Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

N/P GaAs concentrator solar cells with an improved grid and bushbar contact design

The major requirements for a solar cell used in space applications are high efficiency at AMO irradiance and resistance to high energy radiation. Gallium arsenide, with a band gap of 1.43 eV, is one of the most efficient sunlight to electricity converters (25%) when the the simple diode model is used to calculate efficiencies at AMO irradiance, GaAs solar cells are more radiation resistant than silicon solar cells and the N/P GaAs device has been reported to be more radiation resistant than similar P/N solar cells. This higher resistance is probably due to the fact that only 37% of the current is generated in the top N layer of the N/P cell compared to 69% in the top layer of a P/N solar cell. This top layer of the cell is most affected by radiation. It has also been theoretically calculated that the optimized N/P device will prove to have a higher efficiency than a similar P/N device. The use of a GaP window layer on a GaAs solar cell will avoid many of the inherent problems normally associated with a GaAlAs window while still proving good passivation of the GaAs surface. An optimized circular grid design for solar cell concentrators has been shown which incorporates a multi-layer metallization scheme. This multi-layer design allows for a greater current carrying capacity for a unit area of shading, which results in a better output efficiency.

Desalvo, G. C.↗

Analysis of Actual Operating Conditions of an Off-grid Solid Oxide Fuel Cell

Fuel cells have been proposed as ideal replacements for other technologies in remote locations such as Rural Alaska. A number of suppliers have developed systems that might be applicable in these locations, but there are several requirements that must be met before they can be deployed: they must be able to operate on portable fuels, and be able to operate with little operator assistance for long periods of time. This project was intended to demonstrate the operation of a 5 kW fuel cell on propane at a remote site (defined as one without access to grid power, internet, or cell phone, but on the road system). A fuel cell was purchased by the National Park Service for installation in their newly constructed visitor center at Exit Glacier in the Kenai Fjords National Park. The DOE participation in this project as initially scoped was for independent verification of the operation of this demonstration. This project met with mixed success. The fuel cell has operated over 6 seasons at the facility with varying degrees of success, with one very good run of about 1049 hours late in the summer of 2006, but in general the operation has been below expectations. There have been numerous stack failures, the efficiency of electrical generation has been lower than expected, and the field support effort required has been far higher than expected. Based on the results to date, it appears that this technology has not developed to the point where demonstrations in off road sites are justified.

30 DIRECT ENERGY CONVERSION↗

Grid-Optimization Program for Photovoltaic Cells

CELLOPT program developed to assist in designing grid pattern of current-conducting material on photovoltaic cell. Analyzes parasitic resistance losses and shadow loss associated with metallized grid pattern on both round and rectangular solar cells. Though performs sensitivity studies, used primarily to optimize grid design in terms of bus bar and grid lines by minimizing power loss. CELLOPT written in APL.

Daniel, R. E.↗

Fuel Cell Backup Power System for Grid Service and Microgrid in Telecommunication Applications

This paper presents the feasibility and economics of using fuel cell backup power systems in telecommunication cell towers to provide grid services (e.g., ancillary services, demand response (DR)) as well as power for cell towers during emergency conditions. This study evaluates the strategic integration of clean, efficient, and reliable fuel cell systems with the grid for improved economic benefits. The backup systems can potentially enhance capabilities through information exchange with the power grid, which adds value for grid services that depend on location and time. The economic analysis focused on the potential revenue for distributed telecommunications fuel cell backup units to provide value-added power supply. This paper includes case studies on current fuel cell backup power locations and regional grid service programs. The grid service benefits and system configurations for different operation modes provide opportunities for expanding backup fuel cell applications responsive to grid needs. The objective of this work is primarily on how fuel cells can become a significant part of the telecom backup power fleet to reduce system costs, environmental impact, and dependence on fossil fuels, while ensuring continuity of indispensable service for mobile users. The study identifies different fuel cell applications and nano/microgrid approaches for an extensive network of fuel cells as distributed energy resources. The possibilities of various application scenarios extend to fuel cell technologies and microgrids for reliable power supply.

