagating compressional Pc 5 wave observed by AMPTE/CCE in the postmidnight sector

This paper presents a detailed analysis of a compressional Pc 5 wave observed in the postmidnight sector on July 21, 1986, using data from the magnetometer, the charge-energy-mass spectrometer, and the medium-energy particle analyzer aboard the AMPTE/Charge Composition Explorer (CCE) spacecraft. The Pc 5 wave exhibited harmonically related transverse and compressional magnetic oscillations, modulation of the flux of medium energy protons, and a large azimuthal wave number, i.e., properties that are similar to those of compressional Pc5 waves observed previously at geostationary orbit. The unique observations recorded by the AMPTE/CCE included the occurrence of the wave in the postmidnight sector, its sunward propagation with respect to the spacecraft, and the left-handed polarization of the perturbed magnetic field. In spite of the morphological uniqueness observed, the excitation of the July 21 event is considered to be due to the same type of instability as operates at geostationary orbit.

Takahashi, K.↗

Coherence properties of a doubly resonant monolithic optical parametric oscillator

A doubly resonant optical parametric oscillator (DRO) pumped with the second harmonic of a narrow-linewidth Nd:YAG laser is described. The linewidth of the DRO signal was less than 13 kHz, the DRO was shown to generate a phase-locked subharmonic of the pump at degeneracy, and the signal and the idler were shown to be mutually coherent with the pump and to be phase-anticorrelated with each other away from degeneracy. The signal-idler heterodyne linewidth was 500 Hz, and pump phase modulation was shown to transfer to the DRO phase at degeneracy.

Nabors, C. D.↗

Solid-state lasers for coherent communication and remote sensing

Work in the stabilization of monolithic Nd:YAG lasers and the application of these lasers to nonlinear optical frequency conversion is discussed. The intrinsic stability of semiconductor diode laser pumped solid state lasers has facilitated a number of demonstration in external resonant cavity harmonic generation and stable optical parametric oscillation. Relative laser frequency stabilization of 0.3 Hz was achieved, and absolute stability of a few hundred hertz is anticipated. The challenge is now to reproduce this frequency stability in the output of tunable nonlinear optical devices. Theoretical and experimental work toward this goal are continuing.

Byer, Robert L.↗

The Third International Symposium on Space Terahertz Technology: Symposium proceedings

Papers from the symposium are presented that are relevant to the generation, detection, and use of the terahertz spectral region for space astronomy and remote sensing of the Earth's upper atmosphere. The program included thirteen sessions covering a wide variety of topics including solid-state oscillators, power-combining techniques, mixers, harmonic multipliers, antennas and antenna arrays, submillimeter receivers, and measurement techniques.

Source record↗

The time-delay spectrum of GX 5-1 in its horizontal branch

Using a cross-spectral technique we investigate time delays between intensity variations of GX 5-1 in 10 X-ray spectral channels. The data were taken during a 1989 Ginga observation during which the source was in its horizontal-branch spectral state. We develope a new method to measure 'time-delay spectra' in fixed Fourier frequency ranges and use it to determine the energy and intensity dependence of time delays in the low-frequency noise (nu less than 2 Hz), the horizontal branch quasi-periodic oscillations (QPO), and the QPO second harmonic. These are the first time-delay spectra of a Z-source in its horizontal branch, and the first detection of time delays in the second harmonic. We consider two mechanisms for the production of the time lags: Comptonization and evolving shots. We perform Monte Carlo simulations of Compton scattering in a homogeneous, isotropic, central corona and show that it qualitatively explain the observed energy and time-delay spectra, but that it cannot explain the differences in the QPO first and second harmomnic time-delay spectra, nor the observed dependence of the QPO fractional rms variability upon energy. We consider implications of our results for millisecond pulsar searches in low-mass X-ray binaries.

Vaughan, B.↗