30 DIRECT ENERGY CONVERSION↗

Metal nano-grids for transparent conduction in solar cells

A general procedure for predicting metal grid performance in solar cells was developed. Unlike transparent conducting oxides (TCOs) or other homogeneous films, metal grids induce more resistance in the neighbor layer. The resulting balance of transmittance, neighbor and grid resistance was explored in light of cheap lithography advances that have enabled metal nano-grid (MNG) fabrication. The patterned MNGs have junction resistances and degradation rates that are more favorable than solution-synthesized metal nanowires. Neighbor series resistance was simulated by the finite element method, although a simpler analytical model was sufficient in most cases. Finite-difference frequency-domain transmittance simulations were performed for MNGs with minimum wire width (w) of 50 nm, but deviations from aperture transmittance were small in magnitude. Depending on the process, MNGs can exhibit increased series resistance as w is decreased. However, numerous experimental reports have already achieved transmittance-MNG sheet resistance trade-offs comparable to TCOs. The transmittance, neighbor and MNG series resistances were used to parameterize a grid fill factor for a solar cell. In conclusion, this new figure of merit was used to demonstrate that although MNGs have only been employed in low efficiency solar cells, substantial gains in performance are predicted for decreased w in all high efficiency absorber technologies.

14 SOLAR ENERGY↗

Solar house system interfaced with the power utility grid

Photovoltaic cells may be used to convert sunlight directly into electrical energy and into low-grade heat to be used for large scale terrestrial solar energy conversion. Both forms of energy can be utilized if such cells are deployed in close proximity to the consumer (rooftop). CdS/Cu2S solar cells are an example of cells which may be produced inexpensively enough to become economically attractive. Cell parameters relevant for combined solar conversion are presented. Critical issues, such as production yield, life expectancy, stability of performance, are discussed. Systems design parameters related to operating temperatures are analyzed. First results obtained on Solar One, the experimental solar house of the University of Delaware, are given. Economic aspects are discussed.

Boeer, K. W.↗

Getting the current out

Progress of a photovoltaic (PV) device from a research concept to a competitive power-generation source requires an increasing concern with current collection. The initial metallization focus is usually on contact resistance, since a good ohmic contact is desirable for accurate device characterization measurements. As the device grows in size, sheet resistance losses become important and a metal grid is usually added to reduce the effective sheet resistance. Later, as size and conversion efficiency continue to increase, grid-line resistance and cell shadowing must be considered simultaneously, because grid-line resistance is inversely related to total grid-line area and cell shadowing is directly related. A PV cell grid design must consider the five power-loss phenomena mentioned above: sheet resistance, contact resistance, grid resistance, bus-bar resistance and cell shadowing. Although cost, reliability and usage are important factors in deciding upon the best metallization system, this paper will focus only upon grid-line design and substrate material problems for flat-plate solar arrays.

Burger, D. R.↗

Finite spatial-grid effects in energy-conserving particle-in-cell algorithms

Finite-grid (or aliasing) instabilities are pervasive in particle-in-cell (PIC) plasma simulation algorithms, and force the modeler to resolve the smallest (Debye) length scale in the problem regardless of dynamical relevance. These instabilities originate in the aliasing of interpolation errors between mesh quantities and particles (which live in the space–time continuum). Recently, strictly energy-conserving PIC (EC-PIC) algorithms have been developed that promise enhanced robustness against aliasing instabilities. In this study, we confirm by analysis that EC-PIC is stable against aliasing instabilities for stationary plasmas. For drifting plasmas, we demonstrate by analysis and numerical experiments that, while EC-PIC algorithms are not free from these instabilities in principle, they feature a benign stability threshold for finite-temperature plasmas that make them usable in practice for a large class of problems (featuring ambipolarity and realistic ion-electron mass ratios) without the need to consider the size of the Debye length. We also demonstrate that this threshold is absent for the popular momentum-conserving PIC algorithms, which are therefore unstable for both drifting and stationary plasmas beyond a threshold in cell size compared to Debye length. Finite-grid (or aliasing) instabilities are pervasive in particle-in-cell (PIC) plasma simulation algorithms, and force the modeler to resolve the smallest (Debye) length scale in the problem regardless of dynamical relevance. These instabilities originate in the aliasing of interpolation errors between mesh quantities and particles (which live in the space–time continuum). Recently, strictly energy-conserving PIC (EC-PIC) algorithms have been developed that promise enhanced robustness against aliasing instabilities. In this study, we confirm by analysis that EC-PIC is stable against aliasing instabilities for stationary plasmas. For drifting plasmas, we demonstrate by analysis and numerical experiments that, while EC-PIC algorithms are not free from these instabilities in principle, they feature a benign stability threshold for finite-temperature plasmas that make them usable in practice for a large class of problems (featuring ambipolarity and realistic ion-electron mass ratios) without the need to consider the size of the Debye length. Finally, we also demonstrate that this threshold is absent for the popular momentum-conserving PIC algorithms, which are therefore unstable for both drifting and stationary plasmas beyond a threshold in cell size compared to Debye length.

97 MATHEMATICS AND COMPUTING↗

Three-Dimensional Deformable Grid Electromagnetic Particle-in-cell for Parallel Computers

We describe a new parallel, non-orthogonal grid, three-dimensional electromagnetic particle-in-cell (EMPIC) code based on a finite-volume formulation. This code uses a logically Cartesian grid of deformable hexahedral cells, a discrete surface integral (DSI) algorithm to calculate the electromagnetic field, and a hybrid logical-physical space algorithm to push particles.

Cartesian grid Grid Electromagnetic electromagneti↗

Fuel Cell Stack Model for Real-Time Simulation of Grid-Connected Applications

Fuel cell stacks coupled with electrolyzers and hydrogen storage sites can be a promising category of distributed energy resources for both grid-connected and stand-alone power systems. However, because of high costs, at-scale hardware testing of fuel cell stacks for grid-connected applications is not economically viable at present. A model-based system that can accurately captures the steady-state and dynamic response of fuel cell stacks over long time periods (hours), is needed. This paper demonstrate a real-time electromagnetic transient model of a megawatt-scale, grid-connected proton exchange membrane fuel cell stack, coupled with a mass-based hydrogen storage system. This model can emulate the electrical steady-state and dynamic response of grid-connected fuel cell stacks. We validate the model using the response of commercial hardware fuel cell stacks and analytical models in the literature - using a digital real-time simulator (RSCAD). The proposed real-time model is then used to simulate cases spanning different time horizons and to design controller-hardware-in-the-loop experiments to evaluate controllers for hydrogen stations.

activation potential↗

Velocity field calculation for non-orthogonal numerical grids

Computational grids containing cell faces that do not align with an orthogonal (e.g. Cartesian, cylindrical) coordinate system are routinely encountered in porous-medium numerical simulations. Such grids are referred to in this study as non-orthogonal grids because some cell faces are not orthogonal to a coordinate system plane (e.g. xy, yz or xz plane in Cartesian coordinates). Non-orthogonal grids are routinely encountered at the Savannah River Site in porous-medium flow simulations for Performance Assessments and groundwater flow modeling. Examples include grid lines that conform to the sloping roof of a waste tank or disposal unit in a 2D Performance Assessment simulation, and grid surfaces that conform to undulating stratigraphic surfaces in a 3D groundwater flow model. Particle tracking is routinely performed after a porous-medium numerical flow simulation to better understand the dynamics of the flow field and/or as an approximate indication of the trajectory and timing of advective solute transport. Particle tracks are computed by integrating the velocity field from cell to cell starting from designated seed (starting) positions. An accurate velocity field is required to attain accurate particle tracks. However, many numerical simulation codes report only the volumetric flowrate (e.g. PORFLOW) and/or flux (flowrate divided by area) crossing cell faces. For an orthogonal grid, the normal flux at a cell face is a component of the Darcy velocity vector in the coordinate system, and the pore velocity for particle tracking is attained by dividing by water content. For a non-orthogonal grid, the flux normal to a cell face that lies outside a coordinate plane is not a true component of velocity with respect to the coordinate system. Nonetheless, normal fluxes are often taken as Darcy velocity components, either naively or with accepted approximation. To enable accurate particle tracking or otherwise present an accurate depiction of the velocity field for a non-orthogonal grid, Darcy velocity components are rigorously derived in this study from normal fluxes to cell faces, which are assumed to be provided by or readily computed from porous-medium simulation code output. The normal fluxes are presumed to satisfy mass balances for every computational cell, and if so, the derived velocity fields are consistent with these mass balances. Derivations are provided for general two-dimensional quadrilateral and three-dimensional hexagonal systems, and for the commonly encountered special cases of perfectly vertical side faces in 2D and 3D and a rectangular footprint in 3D.

97 MATHEMATICS AND COMPUTING↗

Lead-acid battery

A light weight lead-acid battery (30) having a positive terminal (36) and a negative terminal (34) and including one or more cells or grid stacks having a plurality of vertically stacked conductive monoplates (10, 20) with positive active material and negative active material deposited on alternating plates in the cell or grid stack. Electrolyte layers (26, 28) positioned between each monoplate are included to provide a battery cell having four sides which is capable of being electrically charged and discharged. Two vertical positive bus bars (42, 43) are provided on opposite sides of the battery cell for connecting the monoplates (10) with positive active material together in parallel current conducting relation. In addition, two negative bus bars (38, 39) on opposite sides of the battery cell each being adjacent the positive bus bars are provided for connecting the monoplates (20) with negative active material together in parallel current conducting relation. The positive (42, 43) and negative (38, 39) bus bars not only provide a low resistance method for connecting the plurality of conductive monoplates of their respective battery terminals (36, 34) but also provides support and structural strength to the battery cell structure. In addition, horizontal orientation of monoplates (10, 20) is provided in a vertical stacking arrangement to reduce electrolyte stratification and short circuiting due to flaking of positive and negative active materials from the monoplates.

Rowlette, John J.↗

PathTrace and MPVEASI: A Path Analysis Comparative Validation Study

Developed in 2018, PathTrace is a software package built with the intention of making path analysis simple and intuitive. PathTrace is a top-down pathway analysis software where a user is able to explore vulnerable pathways into a facility. The intention of utilizing a software tool like PathTrace is to characterize an existing physical protection system (PPS) and to upgrade the system to achieve a high level of response interruption, or probability of interruption (P I ) of the adversary. There are four steps for conducting path analysis using PathTrace. The first step is to identify an image to use to build the model and scale the model within PathTrace using a section of known distance (wall or fence perimeter, for example). The scaling process will produce a grid of cells through which the user is able to build a model. The second step is to fill out the grid of cells with four categories of materials: Barriers, Detection Areas, Jumps, and Targets. These materials apply associated delay and detection values to the cells in which they are applied. The third step is to represent the adversary and response forces. The adversaries are represented by their capabilities in interacting with the materials identified in step two, and the response is represented by how quickly they will be able to respond to an adversary attack. Finally, the user is able to take all of the information from the previous three steps and perform a Most Vulnerable Path (MVP) analysis. In this stage, the user is able to visualize vulnerable adversary pathways and reason about how to upgrade these pathways to provide a high level of P I .

97 MATHEMATICS AND COMPUTING↗

Top-grid monolayer graphene/Si Schottkey solar cell

Monolayer graphene/Si Schottkey solar cell was fabricated using a top-grid structure. In comparison with the prevailing “top-window” structure, the newly-designed device structure has simplified the fabrication procedures to avoid ultraviolet (UV) photolithography and SiO{sub 2}-eching. We systematically investigated the effect of chemical doping as well as device area on the device performance. It was found that a power conversion efficiency (PCE) of 5.9% can be achieved by engineering the work function of graphene through chemical doping. Our study indicates that top grid structure is suitable to make low-cost, large area and high efficiency graphene/Si Schottkey solar cell. - Graphical abstract: The engineering of the work function of graphene through chemical doping is an effective approach to improve the performance of monolayer graphene/Si Schottky solar cell. - Highlights: • Monolayer graphene/Si Schottkey solar cell was fabricated. • Chemical doping can effectively tune the work function of graphene film. • Chemical doping has significant effect on the device performance. • The top-grid device structure with graphene is promising with low-cost and high efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an Automatic Grid Generator for Multi-Element High-Lift Wings

The procedure to generate the grid around a complex wing configuration is presented in this report. The automatic grid generation utilizes the Modified Advancing Front Method as a predictor and an elliptic scheme as a corrector. The scheme will advance the surface grid one cell outward and the newly obtained grid is corrected using the Laplace equation. The predictor-corrector step ensures that the grid produced will be smooth for every configuration. The predictor-corrector scheme is extended for a complex wing configuration. A new technique is developed to deal with the grid generation in the wing-gaps and on the flaps. It will create the grids that fill the gap on the wing surface and the gap created by the flaps. The scheme recognizes these configurations automatically so that minimal user input is required. By utilizing an appropriate sequence in advancing the grid points on a wing surface, the automatic grid generation for complex wing configurations is achieved.

Eberhardt, Scott↗